Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW MULLIONS• a... 3"S' .�� F,-hjri�"^.L'^'r ,F.' 'j' r' "T" } ♦ Irc car."' �,+>T 7 'p�+•'A:. +Xl; c. a, S �i r xt J jd tip! j r :». ��ti }' Jt f ;J r� °,.�. � ry�it S 1� }.. ,. t � i � �!jA'�r.:f" r ��E�'�rot •' . °�.: BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Starr Bcls site Map Links I Search Florida rl:•a d ao"%'�,-�V�ml Product Approval r g� USER: Public User . -X0 Product Approval Menu > Plan Detail > Application Detail R FL# FL15353-112 _ Application Type Revision Code Version 2014 1 •J / / Application Status Approved Comments `' v �J OR — Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sltlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Luis R Lomas, PE Evaluation Report Florida License PE-62514 Quality Assurance Entity National Accreditation & Management Institute Quality Assurance Contract Expiration Date 12/31/2017 Validated By Steven M. Urich, PE •` Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL15353 R2 COI FLCOI,Ddf r Sections from the Code 1710.5.3 Product Approval Method Method 2 Option B Date Submitted 06/15/2015 Date Validated 06/15/2015 Date Pending FBC Approval 06/21/2015 Date Approved 08/19/2015 Summary of Products FL # Model, Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01448A.pdf Approved for use outside HVHZ:,Yes Verified By: Luis R Lomas, PE PE-62514. Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R2 AE 512072A.pdf span: 52-1/81'. Created by Independent Third Party: Yes 15353.2 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01439A.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FLIS353 R2 AE 512063A.pdf span: 83" Created by Independent Third Party: Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FLIS353 R2 II 08-01449A.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R2 AE 512073A.odf span: 104-1/4" Created by Independent Third Party: Yes 15353.4 5765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01440A.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R2 AE 512064A.odf span: 83". Created by Independent Third Party: Yes 15353.5 CM-18514 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01442A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Design Pressure: N/A Created by Independent Third Party: Yes Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R2 AE 512066A.pdf length - 83". 1 Created by Independent Third Party: Yes 15353.6 CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01451A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R2 AE 512075A.odf span - 104-1/4" Created by Independent Third Party: Yes 115353.7 1 CM-18523 I Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 II 08-01452A.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FLIS353 R2 AE 512076A.odf span - 104-1/4". Created by Independent Third Party: Yes 115353.8 1 CM-18531 I Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No I FL15353 R2 II 08-01443A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FLIS353 R2 AE 512067A.pdf span - 83" Created by Independent Third Party: Yes 15353.9 CM-18532 _ Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R2 II 08-01453A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FLIS353 R2 AE 512077A.Ddf span - 104-1/4" Created by Independent Third Party: Yes 15353.10 CM-18533 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use In HVHZ: No FLIS353 R2 II 08-01444A.Ddf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other. Max single window size: 52-1/8" x 84". Max mullion FLIS353 R2 AE 512068A.Ddf span: 83" Created by Independent Third Party: Yes 15353.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R2 II 08-01454A.ndf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FLIS353 R2 AE 512078A.udf span: 104-1/4". Created by Independent Third Party: Yes BacY, Next Contact Us :: ZG01 Blair Stone Road, Tallahassee FL 32399 Phone: BSO-487-1824 The State of Florida Is an AA/EEO employer. Coovrlaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® O eCheck Credit Card Safe 52 1/8" MAX. UNIT WIDTH (MULLION SPAN) H 1 WINDOW MAX. MAX. J- COMB INED HEIGHT H2 WINDOW Mar/mnm r/nsinn nrasacuro /ncR Tributary height Mullion span (In) 1&00 24.00 30.00 136.00 4200 46.00 5213 1&00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 24.