Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEe FORM 60OA-2004R EnergyGauge® 4.5.2 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: CNETX_NIQORNINGSIDE 1851 3-7-07 Builder: CENTEX HOMES Address: Lot: Sub: MOORNINGSIDE, Plat: Permittin Office City, State: ST L CIE COUNTY, FL P i ; mb r: Owner: CUSTOM J i i N r:�Oopy Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 3 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 1851 ft2 7. Glass typel and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 166.0 ft2 _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Clear) 166.0 ft2 _ 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 182.0(p) ft _ b. N/A _ c. N/A _ 9. Wall types a. Concrete, Int Insul, Exterior R=4.1, 1193.0 ft2 _ b. Frame, Wood, Adjacent R=11.0, 252.0 ft2 _ c. N/A d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=19.0, 1851.0 ft2 b. N/A _ c. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.09 Total as -built points: 20293 PASS Total base points: 22406 I hereby certify that the plans and specifications covered by this calculation are in co liance with the En y Code. PREPARED BY: DATE: IS-O I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE:5-ly-0-11 Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCPB v4.5.2) Cap: 44.5 kBtu/hr _ SEER: 13.00 Cap: 15.5 kBtu/hr HSPF: 8.50 Cap: 40.0 gallons _ EF: 0.92 PT, FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNING$IDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 1851.0 24.35 8113.0 1.Single, Clear S 1.0 4.0 6.0 48.22 0.87 251.0 2.Single, Clear S 13.0 8.0 40.0 48.22 0.51 984.0 3.Single, Clear W 1.0 6.0 30.0 57.68 0.97 1678.0 4.Single, Clear N 1.0 6.0 15.0 30.19 0.98 441.0 5.Single, Clear E . 1.0 6.0 75.0 63.97 0.97 4655.0 As -Built Total: 166.0 8009.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 252.0 0.70 176.4 1. Concrete, Int Insul, Exterior 4.1 1193.0 1.18 1407.7 Exterior 1193.0 1.90 2266.7 2. Frame, Wood, Adjacent 11.0 252.0 0.70 176.4 Base Total: 1445.0 2443.1 As -Built Total: 1445.0 1584.1 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 18.0 1.60 28.8 1.Exterior Insulated 24.0 4.80 115.2 Exterior 24.0 4.80 115.2 2.Adjacent Wood 18.0 2.40 43.2 Base Total: 42.0 1".0 As -Built Total: 42.0 158.4 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1851.0 2.13 3942.6 1. Under Attic 19.0 1851.0 2.82 X 1.00 5219.8 Base Total: 1851.0 3942.6 As -Built Total: 1851.0 5219.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 182.0(p) -31.8 -5787.6 1. Slab -On -Grade Edge Insulation 0.0 182.0(p -31.90 -5805.8 Raised 0.0 0.00 0.0 Base Total: Z787.6 As -Built Total: 182.0 -5805.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 1851.0 14.31 26487.8 1851.0 14.31 26487.8 EnergyGauge@) DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT Summer Base points: 35342.9 Summer As -Built Points: 35653.4 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 44500btuh,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS) 35653 1.00 1 (1.08 x 1.150 x 0.85) 0.260 0.950 9342.9 35342.9 0.3250 11486.5 35653.4 1.00 1.061 0.260 0.950 9342.9 EnergyGauge'rm DCA Form 60OA-2004R EnergyGauge@1FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILD' GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 1851.0 9.11 3035.0 1.Single, Clear S 1.0 4.0 6.0 9.90 1.05 62.0 2.Single, Clear S 13.0 8.0 40.0 9.90 2.15 852.0 3.Single, Clear W 1.0 6.0 30.0 13.25 1.00 398.0 4.Single, Clear N 1.0 6.0 15.0 15.07 1.00 225.0 5.Single, Clear E 1.0 6.0 75.0 12.37 1.01 935.0 As -Built Total: 166.0 2472.