HomeMy WebLinkAboutREVISION7eTdNXS9WL*_]1 SUMMARY OF WORK: 1. Project Description: New Bathhouse as per Section 8.00.03 (E) - Particular Permitted Accessory Structures and Uses in Residential, Agricultural, and Planned Unit Development Districts. 2. Work Involved: a. Interior walls: i. New interior walls of 3-5/8" MTL studs, 5/8" drywall, batt insulation (R-11) around all mechanical areas and bathrooms. b. Exterior Walls: i. New 8" CMU with PT furring strip and 5/8" drywall. ii. Provide MIN R-5 rigid board insulation. iii. Provide new hurricane impact resistant windows and doors per plans. c. Interior ceilings: i. New 5/8" Drywall ceilings, painted. ii. Provide crown molding as shown, style to be selected by owner d. Mechanical: i. Provide new AHU & CDU units as shown. e. Electrical: i. Provide lighting and power, per plans. ii. Provide new appliances as shown. f. Plumbing: i. Provide new plumbing service as shown. ii. Plumbing fixtures as selected by owner. g. Roofing: i. Provide new concrete "S" tiles as shown. New tile shall match existing main residence 3. Work completed shall meet all local and state building code requirements. COORDINATION: 1. Contractor shall verify existing site conditions of project location prior to commencement of work. 2. Contractor shall coordinate and verify all utility requirements, compatibility and location of projected utilities of project, as shown on the drawings. 3. Contractor responsible for coordinating all trades to complete work. Contractor shall issue full sets of drawings to sub- contractors commissioned to complete the work. 4. Contractor shall verify space requirements and location of project utilities. 5. Contractor shall field verify all dimensions of project. Do not scale drawings. 6. Contractor shall notify Architect of any discrepancies in drawings and/or specifications of project. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work preformed. 7. Contractor shall notify the Architect, when the full intent of the drawings and/or specifications is not clear. Commencement of the work without proper notification to the Architect, the contractor will assume responsibility of work preformed. 8. Owner and Contractor shall coordinate Schedule of Values, Application of Payment, Construction Cost and any other fees related to this project. 9. Owner and Contractor shall coordinate Schedule of Construction and notify Architect of schedule. CHANGE PROCEDURES: 1. Architect will submit Supplemental Instructions for minor changes. 2. Contractor may propose changes by submitting a request for change to Architec.l . Architect and Owner shall give written approval for all changes made by the Contractor. Commencement of the work vjithout written approval from Architect and Owner, the contractor will assume responsibility of work preformed. SUBMITTAL: 1. Prior to construction Architect and Owner shall submit a list, to the Contractor of required shop drawings submittals for this project. 2. Prior to construction Architect and Owner shall submit a list, to the Contractor of all required testing for this project. Contractor shall be responsible for the cost of any testing requested by the Owner. TEMPORARY FACILITIES: 1. Contractor shall provide and maintain access to the site of the project. 2. Contractor shall coordinate with Owner for temporary facilities requirements, if required for this project. 3. Contractor shall be responsible for maintaining a clean and safe construction site. 4. Contractor is responsible for the removal of all construction debris. MATERIALS: 1. Store and protect all project products and materials in accordance with manufacturer instructions. Products and materials of this project shall be installed free of damage. 2. Architect shall approve all product or material substitutions. CLOSEOUT: L. Contractor shall notify the Owner 30 days prior to the date of substantial compl,­.ion. At the time of substantially complete, Contractor shall submit a list of items (punch list) to be completed ol orrected within the final days of construction. Owner and Contractor will set the project completion date. 2. Owner and/or Architect will make an inspection with seven (7) days of receipt cal substantially complete punch list. Owner and/or Architect may add items to complete or correct prior to final completion. 3. Contractor shall leave site clean and free of any construction debris or equipment at the end of the project. 4. Contractor shall give Owner operating instructions for the mechanical, electrical, and other operating equipment installed for this project. 5. Contractor shall submit to the Owner all warranties, operating and maintenance manuals for the following products and equipment: a. Termite Soil Poisoning b. Roof System c. Impact Resistant Doors and Windows d. HVAC unit(s) e. Finish Hardware, Keying system f. All installed Flooring g. Toilet Accessories 6. Owner may request additional warranties for other products. Contractor will be (jiven notice prior to work. DESIGN PARAMETERS: 2007 Florida Building Code, With 2009 Amendments 2007 Florida Residential Code 2007 Florida Existing Building Code 2007 Florida Plumbing Code 2007 Florida Mechanical Code 2007 Florida Fuel Gas Code 2008 National Electric Code 2007 Florida Accessibility Code (Chapter #11 2004 Florida Building Code) 2007 Florida Energy Code (Chapter #13 2004 Florida Building Code) 2004 Florida Fire Prevention Code (Based on NFPA-1 & NFPA 101 - 2003 Edition) 2002 National Fire Alarm Code - (NFPA-72) 2002 Fire Sprinkler Code - (NFPA-13/13R/13D) 2002 Standard for Automatic Fire Suppression Systems (NFPA-17/17A) 2000 Standard for Safeguarding Const., Alterations, & Demo Operations (NFPA-241) 2001 Commercial Hoods & Ventilation - (NFPA-96) Building Design: Basic Wind Speed: Building Category: Wind Importance/Use Factor: Internal Pressure Coefficient: Building Mean Height: Roof Overhang: Roof Pitch: Garage Design Pressure: 120 sgft. Door Design Pressure: 50 sgft. Window Design