HomeMy WebLinkAboutPROJECT INFORMATIONIt 41 lilt Buildin Anal sis Job: Avalon Lot97 g Y Date: 4-21-17 Entire House By: Skyetec 051 • ect Information For: GHO Homes 2703 Bent Pine Drive, Saint Lucie County, FL 34951 Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28°N Outdoor: Heating Dry bulb (°F) 41 Daily range °F) - Wet - Wind speed (mph) 15.0 Indoor: Indoor temperature (°F) Design TD (°F) Relative humidity (%) Cooling Moisture difference (gr/lb) 90 Infiltration: 15 ( L ) Method 77 Construction quality 7.5 Fireplaces Heating Component Btuh/ftZ Btuh % of load Walls 4.1 7578 20.0 Glazing 13.8 5300 14.0 Doors 11.3 1297 3.4 Ceilings 0.9 2074 5.5 Floors 3.2 7192 19.0 Infiltration 1.9 3867 10.2 Ducts 7856 20.7 Piping 0 0 Humidification 0 0 Ventilation 2699 7.1 Adjustments 0 Total 37861 100.0 Component Btuh/ftZ Btuh % of load Walls 2.5 4677 13.5 Glazing 20.2 7761 22.4 Doors 11.4 1310 3.8 Ceilings 1.0 2345 6.8 Floors 0 0 0 Infiltration 0.5 1027 3.0 Ducts 9601 27.7 Ventilation 1433 4.1 Internal gains 6510 18.8 Blower 0 0 Adjustments 0 Total 1 1 34665 100.0 Latent Cooling Load = 9862 Btuh Overall U-value = 0.118 Btuh/ftZ-°F Data entries checked. -i +- wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269 ..oad Calculations\Skytec\Avalon Lot 97 GL NE.rup Calc = MJ8 Front Door faces: NE Heating Cooling 70 75 29 15 50 50 24.4 56.9 Simplified Average 0 Component Constructions Job: Avalon Lot 97 Entire House Date: 4-21-17 By: Skyetec Project For: GHO Homes 2703 Bent Pine Drive, Saint Lucie County, FL 34951 Y Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (T) 29 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 24.4 56.9 Dry bulb (T) 41 90 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (T) - 77 Construction quality Average Wind'speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/ft? °F ft? °FBluh Btuh/H' Btu Btuh/ft' Btu Walls 13A-4ocs: Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum n 16 0.143 4.0 4.15 66 2.59 41 board int fish ne 263 0.143 4.0 4.15 1089 2.59 679 se 435 0.143 4.0 4.15 1804 2.59 - 1126 sw 352 0.143 4.0 4.15 1459 2.59 911 w 49 0.143 4.0 4.15 203 2.59 127 nw 484 0.143 4.0 4.15 2005 2.59 1251 all 1598 0.143 4.0 4.15 6627 2.59 4136 Partitions 1213-0sm: Frm wall, stucco ext, r-11 cav ins, 1/2" gypsum board int 269 0.122 11.0 3.54 951 2.01 541 fish, 2"x4" metal frm, 16" o.c. stud Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n 4 0.460 0 13.3 51 10.1 39 thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45', medium; 50% outdoor insect screen; 5 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" n 12 0.490 0 14.2 177 10.2 127 thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45', medium; 50% outdoor insect screen; 5 ft overhang (6.5 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne 8 0.460 0 13.3 107 20.0 160 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 9.6 ft overhang (2 ft window ht, 2 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne 16 0.460 0 13.3 207 20.0 310 thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 4 ft overhang (3 ft window ht, 1 ft sep.); 6.67 ft head ht - + wrightsoft°' Right -Suite® Universal 2017 17.0.04 RS000269 2017-Jul-12 13:34 .4C ...oad Calculations\Skytec\Avalon Lot 97 GL NE.rup Calc = MJ8 Front Door faces: NE Page 1ge 1 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne 8 0.460 0 13.3 107 20.0 160 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 9.6 ft overhang (8 ft window ht, 4 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne 20 0.490 0 14.2 284 19.4 388 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" ne 31 0.490 0 14.2 441 19.4 601 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 4 ft overhang (6 ft window ht, 3 ft sep.); 6.67 ft • head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" se 2 0.490 0 14.2 26 10.8 20 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% w 2 