Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW MULLIONS (2)�`' • Florida Building Code Online Page 1 of 3 y.� iR,R •: 3.t� ii � � r � rx �w't^� p�{.y� u s,�yy. rsw ,r s -+-'Rt Florida D-partment! BCIS Home Log In ; User Registration ; Hot Topics Submit Surcharge % Stats & Facts ; Publications j FBC Staff BCIS Site Map Links ; Search Busines-/(�,� `� Product Approval Professional USER: Public User E Regulation Product Aoprnval Menu > Product or Acolicatton Search > Application Lkt > Application Detail � ,''-x+N�-u*, FL F FL15353-R2 "'' Application Type Revision Code Version 2014 Application Status Pending FBC Approval Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity ' Quality Assurance Contract Expiration Date Validated By Certificate or Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards, Certified By Sections from the Code Product Approval Method Date Submitted Date Validated httD://floridabuilding.org/pr/pr_app_ MI WindowsandDoors 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsltlinger@mlwd.com Brent Sitlinger bsitlinger@miwd.com Windows Mullions Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer J Evaluation Report - Hardcopy Received Luis R Lomas, PE PE-62514 National Accreditation & Management Institute 12/31/2015 Steven M. Urlch, PE Validation Checklist - Hardcopy Received FL15353 R2 COX FLCOI idf 1710.5.3 Method 2 Option B 06/15/2015 06/15/201S �/7/14/2015 Florida Building Code Online Page 2 of 3 Date Pending FBC Approval 06/21/2015 Summary of Products FL # IlAodel, Number or Name Description j 15353.1 15764 Horizontal Aluminum Mullion j Limits of Use Installation Instructions Approved for use In HVHZ: No FL15353 R2 II 08-01448A.pil Approved for use outside HVHZ: Yes .Verified By: Luis R Lomas, PE PE-62514 i Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84'. Max mullion span: FL15353 R2 AE 512072A.pdf 52-1/8". 1 Createdby Independent Third Party: Yes 15353.2 157r,4 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FL15353 R2 II 08-01439A.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion span: 83' FL15353 R2 AE 512063A.odf I Created by Independent Third Party: Yes 15353:3 15765 �— Horizontal-Aluminum,Mullion _ Fbiniwof Use - - - T.-'�'�``"' M--=• ��:>q In;tallati_on 3nstruttiorls•� r AQproved for use in HVHZ: No FL15353 R2 11 08-01449A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports j Other MBx Slflgie WIntlOW.51Ze: 52=Y/87 x:84?.,Ma%mu111on Span - R35353-R2 AF. 522071A.odf .-- - -- -Yes ���- rcRa--� �--• Created by Independent Third, Parry: 15353.4 15765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FL15353 R2 It 08-01440A.ndf Approved for use.outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8' x 84'. Max mullion span: 83". FL15353 R2 AE 512064A.odf Created by Independent Third Party: Yes j 15353.5 04-18514 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FL15353 P.2 Il 08-01442A.0 Approved for use outside HVHZ Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84'. Max mullion length - FL15353. R2 AE 512066A.odf 83", Created by Independent Third Party: Yes 15353.E CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 m 11 08-01451A pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant, Yes Created by Independent Third Party: Yes j Design Pressure. N/A Evaluation Reports Other: Max single window size - 52-1/8' x 84". Max mullion span - FL15353 R2 AE 512075A.rxlf 104-1/4' Created by Independent Third Party: Yes 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No F115353 R2 II 08-01452A odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 64". Max mullion span - FL15353 R2 AE 512076A.Cdf 104-1/4". .Created by Independent