Pressure: 20 sgft. Exposure: Design Loads: Impact Protection: OCCUPANCY: R3 One -Family Residence Enclosed 140 mph 3 second gust II 1.0 +/-0.18 20'-0" 1'-611 6:12 Int. Zone (+26.3/-29.3) Ext. Zone (+30.0/-36.7) Int. Zone (+31.6/-34.6) Ext. Zone (+31.6/-39.8) Int. Zone (+33.7/-36.7) Ext. Zone (+33.7/-44.0) C Roof Dead Load/Live Load: 15/40 psf Floor Dead Load/Live Load: 15/30 psf New Doors and Windows - Hurricane Impact Resistant CONSTRUCTION: Type VB Unsprinklered Ext. brg walls- CMU Eng. wood trusses Int walls-MTL stds & drywall Roofing Material - Concrete S-tile to match existing residence, AREA TABULATIONS: Ground Floor A/C: 420 sgft. Second Floor A/C: 420 sgft. TOTAL A/C: 840 sgft. Loggia: 115.5 sgft. Balcony: 115.5 sgft. Total Bldg. Area: 1,071 sgft. TI 1 5 ' L.NS HAVE BEEN REVIEWED IN ACCORDANCE WITH THE FLORIDA BUMING CODEV PLANS AND ALL PROPOSED WORD SUBJECT TO ANY CORRECTIONS ' Q'JIRED BY FIELD INSPECTORS THAT 1 BE NECESSARY IN ORDER TO 'MPLY WITH ALL APPLICABLE CODES. SCANNED BY ST LUCIE COUNTY ST. LUCIE COUNTY BUILDING DIVISION R9VIEWED FOFi C �� REVIEWE l DATE P NS PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL 13E MADE NDEX OF DRAWINGS Revised 12-Jan-12 Sheet Sheet Titl A0.1 Cover Sheet, General Information & Notes Al.1 Site Plan Notes A2.1 Floor Plans & Notes A2.2 Roof Plan Reflected Ceiling Plans & Notes A2.3 Schedules, Details & Notes A3.1 Exterior E evations & Notes A3.2 Building Sections & Notes S1.1 Foundation Plan, Details & Notes 52.1 Secon Floor & Roof Framing Plans, Details & Notes S3.1 Struct ral Details S3.2 Structurali Notes 0 M2.1 Mechanicol Plan, Schedules, Details & Notes P2.1 Plumbing Plan, Schedules, Details & Notes E2.1 Lighting Ian, Details & Notes E3.1 Power Plan, Details & Notes SYMBOLS O Win ow AX.x Detail ## Door ## Keyed Note Revision 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 12-Jan-12 06-Dec-11 12-Jan-12 XX-XX-XX 12-Jan-12 12-Jan-12 XXx ROOC'i Name Interior Elevation xx.x S> Wall Type XXx� Exterior Elevation A# Wall Sectionx � Building Section PROJECT CONTACTS OWNERS: ARCHITECT: Dr. John Afshar Crossroads Architecture Inc. 511 NW Winters Creek Road Niki L. Norton, R.A. Palm City, Florida 34990 1235 SE Indian St., Ste. 103 (772) 334-9660 Stuart, Florida 34997 (772) 287-7330 I i '­� i M III CONTRACTOR: Watlee Construction, Inc. Ryan N. Watley P.O. Box 1537 Port Salerno, Florida 34992 (772) 223-0604 L UL>-�JL..+�i ������o ran 0', 3 vc-"roLn Q. O.O -0 - C i, raa � ' _'! aUi � a��c Tc�O�a�-OG) UC�LC 4J Ern-rbo- @ v�' �vuo D 3 a c�w _�n L Ln L L �cLNOpNi 0- 0 ULQ 3U_� 3:- � '; 0cao U 'J LIt U:La.g <s0n�3ao3 V '_� � o � �..� O N CV M al N 00 00 N n Z3 ®ice 00 CA 4-J O (N0 (V N U 00 Q) �0 N CT I\ d Q :ram i L_ _ :4-1 � a C v N al (n - Q -0 ro ® o -0 L ra J c L_ zw0u- Q E(� •- N :3 4D UO U z . cn cn CL W fo V o ON rn (Y'i U fo fo L _r_ a--J 0 4- - < s i; M z ((n n E N < [] Ln 0- Rev. Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet A0n1 Cover Sheet LOT COVERAGE CALCULATIONS AIR CONDITIONED AREA 1ST FLOOR A/C AREA 3,230 SQFT ENTRY 82 SQFT GARAGE 824 SQFT LOGGIA 150 SQFT COVERED LANAI 259 SQFT * NEW BATHHOUSE - A/C AREA 420 SQFT * NEW BATHHOUSE - LOGGIA 115.5 SQFT TOTAL STRUCTURE COVERAGE 5,080.5 SQFT EQUIPMENT AREAS 207 SQFT DRIVEWAY 2,676 SQFT * POOL DECK - MODIFIED 2,843 SQFT 'AL COVERAGE 10,806.5 SQFT LOT AREA 27,584 SQFT ALLOWABLE COVERAGE (27,584 x .40) = 11,033.6 SQFT SQUARE FOOTAGE CALCULATIONS AIR CONDITIONED AREA 1ST FLOOR A/C AREA 3,230 SQFT SECOND FLOOR/BONUS ROOM * NEW BATHHOUSE (2 STORY) ZN 2,218 840 SQFT SQFT SUB TOTAL A/C AREA 6,288 SQFT GARAGE (FOR DEHUMIDIFICATION) 824 SQFT TOTAL A/C AREA 7,112 SQFT NON -AIR CONDITIONED AREA ENTRY 82 SQFT LOGGIA 150 SQFT BALCONIES 269 SQFT COVERED LANAI 259 SQFT * NEW BATHHOUSE LOGGIA 115.5 SQFT TOTAL NON A/C AREA 875.5 SQFT LEGAL DESCRIPTION Lot G. RIVER POINT VILLAGE, HARBOUR RIDGE PLAT NO. 20, according to the Plat thereof, as recorded in Plat Book 31, Page 12 to 12B, Public Records of St. Lucie County, Florida. GENERAL NOTES / 1. Soils shall be termite treated. / 2. Landscape design and drawings by others. / 3. Contractor to verify all utility connections as required. 4. Bathhouse has been designed to meet all of the requirements of the Harbour Ridge Architectural Review Board. / MOTOR COURT / rJu2012AN ST. LUC1E / i , i EXISTING TWO-STORY RESIDENCE, .01 SPA / POOL x / BATHHOUSE 00 1 RELOCATED EXISTING POOL EQUIP. FIELD VERIFY NEW LOCATION e _ _ s _ 10'-0" SETBACK LINE 2 3 �— -- -- -- --- _— -- P.L.=225.04' SITE PLAN POOL DECK v SCALE: 1" = 10'-0" �IAY BE NECESSARY IN k,)" (OviPLY WITH A� L APFLICAELE C El O C �N � O O � L._ O f6 to aaO�y Ci.+ E0�a.}O'C L U O L = 2,CE 0'V _�'@ C— O �OOV.L LUOC:E 3Z2C=;w n 'D OL E�e�n,,_, =off-aU=< U L -0U, �� < OL-03m3 U Ou C_ .­0 1.. H O N Mrn N M 0) 00 L M N 00 n O N 00 00 4-J O N N N U 0� N N Q 0'- r, r, L _ Q cn _0Q o� 70 09 A 0,0 c ru ru O -p L L. _� o V) U O M ~ zUj0 /n ® Cl) E Jt!) L O E M E" ro O .— N 4-J U U Z ,-i Cn V) Q� _ Ln 0 U a� V 0O � �rn � �rn -0 — U ra -0 L L O fu i 4 ®� d- fo �.-M 0 -� z .-. E N Q ® urn a .-. GO Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions 3 18-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet Alml Site Plan -V-4" 1-1/2" 0 R, RAILING A - HIGH WITF TO REJECT A 2 FAI N 1-1/2" 0 HANDRAIL 3'-0" HIGH HANDRAIL TO REJECT A 4" SPHERE HANDRAIL ELEVATION SCALE: 1" = V-0" � ~ I I I 3 --- — — — 10 — — - %o 6„ o — I I I J - > 00 -1 1 (D N z p m - }N CLOSET o loz — 102 T Dig = REF ioz i CLOSET 103 SUB D PNL - -L - �D _ -I j EWER I BATHHOUSE I — 1o1 12'-0" o io LOGGIA I I I I I I V-4" 100 4'-2" - BATH -- 4 104 0O r' o 1O 1 UP 4'-5" GROUND FLOOR PLAN 5'-7" O 5'-7" 20'-0" 25'-6" (BUILDING OVERALL) 3 A3.1 4'-5" 4'-2" 5'-6 V-4" ON SCALE: 1/4" = V-0" A WALL LEGEND New 8" CMU Walls - Walls shall receive P.T. furring strips W/ 5/8" GYP. BD. & min. R-5 rigid board insulation. Exterior finish shall be stucco to match existing residence. New Interior Framed Partitions. GENERAL NOTES 1. Field verify a I exis ing dimensions and utilities prior to construction. Notify Architect of any discrepancies. 