HomeMy WebLinkAboutREVIEW - COMMENTSPlanning & Development Services Building 4Code.Re0ulation;Dl rislon 230t) Virginia Avenue Fort Pierce, FL.:34982, Phone:(772)462-2172 Fw(772)462-6443 PROPERTY INFORMATION Address: 707 Kitterman Rd City / State / Zip: Fort Pierce, FI 34952 Parcel#: 3415-501-0041-000/0 l Zoning: RF APPLICATION INFORMATION Permit Number: 1407-0353 Permit Type: BUILDING COMMERCIAL CONTRACTOR INFORMATION Contractor Name: James Walton Business Name: Creation Builders Inc Business Addr: 2613 Dyer Rd City / State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS REVIEW COMMENTS Page 1 Owner(s): Grace Emmanuel Church Inc Jurisdiction: ST LUCIE COUNTY Lot#: 3 Block: 3 Stories: Automatic Sprinkler System? No Fax Number: 772-878-9613 Email: Walton_James@Bellsouth. Net Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Audrey Humphrey ' 7/25/2014 7/28/2014 Comment: RECORDED NOTICE OF COMMENCEMENT 7/28/2014 Comment: ELECTRICAL AND MECHANICAL SUB AGREEMENT 7-30-2014 ELECTRICAL SUB SUMBITTED ON 7-30-2014- A HUMPHREY 7/28/2014 Comment: SIGNATURE PAGE WITH (2)ORIGINAL SIGNATURES 7/28/2014 Comment: THE GENERAL CONTRACTOR IS ON HOLD, PLEASE UPDATE YOUR LICENSE WITH OUR CONTRACTOR LICENSING DEP. (772) 462-1673. 7/28/2014 Comment: A LETTER OR UPDATED UTILITY CONTRACT FROM PORT ST LUCIE, REFLECTING THE ADDITIONAL USAGE OF WATER AND SEWER. 8/5/2014 Comment: VEG IN DRAWER (G) NO FEE ...VARIOUS PERMIT #S ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 8/1/2014 8/1/2014 Comment: FIRE DEPARTMENT REVIEW PENDING Tony Liento Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 7/25/2014 7/25/2014 7/25/2014 Comment: PLANS EXAMINER ELECTRIC PENDING Comment: Planning & DevelopmenIt.Services Building & Code.Reguiation Division 2300 Virginia Avenue: FortPierce;. FL 34982, Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 PLANS EXAMINER MECHANICAL PENDING Carl Peterson Comment: PLANS EXAMINER PLUMBING PENDING Greg Smyth Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 8/14/2014 Comment: SUBMIT [ 3 ] SETS OF THE DCA / DBPR APPROVED PLANS FOR THE MODULAR BUILDINGS FOR REVIEW 8/14/2014 FROM SOUTHEAST MODULAR *** CANNOT COMPLETE PIER AND ANCHOR REVIEW, FIRE SEPARATION, OR OPENING PROTECTION UNTIL WE RECEIVE THESE PLANS *** 8/14/2014 Comment: SUBMIT A THIRD PIER AND ANCHOR PLAN BY C.CALVERT MONTGOMERY * MUST BE ORIGINAL SIGNED, SEALED AND DATED 8/14/2014 Comment: PIER AND ANCHOR PLANS MUST BE DESIGNED TO WIND EXPOSURE "C" AND THE OCCUPANCY CATEGORY IS NOT II * PLEASE MODIFY ALL PLANS * Comment: PIER AND ANCHOR PLANS SPECIFY MASONRY UNITS LAID IN TYPE M OR S MORTAR * THIS IS NOT THE 8/14/2014 CASE IN THE PHOTOS SUBMITTED AND MUST BE ADDRESSED BY THE ENGINEER * COLUMNS APPEAR TO BE DRY STACKED AND MUST BE RE -DESIGNED BY ENGINEER 8/14/2014 Comment: THE RAMP PLANS AND LETTERS SUBMITTED, DESIGNED BY KEVIN FINN P.E. MUST BE IN ORIGINAL FORMAT, SIGNED, SEALED AND DATED AND DESIGNED TO 160 M.P.H. EXPOSURE "C" Comment: SUBMIT [ 3 ] ENGINEERS LETTERS STATING THE OPENING DESIGN PRESSURES TO RECEIVE THE STORM 8/14/2014 PANELS AND THE FULL PRODUCT APPROVAL IN TRIPLICATE REVIEWED AND APPROVED BY SAME ENGINEER 8/15/2014 Comment: NEED PLANS SHOWING THE WALL AREA OF THE EXISTING BUILDING WITH RELATED OPENING SQ FOOTAGES ADJACENT TO THE MODULAR CLUSTER 8/15/2014 Comment: COMMENTS MAILED AND E-MAILED AS OF THIS DATE * PENDING FURTHER REVIEWS ZONING REVIEW INCOMPLETE Lydia Galbraith 7/28/2014 Comment: PLEASE BE AWARE THAT WE WERE NOT ABLE TO COMPLETE THE ZONING REVIEW DUE TO THE ADJUSTMENT TO THE SITE PLAN NOT BEING APPROVED YET. THE PLANS WILL PROCEED THROUGH THE 7/28/2014 REVIEW PROCESS, HOWEVER, THE PERMIT WILL NOT BE ISSUED UNTIL SITE PLAN APPROVAL HAS BEEN RECEIVED AND ZONING HAS BEEN ABLE TO FINALIZE THE REVIEW. PLEASE BE AWARE THAT ADDITIONAL COMMENTS FROM DIFFERENT DEPARTMENTS MIGHT BE APPLICABLE. 7/28/2014 Comment: PLEASE PROVIDE SIDE AND REAR SETBACKS TO THE MODULAR BUILDINGS ON THE SITE PLAN 7/28/2014 Comment: PLEASE PROVIDE PROPOSED FINISHED FLOOR ELEVATION ON THE SITE PLAN. THE MIN. REQUIREMENTS ARE 18" ABOVE THE CROWN OF THE ROAD. 7/28/2014 Comment: PLEASE PROVIDE THE ELEVATION OF THE CROWN OF THE ROAD ON THE SITE PLAN.