Third Party: Yes 15353.8 CM-18531 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 lI 08.01443A Odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Maxsingle window size: 52-1/8' x W. Max mullion span - 83' FL15353 R2 AE 512.067A.129f Created by Independent Third Party: Yes 15353.9 CM-18532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FU5353 R2 It 08-01453A.Ddf Approved for use outside HVHZ: Yes Verified By: LUis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion span - FL15353 R2 AE 512077A.odf 104-1/4" Created by Independent Third Party: Yes 15353.10 CM-18533 Vertical Aluminum Mullion Limns of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 11 08-01444A odf Approved for use outside HVHZ: Yes. Verified By: Luis R. Lomas, PE PE-62514 Impact Resistant: Yes Created' by Independent Third Party: Yes Design Pressure: N/A Other: Max window size: 52-1/8" x 84". Max mullion span: 83' Evaluation Reports Ft 15353 R2 AE 512068A nrif single Created by Independent Third Party: Yes 15353.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FL15353 R2 fi 06-01454A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8' x 84'. Max mullion span: FL15353 R2 AE 517078A.pdf 104-1/4'. Created by Independent Third Party: Yes htty://floridabuiiding.org/car/car_app_dtl.aspx?param=fGEVXQwtDgtH8572gvdWISXrzuli... 7/24/2015 NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2), WOOD FRAMING TO BE DESIGNED, AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR, THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = t 1 + V 2 REVISIONS REV I DESCRIPTION I DATE I APPROVED ' A I REVISED INSTALLATION DETAILS 06/10/15 1 R.L. ' ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X'SUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 2 1/2" MINIMUM EDGE DISTANCE, LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 4. 3) ALL FASTENERS TO BE CORROSION RESISTANT. 4) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). 5) TO ATTACH MULLION TO CLIP USE (4) h10 x 1 1/4" SELF DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED, HOLES FOR SCREWS ARE NOT PRE —DRILLED BY MANUFACTURER. I TABLE OF CONTENTS. SHEET NO. DESCRIPTION NOTES CONFIGURATIONS AND DP CHART INSTALLATION DETAILS MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 CM-18531 - VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAYIN: TWO NO. V. L. 08-01443 SCALE NTS JOATE 01/11/12 1 SHEEr1 OF SIGNED: 0611112015 E N ���9s�'i F' oTATE OF 0, i���is �ZZOR1DP *"7'9 ONA 11��\��\ 107 3/8" T OMBINED WIDTH W1 I[- W2 BS FRAME HEIGHT WINDOW WINDOW (MULLION / SPAN) j J- F_ 107 3/6" COMBINED WIDTH W1- r-W2 1117 3/11" COMBINED WIDTH r W 1 -jr W2 -_jll 83" f � FRAME WINDOW WINDOW INDOW (MULLION. SPAN) ` ! id /d 83" J / f WINDOW FRAME HEIGHT WINDOM, f WINDOW, (MULLION SPAN) tw1 �t- w2 -C107 3/8" OMBINED WIDTH Design pressure rating (Pan Units anchored Into wood framing Tributary w , 18.13 26.60 30,00 42.00 pn) 48.00 52.13 130.0 130.0 130.0 130.0 130.0 130.0 130.0 130.0 139.0 130.0 130.0 130.0 E409.63 130.0 130.0130.0 130.0 130.0 130.0 112.0 103.0 97.3 94.7 1300 130.0 1113.5 9. fiB.B B6,0 130.0 1174 91.3 62.6 77.0 74.1130.D 97.6 71.6 '63.2 57.2 54.0 107 3/8- Twi OMBINED WIDTH -Ir W2 8� IINDOWFRAME 4DOW HEIGHT (MULLION SPIT N) r/ 107 3/8" COMBINED WIDTH F-W 1� /W2 / 83" J/ / WINDOW a FRAME HEIGHT WINDOW WINDO (MULLION SPAN) L::-W1W2 107 3/8- COMBINED WIDTH REYSCNS REV I MSCRiMN DATE APFROVEO A I REVISED INSTALLATION DETAILS 106/10/15 R.L. _ 107 3/8" COMBINED WIDTH W1-1r-W2 831, /f J/ WINDOW FRAME HEIGHT WINDOM (MULLION SPAN) f APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS,LONG AS COMBINED WIDT14-00ES NOT EXCEED 107 318'AS SHOWN HEREIN. Design pressure rating (psn Units anchored Info masonry/concrete Tributary width (in) 18.13 25.50 36.00 42.00 48.00 52.13 130.0 130.0 130.0 130.0 130.0 130.0 N9.63 130.0 130.0 130.0 130.0 130.0 130.0 130.0 13110 130.0 130.0130,0 13 0. 