2. Dimensions are to raming. 3. Cabinetry shall be raftmaid, Omega or approved equal. NO particle board cabinetry. 4. Cabinetry hardwar shall be selected by Owner. 5. Countertops shall be granite or solid surfacing. Color to be selected by Owner. 6. New plumbing fixt res to be selected by owner. 7. Bathhouse has been designed to meet all of the requirements of the Harbour Ridge Architectural Review Board. 4'-5" A3.1 I 1 25'-6 (BUILDING OVERALL) 20'-0" 5'-7" 5'-7" \rI `vI 2 A3.3 4'-5" I 4'-5" 101, . 6" \ / I I I I I I w o O i Z J m 0 -------------- I I I STORAGE �? I - 6" BALCONY 106 lOSe � i0 � o In DIN k Ln o I I / — — — — — — — — — — — — — — I \ o 1r r� o o A 4'-5" SECOND FLOOR FLAN <,, Q 1 A3.3 5'-7" 5'-7" 4'-5" 4'-5" 10" 3" 20'-0" 5'-6" 25'-6" (BUILDING OVERALL) REVIS101i 3 A3.1 N AND ALL PROUSED M)kK SCALE: 1/411 = 11-0 0) P 'E `,�BjECT TO ANY CORRECTIONS R :QUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODL5. m� T° .L �Ln 41� �-(170- ,-+ Ci-+ co ra m -C 0- (a E '0-=oEuyc ---i.o�-0C�3v 0) �v'oc:sa3 �LEacn,, )Z L p�000cU n COJ-.L OOQ - ° � o 3°w°� Vic° 0 Qs3a-o3ro3 OL C: .-10 �—. �. O N M 0) N M M 00 M N 00 CD � 00 00 4-J O N N N V �°,-°N Q� L- _ a N c Q) 0) 0 �� ro W C ® �C�(a ru e O -0 L ro -J L- ZLu0� E 0 - Ln (i) ru E Mt' .— N :3 4-1 UO U Z U) r) U c a L L n cr 2 J - W � V 0o 0') -0 L M •— U U fu f0 ��LID 4-, O - -� o z .� C� I E N L f Q ® Ln a-�✓ L� Rev. # Date 1 06-Dec-11 Bldg Dept Comments Z 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet A2ml Floor Plans r--- CLOSET. CLG HEIGHT - 8.'-JV 'CLOSET .. 1D3 CLG HEIGHT 1X4 T&G CEILING FINISH TO BE. SELECTED BY. OWNER . 5ATHHOUSE CLG HEIGHT .8'-0' 518"'PTD GYP.L:, BD: CLG. :. CROWN MOLDING, GROUND FLOOR REFLECTED CEILING PLAN SCALE: 1/4" = V-0" SCALE 0- N 1/4" = 1'-0" ROOF GENERAL NOTES 1. New ro f the to match existing roof tiles of main residence. 2. Install ew r of tiles as per Miami Dade County N.O.A. 3. Provide roof russ shop drawings for Architect and Engineer approval prior to fabrication. RCP GENERAL NOTES 1. Provide 1X T .G ceiling at new loggia as shown. Finish shall be selected by Owner. 2. Refer tc� E2.1 and E2.2 for all light fixture, ceiling fan, and junction box locations. 3. Providell and i stall crown molding as shown. Size, profile and finish color to be selected by owner. SECOND FLOOR REFLECTE CEILING PLAN BALCONY 106 it ; SE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, -A�N SCALE: 1/4" = V-0" aa�E�3auavi PLC L�uOC.v��i E {n yJ C Ov¢ CL 3 O'f> �u� USN N � fZCO:3 u0vT0 ��y�vYa U — QJ 0�— <Cs3ao3m3 e V �\ O_u H O N M O� M O� 11 OQ M DD h h O r11 U lD N N N Cr .® Q Q U U, M N � C C cu fu ® _ O Lp ra L r- U O '—'' CO — I— ZUJOcu ® —u' Ul 'q 4-J E i Ln (U E;�M� U U Z C� U iJ " L U t. � � ' Q T7 0'_ Ln J L U W � U O W .® V/ U L U')-0 O 4--, 01,0 V) C: LL Q O z UO) n E 4— i- -I ra <,( 0 Ln a- Rev. # Date 1 06-Dec-11 Bldg Dept Comments Z 12-1an-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet A2m2 Roof & Ceiling Plans O DOOR SCHEDULE:: DOOR SIZE DOOR FRAME NOTES: NO. -- (SEE NOTES BELOW) WIDTH HEIGHT THICK MAT. FINISH HDW. TWE ELEV. MDL# MAT. FINISH T'HOLD 101 15'-0" 6'-8" 1.75 AL FAC SLIDER AL FAC AL 1,2,3,4,5 102A 2'-8" 6'-8" 1.375 WD PTD POCKET WD PTD 1,2,3,4,5 102B 2'-8" 6'-8" 1.375 WD PTD POCKET WD PTD 1,2,3,4,5 104A 2'-8" 6'-8" 1.375 WD PTD POCKET WD PTD 1,2,3,4,5 104E T-0" 6'-8" 1.375 AL FAC FRENCH AL FAC AL 1,2,3,4,5 105A 3'-0" 6'-8" 1.75 AL FAC FRENCH AL FAC AL 1,2,3,4,5 105B 5'-0" 6'-8" 1.75 AL FAC FRENCH AL FAC_ AL 1,2,3,4,5 DOOR LEGEND SCW SOLID CORE WOOD HCM HOLLOW CORE METAL BRN BRONZE ANODIZED FINISH BE BI-FOLD SCM SOLID CORE METAL MTL METAL DOOR FRAME/DOOR ANO CLEAR ANODIZED FINISH PKT POCKET GL TEMPERED GLASS DOOR WD WOOD DOOR FRAME FAC FACTORY FINISH PTD PAINTED HCW HOLLOW CORE WOOD AL ALUMINUM DOOR FRAME MFR MANUFACTURER RECOMMENDED FBR FIBER GLASS/ INSULATED STD STAINED FINISH NOTES: 1. DOOR HARDWARE TO BE SELECTED BY OWNER. 2. INTERIOR DOORS AND FRAMES, STYLE AND FINISH TO BE SELECTED BY OWNER. 3. DOOR CASINGS TO BE SELECTED BY OWNER, 4. ALL EXTERIOR DOORS SHALL BE HURRICANE IMPACT RESISTANT BY PEACH TREE OR APPROVED EQUAL. 5. INTERIOR DOOR STYLE AND PROFILE TO BE SELECTED BY OWNER. FINISH SCHEDULE ROOM ROOM NAME FLOOR', WALL BASE WALLS OTHER FIN. CEILINGS CROWN MOULDING NOTES: BELOW) NO. (SEE NOTES TYPE TYPE N E S W MAT'L. HT./A.F.F. FINISH MODEL# 100 LOGGIA BFC PS PS PS PS T&G 8'-0" - - 3 101 BATHHOUSE CT PWD PGW PGW PGW PGW PGW 8'-0" 1,2,3 102 CLOSET CT PWD PGW PGW PGW PGW PGW 8' 0" 1,2,3 103 CLOSET CT PWD PGW PGW PGW PGW PGW 8'-W 1,2,3 104 BATH CT PWD PMRGW PMRGW PMRGW PMRGW PGW 8'-0" 1,2,3 105 STORAGE CT PWD PGW PGW PGW PGW PGW T-8"/W-8" 1,2,3 106 BALCONY BFC PS PS PS PS - FINISH LEGEND BFC BROOM FINISH CONCRETE PWD PAINTED WOOD MOULDING, BASE 71/4" PROFILE, OR TRIM 4" PROFILE WD WOOD FLOOR FOR WINDOWS AND DOORS MARBLE 1/2" MARBLE (AS SELECTED BY OWNER) SWD STAINED WOOD MOULDING, BASE, OR TRIM CT CERAMIC TILE (AS SELECTED BY OWNER) PS PAINTED STUCCO CT COVE CERAMIC TILE COVE BASE PGW PAINTED GYPSUM WALLBOARD (5/8" WALLS & 5/8" CLGS.) (AS SELECTED BY OWNER) PMRGW PAINTED MOISTURE RESISTANT GYP. WALLBD CPT CARPET (AS SELECTED BY OWNER) DU DUROCK FOR SHOWER WALLS CD COOL DECK FINISH T&G CEILING FINISH TO BE SELECTED BY OWNER NOTES: 1. PROVIDE MOISTURE RESISTANT DRYWALL AT KITCHEN SINK AREA, LAUNDRY SINK, WASHER. 2. PROVIDE DUROCK OR EQUAL AT SHOWER WALLS AND FLOORS WHERE TILE WILL BE APPLIED. 3. REFER TO REFLECTED CEILING PLAN FOR CEILING CONFIGURATIONS. ;. .4 G d. 5/8" MIN. STUCCO ° }" MIN. STUCCO ` •. RIGID INSUL. FINISH ° FINISFI ^: (R5.4) CONCRETE BEAM OR d PRE -CAST LINTEL - ° 1/2" GYP. BD. CMU LINTEL -SEE \" GYP. BD. REFER TO STRUCT. DWGS ° .; LINTEL. SCHEDULE ' & BUILDING SECTIONS :a a ° FLASHING r... ° FURRING STRIPS FLASHING �,,. FURRING STRIPS @ 16" o.c. HORZ. @ 16" o.c. HORZ. 2x P.T. WD. BUCK ° d 1/4" TAPCON n! 2x P.T. WD. BUCK 1/2" TAPCON w/ FASTEN TO CMU 1-1/2" EMBEDMENT FASTEN TO CMU 1-1/2" EMBEDMENT 3/16" TAPCON w/ INLLLO CONC.