Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE4 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: AVALON_eMEDITERRANEAN_MDW 97 Builder Name: GHO Homes Street: 2703 Bent Pine Dr. Permit Office: City, State, Zip: FT. PIERCE, FL, 34951 Permit Number: Owner: GHO Homes Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2303.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 2042.40 ft2 b. Frame - Steel, Adjacent R=11.0 260.56 ftz 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2416.7 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2284.00 ft2 6. Conditioned floor area above grade (ft2) 2284 b. Knee Wall (Vented) R=19.0 132.67 ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(399.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 456.8 a. U-Factor: Dbl, U=0.49 196.00 ft2 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.53 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 48.0 SEER:16.00 c. U-Factor: Dbl, U=0.46 70.17 ft2 SHGC: SHGC=0.26 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 37.58 ftz a. Electric Strip Heat 48.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 7.388 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems a. Natural Gas Cap: 50 gallons 8. Floor Types (2284.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 2284.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.175 Total Proposed Modified Loads: 78.26 PASS Total Baseline Loads: 79.27 I hereby certify that the plans and specifications covered by Review of the plans and O��$E STA�6 this calculation are in compliance with the Florida En y specifications covered by this Code. calculation indicates compliance Energy with the Florida Code. r "'''" PREPARED BY: Ryan McCracken DATE: 6/30/2017 Before construction is completed this building will be inspected for compliance with Section 553.908 O Tlj a I hereby certify that t ' uild' s designed, is in compliance Florida Statutes._ COD with the Florida En gy C de. WE. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage Woutdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn f I 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 F(1RM RAnti_gn1A PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: AVALON_eMEDITERRANEA Bedrooms: 3 User Conditioned Area: 2284 GHO Homes Total Stories: 1 1 Worst Case: No GHO Homes Rotate Angle: 225 Cross Ventilation: Whole House Fan: Single-family New (From Plans) Address Type: Street Address Lot # 97 Block/SubDivision: Meadowood PlatBook: Street: 2703 Bent Pine Dr. County: St. Lucie City, State, Zip: FT. PIERCE, FL, 34951 CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design .Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 2284 21309.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2284 21309.7 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 246.75 ft 0 2284 ftz ____ 1 0 0 ROOF # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2554 ftz 0 ftz Medium 0.75 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2284 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2284 ft2 0.11 Wood 132.67 ftz 0.11 Wood 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo # Ornt 10 Wall Typew Space 1 S=>NE Garage Frame - Steel Main 11 14 4 9 4 133.8 ft2 0.23 0.01 0 2 E=>NW Garage Frame - Steel Main 11 2 1 9 4 19.4 ft' 0.23 0.01 0 3 S=>NE Garage Frame - Steel Main 11 3 8 9 4 34.2 ftz 0.23 0.01 