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 252.0 1.80 453.6 1. Concrete, Int Insul, Exterior 4.1 1193.0 3.31 3942.9 Exterior 1193.0 2.00 2386.0 .2. Frame, Wood, Adjacent 11.0 252.0 1.80 453.6 Base Total: 1445.0 2839.6 As -Built Total: 1445.0 4396.5 DOORTYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 18.0 4.00 72.0 1.Exterior Insulated 24.0 5.10 122.4 Exterior 24.0 5.10 122.4 2.Adjacent Wood 18.0 5.90 106.2 Base Total: 42.0 194.4 As -Built Total: 42.0 228.6 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1851.0 0.64 1184.6 1. Under Attic 19.0 1851.0 0.87 X 1.00 1610.4 Base Total: 1851.0 1184.6 As -Built Total: 1851.0 1610.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 182.0(p) -1.9 -345.8 1. Slab -On -Grade Edge Insulation 0.0 182.0(p 2.50 455.0 Raised 0.0 0.00 0.0 Base Total: -345.8 As -Built Total: 182.0 455.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 1851.0 -0.28 -518.3 1851.0 -0.28 -518.3 EnergyGauge@ DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT Winter Base Points: 6389.6 Winter As -Built Points: 8644.2 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 15500 btuh ,EFF(8.5) Ducts:Unc(S),Con(R),Int(AH),R6.0 8644.2 1.000 (1.068 x 1.160 x 0.87) 0.402 0.950 3570.3 6389.6 0.5540 3539.8 8644.2 1.00 1.083 0.402 0.950 3570.3 EnergyGaugeT" DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details 5 ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 40.0 0.92 3 1.00 2460.00 1.00 7380.0 As -Built Total: 7380.0 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 11486 3540 7380 22406 1 9343 3570 7380 20293 PASS y0i ST 9?A�'{.n c coD WE EnergyGaugeTM' DCA Form 60OA-2004R EnergyGauge@)1FIaRES'2004R FLRCPB v4.5.2 FORM 60OA-2004R EnergyGauge® 4.5.2 Code Compliance Checklist Residential Whole Building Performance Method A - Details I ADDRESS: Lot: , Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, PERMIT #: I s 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Mulfi-storyHouses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGauge'"' DCA Form 60OA-2004R EnergyGauge@)/FlaRES'2004R FLRCPB v4.5.2 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.7 x The higher the score, the more efficient the home. CUSTOM, Lw�-' Sub: MOORNINGSIDE, Plat:, ST LUCIE COUNTY, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 44.5 kBtu/hr 3. Number of units, if multi -family 1 _ SEER: 13.00 4. Number of Bedrooms 3 _ b. N/A 5. Is this a worst case? Yes 6. Conditioned floor area (ftZ) 1851 ftZ _ c. N/A 7. Glass type and area: (Label regd. by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 166.0 ftZ _ a. Electric Heat Pump Cap: 15.5 kBtu/hr b. SHGC: HSPF: 8.50 _ (or Clear or Tint DEFAULT) 7b. (Clear) 166.0 ft- _ b. N/A _ 8. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 182.0(p) ft _ c. N/A b. N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 40.0 gallons a. Concrete, Int Insul, Exterior R=4.1, 1193.0 ftZ _ EF: 0.92 _ b. Frame, Wood, Adjacent R=11.0, 252.0 ft- _ b. N/A c. N/A d. N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=19.0, 1851.0 ftZ _ 15. HVAC credits PT, _ b. N/A _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 175.0 ft _ MZ-C-Multizone cooling, b. N/A _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card Will be completed based on installed liant features. Builder Signature: Date: • Address of New Home: Q Sa �� (kQ dJr : City/FL Zip: P `qerC *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation), your home may quay for energy efficiency mortgage (EEIIV incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on ages ages 2&4. EnergyGauge® (Version: FLKC v4.5.2) Load Short Form Job: -� Wrigh'tSOft" Date: thcr18ftchke Entire House By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. Project Information For: MOORNINGSIDE 03-05-07, CENTEX HOMES 1851, ST LUCIE COUNTY, FL Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make Lennox Trade 13HPD Series Model 13HPD-042-230* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 41000 Btuh @ 47°F 27 OF 1383 cfm 0.046 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Lennox Trade 13HPD Series Cond 13HPD-042-230* Coil CB26UH-042* Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13 SEER 31150 Btuh 13350 Btuh 44500 Btuh 1383 cfm 0.046 cfm/Btuh 0.00 in H2O 0.75 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) BEDROOM 4 168 3504 3269 161 152 BATH 2 84 820 679 38 31 BEDROOM 3 140 1983 2823 91 131 BEDROOM 2 140 1983 2823 91 131 MASTER BEDROOM 195 3031 4274 139 198 MASTER BATH 90 1077 839 49 39 WIC 70 2030 1087 93 50 FAMILY 352 6464 5757 297 267 KITCHEN 216 1611 3235 74 150 UTILITY 84 671 500 31 23 ... nn.� ^An en•f-7 ACAn Q40 e344 UIIVII1497I LIVIM7 J 14 V.7L I - c Printout certified by ACCA to meet all requirements of Manual J 8th Ed. �y�. Awing htsoft Right -Suite Residential 6.0.95 RSR43667 2007-Mar-08 09:50:09 ACCK C:1Documerdsand SettingskEngDeptPREFERREDAMMyDocumeMskightilCENTEXMOORNINGSIDEN8513-08.07 Page Entire House d 1851 30101 29835 1383 1383 Other equip loads 3215 1722 Equip. @ 0.95 RSM 29979 Latent cooling 10761 Ti►TAI 0 A0C 7713.4n Af%7AA A/]043 A707 Iv111LV IVJI JVJ IV TVI TV IVVJ IJVV Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,� wnghtsoft R1ghtSuite Residential 6.0.95 RSR43667 2007-Mar-08 09:50:09 ACCii C:\Documents and Settings\EngDept.PREFERREDAC\My DocumentsVightJ\CENTEX MOORNINGSIDEU851 3-08-07 Page 2 wrightsoft- Right-J Worksheet Job: '"'a .b'r' Entire House Date: By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 182.0 ft 9.0 ft d 1851.0 ft2 BEDROOM 4 26.0 ft 9.0 ft heat/cool 12.0 x 14.0 ft 168.0 ft' Ty Construction number U-value (Btuh/ft= °F) Or HTM (Btuh/ft2) Area (ft) or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 11 51A IA-clom 1A-clom 1A-clom IA-clom IA-01omd 11N0 12B-0bm 11N0 16A-19ad 22A-vph 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 0.350 0.049 1.358 n n a s w nw n - n - - 3.25 35.56 35.56 35.56 35.56 35.56 9.80 3.42 9.80 1.37 38.02 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 10.15 3.55 