0.490 0 14.2 26 24.9 46 outdoor insect screen; 3 ft overhang (2 ft window ht, 3 ft sep.); 6.67 ft nw 2 0.490 0 14.2 26 19.4 36 head ht all 6 0.490 0 14.2 78 18.3 101 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" se 9 0.490 0 14.2 128 15.2 136 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% sw 6 0.490 0 14.2 85 15.2 91 outdoor insect screen; 1.5 ft overhang (3 ft window ht, 1 ft sep.); 6.67 ft nw 6 0.490 0 14.2 85 19.4 116 head ht all 21 0.490 0 14.2 298 16.4 344 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" se 40 0.490 0 14.2 568 17.0 679 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft sw 40 0.490 0 14.2 568 17.0 679 head ht all 80 0.490 0 14.2 1137 17.0 1358 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" sw 6 0.460 0 13.3 80 10.1 61 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, ` 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 5 ft overhang (1.5 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" sw 18 0.460 0 13.3 240 10.1 182 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 13 ft overhang (1.5 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" sw 96 0.460 0 13.3 1281 10.1 970 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 13 ft overhang (8 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" sw 24 0.490 0 14.2 341 19.7 473 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (6 ft window ht, 5 ft sep.); 6.67 ft ' head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w 4 0.460 0 13.3 58 10.1 44 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 6 ft overhang (1.5 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w 17 0.460 0 13.3 227 20.7 353 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 6 ft overhang (6 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w 2 0.490 0 14.2 26 10.2 19 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 10 ft overhang (2 ft window ht, 3 ft sep.); 6.67 ft head ht Wrl htSOft' 2017-Jul-1213:34:48 9 Right -Suite® Universal 2017 17.0.04 RSU00269 �� Page 2 ..oad Calculations%Skytec\Avalon Lot 97 GL NE.rup Calc = MJ8 Front Door faces: NE 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" nw 12 0.460 0 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht Doors 11 DO: Door, wd sc type ne 24 0.390 0 se 23 0.390 0 w 23 0.390 0 nw 23 0.390 0 n 23 0.390 0 all 115 0.390 0 Ceilings 16D-30td:Attic ceiling, tile, slate, concrete roof mat, r-30 ceil ins, 1/2" gypsum board intfnsh Floors 22A-tpm: Bg floor, heavy dry or light damp soil, on grade depth, the flr fnsh 2235 0.032 30.0 13.3 160 20.0 240 11.3 271 11.4 274 11.3 256 11.4 259 11.3 256 11.4 259 11.3 256 11.4 259 11.3 256 11.4 259 11.3 1297 11.4 1310 0.93 2074 1.05 2345 210 1.180 0 34.2 7192 0 0 a i1tSO2017-Jul-1213:34:48 MCA... , WCI 9 ft® Right -Suite® Universal 2017 17.0.04 RS000269 _ Page 3 oad CalculationslSkyteclAvalon Lot 97 GL NE.rup Cale = MJ8 Front Door faces: NE Pro ect Summary Job: Avalon Lot 97 1 •1 Date: 4-21-17 Entire House By: Skyetec • For: GHO Homes 2703 Bent Pine Drive, Saint Lucie County, FL 34951 y' Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 / gr/lb Heating Summary Structure 30006 Btuh Ducts 7856 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 37861 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area(ft2 2235 2235 Volume (ft3) 22749 22749 Air changes/hour 0.32 0.16 ' Equiv. AVF (cfm) 121 61 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 12.3 kW 41975 Btuh OF 1500 cfm 0.040 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 25064 Btuh Ducts 9601 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 33071 Btuh Latent Cooling Equipment Load Sizing Structure 7017 Btuh Ducts 2845 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 9862 Btuh Equipment total load 42933 Btuh Req. total capacity at 0.80 SHR 3.4 ton Cooling Equipment Summary Make Rheem Trade RHEEM; RUUD Cond RA1648AJ1 Coil RH1T4821STAN AHRI ref 7943535 Efficiency 13.0 EER, 16 SEER Sensible cooling 36000 Btuh Latent cooling 9000 Btuh Total cooling 45000 Btuh Actual air flow 1500 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2017-Jul-1213:34:48 Right -Suite® Universal 2017 17.0.04 RS000269 Page 1 ..oad Calculations%SkytecWvalon Lot 97 GL NE.rup Calc = MJ8 Front Door faces: NE WIC 11 T 6x6 19 cfm 105 cfm BR 3 6 ", 5.7 ft� 4 ", 17.9 ft 12 x 12 7",8.3ft/ 1oxio 116 cfm�� BR 2 14 ", 18.0 10",5.1ft- 12 x 12� 4",5.OftJ Bath 2 F ff O j x�6 m �8x8 53 cfm 6 ". 