Loading...
HomeMy WebLinkAboutSOIL DENSITY TEST REPORTengineering & testing, inc. - J DUNKUBERGER Svrl Density Test Report Project Name: Gazebo Addition - 511 NW Winters Creek Road Report Date: 12/29/2011 Palm City, Florida Address: 511 NW Winters Creek Rd Project Number: PSL-11-3422 (10.1) (Gazebo) Permit No: 1111-DO15 Client Name: Watlee Construction, Inc. Date Tested: 12 29/20 1 3163 SE Lionel Terrace Technician Initials: BG Stuart, Florida 34997 Project Manager: Dave Youngstrom Attention: Mr. Ryan Watley Contact Number: (772) 343-9787 Test No. Probe Depth (in) "Laboratory Procfor _ _ Fieldf Dry Cone Density Resistance' Moisture (pei) (tsf) (%) Tests Maximum Dry Density (pcf) Optimum Moisture (%) Minimum Required (%) Percent Maximum Density (%) Test ResultsCompaction 1 12 108.3 11.6 104.8 --- 12.0 95 96.8 Pass 2 12 108.3 11.6 104.2 -- 12.2 95 96.2 Pass 3 12 108.3 11.6 103.6 -- 11.7 95 95.7 Pass Type of Field Density Test: i' ASTM D 1556 rV ASTM D 6938 r- ASTM D 2937 Minimum Required Compaction Based on: iw AASHTO T-180 (ASTM D 1557) r AASHTO T-99 (ASTM D 698) Nuclear Gauge Info: Gauge No. 34488 Daily Standard Count: Density: 2391 Moisture: 722 �, `Test Soil Type 1 _ Elevaf>on ; �0-12 w µ `Test1L'ocat�on Gazebo,'S11;NW Winters Creek'R'oad' - Front of Gazebo Pad 1 2 1 0-12 Center of Gazebo Pad 3 1 0-12 Back of Gazebo Pad Elevation/Depth Referenced to: Y 1Structural Fill 2 Final Grading Fill 3 Mass Grading Fill 4 Utility Backfill - Sanitary 5 Utility Backfill - Water 6 Utility Backfill - Storm 7 Compacted Subgrade 8 Stabilized Subgrade 9 Base Course 10 Other: r NGVD r M SL W Other: Inches below top of floor slab subgrade. cc: Clil St. I�yc' Countytaiaspection Department ... (1) p�1%20j? S �vcbe�o Work David T. You;aTager som C/ Cr g E. Dunkelberger, P.E. Senior Project L Registration No. 4993 The original of this report was signed and sealed by the registered engineer in accordance wi R e 61G15-18011, of the Florida Administrative Code. This re ubmitte as a tial property of our client and authorization for publication of statements, conclusion or extracts or regarding this report is reserved pending our written approvti w io gard to subsurface exploration, recommendations or design are expressed by this firm. 1 Compaction percent estimated from cone penetrometer reading obtained with a Brainard-Kilman Model S-214 hand-held cone penetrometer. Fort Lauderdale - Port St. Lucie - West Palm Beach - Sarasota State of Florida Board of Professional Engineers Authorization No. 6870 877.643.6832 3422 10.1 Progress Report Gazebo PROCTOR POINT SUMMARY LOG SUMMARY OF TEST RESULTS Point 1 8.6 104.6 Test Method ASTM D-1557 Point 2 10.2 106.1 Maximum Dry Density (pcf) 108.3 Point 3 11.6 108.3 Optimum Water Content (%) 11.6 Point 4 15.0 105.8 Soil Classification SP Sample No. 11491 111 0 109 0 U. 'm 107 0 z 0 a 105 W Z 0 103 101 + 7 9 11 13 15 17 WATER CONTENT - PERCENT OF DRY WEIGHT Sample Location: MOISTURE - DENSITY RELATIONSHIP Bath House Building Pad Bath House Addition - 511 NW Winters Creek Road Sample Description: Palm City, FL (Martin County) Gray brown fine to medium SAND, trace D U H K E h B E R G E R silt engineering & testing, inc. % Passing U.S. Standard Tested By: AG Date: 12/30/11 Project: PSL-11-3422 (10.1) No. 200 Sieve: 4.6% lChecked By: DTY Date: 01/04/12 Sheet No.: 1 of 1 cc. Client ... (1); St. Lucie County Building Inspection Department ... (1) 3422 Proctor 11491