FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs Residential Performance Method A
Project Name: Afshar Residence
Builder Name:
Street: 511 NW WINTERS CREEK RD
Permit Office:
City, State, Zip: PALM CITY, FL, 34990
Permit Number:
Owner. Afshar Residence
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1393.8 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggR=5.0 1393.80 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 1
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (420.0 sqft.)
Insulation Area
6. Conditioned floor area (ft2) 840
a. Under Attic (Unvented)
R=30.0 420.00 ft2
b. N/A
R= ft2
7. Windows(286.6 sqft.) Description Area
c. N/A
R= ft2
' a. U-Factor: Sgl, default 286.56 ft2
SHGC: Tinted, default
11. Ducts
b. U-Factor: N/A ft2
a. Sup: Ret: AH: Sup. R= ,ft2
• SHGC:
12. Cooling systems
c. U-Factor: N/A ft2
a. Central Unit
Cap: 36.0 kBtu/hr
SHGC:
SEER: 14.3
d. U-Factor: N/A ft2
13. Heating systems
SHGC:
a. Electric Heat Pump
Cap: 36.0 kBtu/hr
e. U-Factor: N/A ft2
HSPF:8.2
SHGC:
14. Hot water systems
8. Floor Types (420.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 420.00 ft2
EF: 0.92
b. N/A R= ft2
b. Conservation features
c. N/A R= ft2
None
15. Credits
CF, CV, Pstat
Total As -Built Modified Loads: 20.87
Glass/Floor Area: 0.341
PASS
Total Baseline Loads: 24.44
I hereby certify that the plans an sped iicatio covered by
Review of the plans and
�'04E ST,g?,
this calculation are in corn lian with, he Flo a Energy
specifications covered by this
ti��' :
Code.
calculation indicates compliance
�^
�O
with the Florida Energy Code.
m��r"-% ;_.=:•;;:,�`=��„
PREPARED Y:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
0 _ I � Jill - �
I hereby certify that this building, as designed, is in ompliance
Florida Statutes.
✓,�, ���
CDD
with the Florida En( ode.
WE.I�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: Ira• et
DATE:
12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5
PROJECT
Title:
Afshar Residence
Bedrooms: 1
Adress Type:
Street Address
Building Type:
FLAsBuilt
Conditioned Area: 840
Lot #
Owner:
Afshar Residence
Total Stories: 2
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
511 NW WINTERS CR
Permit Office:
Cross Ventilation: Yes
County:
MARTIN
Jurisdiction:
Whole House Fan: No
City, State, Zip:
PALM CITY,
Family Type:
Single-family
FL, 34990
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp Int Design Temp Heating
Design Daily Temp
v Design
Location TMY Site Zone 97.5 %
2.5 % Winter Summer Degree Days Moisture Range
FL,
Fort Pierce FL_ST LUCIE_CO_INTL 2 39
90 75 70 722
62 Low
FLOORS
#
Floor Type
Perimeter R-Value
Area
Tile Wood Carpet
1
Slab -On -Grade Edge Insulatio
82 ft 0
420 ft2
0 0 1
ROOF
Roof Gable
Roof Solar Deck
#
Type Materials Area Area
Color Absor. Tested Insul.
Pitch
1
Hip Barrel tile 455 ft2 0 ft2 Medium 0.4 N 30
22.6 deg
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Unvented 0
420 ft2 N N
CEILING
#
Ceiling Type
R-Value
Area Framing Frac
Truss Type
1
Under Attic (Unvented)
30
420 ft2 0.1
Wood
WALLS
Cavity Sheathing
Framing Solar
#
Ornt Adjacent To
Wall Type
R-Value Area R-Value
Fraction Absor.
1
N Exterior
Concrete Block - Polystyrene Bead Ag
5 339.75 ft2 0
0 0.3
2
E Exterior
Concrete Block - Polystyrene Bead Ag
5 357 ft2 0
0 0.3
3
S Exterior
Concrete Block - Polystyrene Bead Ag
5 340 ft2 0
0 0.3
4
W Exterior
Concrete Block - Polystyrene Bead Ag
5 357 ft2 0
0 0.3
12/12/2011 3:37 PM EnergyGauge D USA - FlaRes2008 Page 2 of 5
WINDOWS
Orientation shown is the entered, asBuilt orientation.
