HomeMy WebLinkAboutENERGY EFFICIENCY CODE4
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: AVALON_eMEDITERRANEAN_MDW 97
Builder Name: GHO Homes
Street: 2703 Bent Pine Dr.
Permit Office:
City, State, Zip: FT. PIERCE, FL, 34951
Permit Number:
Owner: GHO Homes
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2303.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2042.40 ft2
b. Frame - Steel, Adjacent
R=11.0 260.56 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2416.7 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2284.00 ft2
6. Conditioned floor area above grade (ft2) 2284
b. Knee Wall (Vented)
R=19.0 132.67 ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(399.7 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 456.8
a. U-Factor: Dbl, U=0.49 196.00 ft2
SHGC: SHGC=0.24
b. U-Factor: Dbl, U=0.53 96.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
48.0 SEER:16.00
c. U-Factor: Dbl, U=0.46 70.17 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 37.58 ftz
a. Electric Strip Heat
48.0 COP:1.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 7.388 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
a. Natural Gas
Cap: 50 gallons
8. Floor Types (2284.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.175 Total Proposed Modified Loads: 78.26
PASS
Total Baseline Loads: 79.27
I hereby certify that the plans and specifications covered by
Review of the plans and
O��$E STA�6
this calculation are in compliance with the Florida En y
specifications covered by this
Code.
calculation indicates compliance
Energy
with the Florida Code.
r "'''"
PREPARED BY: Ryan McCracken
DATE: 6/30/2017
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O Tlj a
I hereby certify that t ' uild' s designed, is in compliance
Florida Statutes._
COD
with the Florida En gy C de.
WE.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage Woutdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn f I
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
F(1RM RAnti_gn1A
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
AVALON_eMEDITERRANEA Bedrooms: 3
User Conditioned Area: 2284
GHO Homes Total Stories: 1
1 Worst Case: No
GHO Homes Rotate Angle: 225
Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type: Street Address
Lot # 97
Block/SubDivision: Meadowood
PlatBook:
Street: 2703 Bent Pine Dr.
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL, 34951
CLIMATE
Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design .Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
2284 21309.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2284 21309.7 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 246.75 ft 0
2284 ftz ____ 1 0 0
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Barrel tile 2554 ftz 0 ftz Medium
0.75 No 0.9 No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 2284 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2284 ft2 0.11 Wood
132.67 ftz 0.11 Wood
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Belo
#
Ornt 10
Wall Typew
Space
1
S=>NE Garage
Frame - Steel