-S" c,c #10 SCREWS- 1-1/2" INTO CON[. 8" O.C. 1-1/4" EMBEDMENT EMBEDMENT INTO INTO CONC.-PER HOLE FIJI. WOOD WOOD -PER HOLE FIN. WOOD CA':ING CASING HEAD FRENCH SLIDER -SEE --t' H EAD DOOR -SEE PLN DOOR SCHEDULE EXTERIOR INTERIOR EXTERIOR INTERIOR DOOR -SEE PLN FRENCH SLIDER -SEE 1/4" TAPCON w/ DOOR SCHEDULE 1/2" TAPCON w/ 1-1/2" EMBEDMENT 1-1/2" EMBEDMENT #10 SCREW -STAGGERED #10 ]AM INTO CONC.-8" ox. #10 SCREWS- 1-1/2" JAMB INTO CONC.-8" O.C. EMBEDMENT EMBEDMENT INTO INTO WD.-PER HOLE FIN. WOOD WOOD -PER HOLE FIN. WOOD CA'3ING CASING CHAULK @ FRAME CHAULK @ FRAME CONT. CONT. 2x P.T. WD. BUCK FURRING STRIPS 2x P.T. WD. BUCK FURRING STRIPS FASTEN TO CMU ;: VERTICAL @ END FASTEN TO CMU VERTICAL @ END FLASHING FLASHING GROUT FILL CELL 1/2" GYP. BD. GROUT FILL CELL \" GYP. BD. #5 BAR @ ALL �'' #5 BAR @ ALL �' RIGID INSUL. OPENINGS OPENINGS (R5.4) DOOR -SEE PLN THRESHOLD PER FRENCH SLIDER -SEE THRESHOLD PER MANUFACTURER DOOR SCHEDULE SIL MANUFACTURER SIL GROUT FILL 3/16" TAPCON w/ GROUT FILL 3/16" TAPCON w/ 1-1/4" EMBEDMENT 1-1/4" EMBEDMENT INTO CONC.-PER HOLE FLOORING- SEE FIN. SCHEDULE INTO CONC-PER HOLE rf- FLOORING- SEE FIN. SCHEDULE SLOPE WALK AWtAYC FROM OPENING CONC. SLAB - e °� SEE FDN PLN 1/2" FIBEROUS EXP. JOINT EXT FRENCH DOOR EXT. DOOR H—S-1 DETAILS SLOPE WALK AWAY FROM OPENING - D CONC. SLAB - ;, e . Q ; eu . •� . D SEE FDN PLN 1/2" FIBEROUS 6 4 EXP. JOINT •. /D FRENCH DOOR SLIDER SCALE: 1-1/2" = 1'-0" (2) 2x6 WD. HDR ADJUST HEIGHT FOR TRACK 2x4 WD. BUCK - TRACK PER MFR, WD. DOOR -SEE DR. SCHEDULE HEAD CAULK FULL FRAM PERIMETER, TYP. WD. DOOR FRAME SIZED TO WIDTH OF WALL WD. DOOR -SEE DR. SCHEDULE JAMB WD. DOOR -SEE DR. SCHEDULE THRESHOLD -SEE FIN. SCHEDULE 5/8" GYP. BD. BOTH SIDES, TYP. 1/2" WD. SHIM -FINISHED WD CASING SIZE WD. BLKG• FOR TRACK PTD. GRADE WD. FRAME " GYP. BD. -H SIDES, ISHED WD SING ). GRADE FRAME FLOORING -SEE FIN. SCHEDULE o ° e CONC• SLAB - SEE FDN PLN SILL POCKET DOOR INT. DOOR H—S—J DETAILS SCALE: 1-1/2" = 1'-0" WINDOW SCHEDULE WIN TYPE OWIDTH SIZE HEIGHT ROUGH OPENING WIDTH HEIGHT MUTTINS COLOR ELEV. FINISH WINDOW HARDWARE ^`ANUFACTURER 15TYLE) MODEL #/SERIES TYPE NOTES: (SEE NOTES BELOW) A 2'-6" 5'-2" VERIFY VERIFY TBD A TBD TBD PEACH TREE CASEMENT 1,2,3,4,5,6 C 2'-6" 4'-6" VERIFY VERIFY TBD C TBD TBD PEACH TREE CASEMENT 1,2,3,4,5,6 D 4'-8" 4'-6" VERIFY VERIFY TBD D TBD TBD PEACH TREE CASEMENT 1,2,3,4,5,6 NOTES: 1. NEWWINDOWS 2. 5.7 3. VERIFY 4. ALL 5. REFER 6. ALL QFT FO WINDOW DIMENSIONS TO BL WINDOW SHALL BE PEACH TREE WINDOWS AND DOORS OR APPROVED EQUAL AND HURRICANE IMPACT RESISTANT. EGRESS FOR ALL BEDROOMS AND LIVING AREAS. ROUGH OPENINGS WITH WINDOW MANUFACTURER. ARE NOMINAL (MASONRY OR ROUGH) DIMENSIONS, SHOP DRAWINGS TO BE PROVIDED FOR ALL UNITS ALONG WITH FIELD DIMENSIONS. ILDING ELEVATIONS AND WINDOW TYPES FOR WINDOW CONFIGURATION. FINISHES SHALL BE SELECTED BY OWNER. 2'-6" `O WINDOW TYPES TI? F Pg.r'�5v. ND ALL PROPOv �j `d A')F suB.IECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODE . ,j AND ALL PROP 5ED T TO ANY CORRE TIO D 31 Y FIELD INSPECTO ZS T! . NECESSARY IN ORDE TO ALL APPLICABL CC 2'-6" 2'-0" i0 �M ADELETED 5/8" MIN. STUCCO FINISH ; CMU LINTEL- SEE BEAM SCHED. D FLASHING 2x P.T. WD. BUCK, FASTEN TO CMU CHAULK @ FRAME CONT. WINDOW -SEE PLAN kD 6�1111 WINDOW -SEE PLAN SLOPE STUCCO SILL F AWAY FROM WIN. EDGE FLASHING CMU LINTEL -SEE BEAM/ LINTEL SCHEDULE 9 STUCCO FINISH ° JAM B WINDOW -SEE PLAN CHAULK @ FRAME CONT. 2x P.T. WD. BUCK FASTEN TO CMU FLASHING GROUT FILL CELL ° a #5 BAR @ ALL OPENINGS ALUMINUM WINDOW 4'-8" 2'-4" 2'-4" 0 SCALE: 1/4" = 1'-0" 1/2" GYP. BD FURRING STRIPS @ 16" ox. HORZ. FIN. WOOD CASING 1/2" GYP. BD. w/ CORNER BEAD 1/4" TAPCON w/ 1-1/2" EMBEDMENT INTO CONC - 8" o.c. SPACING FOR ALL FOUR SIDES #10 SCREW -STAGGERED 1-1/2" EMBEDMENT INTO WD.-PER HOLE 2x P.T. WD. BUCK FASTEN TO CMU VERIFY w/ OWNER FIN. WOOD SILL FIN. WOOD TRIM FURRING STRIPS @ 16" ox. 1/2" GYP. BD. VERIFY SILL W/ OWNER 1/2" GYP. BD. FIN. WOOD CASING FURRING STRIPS VERTICAL @ END 1/2" GYP. BD. 1A1TK1n(1\Al W-C-1 rrnr--rATI c SCALE: 1-1/2" = 1'-0" _0 0 N.c °OEaO, c L��'U_ + u vN Q) Uw L c \J roc 6=�U E'o0o uWC 4-J �'o���m� 0) Lruocc3 .L >'a)0+ _ Lc=LE�c�Y NL�� L LC'�� N O O C C U p C Ctv O L r-=LoO-u 0 U— 3 wUN 3� � °�0Q, 0 U�� U' Q� r U 01 u H O N ('') Gi N M Cn Il�' 00 00 O OC)W 4-J ON NN U Zo N N Q) N`n NN Q Q �N✓a�i U L_ _ T C) �p/�� V l Q -J w to LL (Y ) ro 0 ! O-0 _0 U41f O ~ � LL 0 I,zW® E Q)L_ L E UO U z ,-, cl) cn 0 r ti. L U N L d LnI Z i Lf)Ln \ Lq U r W U �o L M U*)U ru 0 0 ,L f T3 r� 'Li.. O z ,--o r^ V J ^ E N 4— '� — f� C�-------------- Rev. # Date 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet A203 Schedules, Notes & Details AMA ROOFING TO MATCH EXISTING RESIDENCE OVERHANG DETAIL TO MATCH EXISTING RESIDENCE IN MATERIAL AND PROFILE 17'-2" T.O. BEAM B.O. WIN. DOOR HEAD STUCCO FINISH TO MATCH EXISTING RESIDENCE RAILING AND RAILING POSTS TO MATCH EXISTING RESIDENCE 9'-6" _ 2ND FLOOR _ — 9'-0" BALCONY 6 8 _ B.O. WIN. DOOR HEAD STUCCO FINISH TO MATCH EXISTING RESIDENCE o'-o_ - — —I--I — 1 - NORTH ELEVATION 3 - SOUTH ELEVATION 12 6 i 12 6 I / \ +45.4 PSF +45.4 PSF - 49.2 PSF - 49.2 PSF O +45.4 PSF - 49.2 PSF +45.4 PSF +45.4 PSI +45.4 PSF =49.2 PSF — 49.2 PSF — - 49.2 PSF— — n i \ +45.4 PSIF - 49.2 PS +45.4 PSF - 49.2 PSF +45.4 PS - AO 7 DC +45.4 PSF +45.4 PSF - 49.2 PSF - 49.2 PSF SCALE: 1/4" = 1'-0" ROOFING TO MATCH EXISTING RESIDENCE OVERHANG DETAIL TO MATCH EXISTING RESIDENCE IN MATERIAL AND PROFILE — — T.O. T.O. BEAM 'r -- — — — — 16'-2" B.O. WIN. DOOR HEAD _ STUCCO FINISH TO MATCH EXISTING RESIDENCE RAILING AND RAILING POSTS TO MATCH EXISTING RESIDENCE 9'-6" 2ND FLOOR BALCONY 6'-8" B.C. WIN. r DOOR HEAD STUCCO FINISH TO MATCH EXISTING RESIDENCE — — 01-011 SCALE: 1/4" = 1'-0" 1 2 GENERAL NOTES_ 1. New windows to match existing existing residence. 2. New roof overhE ng & soffits shall match existing residence in profile and construction. 