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 30.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 36.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 4200 130.0 130.0 130.0 130.0 130.0 130.0 130.0 48.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 a.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 60.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 66.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 7200 130.0 130.0 130.0 130.0 130.0 130.0 130.0 7& 00 130.0 130.0 130.0 130.0 13D.0 130.0 130.0 84.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 LARGEAND SMALL MISSILE IMPACT, LEVEL D. WIND ZONES DIMENSIONS IN CHART ARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE 104.25" MAX. UNIT WIDTH (MULLION SPAN) H 1 WINDOW 168" MAX. COMBINED HEIGHT H2 WINDOW WINDOW M-i- 4 cinn nrn -- rnrmnH 4-f I -A Tributary Height Mullion Span and individual unit width (n) 36.00 48.00 60.00 7200 84.00 96.00 104.25 On) 1&00 24.00 30.00 36.00 4200 48.00 5213 18.00 130.0 130.0 130.0 130.0 117.7 78.4 61.0 24.00 130.0 130.0 130.0 130.0 89.9 69.7 46.4 30.00 130.0 130.0 130.0 118.7 73.4 48.5 37.6 36.00 130.0 130.0 130.0 101.8 62.5 41.2 31.9 4200 130.0 130.0 130.0 89.9 54.9 36.0 27.8 48.00 130.0 130.0 130.0 - 81.2 49.3 322 24.8 54.00 130.0 130.0 124.7 74.5 45.0 29.3 225 60.00 130.0 130.0 116.5 69.4 41.6 27.0 1 20.7 66.00 130.0 130.0 109.9 GSA 38.9 25.1 1 19.2 7200 130.0 130.0 104.0 62.2 36.8 23.6 18.0 7&00 130.0 130.0 98.7 59.6 35.0 22.3 17.0 84.00 130.0 130.0 93.9 57.2 33.6 21.3 16.1 LARGEAND SMALL MISSILEIMPACT, LEVEL D, WINDZONE3 DIMENSIONS IN CHART ARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD, PER FLORIDA BUILDING CODE - CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2_ MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY HEIGHT= H1 + H2 2 TABLE OF CONTENTS SHEET NO. DESCRIPTION 1, 2 ELEVATION, NOTES AND DESIGN PRESSURE CHARTS 3 INSTALLATION DETAILS REVISIONS DESCRKION DATE APPROVED REVISED INSTALLATION DETAILS O6/11/15 1 R.L. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY MI WINDOWS AND DOORS 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. 8) VERTICAL MULLIONS ARE NOT PART OF THIS APPROVAL. VERTICAL MULLIONS USED TO MULL UNITS SIDE BY SIDE MUST HAVE SEPARATE APPROVAL. 9) FOR ADDITIONAL APPROVED CONFIGURATIONS SEE SHEET 2. MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND GENERAL NOTES DWG No. V.L. 08-01449 'CAE NTS PATE 03/06/12 1 SNEEr1 OF 3 SIGNED: 06/12/2015 �0\11111111/.' \5 TAT 6E OF ��� 156 3/8" MAX. UNIT WIDTH (MULLION SPAN) HI WINDOW 68" AX. BIKED IGHT H2 W/DOW WINDOW Maximum design pressure rapacity chart (Dst) Tributary Height (n) Mullion Span and Individual unit width On) $4.00 7200 90.00 108.00 126.00 144.00 156.38 16.00 24.00 30.00 36.00 4200 48.00 5213 18.00 130.0 130.0 97.1 55.8 35.0 23.4 182 24.00 130.0 130.0 73.8 42.3 26.5 17.7 13.8 30.00 130.0 119A 59.9 34.2 21A 14.2 11.1 36.00 130.0 101.5 50.7 28.9 18.0 12.0 4200 130.0 89.0 44.2 25.1 15.6 10.3 48.00 130.0 79.8 39.3 2Z3 13.8 SA00 130.0 7Z8 35.6 20.1 124 - - 60.00 129.4 67.4 327 18.3 11.3 66.00 122.4 63.3 30.3 16.9 10.4 7200 116.2 60.0 28.4 15.8 78.00 110.5 57.2 26.9 14.8 84.00 105.4 54.7 25.6 14.0 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. REVISIONS REV DESCRIPTION OAIE APPROVES A REVISED INSTALLATION DETNLS 06/11/15 R.L r4 5/8" -j 1 29/32" 27/32" 25/32" O OLI -' 8" 1 9/16° O J&13/16- 2" SECT5768 CLIP ALUMINUM 6063-T5.093" THICK FOR WOOD FRAMING INSTALLATION 4 3" - -- { 13/16" 3" I 1 9/16.. O 25 32' SECT5768 CLIP 2Xm5/32" ALUMINUM 6063-75.093"7HICK FOR MASONRY/CONCRETE INSTALLATION ITRIBUTARY HEIGHT = H1 + H2 2 SECT5765 MULLION ALUMINUM 6005-T5.125' THICK MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND COMPONENTS DRAY t OwG NO. V.L. 08-01449 SCALE NTS I DATE 03/06/12 ISHEET2 OF 3 SIGNED: 0611212015 `\J\5111�111� 0 �13 T6EOF; �0 '°Fs;:c�OR10P ���is�0NACE \\N 1 1/4" #10 WOOD MIN. EMBEDMENT MIN. EMBEDMENT SCREW 5765 MULLION SECT5768 1/2" MIN. CUP INTERIOR 1/4" TAPCON EDGE DISTANCE r WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR MULLION INSTALLATION ANCHORING NOTES: 1) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 TEK SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDjWAPPROVED INSTALLATION INSTRUCTIONS. 