HomeMy WebLinkAboutNOAa
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.eov/building/
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA # 09-0806.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Polystick MTS
Roll:
TAS 103
A homogeneous, rubberized asphalt
underlayment
65'8" x 3'33/3"
waterproofing membrane, glass fiber reinforced
Manufacturing Location
60 mils thick
with polyolefinic film on the upper surface for
#2
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
Polystick IR-Xe
Roll:
TAS 103 and
A fine granular/sand top surface self -adhering,
underlayment
65' x 3'33/$"
ASTM D 1970
APP polymer modified, fiberglass reinforced,
Manufacturing Location
Or 65' x 3'
bituminous sheet material for use as an
#1 & #2
80 mils thick
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
Polystick TU
Roll:
TAS 103 and
A heavy granuled surface self adhering, APP
underlayment
32' 10" x 3'33/s"
ASTM D 1970
polymer modified, fiberglass or polyester
Manyfacturing Location
100 mils thick
reinforced, bituminous sheet material for use as
#1 & #2
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus
Roll:
TAS 103 and
A non -wicking fabric surfaced, self -adhering,
underlayment
65' x 3'33/$"
ASTM D 1970
APP polymer modified, fiberglass reinforced
(Facer of Membrane
80 mils thick
with a high strength polyester fabric, bituminous
with surface printing)
sheet material for use an an underlayment in
Manufacturing Location
sloped roof assemblies. Designed as a metal
#1 & 92
roofing and roof tile underlayment.
Polystick TU P
Roll:
TAS 103 and
A rubberized asphalt waterproofing membrane,
underlayment
32' 10" x 3'33/$"
ASTM D 1970
glass-fiber/polyester reinforced, with a granular
Manufacturing Location
130 mils thick
surface designed for use as a tile roof
#2
underlayment.
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass -
Manufacturing Location 61' x 3'33/$" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and roof
tile underlayment.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 2 of 8
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick Dual Pro Roll: ASTM D 1970 A rubberized asphalt self -adhering, glass -
Manufacturing Location 6 P x 3'3-'/8" fiber/polyester reinforced waterproofing
#2 60 mils thick membrane, specific for use as a high
temperature underlayment. Designed as a metal
roofing.
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test AEency Test Identifier Test Name/Report Date
Exterior Research & Design, LLC
11756.04.01-1
TAS 103
04/27/01
11756.08.01-1
ASTM D 1970
08/14/01
02202.08.05
TAS 103
08/29/05
Trinity I ERD
P5110.08.07
TAS 103
08/29/07
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
PRI Asphalt Technologies
PRI01111
ASTM D 4977
04/08/02
PUSA-005-02-01
ASTM D 4977
01/31/02
PUSA-018-02-01
ASTM D 2523
07/14/03
PUSA-035-02-01
TAS 103
09/29/06
PUSA-033-02-01
ASTM D 1970
01/12/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-083-02-01
TAS 103
06/30/08
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX201-17A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX231)813
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
NOA No.: 11-0601.10
• MIAMI•DADE COUNTY Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self -adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re' -fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'/z" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non-
structural metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used
in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous
assemblies listed except roof tile systems.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Expos re Limitations (days)
MTS
IR-Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
180
180
180
Hazelton, PA.
N/A
30
30
180
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9B-72 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and
mechanically fastened roof tile applications. Polystick IR-Xe, and Tile Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick IR-Xe
Polystick TU, TU
Plus, TU P, Tile Pro
Flat Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
CL
0
in
N
tD
1
Roof Deck prepared with
POLYS71CKTU Plus
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR-Xe, TU, TU
Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift
resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniforin layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
S. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of all laps of the
patch.
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894-4563.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
• APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 8 of 8