0 4 W=>SE Garage Frame - Steel Main 11 3 10 9 4 35.8 ft2 0.23 0.01 0 _ 5 S=>NE Garage Frame - Steel Main 11 4 9 �, 4 37.3 ft2 0 0.01 0 6 S=>NE Exterior Concrete Block - Int Insul Main 4.1 11 9 9 4 109.7 ft2 0 0 0.600000 0 7 SE=>N Exterior Concrete Block - Int Insul Main 4.1 3 0 9 4 28.0 ft2 0 0 0.600000 0 8 E=>NW Exterior Concrete Block - Int Insul Main 4.1 3 7 9 4 33.4 ft2 0 0 0.600000 0 9 S=>NE Exterior Concrete Block - Int Insul Main 4.1 6 6 9 4 60.7 ftz 0 0 0.600000 0 10 W=>SE Exterior Concrete Block - Int Insul Main 4.1 7 8 9 4 71.6 ft2 0 0 0.600000 0 11 S=>NE Exterior Concrete Block - Int Insul Main 4.1 17 9 4 158.7 ft2 0 0 0.600000 0 12 E=>NW Exterior Concrete Block - Int Insul Main 4.1 47 4 9 4 441.8 ft2 0 0 0.600000 0 13 N=>SW Exterior Concrete Block - Int Insul Main 4.1 16 9 4 149.3 ft2 0 0 0.600000 0 14 W=>SE Exterior Concrete Block - Int Insul Main 4.1 11 6 9 4 107.3 ft2 0 0 0.600000 0 15 N=>SW Exterior Concrete Block - Int Insul Main 4.1 13 2 9 4 122.9 ft2 0 0 0.600000 0 16 NE=>W Exterior Concrete Block - Int Insul Main 4.1 3 6 9 4 32.7 ft2 0 0 0.600000 0 17 E=>NW Exterior Concrete Block - Int Insul Main 4.1 1 5 9 4 13.2 ft2 0 0 0.600000 0 18 NE=>W Exterior Concrete Block - Int Insul Main 4.1 5 2 9 4 48.2 ft2 0 0 0.600000 0 19 N=>SW Exterior Concrete Block - Int Insul Main 4.1 6 11 9 4 64.6 ft2 0 0 0.600000 0 20 E=>NW Exterior Concrete Block - Int Insul Main 4.1 4 9 4 37.3 ftz 0 0 0.600000 0 21 N=>SW Exterior Concrete Block - Int Insul Main 4.1 17 10 9 4 166.4 ft2 0 0 0.600000 0 22 W=>SE Exterior Concrete Block - Int Insul Main 4.1 42 6 9 4 396.7 ft2 0 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>NE Wood Main None .14 2 8 8 21.3 ft2 2 S=>NE Insulated Main None .14 3 8 24 ft2 3 " W=>SE Insulated Main None .14 1 1.2 8 8.8 ft2 4 NE=>W Insulated Main None .14 1 1.2 8 8.8 ft2 5 E=>NW Insulated Main None .14 1 1.2 8 8.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 225 degrees). Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>NE 6 Metal Low-E Double Yes 0.49 0.24 30.0 ft2 4 ft 0 in 4 ft 1 in Drapes/blinds None 2 S=>NE 6 Metal Low-E Double Yes 0.46 0.26 12.0 ft2 4 ft 0 in 1 ft11 in Drapes/blinds None 3 SE=>N 7 Metal Low-E Double Yes 0.49 0.24 10.0 ft2 6 ft 3 in 7 ft 2 in Drapes/blinds None 4 SE=>N 7 Metal Low-E Double Yes 0.46 0.26 3.0 ft2 6 ft 3 in 5 ft 2 in Drapes/blinds None 5 S=>NE 9 Metal Low-E Double Yes 0.46 0.26 8.0 ft2 8 ft 6 in 5 ft 10 in Drapes/blinds None 6 S=>NE 9 Metal Low-E Double Yes 0.46 0.26 8.7 ft2 8 ft 6 in 2 ft 7 in Drapes/blinds None 7 S=>NE 11 Metal Low-E Double Yes 0.49 0.24 20.0 ft2 1 ft 0 in 3 ft 8 in Drapes/blinds None 8 E=>NW 12 Metal Low-E Double Yes 0.46 0.26 10.0 W 1 ft 0 in 1 ft 0 in Drapes/blinds None 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R4f15-gf114 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 225 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 9 E=>NW 12 Metal Low-E Double Yes 0.49 0.24 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 N=>SW 13 Metal Low-E Double Yes 0.49 0.24 36.0 ft2 1 ft 0 in 3 ft 2 in Drapes/blinds None 11 W=>SE 14 Metal Low-E Double Yes 0.25 0.18 12.5 ft' 26 ft 2 in 3 ft 4 in Drapes/blinds None 12 N=>SW 15 Metal Low-E Double Yes 0.53 0.25 96.0 ft2 11 ft 6 in 3 ft 1 in Drapes/blinds None 13 N=>SW 15 Metal Low-E Double Yes 0.46 0.26 18.0 ft2 11 ft 6 in 1 ft 1 in Drapes/blinds None 14 NE=>W 16 Metal