Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: Afshar Residence Builder Name: Street: 511 NW WINTERS CREEK RD Permit Office: City, State, Zip: PALM CITY, FL, 34990 Permit Number: Owner. Afshar Residence Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1393.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggR=5.0 1393.80 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (420.0 sqft.) Insulation Area 6. Conditioned floor area (ft2) 840 a. Under Attic (Unvented) R=30.0 420.00 ft2 b. N/A R= ft2 7. Windows(286.6 sqft.) Description Area c. N/A R= ft2 ' a. U-Factor: Sgl, default 286.56 ft2 SHGC: Tinted, default 11. Ducts b. U-Factor: N/A ft2 a. Sup: Ret: AH: Sup. R= ,ft2 • SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a. Central Unit Cap: 36.0 kBtu/hr SHGC: SEER: 14.3 d. U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 36.0 kBtu/hr e. U-Factor: N/A ft2 HSPF:8.2 SHGC: 14. Hot water systems 8. Floor Types (420.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 420.00 ft2 EF: 0.92 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits CF, CV, Pstat Total As -Built Modified Loads: 20.87 Glass/Floor Area: 0.341 PASS Total Baseline Loads: 24.44 I hereby certify that the plans an sped iicatio covered by Review of the plans and �'04E ST,g?, this calculation are in corn lian with, he Flo a Energy specifications covered by this ti��' : Code. calculation indicates compliance �^ �O with the Florida Energy Code. m��r"-% ;_.=:•;;:,�`=��„ PREPARED Y: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0 _ I � Jill - � I hereby certify that this building, as designed, is in ompliance Florida Statutes. ✓,�, ��� CDD with the Florida En( ode. WE.I� OWNER/AGENT: BUILDING OFFICIAL: DATE: Ira• et DATE: 12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 1 of 5 PROJECT Title: Afshar Residence Bedrooms: 1 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 840 Lot # Owner: Afshar Residence Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 511 NW WINTERS CR Permit Office: Cross Ventilation: Yes County: MARTIN Jurisdiction: Whole House Fan: No City, State, Zip: PALM CITY, Family Type: Single-family FL, 34990 New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 75 70 722 62 Low FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 82 ft 0 420 ft2 0 0 1 ROOF Roof Gable Roof Solar Deck # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Barrel tile 455 ft2 0 ft2 Medium 0.4 N 30 22.6 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 420 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 30 420 ft2 0.1 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Polystyrene Bead Ag 5 339.75 ft2 0 0 0.3 2 E Exterior Concrete Block - Polystyrene Bead Ag 5 357 ft2 0 0 0.3 3 S Exterior Concrete Block - Polystyrene Bead Ag 5 340 ft2 0 0 0.3 4 W Exterior Concrete Block - Polystyrene Bead Ag 5 357 ft2 0 0 0.3 12/12/2011 3:37 PM EnergyGauge D USA - FlaRes2008 Page 2 of 5 WINDOWS Orientation shown is the entered, asBuilt orientation. Overhang # Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth .Separation Int Shade Screening ' 1 N Vinyl Single (Tinted) No 1.3 0.64 N 27.99999 2 ft 0 in 2 ft 0 in HERS 2006 None 2 N Vinyl Single (Tinted) No 1.3 0.64 N 35.00000 2 ft 0 in 12 ft 0 in HERS 2006 None 3 E Vinyl Single (Tinted) No 1.3 0.64 N 32 ft2 2 ft 0 in 2 ft 0 in HERS 2006 None 4 E Vinyl Single (Tinted) No 1.3 0.64 N 30 ft2 2 ft 0 in 2 ft 0 in HERS 2006 None 5 E Vinyl Single (Tinted) No 1.3 0.64 N 100 ft2 2 ft 0 in 12 ft 0 in HERS 2006 None 6 S Vinyl Single (Tinted) No 1.3 0.64 N 18.66666 2 ft 0 in 2 ft 0 in HERS 2006 None 7 S Vinyl Single (Tinted) No 1.3 0.64 N 18.88888 2 ft 0 in 2 ft 0 in HERS 2006 None 8 S Vinyl Single (Tinted) No 1.3 0.64 N 20 ft2 2 ft 0 in 12 ft 0 in HERS 2006 None 9 W Vinyl Single (Tinted) No 1.3 0.64 N 4 ft2 2 ft 0 in 12 ft 0 in HERS 2006 None INFILTRATION & VENTING / -- Forced Ventilation -- Run Time Fan v Method SIA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 793 6.30 43.5 81.9 0 cfm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit Split SEER: 14.3 36 kBtu/hr 1080 cfm 0.75 Ductless HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 8.2 36 kBtu/hr Ductless HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.92 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 3 of 5 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Co in [X] Jan [X] [Xj Feb [[XX]] Mar IX] Apr Ma X� [X Jun [X] Jul [X] AugX] Se Oct Nov X Dec Neatin9 Jan RiJan Feb [X] Mar Apr f May [Xj Jun [X] Jul [X] Au9 [X] Sep XOct jXj X Nov IX X Dec Ventin [X]] Feb Lx� [[XX]] Mar [X] A r L [X Ma [X Jun [X] Jul [X] Au [X] Se X Oct X Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 4 of 5 FORM 1100A-08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 511 NW WINTERS CREEK RD PERMIT #: PALM CITY, FL, 34990 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi-sto Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. t2/12/2011 3:37 PM EnergyGauge® USA - FlaRes2008 Page 5 of 5 • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index, the more efficient the home. 511 NW WINTERS CREEK RD, PALM CITY, FL, 34990 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggR=5.0 1393.80 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ftz) 840 a. Under Attic (Unvented) R=30.0 420.00 ftz b. N/A R= ftz 7. Windows— Description Area c. N/A R= ftz a. U-Factor: Sgl, default 286.56 ftz SHGC: Tinted, default 11. Ducts b. U-Factor: N/A ftz a. Sup: Ret: AH: Sup. R= ,ftz SHGC: 12. Cooling systems c. U-Factor: N/A ftz a. Central Unit Cap: 36.0 kBtu/hr SHGC: SEER: 14.3 d. U-Factor: N/A ftz 13. Heating systems SHGC: a. Electric Heat Pump Cap: 36.0 kBtu/hr e. U-Factor: N/A ftz HSPF:8.2 SHGC: 14. Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 420.00 ftz EF: 0.92 b. N/A R= ftz b. Conservation features c. N/A R= ftz None 15. Credits CF, CV, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: 0 TKE S 4VTgr�ot wt , WE *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the Department of Community Affairs at (850) 487-1824. **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008 P. ARNOLD A/C Cooler By Design Project Summary Entire House Project Information For: Afshar Residence 511 NW WINTERS CREEK RD, PALM CITY, FL 34990 Notes: Design Information Weather: West Palm Beach, FL, US Job: Date: Oct 06, 2011 By: Winter Design Conditions Summer Design Conditions Outside db 47 OF Outside db 94 OF Inside db 70 OF Inside db 75 OF Design TD 23 OF Design TD 19 OF Daily range L Relative humidity 55 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17258 Btuh Structure 24003 Btuh Ducts 580 Btuh Ducts 501 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17837 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.99 24259 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1779 Btuh Ducts 488 Btuh Heating Cooling Central vent (0 cfm) latent load 0 2267 Btuh Btuh Area (ft2) 840 840 Equipment Volume (ft3) 7140 7140 Air changes/hour 0.61 0.32 Equipment total load 26526 Btuh Equiv. AVF (cfm) 73 38 Req. total capacity at 0.75 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make MITSUBISHI Make MITSUBISHI Trade Trade Model (1) PUMY-P36NHMU(-B5) Cond 1) PUMY-P36NHMU(-B5) ARI ref no. Coil �2) PKFY-P18NHMU- ARI ref no. Efficiency 8.2 HSPF Efficiency 14.3 SEER Heating input Sensible cooling 27000 Btuh Heating output 40000 Btuh @ 470F Latent cooling 9000 Btuh Temperature rise 49 OF Total cooling 36000 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.030 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . +4d- wrigFttsoft- Right -Suite® Universal 7.1.24 RSU02818 2011-Dec-12 14:55:11 JAM ... Data\My Documentscustomer\Wrightsoft HVAC\Afshar Residence.rup Calc = MJB Orientation = E Page 1 Duct System Summary Job: ARNOLD A/C Y rY Date: Oct 06, 201 1 Cooler By Design Entire House By: Project Information For: Afshar Residence 511 NW WINTERS CREEK RD, PALM CITY, FL 34990 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.00 / 0.00 in H2O 0 in/100ft 740 cfm 0 ft Cooling 0 in H2O 0 in H2O 0 in H2O 0.00 / 0.00 in H2O 0 in/100ft 740 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1402 82 42 0 0 Ox 0 ShMt 0 0 BED ROOM c 3604 100 109 0 0 Ox 0 ShMt 0 0 BED ROOM -A c 3604 100 109 0 0 Ox 0 ShMt 0 0 BED ROOM-B c 3604 100 109 0 0 Ox 0 ShMt 0 0 BONUS ROOM c 3777 97 114 0 0 Ox 0 ShMt 0 0 BONUS ROOM -A c 3777 97 114 0 0 Ox 0 ShMt 0 0 BONUS ROOM-B c 3777 97 114 0 0 Ox 0 ShMt 0 0 KIT/LAUN h 958 68 29 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grill Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 740 740 0 0 0 0 Ox 0 ShMt i+ -,* wrightsoft- Right -Suite® Universal 7.1.24 RSU02818 ...Data\My Documentscustomer\Wrightsoft HVACVifshar Residence.rup Calc = MJ8 Orientation = E 2011-Dec-12 14:55:11 Page 1