Overhang
#
Ornt Frame
Panes NFRC
U-Factor SHGC Storms Area Depth
.Separation
Int Shade
Screening
' 1
N Vinyl
Single (Tinted) No
1.3 0.64 N 27.99999 2 ft 0 in
2 ft 0 in
HERS 2006
None
2
N Vinyl
Single (Tinted) No
1.3 0.64 N 35.00000 2 ft 0 in
12 ft 0 in
HERS 2006
None
3
E Vinyl
Single (Tinted) No
1.3 0.64 N 32 ft2 2 ft 0 in
2 ft 0 in
HERS 2006
None
4
E Vinyl
Single (Tinted) No
1.3 0.64 N 30 ft2 2 ft 0 in
2 ft 0 in
HERS 2006
None
5
E Vinyl
Single (Tinted) No
1.3 0.64 N 100 ft2 2 ft 0 in
12 ft 0 in
HERS 2006
None
6
S Vinyl
Single (Tinted) No
1.3 0.64 N 18.66666 2 ft 0 in
2 ft 0 in
HERS 2006
None
7
S Vinyl
Single (Tinted) No
1.3 0.64 N 18.88888 2 ft 0 in
2 ft 0 in
HERS 2006
None
8
S Vinyl
Single (Tinted) No
1.3 0.64 N 20 ft2 2 ft 0 in
12 ft 0 in
HERS 2006
None
9
W Vinyl
Single (Tinted) No
1.3 0.64 N 4 ft2 2 ft 0 in
12 ft 0 in
HERS 2006
None
INFILTRATION & VENTING
/
-- Forced Ventilation -- Run Time
Fan
v Method
SIA CFM 50
ACH 50 ELA EgLA Supply CFM
Exhaust CFM
Fraction
Watts
Default
0.00036 793
6.30 43.5 81.9 0 cfm
0 cfm
0
0
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow SHR
Ducts
1
Central Unit
Split
SEER: 14.3 36 kBtu/hr
1080 cfm 0.75
Ductless
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Ducts
1
Electric Heat Pump None
HSPF: 8.2 36 kBtu/hr
Ductless
HOT WATER SYSTEM
#
System Type
EF Cap Use SetPnt
Conservation
1
Electric
0.92 40 gal 40 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model #
Area
Volume
FEF
None
None
ft2
12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Co in [X] Jan
[X]
[Xj Feb
[[XX]] Mar
IX] Apr
Ma
X�
[X Jun
[X] Jul
[X] AugX]
Se
Oct
Nov
X Dec
Neatin9 Jan
RiJan
Feb
[X] Mar
Apr
f May
[Xj Jun
[X] Jul
[X] Au9
[X] Sep
XOct
jXj
X Nov
IX
X Dec
Ventin
[X]] Feb
Lx�
[[XX]] Mar
[X] A r
L
[X Ma
[X Jun
[X] Jul
[X] Au
[X] Se
X Oct
X Nov
X Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5
FORM 1100A-08
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: 511 NW WINTERS CREEK RD PERMIT #:
PALM CITY, FL, 34990
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
N1106.AB.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
N1106.AB.1.2
Caulk, gasket, weatherstrip or seal between: windows/doors &
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at corners; utility penetrations;
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is
installed that extends from, and is sealed to, the foundation to the
top plate.
Floors
N1106.AB.1.2
Penetrations/openings > 1/8" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
is installed that is sealed to the perimeter, penetrations and seams.
Ceilings
N1106.AB.1.2
Between walls & ceilings; penetrations of ceiling plane to top floor;
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier; gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1/2" clearance & 3" from
insulation; or Type IC with < 2.0 cfm from conditioned space,
tested.
Multi-sto Houses
N1106.AB.1.2
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
heaters comply with NFPA, have combustion air.
OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N1112.ABC.3
Switch or clearly marked circuit breaker (electric) or cutoff (gas)
must be provided. External or built-in heat trap required.
Swimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
Air Distribution Systems
N1110.AB
All ducts, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N1107.AB.2
Separate readily accessible manual or automatic thermostat for
each system.
Insulation
N1104.AB.1
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.13.1.1
sides. Common ceiling & floors R-11.
t2/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 5 of 5
• ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*
= 85
The lower the EnergyPerformance Index, the more efficient the home.
511 NW WINTERS CREEK RD, PALM CITY, FL, 34990
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation Area
2. Single family or multiple family
Single-family a. Concrete Block - Polystyrene Bead AggR=5.0 1393.80 ftz
b. N/A
R= ftz
3. Number of units, if multiple family
1 c. N/A
R= ftz
4. Number of Bedrooms
1 d. N/A
R= ftz
5. Is this a worst case?
No 10. Ceiling Types
Insulation Area
6. Conditioned floor area (ftz)
840 a. Under Attic (Unvented)
R=30.0 420.00 ftz
b. N/A
R= ftz
7. Windows— Description
Area c. N/A
R= ftz
a. U-Factor: Sgl, default
286.56 ftz
SHGC: Tinted, default
11. Ducts
b. U-Factor: N/A
ftz a. Sup: Ret: AH: Sup. R= ,ftz
SHGC:
12. Cooling systems
c. U-Factor: N/A
ftz a. Central Unit
Cap: 36.0 kBtu/hr
SHGC:
SEER: 14.3
d. U-Factor: N/A
ftz 13. Heating systems
SHGC:
a. Electric Heat Pump
Cap: 36.0 kBtu/hr
e. U-Factor: N/A
ftz
HSPF:8.2
SHGC:
14. Hot water systems
8. Floor Types Insulation Area a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 420.00 ftz
EF: 0.92
b. N/A R=
ftz b. Conservation features
c. N/A R=
ftz None
15. Credits
CF, CV, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
0 TKE S
4VTgr�ot
wt ,
WE
*Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA -
FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home
may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at
(321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified
Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the
Department of Community Affairs at (850) 487-1824.
**Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G
of the Florida Building Code, Residential, if not DEFAULT.
EnergyGauge® USA - FlaRes2008
P.
ARNOLD A/C
Cooler By Design
Project Summary
Entire House
Project Information
For: Afshar Residence
511 NW WINTERS CREEK RD, PALM CITY, FL 34990
Notes:
Design Information
Weather: West Palm Beach, FL, US
Job:
Date: Oct 06, 2011
By:
Winter Design Conditions Summer Design Conditions
Outside db 47 OF Outside db 94 OF
Inside db 70 OF Inside db 75 OF
Design TD 23 OF Design TD 19 OF
Daily range L
Relative humidity 55 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure
17258
Btuh
Structure
24003
Btuh
Ducts
580
Btuh
Ducts
501
Btuh
Central vent (0 cfm)
0
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
17837
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.99
24259
Btuh
Infiltration
sensible
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Structure
1779
Btuh
Ducts
488
Btuh
Heating
Cooling
Central vent (0 cfm)
latent load
0
2267
Btuh
Btuh
Area (ft2)
840
840
Equipment
Volume (ft3)
7140
7140
Air changes/hour
0.61
0.32
Equipment total load
26526
Btuh
Equiv. AVF (cfm)
73
38
Req. total capacity at 0.75 SHR
2.7
ton
Heating Equipment
Summary
Cooling Equipment Summary
Make MITSUBISHI
Make MITSUBISHI
Trade
Trade
Model (1) PUMY-P36NHMU(-B5)
Cond 1) PUMY-P36NHMU(-B5)
ARI ref no.
Coil �2) PKFY-P18NHMU-
ARI ref no.
Efficiency
8.2 HSPF
Efficiency 14.3
SEER
Heating input
Sensible cooling
27000
Btuh
Heating output
40000
Btuh @ 470F
Latent cooling
9000
Btuh
Temperature rise
49
OF
Total cooling
36000
Btuh
Actual air flow
740
cfm
Actual air flow
740
cfm
Air flow factor
0.041
cfm/Btuh
Air flow factor
0.030
cfm/Btuh
Static pressure
0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.92
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
. +4d- wrigFttsoft- Right -Suite® Universal 7.1.24 RSU02818 2011-Dec-12 14:55:11
JAM ... Data\My Documentscustomer\Wrightsoft HVAC\Afshar Residence.rup Calc = MJB Orientation = E Page 1
Duct System Summary Job:
ARNOLD A/C Y rY Date: Oct 06, 201 1
Cooler By Design Entire House By:
Project Information
For: Afshar Residence
511 NW WINTERS CREEK RD, PALM CITY, FL 34990
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0 in H2O
0 in H2O
0 in H2O
0.00 / 0.00 in H2O
0 in/100ft
740 cfm
0 ft
Cooling
0 in H2O
0 in H2O
0 in H2O
0.00 / 0.00 in H2O
0 in/100ft
740 cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 1402
82
42
0
0
Ox 0
ShMt
0
0
BED ROOM
c 3604
100
109
0
0
Ox 0
ShMt
0
0
BED ROOM -A
c 3604
100
109
0
0
Ox 0
ShMt
0
0
BED ROOM-B
c 3604
100
109
0
0
Ox 0
ShMt
0
0
BONUS ROOM
c 3777
97
114
0
0
Ox 0
ShMt
0
0
BONUS ROOM -A
c 3777
97
114
0
0
Ox 0
ShMt
0
0
BONUS ROOM-B
c 3777
97
114
0
0
Ox 0
ShMt
0
0
KIT/LAUN
h 958
68
29
0
0
Ox0
ShMt
0
0
Return Branch Detail Table
Name
Grill
Size (in)
Htg
(cfm)
Cig
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
740
740
0
0
0
0
Ox 0
ShMt
i+ -,* wrightsoft- Right -Suite® Universal 7.1.24 RSU02818
...Data\My Documentscustomer\Wrightsoft HVACVifshar Residence.rup Calc = MJ8 Orientation = E
2011-Dec-12 14:55:11
Page 1