Loading...
HomeMy WebLinkAboutTRUSS PLACEMENT PLAN`BUILDER"S WARNING" -SEE FINAL ENGINEERING SHEETS FOR THE STRUCTURAL DATA, NUMBER OF GIRDER AND TRU PLIES AND THE CONNECTION INFORMATION. -OUR DESIGN DEPARTMENT MUST APPROVE ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ADVANCE. BACK CHARGES WILL NOT BE ACCEPTI P UNLESS OUR SS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE -ALL HANGERS ARE SIMPSON STRONG-fIE UNLESS OTHERWISE NOTED. INSTALL HANGERS ACCORDING TO THE CURRENT SIMPSON STRONG -TIE CATALOG r i'I,rFE'�.Ju. r O IV -THIS IS A PLACEMENT PLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1 - 1995. DIAPHRAMS HAVE NOT BEEN ANALYZED BY EAST CAOST TRUSS. -FOR ERECTION AND INSTALLATION OF TRUSSES FOLLOW INSTRUCTIONS ON THE BC61-B1 SUMMARY SHEETS AND SEALED ENGINEERED_TRUSS DRAWINGS -BRACING: 1) FOR THE ERECTION BRACING FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY SHEETS 2) PERMANENT BRACING FOR THE STRUCTURE IS HE RESPONSIBILITY OF OTHERS. 3) INSTALL WEB BRACING AS STATED ON SEALED ENGINEERING TRUSS DRAWINGS. .y -EJ3 -EJ3 _CJ1 IU U r 1' Z Z.2 3' 0 n 00 r-- r- �- N N N N t j 16' 0" TRUSS PLACEMENT PLAN 8'-0" T.O.B. ) 17'-2" T.O.B. THESE PLANIS ,'AND ALL 2, —,- ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITII ALL APPLICABLE CODES, SCAM404 ST LUCIE CObWY TYP. END DETAIL 12 • 11 y I) FAST {=;OA =>T TR1TCS � FL .li FIU _O1F'li;E: 17T_'.)-IQS64 2480 FAX: {, )4j;(; CUSTOMER: Watlee Construction JOB NAME Afshar Residence ADDRESS 511 NW Winters Creek Rd CITY/COUNTY Palm City / Saint Lucie JOB # 23015 OB # af MODEL : �,ARAGE: Q SQ FT 0 (ft2) DATE :12-12-11 IN ACCORDANCE WITH THE FLORIDA ADMINISTRATIVE CODE 61G15S-31.003 (3) (e), EAST COAST TRUSS 11 the "Truss Design Engineer" n Trusses are designed in accordance with the 1 Florida Building Code 2007 1 1 PPROVAL NOTE: By approving this placement plan(s), signatured anywhere on this sheet, the ustomer or his representative acknowledges that this placement plan complies I ith the structural intent of the project. I The customer also acknowledges that this approval authorizes EAST COAST 1 RUSS to manufacture these trusses and deliver them to the project indicated 1 In this drawing. I The customer also acknowledges that he/she accepts financial responsibility fo 1 ny repair, engineering, and labor required due to errors other than those of 1 EAST COAST TRUSS. 1 Signed: Date: 1 DESIGN CRITERIA - MAIN WIND FORCE 1 1 CODE: FBC 2007 w/ 09 SUPPLEMENT ASCE 7-05 1 1 LOADING: -- MEAN HEIGHT- 15' IMPORTANCE FACTOR=1 j EXPOSURE CATAGORY=B J MWF SPEED.- 140M.P.H. Q BUILDING TYPE: ENCLOSED Z TRUSS SPACING 24" O.C. EXCEPT LL AS NOTED = Q GRAV.ITy l�()ADS W CL FLOOR: ROOF: 75 TC LIVE: n/aPSF TC LIVE: 20PSF < TC DEAD: n/aPSF TC DEAD: 7PSF I--- 6 L-I'JE: n/aF'Si= BC L VE: 10AP SF C/) BC DEAD: n/aPSF BC DEAD: 5PSF DUR FACT: 1.0 DUR FACT: 1.25 OADS PER FBC & FRC J L NON -CONCURRENT BC LL 10psf Z ENGINEERED TRUSS UPLIFT MUST BY-PASS FLOOR TRUSSES UNLESS SHOWN ON � CONCURRENT BC STORAGE LL 20 sf DRAWING. V J ALL GIRDER/COLUMN LOADS MUST W BY-PASS FLOOR TRUSS UNLESS SHOWN — - ON ENGINEERED TRUSS DRAWING. I _ 2X6 STRONG BACK BRACING, 10'-0" O. C., IS RECOMMENDED ON FLOOR :D TRUSSES SPANNING 20'-0" OR MORE j-- — CAUTION: SPANS GREATER THAN 30'-0' MUST BE SET WITH A SPREADER BAR. THE SPREADER BAR SHOULD BE AT LEAST 1/2 TO — 2/3 IN LENGTH AS THE SPAN OF THE TRUSS W BEING SET. REFER TO BCI-B1 FOR COMPLETE �✓ J ERECTION AND SAFETY PROCEDURES. ALL BEAMS BY BUILDER NOTE: TRUSSES DO NOT W SUPPORT ANY PLANT SHELVES ` ^ f O REJECTED a RENEWED AS NOTED 0 REVISE AND RE•SUBmrr O ARCHITECT 0 1 201 > REVISIONS 0 3: - 5: 0 6: ( (1/4" if plot 18x24) . Designed by: TC a