0 1287 118.4 111.8 108.9130.0 130.0 118.9 106.E 102.1*8�.. 130.0 130.0 104.9 96.2 68.584.00 130.097.6 71.8 62 57.2 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE .DIMENSIONS 1N CHART ARE FRAME DIMENSIONS AND 00 NOT INCLUDE FLANGE �W1-11`--w2 107 3/8" COMBINED WIDTH MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 CM-18531 - VERTICAL MULLION 83" MULLION SPAN CONFIGURATIONS AND DP CHARTS DRAWN: DV/G N0. V.L. 08-01443 SCALE NTS DATE 01/11/12 ISKE2 OF 3 SIGNED: 0611112015 ?7 i •��GENSF'?s�: T((ME�.���. /� 0R1OP• �7� ONA1�1 2 1/2" MIN. --{ EDGE DISTANCE MASONRY/CONCRETE BY OTHERS � 3 17/32" c 1 1/4„ o°74 MIN. EMBEDMENT L SECT CM-18531 MULLION ALUMINUM 6005-T5.125" THICK 1/4" TAPCON SECT5768 CLIP" 4 5/8" SECT CM-18531 MULLION i 29/32" 27/32" SECT5768 f 25/32" CLIP 1 9/16" O I O 11 #10 WOOD SCREW 4X 05/32" 3/8" 1 3/8" MIN. SECT5768 CLIP EAAREDMENT ALUMINUM 6063-T5,083"THICK 1/2" MIN. WOOD FRAMING/ —�I EDGE 2X BUCK DISTANCE BY OTHERS VERTICAL CROSS SECTION MASONRY/CONCRETE AND WOOD FRAMING INSTALLATION NOTES: 1) FOR FRAMING INSTALLATION USE ALL FOUR HOLES IN INSTALLATION CLIP. 2) FOR MASONRY/CONCRETE INSTALLATION USE HOLES AT EACH END OF INSTALLATION CLIP. INSTALL TWO TAPCONS PER CLIP. REVISIONS DESCRIPTION DATE APPROVED REVISED INSTALLATION DETAIL 06/10/15 1 R.L. a CLIP INSTALLATION MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 CM-18531 - VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS IAM DING NO. .L. 08-01443 ALE NTS IDATE 01 /1 1 /12 5H` 73 OF 3 SIGNED: 0611112015 !L O o TTAAT�IrFF ; E O %ate.A�0R1'Dt- i��7s/ONA,1O:\1\��� 1 3/B" MIN. EMBEDMENT 1/2" MIN. EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS #10 WOOD SCREW SECTS768 / CLIP INTERIOR L� CM-18532 MULLION SELF STACK 1/4" TAPCON-� EXTERIOR MULLION INSTALLATION ANCHORING NOTES: 1) FOR ANCHORING INTO CONCRETE USE 1/4• TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE P10 TEK SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED INSTALLATION INSTRUCTIONS. 61 ALL FASTENERS TO BE CORROSION RESISTANT. 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATON INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 S. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. REVISIONS REV DESCRIPTION DATE I APPROVED 1 1/4" A REVISED INSTALLATION DETAILS 06/10/15 1 R.L. MIN. EMBEDMENT 2 1/2" ° d•. MIN. EDGE DISTANCE d MASONRY/CONCRETE BY OTHERS d SIGNED: 0611112015 Msso IwDOWESTMARKETS ANDDOORS I Ijro GRATZ, PA 17030-0370 `TREET \`\g11P. ��r ••\LENS 9J,% 061 k= CM-18532 HORIZONTAL MULLION*• SINGLE, TWIN AND TRIPLE WITH TRANSOM - ( - INSTALLATION DETAILS O; STATE OF ✓i�'n�S °P[ p jj10P; G�A\� DRAWN: DVIG NO. REV V. 08-0 E453 A SCALE DaiE NTS 03/06/12 3 OF 3 H1 168" MAX. COMBINED HEIGHT H2 .I� 156 3/8" MAX. UNIT WIDTH I-- (MULLION SPAN) WINDOW WINDOW WINDOW WINDOW d- ,.w ranarifv rhart theft Tributary Mullion Span and individual unit width (In) Height 54,00 72.00 90.00 108.00126.00 144.00 156.38 (in) f8.00 24.00 30.00 36.00 42.00 48.00 52,13 18.00 130.0 130.0 130.0 130.0 116.2 87.5 68.2 24.00 13D.0 130.0 130.0 106.2 89.4 66.0 51.5 30.00. 130.0 130.0 108.7 87.7 73.5 53.2 41.4 36.00 130.0 123.5 94.1 T5.5 62.9 44.7 34.8 42.00 130.0 110.0 83.4 66.8 55.5 38.7 30.1 48.00 130.0 99.9 75.3 60.1 49,9. 