3. New colurT n capitals and bases to be selected by owner. 4. New roof tiles s all match existing residence in profile and color. 5. Bathhouse has been designed to meet all of the requirements of the Harbour Ridge Architectural Review Board. 12 +43.2 PSF - 47.0 PSF 4 -WEST ELEVATION THESE PLANS AND All PROPSED RREOCiION WORK REQUIRED BY FIELD INSPECTOR THN MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ROOFING TO MATCH EXISTING RESIDENCE '�- — ——17-211 T.O. BEAM 16'-2" B.O. WIN. DOOR HEAD OVERHANG DETAIL TO MATCH EXISTING RESIDENCE IN MATERIAL AND PROFILE \ STUCCO FINISH TO MATCH EXISTING RESIDENCE 9'-611 2ND FLOOR 9'-0" BALCONY B.O. WIN. DOOR HEAD RAILING AND RAILING POSTS TO MATCH EXISTING RESIDENCE STUCCO FINISH TO MATCH EXISTING RESIDENCE ——0'-0.1 SCALE: 1/4" = 1'-0" ROOFING TO MATCH EXISTING RESIDENCE T.O. BEAM OVERHANG DETAIL TO MATCH EXISTING RESIDENCE IN MATERIAL AND PROFILE STUCCO FINISH TO MATCH EXISTING RESIDENCE 9'-6" 2ND FLOOR 9'-0" BALCONY STUCCO FINISH TO MATCH EXISTING RESIDENCE 0'-0" Tn CI AR SCALE: 1/4" = 1'-0" r��mNcc3 �a�� Fco crnrova�-c� &-0- � -�-% E u c) c a2oBu � }�)� a+�,u�ouai�m� �� T L L �a",(Do c ocu C C L N O O O -C 53C3 U.0 Q ® N r-+ IpcO-07 v +.' O T UQ r3a-3ra3 ■ V O LL 1.,s 1—o H O N r'M 0) N M 0) r- UO 00 h � O 1- 00 00 -i--J 0(N N N 0 W Q h V L _ Lu a-' N h C 0) -0 Fli Cz M ® ru 1-- o -a L- fu -J C O (� U ®°-�M Q- z W O LL 0 E JLn L. N EMt' O •— N :3 4-J U C y� Q ro V) U) 0 U V 0 o �0,1 0-1 - ry) •- U flo -0 V) Q� f-a � — Q /5..� V CZ 4-J M ® Z C.n E N ® Ln 0— 0 Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet All Building Elevations 12 6 17'-2" T.O. BEAM r 16'-2" B.O. WIN. DOOR HEAD bo Bo STORAGE BALCONY 105 106 — — — 96_2ND FLOOR _ _.....:.....,•.:, sir, , ,..,;� i.„ 9'-0" BALCONY B.O. WIN. DOOR HEAD o O BATH 00 BATHHOUSE LOGGIA co 104 101 101 01-01, •x :, T.O. SLAB 'r 'q,Gi✓i�iiU, %�iU��i,iri i%'ii�i��iii5i��i i<�iQ�ii�i�G�i��<:c�:eb•:::.«c!.. ..(; ipp��i��i�<„. �i i .\, ��;`� ��?�i`�,`�,�iwa�� ��._. s� ������,��, �,. �. +< a i �� ��j\��✓✓vi.v:�/ii``r��`�, .., ��,. ill �u L1.- BUILDING SECTION A,- : 7 Z - BUILDING SECTION SCALE: 1/4" = 1'-0" i i i 1 I 1 SCALE: 1/4" = V-0" I � I GENERAL NOTES 1. New windo s to match existing existing residence. 2. New roof o erha Ig & soffits shall match existing residence in profile and construction. 3. New column capitals and bases to be selected by owner. 4. New roof tiles shall match existing residence in profile and color. 5. Bathhouse has b en designed to meet all of the requirements of the Harbour Ridge Architectural Review Board. ROOFING TO MATCH EXISTING RESIDENCE PREFAB ROOF TRUSSES - SUBMIT 12 SHOP DRAWINGS FOR ARCHITECT'S 6 APPROVAL MIN R-30 ICYNENE SPRAY INSULATION INTERIOR a INTERIOR r° - n. a .... �.. .. :: .'� �.,. xxx/,vA/�<\ VX�x\: :.. /j/,A�,. 3 - TYPICAL WALL SECTION T.O.— T.BEAM OVERHANG DETAIL TO MATCH EXISTING RESIDENCE IN MATERIAL AND PROFILE CONCRETE BEAM - SEE STRUCTURAL DWGS STUCCO FINISH TO MATCH EXISTING RESIDENCE 8" CMU WALLS 5/8" DRYWALL OVER 3/4" P.T. FURRING STRIPS OVER MIN R-5 RIGID BOARD INSULATION CONCRETE BEAM & 6-1/2" EPICORE CONCRETE DECK - SUBMIT SHOP DWGS FOR ARCHITECT'S APPROVAL 2ND FLOOR EXTERIOR STUCCO FINISH TO MATCH EXISTING RESIDENCE 8" CMU WALLS 5/8" DRYWALL OVER 3/4" P.T. FURRING STRIPS OVER MIN R-5 RIGID BOARD INSULATION CONCRETE SLAB AND FOUNDATION - SEE STRUCTURAL DRAWINGS OVER MIN 6 MIL VAPOR BARRIER CLEAN COMPACTED TERMITE TREATED FILL 0'-0" T.O. SLAB REVISION THESE PLANS AND ALL T CORREOCTIONSSED o� ARE SUBJECT TO ANY REQUIRF� Y FIELD NECESSARY INSPECTORS NORDR TOE.. MAY BEN COMPLY WITH All APPLICABLE CODES. SCALE: 3/4" = V-0" � ro O7LT i�i aoS- i0-0 ra--� I .- C C cn fO v+'L on E -"o- V N C C QIE, C � 0 Po 3-2c��� n •— "O O.U'.,,°i- V; u E D cn � � E 7 cO,4 0. N maw L �E C1i�o0OCCL C CL 43 O C- Oa. -.ice V.CQ 3 V a� v rz 3 -� °� 0 �.E O o TO ■ CO (N N M CT CO M 00 N N 0 N N N U � � N N ; � Q O� Q < r, � v. i U L— _ 4-' 4J C O I`r O� (n ro I� M 0 ®-� L L U) U O i� z w ®'�- E 0 —� on a) E rr� 1M:~' O •—N :3 Z34-+ u L a, 1 Cz� U W V �c �0*1 W � � (y) .� (Ui W U flo �.00 to v .� 4-J 0 1,0 �+ 4L— .0 0) --J M 0 r� V / rn E N Rev. # Date 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet Al2 Building Sections rA J — — — J 9 --� - LU 00 N z O J m 2 S1.1 0 N 7 S1.1 FOOTING SCHEDULE MARK WIDTH x LENGTH T REINFORCING (BOTTOM) WF1 2'-0" x CONT. 18" (3)-#5 LONG WAY BOTT. #5 @ 48" O.C. SHORT WAY BOTT. AO 3'-0" x 3'-0" 12" (4)-#5 EA. WAY BOTTOM T.E. V-0" x CONT. 12" (2)-#5 CONT. 25'-6" (BUILDING OVERALL) 20'-0" 5'_6" 1 S1.1 I I— S1.1 — -- ---- 0 0'-0" SLAB ELEV. _ SLOPE 4" CONCRETE SLAB 6�� � W/ 6X6 W1,4XW1.4 WWF OVER 10 MIL VAPOR BARRIER ON TERMITE TREATED & COMPACTED FILL C.J. 6 (2) #4 X 6'-0" \ 5 77, 6" S1.1 -0'-6" SLABS EL 6 4" CONCRETE S1.1 W/ 6X6 W 1 4X WWF OVER 10 VAPOR BARRIE TERMIT�€TR€� & COM AC ED L_ — 5 S1.1 20'-0" 5'-6" 25'-6" (BUILDING OVERALL) FOUNDATION PLAN DO LAB LAB TERn rE T 11.4 1IL 'ON n f III A m RED COLUMN SCHEDULE MARK SIZE REINF. TIES TYPE CAP PLATE MATERIAL OHSS 4 X 4 X 3/16" - - - - STEEL O 16X16 (4) #5 #3 @ 12" O.C. - - CMU COLUMN BLOCK 3O NOT USED - - - - - 4O NOT USED - - - - - r'.,MFM TREATMENT REQUIRED► N SCALE: 1/4" = V-0" THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODFS. GENERAL NOTES: FOUNDATION PLAN 1. CONCRETE 2a. Alternate for wire mesh: a. shall be Class 1. Fiber mesh made of synthetic fiber manufacturer b. shall meet 5" Slump Test. per ACI 544.IR-82. Fibers shall be a certified suitable c. shall meet 3000 psi compressive replacement for welded wire fabric per SSTD 10-93, strength after 28-day cure. 3. CONCRETE MASONRY UNIT d. Grade floor slab for drainage. a. shall be meet ASTM C 90. e. Finish concrete with single trowel. b. shall load bearing concrete masonry units. f. footing design based on soil bearing c. shall meet 3000 psi compressive capacity of 2500 psf strength after 28-day cure. 2. REINFORCING d. Grade floor slab for drainage. a. shall meet ASTM standards for 60 Grade. e. Finish concrete with single trowel. b. vertical reinforcing shall be 3/4" from See Finish Schedule for floor finishes. masonry. 