11.3 ft i Avalon Nook 10 x 10 153 cfm T 8 ", 7.1 It 172 cfm 10x10 Kitchen -" / 10 ", 14.4 ft -30x18 10 x 10 134 cfm 7 ", 13.5 ft Great 7",7.4f / 134 cf 10x10 14 ", 9.0 ft 18",23.6ft Hall.I 41 cfm 10 x 10 ®.r 6 x 6 106 cfm y 7",7.9ft/ 4",5. ft Utility 18 ", 20.0 ft 18 ", 21.9 ft 16",10.0ft� 20 11.0ft T Dining 4",4.Oft 6x6/ 16 cfm Garage 4.0 Ton Job #: Avalon Lot 97 Performed by Skyetec for: GHO Homes 2703 Bent Pine Drive Saint Lucie County, FL 34951 5",4.6ft Master Bedroom m 7 ", 12.2 It 106 cfm 10x10 4",5.4ft 2cfm 6x6 T T lux10 106 cfn 7 ", 14.6 f t. is t 28 cfm F 6x6 Hers 5 ", 9.1 ft —4",10.7ft He W CO J/ 30x18 y 12x12 6 x 6 9 ", 10.5 ft 103 cfm 23 cfm M Bath O Schedule OExhaust Fan R Range Vent ODryer Vent Rheem Equipment ARI 7943535 AHU 4.0 Ton 16 SEER RH1T48 Cond 4.0 Ton 16 SEER RA1648 Scale: 1 : 114 Page 1 Right -Suite® Universal 2017 17.0.04 RSU00269 2017-Jul-12 13:35:06 ...s\SkyteclAvalon Lot 97 GL NE.rup • Duct System Summary Entire House For: GHO Homes 2703 Bent Pine Drive, Saint Lucie County, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.212 / 0.108 in H2O 0.102 in/100ft 1500 cfm Job: Avalon Lot 97 Date: 4-21-17 By: Skyetec Cooling 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.212 / 0.108 in H2O 0.102 in/100ft 1500 cfm 313 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk •-A h 642 25 15 0.194 4.0 Ox 0 VIFx 4.0 105.0 BR 2 c 2709 103 117 0.111 7.0 Ox 0 VIFx 36.3 155.0 st4 BR 3 c 2461 86 107 0.112 6.0 Ox 0 VIFx 33.8 155.0 st4 Bath 2 h 1368 54 38 0.141 4.0 Ox 0 VIFx 15.0 135.0 st2 Cabana h 2220 88 53 0.106 6.0 Ox 0 VIFx 39.4 160.0 st4 Dining h 3473 138 106 0.123 7.0 Ox 0 VIFx 31.5 140.0 st1 Foyer h 1438 57 47 0.126 5.0 Ox 0 VIFx 28.2 140.0 st1 Great Room C 3103 81 134 0.124 7.0 Ox 0 VIFx 31.0 140.0 st1 Great Room-B c 3103 81 134 0.120 7.0 Ox0 VIFx 37.1 140.0 st1 Hers h 1589 63 27 0.105 5.0 Ox0 VIFx 41.7 160.0 st3 His c 56 2 2 0.107 4.0 Ox 0 VIFx 38.1 160.0 st3 Kitchen C 4015 37 174 0.109 8.0 Ox0 VIFx 39.8 155.0 st4 M Bath h 4623 183 101 0.104 9.0 Ox0 VIFx 43.1 160.0 st3 Master Bedroom h 3419 135 107 0.102 7.0 Ox 0 VIFx 47.2 160.0 st3 Master Bedroom -A h 3419 135 107 0.103 7.0 Ox 0 VIFx 44.9 160.0 st3 Nook c 3550 147 154 0.111 8.0 Ox 0 VIFx 35.1 155.0 st4 Utility c 946 13 41 0.141 4.0 Ox 0 VIFx 15.6 135.0 st2 wC h 568 23 18 0.104 4.0 Ox 0 VIFx 43.4 160.0 st3 WIC h 1233 49 18 0.105 4.0 Ox 0 VIFx 45.9 155.0 st4 Bold/italic values have been manually overridden + wrightsoft® RightSuite® Universal 2017 17.0.04 RS000269 ...oad CalculationslSkyteclAvalon Lot 97 GL NE.rup Calc = MJS Front Door faces: NE 2017-Jul-12 13:34:48 Page 1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 541 361 0.102 506 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 897 784 0.102 508 1&0 0 x 0 VinlFlx st4 Peak AVF 510 622 0.105 582 14.0 0 x 0 VinlFlx st2 st2 Peak AVF 577 701 0.105 502 16.0 0 x 0 VinlFlx Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1500 1500 106.0 0.102 688 20.0 Ox 0 VIFx rst6 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst5 Peak AVF 1500 1500 0.102 688 20.0 0 x 0 VinlFlx rst6 Peak AVF 1500 1500 0.102 849 18.0 0 x 0 VinlFlx rst5 Bold/italic values have been manually overridden .+. + wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269 JCCX ...oad CalculationsMyteckAvalon Lot 97 GL NE.rup Calc = MJ8 Front Door faces: NE 2017-Jul-12 13:34:48 Page 2