0.00 1386 6 30 18 75 40 24 252 0 1851 1851 1193 0 0 18 0 0 24 252 0 1851 182 3875 213 1067 640 2667 1422 235 861 0 2540 6920 3321 110 1040 329 2600 1136 244 271 0 6576 0 117 0 0 0 15 0 0 117 0 168 168 102 0 0 0 0 0 0 117 0 168 26 331 0 0 0 533 0 0 400 0 230 989 284 0 0 0 520 .0 0 126 0 597 0 P L--D C F 6 c) AED excursion 1185 212 Envelope loss/gain 20440 16810 2483 1738 12 a) Infiltration b) Room ventilation 3247 0 915 0 274 0 77 0 13 Internal gains: Occupants @ 230 8 1840 2 460 Appliances @ 1200 1 1200 0 0 Subtotal (lines 6 to 13) 23687 20766 2758 2275 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 23687 20766 2758 2275 15 Duct loads 27% 44% 6414 9069 27% 44% 747 994 Total room load 30101 29835 3504 3269 Air required (cfm) 1 1 1383 1383 1611 152 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 1 wrlJHTf--Oft RightSuite ResidenOal 6.0.95 RSR43667 2007-Mar-08 09:50:10 -45C4k C:1Documents and Settings\EngDeptPREFERREDAC\My Documentslright ACENTEX MOORNINGSIDE\1851 3-08-07 Page 1 - wrightsoft- Right-J Worksheet Job: tmr4kchaw Entire House By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area BATH 2 6.0 ft 9.0 ft heat/cool 6.0 x 14.0 ft 84.0 ftz BEDROOM 3 10.0 ft 9.0 ft heat(cool 10.0 x 14.0 ft 140.0 ftz Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ftj Area (W) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A IA-c1om 1A-c1om 1Aclom 1A-clom 1A-c1omd 11N0 12B-0bm 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 n n a s w nw n - 3.25 35.56 35.56 35.56 35.56 35.56 9.80 3.42 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 54 0 0 0 0 0 0 0 54 0 0 0 0 0 0 0 175 0 0 0 0 0 0 0 150 0 0 0 0 0 0 0 90 0 0 0 15 0 0 0 75 0 0 0 0 0 0 0 244 0 0 0 533 0 0 0 209 0 0 0 520 0 0 0 P L-D 11NO 16A-19ad 0.350 0.049 n 9.80 1.37 10.15 3.55 0 84 0 84 0 115 0 298 0 140 0 140 0 192 0 497 C F 22A-vph 1.358 - 38.02 0.00 84 6 228 0 140 10 380 0 6 c) AED excursion -12 219 Envelope loss/gain 1 519 437 1349 1445 12 a) Infiltration 126 36 211 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 645 473 1560 1965 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 645 473 1560 1965 15 Duct loads 27% 44% 175 206 27% 44% 422 858 ITTotal room load 820 679 1983 2823 Air required (cfm) 38 31 91 131 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrfghtsOlrC Right -Suite Residential 6.0.95 RSR43667 2007-Mar-08 09:50:10 /CCK CADocuments and SetBngs\EngDept.PREFERREDACVNy Documentslright J CENTEX MOORNINGSIDE11851 3-08-07 Page 2 + wrightssoft- Right-J Worksheet Dab Enure House By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area BEDROOM 2 10.0 ft 9.0 ft heat/cool 10.0 x 14.0 ft 140.0 ft2 MASTER BEDROOM 13.0 ft 9.0 ft heat/cool 13.0 x 15.0 ft 195.0 ft2 Ty Construction number U-value (BtuhtffL*F) Or HTM (Btuh/W) Area (ftj or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A 1A-clom IA-clom IA-clom 1A-clom 1Aclomd 11N0 12B-0bm 11NO 16A-19ad 22A-vph 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 0.350 0.049 1.358 n n a s w nw n - n - 3.25 35.56 35.56 35.56 35.56 35.56 9.80 3.42 9.80 1.37 38.02 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 10.15 3.55 0.00 90 0 0 0 15 0 0 0 0 140 140 75 0 0 0 0 0 0 0 0. 