4. MORTAR c. vertical reinforcing shall extend from a. shall meet ASTM C 270 standards. footing through pre -cast lintels. b. shall be type M. Cl. horizontal reinforcing shall be Cont. for c. joint type shall be concave. pre -cast lintels over openings. d. horizontal reinforcing lapping shall 5. GROUT a min, 22". a. shall meet ASTM C 476 standards. e. protect for reinforcing: b. shall have a min. 2000 psi compressive strength. floor slab: 3/4" min. cover from top c. shall meet 8" -10" slump test. 1-1/2" min. cover from bottom 6. SOIL BEARING CAPACITY footing: 3" min. cover a. shall meet 2500 psf. walls: 1-1/2" min. cover beams: 1-1/2" min. cover V �/ v v v v v v v v v v v #5 REBAR @ EVERY 4'-0" o.c. a @ BOTH SIDES OF ALL Al MASONRY OPENINGS c E L SEE PLANS o > O CONC SLAB FIN FLR FIN GR x x. ( ) #5 CONT iN 3" 3' MIN. COV. & // 5 @ 48" O.C. \\/ /�\/ 2 T4,ANSVERSE 1 BEARING FOOTER SCALE: 1/2" = 1'-0" () #5 EXTEND 24" B YOND W&B ( P•) ---\ I #5 REBAR @ EVERY 4'-0" o.c. E a I @ BOTH SIDES OF ALL MASONRY OPENINGS E SEE PLANS w O I RECESS FTG 4" 12" IFNFLR CONC SLAB I� FIN GR �D r, 4 (1) #5 CONT— ( ) #5 CONT \/ \ 3" �\/\// 3" MIN. COV. 3' MIN. COV. & 5 @ 48" O.C. 2'-0" T ANSVERSE BEARING FOOTER @ SHOWER SCALE: 1/2" = 1'-0" ?" FIBER 7P P JOINT #5 REBAR @ EVERY 4'-0" o.c. a @ BOTH SIDES OF ALL MASONRY OPENINGS E I SEE PLANS - w om O L� �CONC SLAB T STP o ° • x' 4 (3) #5 CONT " MIN. COV. & \ 5 @ 48" O.C. TRANSVERSE � BEARING FOOTER @ EXT STEP SCALE: 1/2" = 1'-0" U) a CONIC SLAB FIN FLR FIN GR (2) #5 CONT MIN. 3" MIN. COV. 1' -0" 4 THICKENED EDGE SCALE: 1/2" = 1'-0" T.E. 1/2" FIBER EXP JOINT CONC SLAB FIN Fes_ EXT STP x '3) #5 CONT \\ 3" 3" MIN. COV. & // MIN.\//\//\/\�%\' #5 @ 48" O.C. "2'-0" TRANSVERSE TRANSVERSE S FRONT ENTRY 1 /4" SAW -CUT 1" MIN. DEPTH CONC. SLAB (TYP. ) x—x—x—x—x—x—x x 6 SAW -CUT JOINT DETAIL SCALE: 1/2" = 1'-0" 12" DIA OR 16" SQUARE COLUMN BLOCK 1' cb #5@12"O.C. I I (T&BOT, �--� 1/4" PMJ SHORT WAY) II I I ALL SIDES #4 NOSING (TYP. ) #23 ..•. (7) #7 CONT STIRRU @ X...x II x';T=,x TOP & 16" O.C. N BOTTOM GRADE SLAB ON GRADE ., :.., . SEE PLAN t_ REINF. CONC. SLAB DOWELS T-0" SQUARE 112" EXP. IT. MAT. W/ HOOKK E EA. END W/ HOOK l l EA. SIDE N (3) #5 CONT. & 2'-0" (4) #5 TRANSVERSE B01TOM COLUMN DETAIL STAIR DETAIL SCALE: 1/2" = 1'-0" ro D UI a2 c; 0 a��c 9choct @ro(0:aroma¢ uum -i_J E.E-0-00 E uy - c0avc�6 �Q)t0 ,03 �v�av�L C 41 ru U, �.� p"CUJ00 CC U C 0� i1, 0L¢ 0 —'S ® Uw0v _ °S0 o0>,0 (3) 0 Q�30.=o3aa3 U 0 1i C: 1_­0 1_1 H ON m rn ^� N m CY) r" 00 L 00 O N 0000 0000 i) O (\J N N U � '�+' N � ri Q n n U Q) rn Q rn � C M Fn 0 � � to ru \ o -a (%' O ~ U_Z Lu O E 0 L 1n a) E m ( O.-N i.� U Z ,-+ U) to ci L w L J E vS a� 0 L) W fu U 0o Ql Q) L M ....� U ro V ^ L (J') -0 fa z Zi O VJ C 0) Q�- C: 4-J rn ® � V J n N �} . rl _ L f Q ® Ln 6-..� Rev. # Date 1 06-Dec-11 Bldg Dept Comments Z 12-Jan-12 Field Revisions Proj 11-0470 NO. Status Final Issue 14-Sep-11 Date Sheet Simi Foundation Plan 0 0 WIND LOAD SCHEDULE COMPONANTS AND CLADDING ROOF WIND LOADS WALL WIND LOADS ROOF AREA WALL AREA 1 2 3 4 5 _ PRESSURE (PSF) 26.2 26.2 26.2 45.4 45.4 SUC110N (PSF) -41.5 -72.3 -106.9 -49.2 -60.8 CORNER DISTANCE, A = 3 FEET ASSUMED TRIBUTARY AREA = 10 SF PLAN ELEVATION *8d NAILS @ 6" O.C. @ EDGES 8L FIELD ZONE Q1 & 4" O.C. @ EDGES & FIELD ZONES 02 & 0 --�TN SCALE: 1/4" = 1'-0" DESIGN LOAD SCHEDULE (ALL LOADS SHOWN ARE IN POUNDS PER SO. FT.) a W a COMPONENT O N U- IX STUCTURE 6.5 EPICORE 80 - STUCTURE TRUSS &PLYWOOD - 8 MEP 5 5 ROOFING - 15 FLOORING 15 - CEILING 3 3 MISC. 2 4 TOTAL DEAD LOAD 105 35 TOTAL LIVE LOAD 40 20 TOTAL LOAD 145 55 NOTE: NET WIND UPLIFT = P.S.F. A M Li � rj -4 r1j U U C7 03 _ � % N CJ5 TJ io Uj 077 1 i I LD cJ� I I I� 07 SLOPE 6:12 CJ ox I 002: CJ7 I o 1 Wo W N 05 z �1 z L J Lu U v7 Uj 03 2ti�G a 01 r-I M Ln U U U ~ ~ ~ ROOF FRAMING PLAN CN Ln (J U M U U /cj 4 03 I II CJ 5 1 I CJ7 m I I cn SLOPE 6:12 II CJ7 � c7 II 07 I� 07 II I 05 ?T� 03 4 _ _ _XU6 N Ln U (M U 6 S3.1 TYP. 4 SIDES THESE PLANS AND ALL PRU�U:,,tu tidU ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. -�WN SCALE: 1/4" = 1'-0" O ac'O-0 -c ° E'co a uJ UL +'C � � L C 0 _ E���EU0 r'L C ru r �°fu .i i.w ° L UI�U C �f� 3 E D c Q�i�C.0 N o-^u°°CCE co-c(U°U¢ uL 3 uw a a 3, ,uc°Lv)c ° ® UOi0 OUT O N U a _ O L N QL3a�3 a3 ( a� 0 U- c�. 11-. �....� O N M � M h 00 00 h t� O h 00 � O N N fN U Q h h Q Q U L _ Q t!i .o Q ,., Cy) M C)� N [a 0 0 -� -0 v) u O MIy ~ Z W O 0 N (n •-+ E I- In a) E1M4' rO 0 •-) U U z V) ui L U -1 4-1 J QDI L �J O \\ V 0 L. W � M U AV I , — 0 V) c: Q (� 4-J U CM r1 4— — {� Q 0 LnDT�. Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet S2ml Framing Plans (1) #5 (-ONT. @ SILL HOOK IrdTO JAMBS T.O. DECK 9'-6" 4 • Y •LOPE a • •-. �.. ., .. F •. BEAM B-1 ri 1. �� • �. ° r w• `� 8F16 1T/1B °•�'�- �^ =� •IN'• :' • s. - T.O. DECK 9'-6" BEAM B-2 SEE PLAN FOR VERT. „ REINF. HOOK INTO LINTEL WHERE ABOVE OPENING 8F8-1E,, TYP. FOR OPENINGS UP TO 48" WIDE (1) #5 CONT. HOOK • m `— INTO ,IAMB (TYP.) ,• SEE PI AN FOR VERT. •1 REINF HOOK IN-0 SILL WHER> REINF. IS BELOW '. .� WIND()N 2 - WALL SECTION DETAIL 3 - WALL SECTION DETAIL BEAM B-2 5/8" CDX EXTERIOR PLYWOOD ATTACHED W/8d NAILS @ 6" O.C. FIELD & EDGES ZONE (1) 4" O.C. FIELD & EDGES ZONE (2) & (3) 12 (7) #7'S T&B CONT. FROM STAIRS 6 HOOK TOP BARS INTO B-5 BEAM ATTACH PLYWOOD TO BLOCKING \� W/8d NAILS @ 4" O.C. (TYP.) m (n T.O. DECK 9'-6" ollb 2X BLOCKING TIGHT BETWEEN w � w p:.,. -• .X . X .