HomeMy WebLinkAboutDUCK LEAKAGE TEST FORM02/13/2018 10:41 AM PST TO:17724621578 FROM:5616880909
Page: 1
Cove .
DUCT LEAKAGE TEST FORM
PROJECT ID:
16-0338.00
ea owoo
PROJECT NAME:
Fort Pierce, St, Lucie County .
BUILDER:
GHO Homes
COMMUNITY:
Meadowood
ADDRESS:
2703 Bent Pine Drive
LOT M
Lot No. 9-7.�`r
PERMIT*
DATE: Tuesday, February 13, 2018
r5 M T W tH F S
DAY: 1 13th
WEATHER:
TEMPERATURE:
WIND:
HUMIDITY:
BRIGHT SUN
CLEAR
OVERCAST
RAfN
X
BELOW 60
60.75
75.90
ABOVESO
X
LOW
MODERATE
HIGH
Report No
X
1
LOW
MODERATE
X
Duct Systems
CFM's
Total of All Systems: 21.19
Total Air Conditioned Square Footage: 2264
Required On on Energy Calc: 0,040
On: 0.009
System 1
21,19
System 2
System 3
System 4
PASS FAIL
AUTHORIZED THIRD PARTY
R403.2.2 Sealing (Mandatory). All ducts, air handlers, and filter boxes and building cavities that form the pamr ry air containment passageways for air distribution systems shall be
considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.72 of the Commercial Provisions of this code and shall be shaAln to meet
duct lightness criteria below, Duct tightness shall be verified by testing to Section 603 of the RESNET Standards by either individuals as defined in Section 553.993(5) or (7), Florida
Statutes, or individuals licensed as set forth In section 469.105(3)(f), (g), or (I), Florida Statutes, to be'substantia)ly leak free by either of the following: 1. Post construction test
Total leakage shall be less than or equal to 4 elm per 100 square feet of conditioned floor area when tested at a pressure differential of 0.1 Inches w.g. (25 Pa) across the entire
system, including the manufacturer's air handier enclosure. All registered boots shall be taped or othenviso seated during the lest, 2. Roughin test Total leakage shall be less than
or equal to 4 cfm per100 square feel of conditioned Soar area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including uie manufacturer's air
handler enclosure. All registers shall be taped or otherwise sealed during lho test, lithe air handier is not installed at the limo of rite test, total leakage shall he loss than or equal to 3
efm per too square feet conditioned near area. Exceptions: 1. The total leakage lost is not required for ducts and air handlers located entirelywithin the building thermal envelope, 2.
Duct testing is not mandatory for building complying by Section 405 of this code.
NAME: Nathan Monreal
GFA International, Inc.
2/13/2019
CATION: BPI ID# 5060035
FEB IS 2018
Environmental • Geotechnical • Construction Materials Testing . Special & Threshold Inspections • Plan Revievvv��� ROVED
sting
Florida's Leading Engineering Source www.teamgfa.com
02/13/2018
10:41 AM PST TO:17724621578 FROM:5616880909 Page: 2
607 NW Commodity Cove • Port St. Lucie, FL 34986
(772) 9243575 • (772) 924-3580 (fax)
A'itd��v
BLOWER DOOR TEST FORM
DATE: Tuesday, February 13, 2018
PROJECTID: 15-0338.00
ea owoo M T W TH F S
PROJECT NAME: Fort Pierce, St. Lucie County DAY:S 13th
BUILDER: GHO Homes
BRIGHT SUN CLEAR OVERCAST RAIN
COMMUNITY: Meadowood WEATHER: X
BELOW 60 60-75 75-90 ABOVE 90
ADDRESS: 2703 Bent Pine Drive TEMPERATURE: X
' LOW MODERATE HIGH Report No
LOT #: Lot No. 97 WIND: X
LOW MODERATE 1
PERMIT #: HUMIDITY: X
AIR INFILTRATION TEST RESULTS
CFM(50) = 1610
VOLUME = 21317.6
ACH(50) = CFM(50) X 60 / VOLUME = 4.531
PASS ® FAIL
AUTHORIZED THIRD PARTY
I hereby certify that the above Air Infiltration Test results demonstrate compliance with Florida Energy Code requirements in accordance
with the Florida Building Code -Energy Conservation R402.4.1.2 5th Edition (2014).
PRINTED NAME: Nathan Monreal
COMPANY: GFA international, Inc. ccn
DATE: 2/1312018 `e 2418
CERTIFICATION: BPI ID# 5060035