140 10 244 0 0 0 533 0 0 0 0 192 380 209 0 0 0 520 0 0 0 0 497 0 117 0 0 0 30 0 0 0 0 195 195 87 0 0 0 0 0 0 0 0 195 13 283 0 0 0 1067 0 0 0 0 268 494 242 0 0 0 1040 0 0 0 0 693 0 P L-D C F 6 c) AED excursion 219 463 Envelope loss/gain 1349 1445 2111 2438 12 a) Infiltration 211 59 274 77 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 2 0 460 0 2 0 460 0 Subtotal (lines 6 to 13) 1560 1965 2385 2975 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 27% 44% 0 0 0 1560 422 0 0 0 1965 858 27% 44% 0 0 0 2385 646 0 0 0 2975 1299 Total room load Air required (cfm) 1983 1 91 2823 U11 1 3031 1139 4274 198 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. RightSufte Residential 6.0.95 RSR43667 2007-Mar-08 09:50:10 ACCK C:1Documents and SettingsXEngDeptPREFERREDAC1My Documentslright DCENTEX MOORNINGSIDEl1851 3-08-07 Page 3 -- wrightsoft- Right-J Worksheet Job: d."o`.h.k' Entire House Date: By: PREFERRED AIR CONDITIONING 8r MECHANICAL, Inc. 1 Room name MASTER BATH WIC 2 3 Exposed wall Ceiling height 6.0 ft 9.0 It heat/cool 17.0 ft 9.0 ft heat/cool 4 Room dimensions 6.0 x 15.0 ft 7.0 x 10.0 ft 5 Room area 90.0 ftz 70.0 ft' Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft) Area (ft2) or perimeter (ft) Load (Btuh) Area (" or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A IA-clom IA-clom 1A-clom 1A-clom IA-c1omd IINO 1213-0bm 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 n n a s w nw n - 3.25 35.56 35.56 35.66 35.56 35.56 9.80 3.42 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 54 6 0 0 0 0 0 0 48 0 0 0 0 0 0 0 156 213 0 0 0 0 0 0 134 110 0 0 0 0 0 0 153 0 0 0 0 0 0 0 153 0 0 0 0 0 0 0 497 0 0 0 0 0 0 0 426 0 0 0 0 0 0 0 P L--D 11 NO 16A-19ad 0.350 0.049 n - 9.80 1.37 10.15 3.55 0 90 0 90 0 123 0 320 0 70 0 70 0 96 0 249 C F 22A-vph 1.358 - 38.02 0.00 90 6 228 0 70 17 646 0 6 c) AED excursion A5 -19 Envelope loss/gain 1 721 548 1239 656 12 a) Infiltration 126 36 358 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Subtotal (lines 6 to 13) 847 584 1598 757 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 847 584 1598 757 15 Duct loads 27% 44% 229 255 27% 44% 433 330 17 Total room load 1077 839 2030 1087 Air required (cfm) 1 149 39 931 50 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrrrg htsoft RightSuite Residential 6.0.95 RSR43667 2007-Mar-08 09:50:10 . CP. C:00cuments and SettingstEngDept.PREFERREDACUWy Documentsldght t10ENTEX MOORNINGSIDEX1851 3-08-07 Page 4 - - wrigh S0ft7 Right-J Worksheet Job: Entire House Date: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area FAMILY 32.0 ft 9.0 ft heat/cool 16.0 x 22.0 ft 352.0 ft2 KITCHEN 11.0 ft 9.0 ft heat/cool 12.0 x 18.0 ft 216.0 ftz Ty Construction number U-value (BtuhW °F) Or HTM (Btuh/ftz) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A IA-clom 1A-clom 1Aclom 1A-clom 1A-clomd 11NO 12B-0bm 11 NO 16A-19ad 22A-vph 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 0.350 0.049 1.358 n n a s w nw n - n - - 3.25 35.56 35.56 35.56 35.56 35.56 9.80 3.42 9.80 1.37 38.02 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 10.15 3.55, 0.00 288 0 15 0 0 40 0 0 0 352 352 233 0 0 0 0 0 0 0 0 352 32 757 0 533 0 0 1422 0 0 0 483 1217 649 0 520 