6) ALL FASTENERS TO BE CORROSION RESISTANT. 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI. MIN. EDGE DISTANCE a MASONRY/CONCRETE BY OTHERS a. REVISIONS REV DESCRIPTION I DATE I APPROVED A REVISED INSTALLATION DETAILS 06/11/15 1 R.L. CLIP INSTALLATION MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM INSTALLATION DETAILS V.L. 08-01449 SCALE NTS I DATE 03/06/12 5HEET3 OF 3 SIGNED: 0611212015 7 TAT SE OF �j9 NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN. MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16_ 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = Wl + W2 2 REVISIONS REV DESCRIPT*N DATE ,APPROVED A REVISED INSTALLATION DEEMS 06/10/15 1 R.L. ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 4. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS IN ACCORDANCE WITH WINDOW ANCHORING SCHEDULE AS SHOWN IN WINDOW SEPARATE APPROVAL 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD — MINIMUM SPECIFIC GRAVITY OF 0=0.42 B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). 6) TO ATTACH MULLION TO CLIP USE (4) #10 x 1 1/4" SELF DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED. HOLES FOR SCREWS ARE NOT PRE —DRILLED BY MANUFACTURER. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN: DWG N0. V.L. 08-01440 sratE NTS DATE 01 /11 /12 1SHEET 1 OF 3 SIGNED: 0611112015 P Low, v��GEIYSF9d+ E QF .•_,� 107 3/8' T OMBINED WIDTH Wl 83" FRAME HEIGHT WINDOW WINDOW (MULLION SPAN) � ` // 107 3/8- COMBINED WIDTH W1-I[-W2 B� /j/ FRAME 'WINDOW HEIGHT WINDOW (MULLION SPAN) 107 3/8" COMBINED WIDTH W7 W2 83" /� / WINDOW J FRAME HEIGHT WINDO ! ` /MND0 (MULLION SPAN) 1 1 LW1 �I- W2 107 3/8" COMBINED WIDTH Design aressure retina first) 1117 3/8" COMBINED WIDTH W1-I [-W2 83" L /y/FRAME WINDOW HEIGHT (MULLION SPAN) ! ! 107 3/8" COMBINED WIDTH Wt W2 83" WINDOW J FRAME HEIGHT WINDO WIND (MULLION SPAN)� ! ! 1:7W1 w2 107 3/8" COMBINED WIDTH Mullion span (n) Tributary 18.13 25.50 width 36.00 4200 on) 48.00 5213 25.00 130.0 130.0 130.0 130.0 130.0 130.0 37.38 130.0 130.0 130.0 130.0 130.0 130.0 49.63 130.0 130.0 130.0 130.0 130.0 130.0 6200 130.0 130.0 112.0 103.0 97.3 94.7 65.63 130.0 130.0 103.5 94.7 88.8 86.0 7200 130.0 117.4 91.3 82.8 77.0 74.1 84.00 120.2 87.0 64.0 56.4 51.0 48.1 107 3/8" COMBINED WIDTH F_ W1 W2 83" J !! J WINDOW ! J FRAME HEIGHT WINDO WINDOW (MULLION SPAN) I / / APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 10738' AS SHOWN HEREIN. LARGEAND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE w1--11- Lw2 107 3/8" COMBINED WIDTH SIGNED: 0611112015 2 1/2' MIN. EDGE DISTANCE MASONRY/CC BY OTHERS • a' " 1 1/4" MIN. EMBEDMENT I I I 1/4" TAPCON SECT5768 CLIP SECT5765 MULLION SECT5768 CLIP #10 WOOD SCREW I I I 1 3/8" MIN. EMBEDMENT WOOD FRAMING/ 2X BUCK 1/2" MIN. BY OTHERS EDGE DISTANCE VERTICAL CROSS SECTION MASONRY/CONCRETEAND WOOD FRAMING INSTALLATION NOTES: 1) FOR FRAMING INSTALLATION USE ALL FOUR HOLES IN INSTALLATION CUP. 2) FOR MASONRY/CONCRETE INSTALLATION USE HOLES AT EACH END OF INSTALLATION CUP. INSTALL TWO TAPCONS PER CLIP. REVISONS DESCRIPDON DATE I APPROVED REVISED INSTALLATION DETAILS 06/10/15 1 R.L 0.212" � � 3.800" --j —T 1.125" _L SECT5765 MULLION ALUMINUM 6005-T5.125' THICK 4.624" 1.891" 0.843" - 70 81" 1.562" 3 O 0 �I 4X 00.171" 0.375" --I 1.000" SECT5768 CLIP ALUMINUM 6063-T5.093' THICK SIGNED: 0611112015 MIWINDOWSIwDOW n AicErD DOORS S R!'�0�Z, EST EET GRATZ, PA 17030-0370 ��-s\ 9s��� `ter\GENS� *• 0 51 5765 VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS ��0 , TAT OF OV" Owc NO. RA V.L.DRAWN 08-01440 d+s:ORX' �A7////111111 �\\\ SCALE NTS DATE 01 /11 /12 SHEE73 OF 3