-�— Y EACH TRUSS &TOE NAIL IN PLACE ° V m °:. ° w g Q 4— =a—=: r. s -z�-:� - t Ln•'• a.. •OIL • d;-_.0 •. ° PRE-ENGINEERED BEAM DTRUSS @ 24" BEAM B-3 O.C. MAXI bj,(2) #6 TOP EXTEND TO L� BEAM B-5 - END OF CANT. BEAM & CANTILEVERED BACK INTO B-2 BEAM BEAM MIN 60" SIMPSON HETAL-16 BEAM B-4 (TYP.) UNO I 16X16 MASONRY . �•(2) #5 EXTEND TO END 8" CMU -SEE PLAN FOR COL. @CORNERS OF CANT BEAM REINFORCING (HOOK INTO • TOP OF TIE BEAM ,l BEAM B-2 12" 0 COLUMN ■ SCALE: 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SEE PLAN FOR REINFORCING STALE: 3/4" = 1'-0" L 4 - STAIR LANDING DETAIL 6'-7" SEE FLOOR PLAN BEAM B-2 BEYOND 00 b 1 .: �'ir.r'•�",NOW OW NEW I Q •� BEAM B-5 (8 X 12) END OF WALL SCALE: 3/4" = 1'-0" (7) #7 T&B T.O. DECK 9'-0" I Cb \� #5 T&B @ 16" O.C.A- TEMP. STEEL (7) #7 T&B �4�*V 5 - STAIR LANDING DETAIL SCALE: 3/4" = 1'-0" 6 - OVERHANG SE ION DETAIL SCALE: 3/4" = 1'-0" ir(1 E PLANS AND ALL PROPOSED WORK �RE SUBJECT TO ANY CORRECTIONS E9,UIRFD BY FIELD INSPECTORS THAT ESSARY 'IN ORDER TO COBE COMPLY NW TH ALL APPLICABLE CODES. CO m= .L •� c� J-� WO 0-0- c v �oEo3aQ)4-; �.D �� +mac �cV�ctuoi c L 0 o Em�-ooEu�c 3� �c�wpvr a NjE Tv O L U Cu Um Wa a) ro-aEocn- > 1 �oo o- m`^oocc� co=C' ood � ® .3 u.c uOa�o 3,, °•Eo-oaci>.o <c�3a�3rH ■ V , -' O� C- f■■1 O N M 0) N M Ol f 00 -° M or, 0000 4-J C:) N N N 0 00 UO /ryV j W N N , Q Q L— _ Q C= (ll Q L- CY) fa O Io O -a _U J C 1- O (n V O~M 4J z Lu O LL- V) O E—'�a)� E M±' 10 O - N :3 4-J U U U)(f) c t�! v 7 �-v � � a a t0 \ Q 0 U W fa V 0O C 0 Q L — U U)-0o fa �•L�D - 4-J ® kD w C: Q �M - SUM n L ra Q Ln a- 0 Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet S3m1 1 �( Structural Details A, GROUND FLOOR MECHANICAL FLAN MECHANICAL LEGEND Supply Diffuser-4 Directional L= Damper Supply Diffuser-1 Direction ■❑ Exhaust Fan `4 Supply Diffuser- Wall Register Rigid Duct XXX CFM Amount of CFM Supplied Flex Duct __!�WN SCALE: 1/4" = 1'-0" A GENERAL NOTES: MECHANICAL 1. Contractor shal verify all duct sizes and consult Energy 6. Diffusers shall be selected by owner. Calculations pri it to installing A/C system. 7. Provide bird & bug screen for exhaust and make-up air 2. Provide cc nden ration drain for air condition unit from attic. grilles @ soffit. As shown on plz ns. 8. Provide safety switch for exhaust fans. 3. Locate ThermoThermoE tat per owner's direction. Manufacturer 9. Bathroom exhaust and fresh air intake are more than selected by ow er. 10' apart. 4. Flex Duct shall )e insulated flexible duct. 10. Ducts in the garage and ducts penetrating the wall or ceilings 5. All main duct tr ink lines shall be 1-1/2" heavy duty fire separating the dwelling from the garage shall be constructed retardant / glz ss reinforced foil faced scrim. of a min No. 26 gage sheet steel, 1" min rigid nonmetallic Follow manufac :urer's installation for duct. Class 0 or Class 1 duct board, or other approved material and shall have no openings into the garage. As per FBC 2007 R309.1.1 MECHANICAL SCHEDULE MECHANICAL SCHEDULE EQUP. MANUFACTURER/ DESCRIPTION LOCATION NOTES: # MODEL NUM 3ER CDU MITSUBISHI OR APPROVED MINI SPLIT SYSTEM EXTERIOR 16 SEER #1 EQUAL 1 � 3-TON - - AHU MITSUBISHI O APPR JED MINI SPLIT SYSTEM .. BATHHOUSE a 16 SEER #1 EQUAL - - - AHU MITSUBISHI O APPR ✓ED MINI SPLIT SYSTEM STORAGE 16 SEER #2 EQUAL - - - EXH GREENHECK OR EQUA EXHAUST FAN BATH 30 CFM MECHANICAL SCHEDULE GENERAL NOTES; 1. Mini Split HVAC systems shal be Mitsubishi or approved equal W/ (1) Condensing Unit and (2) AHU's. 2. Refer to energy calculations or selection of HVAC equipment. CLG HEIGHT- 8i 8" SECOND FLOOR MECHANICAL FLAN i HESE PLANS AND ALL PROPOSED WUv(�� ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THX MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. N SCALE: 1/4" = 1'-0" _0 ra ra r �U+ v L afl-O�� c� �aE-o3aai,� .�C V1� 1.+U I�/1 E•mo-oEua;c C 'L C U T S to u rn �Luoc_�,�-3 a.J, •1— cL�Ena; m�vo°c=U c�Z� aNQ L.L 3u�a»uLy ® ;pCOL cnC3C '' O UaY Q Z 3 a=o00 4fu 1713 1 E rU rL; 1713 0 M2n 1 2 V ®u H O N Mechanical Plans Al GROUND FLOOR LIGHTING PLAN LIGHTING SCHEDULE TYPE MANUFACTURER/ DESCRIPTION LAMP VOLTS NOTES: OR EQUAL MANUFACTURER MODEL NUMBER A AS SELECTED 6" RECESSED COMPACT FLUORESCENT 120 RECESSED IN CEILING BY OWNER LIGHT FIXTURE B AS SELECTED 6" RECESSED COMPACT FLUORESCENT 120 RECESSED IN CEILING BY OWNER LIGHT FIXTURE - DAMP LOCATION C AS SELECTED WALL MOUNTED DECORATIVE LIGHT 120 MOUNT @ 80" A.F.F. TO BOTTOM OF BY OWNER FIXTURE-FEILD VERIFY D AS SELECTED WALL MOUNTED EXTERIOR DECORATIVE 120 MOUNT @ 80" A.F.F. TO THE CENTERLINE BY OWNER HID - DAMP LOCATION OF LIGHT'S JUNCTION BOX E AS SELECTED UNDER CABINET LIGHTING 120 VERIFY MOUNTING WITH BY OWNER OVERHEAD CABINETS LIGHTING SCHEDULE GENERAL NOTES: 1. All light fixtures shall be selected by Owner and installed by GC. 2. Install light fixtures as per manufacturer specifications. 3. Provide new bulbs for all new installed light fixtures. 4. Fixture finishes shall be selected by Owner. 5. Coordinate final location of fixtures with Owner prior to installation. -�NN SCALE: 1/4" = V-0" A w A GENERAL NOTES: LIGHTING 1. Contractor shall compare the electrical drawings 4. All electrical work and materials to be installed and specifi ations with drawings from other trades. per NEC, NFPA, local, state, and national code. Contractor ;hall report any discrepancies to the 5. Location of electrical raceways, switches, panels, Architect. obtain written instructions for any equipment, fixtures, etc. shall be adjusted to necessary hanges. accommodate the work to avoid interferences 2. Furnish an install fixtures as called for on the plans anticipated and encountered. or as selected by Owner. 6. Coordinate heights of wall mounted lighting fixtures 3. Contractor shall verify fixture type and locations to clear mirrors, cabinets, builts-ins, trim, etc. with owner prior to installation. ELECTRICAL LIGHTING LEGEND Switch Single Pole Ceiling Fan - to be selected by Owner Switch with Dimmer way Switch ANIINIONXX Wall Mounted Interior Decorative Light J J inction Box- See KEYED NOTES Xx i Wall Mounted Exterior Decorative Light XX nder Cabinet Lighting Wall Mounted Floor Light Q X Recessed xx Lights ❑■ Exhaust Fan Note: Subscribes are used to designate light types. See LIGHTING SCHEDULE for light types. A SECOND FLOOR LIGHTING PI -AN FA A M A M 0 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. N SCALE: 1/4" = V-0" � ro a a 0 o , ,EEN c cN�CtU U i 0 o C -?�Q O. ro a „ u Eo5a o-o�Uc)C C.CCO?