Loading...
HomeMy WebLinkAboutNOA - CONCRETE TILESMIAMI-I DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade. County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Capistrano Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.15-0223.20 and consists of pages 1 through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. o 1 8` E a . /21� pi Approval Date: 06/16/16 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Capistrano Concrete Tile Lenght = 17" TAS 112 High profile concrete roof tile. For direct deck or Width = 12 1/4" Type I battened nail -on applications. Thickness ='/2" Class III Trim Pieces Lenght = varies TAS 112 Accessory trim, clay roof pieces for use at hips, Width = varies rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. NOA No.:16-0314.08 Expiration Date: 10/05/21 Approval Date: 06/16/16 . Page 2 of 7 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier PRI Asphalt Technologies ERPF-00 1 -02-02 Redland Technologies 7161-03 Appendix III Redland Technologies Letter Dated Aug. 1, 1994 Redland Technologies P09647-01 Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Celotex Corporation Testing Services Walker Engineering, Inc ATL of South Florida P0402 94-083 94-084 25-7094-(3, 6 & 9) 25-7120-(1 & 2) 25-7183-(3 & 4) 25-7214-(3, 4, &7) 25-7804-4 520111-3 520191-2-1 Calculations RT1211.02-15 Test Name/Report TAS-112 Static Uplift Testing TAS 102 & 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 102 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 Aerodynamic Multiplier TAS-112 Date Aug. 2006 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 April 1994 May 1994 Oct. 1994 Nov. 1994 Feb. 1995 March, 1995 Sep. 1996 Dec. 1998 March 1999 Sep. 2006 12/17/15 NOA No.:16-0314.08 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 3 of 7 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be required, refer to applicable Building Code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft) Width-w (ft) Capistrano Concrete Tile 10 1.417 1.04 Table 2: Aerodynamic Multipliers - A ft3 Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Capistrano Concrete Tile 0.300 0.277 Table 3: Restoring Moments due to Gravity - M. ft-lb Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":92" Capistrano Concrete Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.68 6.99 1 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38 NOA No.:16-0314.08 Mui•naoe couNTY Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min.19/32" plywood) Battens Capistrano 2-10d Ring Shank Nails 28.6 41.2 19.4 Concrete Tile 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8. Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail Field Clip) 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 2-10d Ring Shank Nails' 33.1 48.1 45.2 1. Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Capistrano Concrete Tile Adhesive 29.32 1 See manufactures component approval for installation requirements. 2 The Dow Chemical Company TileBond Average weight per patty 10.7 grams. ICP Adhesives Polyset® AH-160. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Capistrano Concrete Tile ICP Adhesives Polyset® AH-160 66.53 ICP Adhesives Polyset®AH-160 38.74 3 Large paddy placement of 63grams of Polyset® AH-160. 4 Medium paddy placement of 24grams of Polyset® AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Capistrano Concrete Tile Mortar Sets 24.5 5 Tile-Tite Roof Tile Mortar. NOA No.:16-0314.08 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 5 of 7 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". EAIGLE,0 �' FLORIDA (LOCATED ON UNDERSIDE OF TILE) Eon EAGLE FL (LOCATED ON FRONTSIDE OF TILE) CAPISTRANO CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. NOA No.:16-0314.08 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 6 of 7 PROFILE DRAWING MIL, iROLE I _�� • y "o� k. CAPISTRANO CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.:16-0314.08 Expiration Date: 10/05/21 Approval Date: 06/16/16 Page 7 of 7