HomeMy WebLinkAboutNOA - CONCRETE TILESMIAMI-I
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Eagle Roofing Products LLC
1575 East C.R. 470
Sumterville, FL 33585
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade. County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Capistrano Concrete Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.15-0223.20 and consists of pages 1 through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
o 1 8`
E a . /21� pi
Approval Date: 06/16/16
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub Category:
Roofing Tiles
Material:
Concrete
1. SCOPE:
This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing
Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For use in locations
where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure
values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The
attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION:
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Capistrano Concrete Tile
Lenght = 17"
TAS 112
High profile concrete roof tile. For direct deck or
Width = 12 1/4"
Type I
battened nail -on applications.
Thickness ='/2"
Class III
Trim Pieces
Lenght = varies
TAS 112
Accessory trim, clay roof pieces for use at hips,
Width = varies
rakes, ridges and valley terminations.
varying thickness
Manufactured for each tile profile.
NOA No.:16-0314.08
Expiration Date: 10/05/21
Approval Date: 06/16/16
. Page 2 of 7
2.1 EVIDENCE SUBMITTED:
Test Agency
Test Identifier
PRI Asphalt Technologies
ERPF-00 1 -02-02
Redland Technologies
7161-03
Appendix III
Redland Technologies
Letter Dated Aug. 1,
1994
Redland Technologies
P09647-01
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Celotex Corporation
Testing Services
Walker Engineering, Inc
ATL of South Florida
P0402
94-083
94-084
25-7094-(3, 6 & 9)
25-7120-(1 & 2)
25-7183-(3 & 4)
25-7214-(3, 4, &7)
25-7804-4
520111-3
520191-2-1
Calculations
RT1211.02-15
Test Name/Report
TAS-112
Static Uplift Testing
TAS 102 & 102(A)
Wind Tunnel Testing
TAS 108 (Nail -On)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Withdrawal Resistance Testing of screw
vs. smooth shank nails
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing
TAS 101 (Mortar Set)
Static Uplift Testing
TAS 102
Static Uplift Testing
TAS 102
Static Uplift Testing
TAS 102
Static Uplift Testing
TAS 102
Static Uplift Testing
TAS 102
Static Uplift Testing
TAS 101
Static Uplift Testing
TAS 101
Aerodynamic Multiplier
TAS-112
Date
Aug. 2006
Dec. 1991
Aug. 1994
Aug. 1994
Sept. 1993
April 1994
May 1994
Oct. 1994
Nov. 1994
Feb. 1995
March, 1995
Sep. 1996
Dec. 1998
March 1999
Sep. 2006
12/17/15
NOA No.:16-0314.08
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 3 of 7
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 shall be
required, refer to applicable Building Code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade County
Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless
stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable Building Code.
4. INSTALLATION
4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict
compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
Length -I (ft)
Width-w (ft)
Capistrano Concrete Tile
10
1.417
1.04
Table 2: Aerodynamic Multipliers - A ft3
Tile
Profile
A (ft3)
Batten Application
A (ft3)
Direct Deck Application
Capistrano Concrete Tile
0.300
0.277
Table 3: Restoring Moments due to Gravity - M. ft-lb
Tile
Profile
3":12"
4":12"
5":12"
6":12"
Greater than
7":92"
Capistrano
Concrete Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.68
6.99
1 6.57
6.88
6.44
6.73
6.28
6.56
6.10
6.38
NOA No.:16-0314.08
Mui•naoe couNTY Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min.19/32" plywood)
Battens
Capistrano
2-10d Ring Shank Nails
28.6
41.2
19.4
Concrete Tile
1-10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2-10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 #8. Screw
20.7
20.7
18.1
2 #8 Screw
43.2
43.2
29.8
1-10d Smooth or Screw
Shank Nail Field Clip)
23.1
23.1
19.0
1-10d Smooth or Screw
Shank Nail Eave Clip)
29.3
29.3
24.0
2-10d Smooth or Screw
Shank Nails Field Clip)
27.6
27.6
38.6
2-10d Smooth or Screw
Shank Nails Eave Clip)
38.1
38.1
41.8
2-10d Ring Shank Nails' 33.1 48.1 45.2
1. Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Capistrano Concrete Tile
Adhesive
29.32
1 See manufactures component approval for installation requirements.
2 The Dow Chemical Company TileBond Average weight per patty 10.7 grams.
ICP Adhesives Polyset® AH-160. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Capistrano Concrete Tile
ICP Adhesives Polyset® AH-160
66.53
ICP Adhesives Polyset®AH-160
38.74
3 Large paddy placement of 63grams of Polyset® AH-160.
4 Medium paddy placement of 24grams of Polyset® AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Capistrano Concrete Tile
Mortar Sets
24.5
5 Tile-Tite Roof Tile Mortar.
NOA No.:16-0314.08
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 5 of 7
5. LABELING :
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See
Detail Below), or following statement: "Miami -Dade County Product Control Approved".
EAIGLE,0
�'
FLORIDA
(LOCATED ON UNDERSIDE OF TILE)
Eon
EAGLE FL
(LOCATED ON FRONTSIDE OF TILE)
CAPISTRANO CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the
installation of this system.
NOA No.:16-0314.08
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 6 of 7
PROFILE DRAWING
MIL, iROLE
I
_�� • y
"o�
k.
CAPISTRANO CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.:16-0314.08
Expiration Date: 10/05/21
Approval Date: 06/16/16
Page 7 of 7