Main
11
14
4
9 4
133.8 ft2
0.23 0.01
0
2
E=>NW Garage
Frame - Steel
Main
11
2
1
9 4
19.4 ft'
0.23 0.01
0
3
S=>NE Garage
Frame - Steel
Main
11
3
8
9 4
34.2 ftz
0.23 0.01
0
4
W=>SE Garage
Frame - Steel
Main
11
3
10
9 4
35.8 ft2
0.23 0.01
0
_ 5
S=>NE Garage
Frame - Steel
Main
11
4
9 �, 4
37.3 ft2
0 0.01
0
6
S=>NE Exterior
Concrete Block - Int Insul
Main
4.1
11
9
9 4
109.7 ft2
0
0 0.600000
0
7
SE=>N Exterior
Concrete Block - Int Insul
Main
4.1
3
0
9 4
28.0 ft2
0
0 0.600000
0
8
E=>NW Exterior
Concrete Block - Int Insul
Main
4.1
3
7
9 4
33.4 ft2
0
0 0.600000
0
9
S=>NE Exterior
Concrete Block - Int Insul
Main
4.1
6
6
9 4
60.7 ftz
0
0 0.600000
0
10
W=>SE Exterior
Concrete Block - Int Insul
Main
4.1
7
8
9 4
71.6 ft2
0
0 0.600000
0
11
S=>NE Exterior
Concrete Block - Int Insul
Main
4.1
17
9 4
158.7 ft2
0
0 0.600000
0
12
E=>NW Exterior
Concrete Block - Int Insul
Main
4.1
47
4
9 4
441.8 ft2
0
0 0.600000
0
13
N=>SW Exterior
Concrete Block - Int Insul
Main
4.1
16
9 4
149.3 ft2
0
0 0.600000
0
14
W=>SE Exterior
Concrete Block - Int Insul
Main
4.1
11
6
9 4
107.3 ft2
0
0 0.600000
0
15
N=>SW Exterior
Concrete Block - Int Insul
Main
4.1
13
2
9 4
122.9 ft2
0
0 0.600000
0
16
NE=>W Exterior
Concrete Block - Int Insul
Main
4.1
3
6
9 4
32.7 ft2
0
0 0.600000
0
17
E=>NW Exterior
Concrete Block - Int Insul
Main
4.1
1
5
9 4
13.2 ft2
0
0 0.600000
0
18
NE=>W Exterior
Concrete Block - Int Insul
Main
4.1
5
2
9 4
48.2 ft2
0
0 0.600000
0
19
N=>SW Exterior
Concrete Block - Int Insul
Main
4.1
6
11
9 4
64.6 ft2
0
0 0.600000
0
20
E=>NW Exterior
Concrete Block - Int Insul
Main
4.1
4
9 4
37.3 ftz
0
0 0.600000
0
21
N=>SW Exterior
Concrete Block - Int Insul
Main
4.1
17
10
9 4
166.4 ft2
0
0 0.600000
0
22
W=>SE Exterior
Concrete Block - Int Insul
Main
4.1
42
6
9 4
396.7 ft2
0
0 0.600000
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft In
1 S=>NE
Wood
Main
None
.14
2
8
8 21.3
ft2
2 S=>NE
Insulated
Main
None
.14
3
8 24 ft2
3 " W=>SE
Insulated
Main
None
.14
1
1.2
8 8.8 ft2
4 NE=>W
Insulated
Main
None
.14
1
1.2
8 8.8 ft2
5 E=>NW
Insulated
Main
None
.14
1
1.2
8 8.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 225 degrees).
Wall
Overhang
# Ornt ID Frame Panes NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade Screening
1 S=>NE 6 Metal Low-E Double
Yes
0.49
0.24
30.0 ft2
4 ft 0 in
4 ft 1 in
Drapes/blinds
None
2 S=>NE 6 Metal Low-E Double
Yes
0.46
0.26
12.0 ft2
4 ft 0 in
1 ft11 in
Drapes/blinds
None
3 SE=>N 7 Metal Low-E Double
Yes
0.49
0.24
10.0 ft2
6 ft 3 in
7 ft 2 in
Drapes/blinds
None
4 SE=>N 7 Metal Low-E Double
Yes
0.46
0.26
3.0 ft2
6 ft 3 in
5 ft 2 in
Drapes/blinds
None
5 S=>NE 9 Metal Low-E Double
Yes
0.46
0.26
8.0 ft2
8 ft 6 in
5 ft 10 in
Drapes/blinds
None
6 S=>NE 9 Metal Low-E Double
Yes
0.46
0.26
8.7 ft2
8 ft 6 in
2 ft 7 in
Drapes/blinds
None
7 S=>NE 11 Metal Low-E Double
Yes
0.49
0.24
20.0 ft2
1 ft 0 in
3 ft 8 in
Drapes/blinds
None
8 E=>NW 12 Metal Low-E Double
Yes
0.46
0.26
10.0 W
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R4f15-gf114
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 225 degrees).