Low-E Double Yes 0.25 0.18 12.5 ft2 14 ft 2 in 3 ft 4 in Drapes/blinds None 15 NE=>W 18 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 7 ft 9 in 3 ft 2 in Drapes/blinds None 16 NE=>W 18 Metal Low-E Double Yes 0.46 0.26 4.5 ft2 7 ft 9 in 1 ft 1 in Drapes/blinds None 17 N=>SW 19 Metal Low-E Double Yes 0.49 0.24 24.0 ft2 4 ft 0 in 3 ft 2 in Drapes/blinds None 18 N=>SW 19 Metal Low-E Double Yes 0.46 0.26 6.0 ft2 4 ft 0 in 1 ft 1 in Drapes/blinds None 19 E=>NW 20 Metal Low-E Double Yes 0.25 0.18 12.5 ft2 26 ft 2 in 3 ft 4 in Drapes/blinds None 20 N=>SW 21 Metal Low-E Double Yes 0.49 0.24 6.0 ft2 1 ft 0 in 3 ft 2 in Drapes/blinds None 21 W=>SE 22 Metal Low-E Double Yes 0.49 0.24 40.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds None 22 W=>SE 22 Metal Low-E Double Yes 0.49 0.24 6.0 ft2 1 ft 0 in 1 ft 1 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 685.99962666 ft2 685.99962666 ft2 70.5 ft 9.3334 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000415 2486.1 136.49 256.68 .3029 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat. None COP:1 48 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 48 kBtu/hr 1440 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas None Main 0.6 50 gal 60 gal 120 deg None 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert. # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS ---- Supply ---- --- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.8 ft Attic 114.2 ft Proposed Qn Main --- cfm 114.2 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Coolingr 1 Jan [ 1 Feb [ r Mar [ ] Apr [ May JunJul Au Se r Oct Nov r , Dec Heatin[X] Jan Feb Mar [ ] AprMayJun Jul rj rl AuSep rl rl [ Oct Nov [X] Dec Ventin [[[ ]]] Jan [[[ ]]I Feb [[[X Mar [X] A r [ Ma Jun Jul Aug Se [[[XXX]]] X Oct X Nov [[[[ ]]]] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 r ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows`* Description a. U-Factor: Dbl, U=0.49 SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.53 SHGC: SHGC=0.25 c. U-Factor: Dbl, U=0.46 SHGC: SHGC=0.26 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. N/A 2703 Bent Pine Dr., FT. PIERCE, FL, 34951 New (From Plans) 9. Wall Types Single-family a. Concrete Block - Int Insul, Exterior b. Frame - Steel, Adjacent 1 c. N/A 3 d. N/A 10. Ceiling Types No a. Under Attic (Vented) 2284 b. Knee Wall (Vented) Area c. N/A 196.00 ft' 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main 96.00 ft' 12. Cooling systems 70.17 ft' a. Central Unit Insulation R=0:0 R= R= 37.58 ft' 13. Heating systems a. Electric Strip Heat 7.388 ft. 0.240 Area 14. Hot water systems 2284.00 ftz a. Natural Gas ft' b. Conservation features ft' None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energ�( saving features which will be installed (or exceeded) in this home before final inspection. 04herwise, a new EPL Display Card will be completed based on installed Code compliant fetyJes. Builder Signature: Address of New Home: Date /% City/FL Zip: ; -el- e Insulation Area R=4.1 2042.40 ft' R=11.0 260.56 ft' R= ft' R= ftz Insulation Area R=30.0 2284.00 ftz R=19.0 132.67 ft' R= ft' R ft' 6 456.8 kBtu/hr Efficiency 48.0 SEER:16.00 kBtu/hr Efficiency 48.0 COP:1.00 Cap: 50 gallons EF: 0.6 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservati nEW1 Y 6/30/2017 4:11 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1