34.2 26.5 54.00 130.0 92.1 69.0 54.9 45.5 30.7 23.8 60.00 129.4 86.0 64.0 50.7 41.9 27.9 21.8 66.00 1 122.4 81.1 59.9 47.3 38.9 116.2 77.2 56.5 44.4 36.1 23:7 18.3 L72.00 78.00 110.5 1 73.9 1 53.7 1 42.0 33.8 22.1 17.1 64.00 105.4 1 70.8 1 51.4 1 40.0 1 31.8 20.8 16.0 LARGE AND SMALL MISSILE IMPACT LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16, 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. REVISIONS DESCRIPTION DATE I APPROVED REVISED INSTALLATION DETAILS 06/10/15 1 R.L. 4 5/8" 1 29/32" H 27/32" II a 8 1 9/16" O O 3/8 6XP5/32" "i � 1" SECT5768 CLIP ALUMINUM 6063-T5.093' THICK FOR WOOD FRAMING INSTALLATION 4 .3" - --{ 13/16" I 3" 1 9/16" 0 25 32 SECT5768 CLIP 2Xm5/32" ALUMINUM 6063•T5.093'THICK FOR MASONRY/CONCRETE INSTALLATION RIBUTARY HEIGHT = H1 + H2 2 5 3/32" CM-18532 MULLION ALUMINUM 6005•TS.125"THICK MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 CM-18532 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND COMPONENTS DRAWN: 'DWGNO. V.L. 08-01453 SCALE NTS I DATE 03/06/12 1SHEET OF 3 SIGNED: 0611112015 52 1/8" MAX. UNIT WIDTH �•----� (MULLION SPAN) H 1 WINDOW H1 WINDOW MAX.168" I COMBINED MAX, L MAX, COMBINED - COMBINED HEIGHT HEIGHT H2 WINDOW WINDOW N2 WINDOW Mavimum daelrm Amcccura /ncfl Tributary height Mullion span (in) 18.00 24.00 30.00 36.00 42.00 148.00 52,i3 18.OD 130.0 130.01 130.0 130.0 130.0 130.0 130.0 24.00 130.0 130.0 1130.0 130.0 130.0 130,0 130.0 30.00 130.0 130.0 130.0 130.0 130,0 130.0 130.0 36.00- 130.0 130.0 130.0 430.0 130.0 1300 130.0 42.00 130.0 130.0 130.0 130.0 130. 0 130.0 130.0 48.00 130.0 130.0 130.0 ,130.0 130.0 130.0 ,,130.0, 64.00 130.0 130,0 130.0 130.0 130:0 130.0 130.0 60.00 130.0 130,0 130,0 130.0 130.0 130,0 130.0 66.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 72.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 78.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 84.00 130.6 130,0 130.0 130,0 130.0 130.0 130:0 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND 00 NOT INCLUDE FLANGE 104.25" MAX. UNIT WIDTH (MULLION SPAN) Mavimum daQIrm nmeama ranarity rharl /ncfl Tributary Mullion Span and Individual unit width (in) Height (In) 36.00 48.00 60.00 72.00 1 KOO 196.00 104.25 1&00 24.00 30.00 36.00 42.00. 4&00 5Z13 16.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 24.00 130.0 130.0 130.0 130.0 130.0 121.3 110.5 30.00 130.0 130.0 130.0 130.0 118.2 100.7 91.4 30,00 130.0 130.0 130.0 125.8 103.0 87.1 78.8 42.00 130.0 130.0 130.0 113.7 92.5 77.7 70.0 48:00 130.0 130.0 130.0 104.5 84.7 70.8 63.5 64.00 130.0 130.0 127.0 97.4 75.6 65.5 58.6 60.00 130.0 130.0 120.8 91.8 1 73.7 1 61.2 54.7 88;00 130.0 130.0 115.7 B7,4 69,7 57.7 51.5 72.00 130.0 130.0 110.9. B3.9 66.5 64.8 48.8 78.00 130.0 130.0 106.6 80.9 63.8 52.4 46.5 84.00 130.0 130.0 102.6 78.1 1 61.6 1 50.3 44.6 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON TRIBUTARY HEIGHT= H1 + H2 PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT.. 2 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT, AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1, 2 ELEVATION, NOTES AND DESIGN PRESSURE CHARTS 3 INSTALLATION DETAILS REVISIONS DESCRIPTION LUTE I APPROVED REVISED INSTALLATION DETAILS 06/10/15 1 R.L. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION, WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY MI WINDOWS AND DOORS 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY. THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. 8) VERTICAL MULLIONS ARE NOT ,PART OF THIS APPROVAL. VERTICAL MULLIONS USED TO MULL UNITS SIDE BY SIDE MUST HAVE SEPARATE APPROVAL. 9) FOR ADDITIONAL APPROVED CONFIGURATIONS SEE SHEET 2. MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 CM-18532 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND GENERAL NOTES V. L. 1 08-01453 S.ME NTS °A7E 03/06/12 1 S"EET1 OF 3 SIGNED: 0611112016 0k IIII//,,z oh! J �,••'\r,ENq�.. TATr�Z