Wall
Overhang
V #
Ornt ID Frame
Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
9
E=>NW 12 Metal
Low-E Double Yes
0.49 0.24
6.0 ft2
1 ft 0 in
1 ft 0 in
Drapes/blinds
None
10
N=>SW 13 Metal
Low-E Double Yes
0.49 0.24
36.0 ft2
1 ft 0 in
3 ft 2 in
Drapes/blinds
None
11
W=>SE 14 Metal
Low-E Double Yes
0.25 0.18
12.5 ft'
26 ft 2 in
3 ft 4 in
Drapes/blinds
None
12
N=>SW 15 Metal
Low-E Double Yes
0.53 0.25
96.0 ft2
11 ft 6 in
3 ft 1 in
Drapes/blinds
None
13
N=>SW 15 Metal
Low-E Double Yes
0.46 0.26
18.0 ft2
11 ft 6 in
1 ft 1 in
Drapes/blinds
None
14
NE=>W 16 Metal
Low-E Double Yes
0.25 0.18
12.5 ft2
14 ft 2 in
3 ft 4 in
Drapes/blinds
None
15
NE=>W 18 Metal
Low-E Double Yes
0.49 0.24
18.0 ft2
7 ft 9 in
3 ft 2 in
Drapes/blinds
None
16
NE=>W 18 Metal
Low-E Double Yes
0.46 0.26
4.5 ft2
7 ft 9 in
1 ft 1 in
Drapes/blinds
None
17
N=>SW 19 Metal
Low-E Double Yes
0.49 0.24
24.0 ft2
4 ft 0 in
3 ft 2 in
Drapes/blinds
None
18
N=>SW 19 Metal
Low-E Double Yes
0.46 0.26
6.0 ft2
4 ft 0 in
1 ft 1 in
Drapes/blinds
None
19
E=>NW 20 Metal
Low-E Double Yes
0.25 0.18
12.5 ft2
26 ft 2 in
3 ft 4 in
Drapes/blinds
None
20
N=>SW 21 Metal
Low-E Double Yes
0.49 0.24
6.0 ft2
1 ft 0 in
3 ft 2 in
Drapes/blinds
None
21
W=>SE 22 Metal
Low-E Double Yes
0.49 0.24
40.0 ft2
1 ft 0 in
1 ft 1 in
Drapes/blinds
None
22
W=>SE 22 Metal
Low-E Double Yes
0.49 0.24
6.0 ft2
1 ft 0 in
1 ft 1 in
Drapes/blinds
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
685.99962666 ft2 685.99962666 ft2
70.5 ft
9.3334 ft
0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000415
2486.1 136.49 256.68
.3029
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat. None
COP:1
48 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Split
SEER: 16
48 kBtu/hr 1440 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap
Use
SetPnt
Conservation
1
Natural Gas
None Main
0.6 50 gal 60 gal
120 deg
None
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert. #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ftz
DUCTS
---- Supply
----
--- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R-Value
Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic 6
456.8 ft
Attic
114.2 ft Proposed Qn
Main
--- cfm
114.2 cfm 0.05
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans: N
Coolingr 1 Jan
[ 1 Feb
[
r Mar
[ ]
Apr [
May JunJul
Au
Se
r
Oct
Nov
r , Dec
Heatin[X] Jan
Feb
Mar
[ ]
AprMayJun
Jul
rj rl
AuSep
rl
rl
[
Oct
Nov
[X] Dec
Ventin [[[ ]]] Jan
[[[ ]]I Feb
[[[X Mar
[X]
A r [
Ma Jun Jul
Aug
Se
[[[XXX]]]
X
Oct X
Nov
[[[[ ]]]] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
r
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft')
7. Windows`* Description
a. U-Factor: Dbl, U=0.49
SHGC: SHGC=0.24
b. U-Factor: Dbl, U=0.53
SHGC: SHGC=0.25
c. U-Factor: Dbl, U=0.46
SHGC: SHGC=0.26
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
2703 Bent Pine Dr., FT. PIERCE, FL, 34951
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Int Insul, Exterior
b. Frame - Steel, Adjacent
1
c. N/A
3
d. N/A
10. Ceiling Types
No
a. Under Attic (Vented)
2284
b. Knee Wall (Vented)
Area
c. N/A
196.00 ft'
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
96.00 ft'
12. Cooling systems
70.17 ft'
a. Central Unit
Insulation
R=0:0
R=
R=
37.58 ft'
13. Heating systems
a. Electric Strip Heat
7.388 ft.
0.240
Area
14. Hot water systems
2284.00 ftz
a. Natural Gas
ft'
b. Conservation features
ft'
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energ�( saving features which will be installed (or exceeded)
in this home before final inspection. 04herwise, a new EPL Display Card will be completed
based on installed Code compliant fetyJes.
Builder Signature:
Address of New Home:
Date
/%
City/FL Zip: ; -el- e
Insulation Area
R=4.1 2042.40 ft'
R=11.0 260.56 ft'
R=
ft'
R=
ftz
Insulation
Area
R=30.0
2284.00 ftz
R=19.0
132.67 ft'
R=
ft'
R ft'
6 456.8
kBtu/hr
Efficiency
48.0
SEER:16.00
kBtu/hr Efficiency
48.0 COP:1.00
Cap: 50 gallons
EF: 0.6
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservati nEW1 Y
6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1