0 0 1136 0 0 0 1250 0 99 0 0 0 0 0 0 0 0 216 216 99 0 0 0 0 0 0 0 0 216 11 322 0 0 0 0 0 0 0 0 296 418 276 0 0 0 0 0 0 0 0 767 0 P L-D C F 6 c) AED excursion 262 -56 Envelope loss/gain 1 4412 3817 1 1036 987 12 a) Infiltration b) Room ventilation 675 0 190 0 232 0 65 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 0 0 0 0 1 0 1200 Subtotal (lines 6 to 13) 5087 4007 1268 2252 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 27% 44% 0 0 0 5087 1377 0 0 0 4007 1750 27% 44% 0 0 0 1268 343 0 0 0 2252 983 Total room load Air required (cfm) 6464 1 297 5767 267 174 1611 3235 150 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Aftwrr+g htSofC Right -Suite Residential 6.0.95 RSR43667 2007-Mar-08 09:50:10 k C:IDocuments and Settings\EngDept.PREFERREDACWIy Documents\right JICENTEX MOORNINGSIDE\l 8513-08-07 Page 5 + wrightsoft- Right-J Worksheet Job: 'he'o"� Enure House Date: By: PREFERRED AIR CONDITIONING & MECHANICAL, Inc. 1 2 3 4 5 Room name Exposed wall Ceiling height Room dimensions Room area UTILITY 6.0 It 9.0 ft heat/cool 6.0 x 14.0 ft 84.0 ft2 DINING / LIVING 45.0 ft 9.0 ft heat/cool 13.0 x 24.0 ft 312.0 ft2 Ty Construction number U-value (Btuh/ft2--"F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (13 h) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 51A IA-clom IA-clom IA-clom 1A-clom 1A-clomd 11NO 12B-0bm 11 NO 16A-19ad 22A-vph 0.116 1.270 1.270 1.270 1.270 1.270 0.350 0.122 0.350 0.049 1.358 n n a s w nw n - n - - 3.25 35.56 35.56 35.56 35.56 35.56 9.80 3.42 9.80 1.37 38.02 2.78 18.28 34.66 19.76 34.66 28.39 10.15 1.07 10.15 3.55 0.00 0 0 0 0 0 0 0 54 0 84 84 0 0 0 0 0 0 0 54 0 84 6 0 0 0 0 0 0 0 184 0 115 228 0 0 0 0 0 0 0 58 0 298 0 324 0 15 18 0 0 24 81 0 312 312 267 0 0 18 0 0 24 81 0 312 45 867 0 533 640 0 0 235 277 0 428 1711 743 0 520 329 0 0 244 87 0 1108 0 P L-D C F 6 c) AED excursion -9 -79 Envelope loss/gain 528 348 4692 2952 12 a) Infiltration b Room ventilation 0 0 0 01 759 0 214 0 13 Internal gains: Occupants @ 230 Appliances @ 1200 0 0 0 0 0 0 0 0 Subtotal (lines 6 to 13) 528 348 5451 3166 14 15 Less external load Less transfer Redistribution Subtotal Duct leads 27% 44% 0 0 0 528 143 0 0 0 348 152 27% 44% 0 0 0 5451 1476 0 0 0 3166 1383 Total room load Air required (cfm) 671 31 500 23 6927 318 4549 211 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr7ghtsoft RightSuite Resldentia16.0.95 RSR43667 2007-Mar-08 09:50:10 AC^ C A C:\Documents and Settings\EngDeptPREFERREDAC\My Documentstright IICENTEX MOORNINGSIDE\1851 3-08-07 Page 6 'elayFax via port COM 1 From: 863 967 0137 3/2/2007 9:05,49 AM (Page 1 of 1) Mar 02 07 10:13a Fi Foil Company 863 967 0137 p.l MASONRY WALL SYSTEM VALUES /9�I Component R-Value Outside Air Film 0.17 Stucco 1/2" 1.00 8" Block 1.11 3/4" Furring 1.10 (24" O.C.) Fi-Foil's AA-2 Vapor Shield High Perm Reflective Insulation on .3/4" furring 4.1 1/2" Gypsum Wall Board 0.45 Inside Air Film 0.68 Total R-value = 8.61 0uoLve�011� The R-values shown are from the ASHRAE Handbook of fundamentals except for the Insulation. Fi-Foil's Insulations are tested to ASTM Standards and have SBCCI Compliance Reports are available. *Rounded to whole number 1/AGvr, - 11r4 Z - d - zq 3