��v 20 ��Uoc�,a3 3� c�wou t -o O-Ey'41 OL U C U E:3cw_°; Now L G�� co 0 0 C� C U C: Cc. u=Q a ut ® �U—�U ' 3: ;p C O-C " C :3�oU >'o Qs0ao3o� V � O L- �� F---1 O N M CT N M M N 00 O r, 00 00 4-J ON NN U to N N Q U L _ T N (T ru M 0 ram., (a \ o -a -a V) Ln U ®�M I- Z W O - ® E u1 N E M -, 1 - N Z$ 4-J UQ U Z ,-i (n (n C== u c LI 42I v U 2 0 W U TO M 0 e ® U ,v J 0 l� Q �- M 4-J M (� U z ui n E N 4— � - to Q 1 ru Ln in o- av✓ 0 Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet E2n 1 Lighting Plans LOAD CALCULATIOND New 100 amp SUB PANEL Load Calculations: Total Panel Load: 840 sgft. @ 3.0 VA/sgft. = 2,520 VA A/C #1 @ 2.5 kw = 2,500 VA Garbage Disposal = 900 VA 1st 10,000 VA @ 100% = 10,000 VA Refrigerator = 1,200 VA Remaining VA @ 400/0 = 1,848 VA Microwave = 1,500 VA Total: = 14,348 VA Dishwasher = 1,500 VA Dryer = 5,000 VA Washer = 1,200 VA Water Heater = 800 VA 14,348 VA - 59.78 amps A/C #1 @ 2.5 kw = 2,500 VA 240 V Sub -Total: = 17,120 VA Total Amps required: = 59.78 VA Summary: 1. Provide new 100 amp, 30 curcuit sub -panel at bathhouse. RISER DIAGRAM 0 EXISTIN(, M ETER (3) #TS (1 #8 GRND D/C �/C 200 200 SUB PANEL PANEL PANEL (EXIST.) (EXIST.) 100 AMP SCALE: N.T.S. �2 An XX" �::]QXXX XX" �::QG FI W. X0AFI -:::Qw P W. 7::nXXX W. �_YDED ELECTRICAL POWER LEGEND Duplex outlet Duplex outlet (Ground Fault Interrupt) Duplex outlet (Arc Fault Interrupt) Duplex outlet (Waterproof) Duplex split wired outlet Dedicated Duplex outlet Telephone outlet Data Port T.V. cable outlet WIRE SIZING TABLE BRK 0 N GND C 20 12 12 12 3/4" 30 10 10 10 3/4" 50 8 8 10 1" 70 4 4 8 1 1/4" 90 3 3 8 1 1/2" 100 3 3 8 11/2" 125 1 1 6 2" 150 1/0 1/0 6 2" 175 2/0 210 6 2" 200 3/0 3/0 6 21/2" 225 4/0 4/0 4 21/2" 250 250 250 4 3" 300 350 350 3 4" 350 500 500 3 4" n N SCALE: 1/4" = 1' -0" Dedicatec Duplex outlet (Ground Fault Interrupt) Dedicated Duplex outlet (Waterproof) Floor Duplex outlet Quadraplex outlet Quadraplex outlet (Ground Fault Interrupt) Quadraplex outlet (Waterproof) D/ Disconnect SD Smoke Detector (mount on ceiling, unless noted otherwise) Carbon Monoxide Detector (mount to wall, unless noted otherwise) �—Mounting height to the center line of the receptacle XX' ::QXXX Type of receptacle A 18" 18" GENERAL NOTES: POWER 1. Contractor shall c bmpare the electrical drawings and specificationE with drawings from other trades. Contractor shall report any discrepancies to the Architect. Obtain written instructions for any necessary changes. 2. Contractor to verify and coordinate utility service with local utility company. Locate meter and panel as required. 3. Install temporary power for construction as required. 4. All electrical work and materials to be installed per NEC, NFPA, local, state, and national code. 5. Location of electrical raceways, switches, panels, equipment, fixtures, etc. shall be adjusted to accommodate the work to avoid interferences anticipated and encountered. 6. Contractor shall verify switch type and locations with owner prior pao installation. Color of cover plates, switches find receptacles shall be selected by owner. 7. Contractor shall cetermine the exact route and location of each electrical raceway prior to make-up and assembly. 8. Outlets and appliances are shown and located on the drawings as accurately as possible. All measurements shall be verified on the project and in all cases the work shall suit the surrounding trim, finishes, and/'or construction. 9. Heights of all out ets shown on the drawings are approximate onl . 10. All outlets install ]d outdoors, bathrooms, and garage shall have ground -fault interrupter circuit breaker or recep acle. All outlets installed in the bedrooms shall have arc -fault interrupter receptacles. STORAGE 105 SECOND FLOOR POWER PLAN m M 1111 M 18" F/GFI LCONY 106 11. Load data and calculations were designed based on information given to Architect at the time of the design. Prior to installation of all equipment verify size of equipment and panel sizes. 12. Electrical system shall be grounded. See Riser Diagram. 13. Outlet boxes shall be pressed steel in dry locations, cast alloy with threaded hubs in wet and damp locations and special enclosures for other classified locations. 14. Disconnect switches shall be H.P. rated, heavy duty, quick -made, quick break enclosure required by exposure. 15. Smoke detectors shall be hard wired (110 volt type) to non-switchable light circuit and shall not be connected into the load side of a ground fault circuit. 16. Smoke detectors shall be located on or near ceiling inside and outside each sleeping area. Verify locations of smoke detectors with the drawings. 17. Smoke detectors shall be 110 volt type, with a test button with battery back-up system and visible "power on'' indicator. 18. All 12-volt, single phase, 15 and 20 amp branch circuits supplying outlets installed in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, rec rooms, closets, hallways, similar rooms or areas shall be protected by a listed arc -fault circuit interrupter combination type, installed to provide protection of the branch circuit (NEC 2008 210.12 (B)). 19. Tamper Resistant Receptacles (NEC 406.11) are required in dwelling units in all areas as specified in 2008 NEC 210.52, all 125 volt, 15 and 20 amp receptacles. .aa °LAl6 AND ALL PI�UI'obED W0ki< tl RE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSAY L APPLo ABLE CODER TO DES, COMPLY WITH AL N SCALE: 1/4" = 1'-0" ro _ EvL +�e v O•u C L C o ro �5 EE uu L�v°c,�a3 •`�y E ./ _ gv, '00CCu e CL(D C)0" o,e�, O•��� Qao L (C u E � T) O C 1 .0 P-4 o N N M C) r�l co M 00 0 111 pp 00 4-J O N N N < � r, i L _ Q rB c � � (n o� Ul)C�u O O -p �_ 4-Jc �- cn V O ''' M Z W C% LL f1 V/ O E L_ 1_ -� (1) E -:�; M ' D O •- N � 4-JU U Z ,-� U*) (n a C a� U ew �! u a C: L l(S � ° L u U o� o � �rn �rn (,n L :-a O 4-J un C-LL0) Q �M (� n E (V Ln n Rev. # Date 1 06-Dec-11 Bldg Dept Comments 2 12-Jan-12 Field Revisions Proj 11-0470 No. Status Final Issue 14-Sep-11 Date Sheet E 3 Power Plans