FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: INDIAN RIVER ESTATES LOT 9
Builder Name: COPPER ENTERPRISES
Street: 5002 HICKORY DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: INDIAN RIVER ESTATES LOT 9
Jurisdiction:
O-Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1548.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=9.0 1353.00 ft2
b. Frame - Wood, Adjacent
R=13.0 195.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1666.0 sqft.)
Insulation Area
a. Cathedral/Single Assembly (Unvented) R=30.0 1666.00 ft2
6. Conditioned floor area above grade (ft2) 1666
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(221.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 333
a. U-Factor: Dbl, U=0.32 120.00 ft2
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.69 60.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
35.4 SEER:17.00
c. U-Factor: Dbl, U=0.32 28.00 ft2
SHGC: SHGC=0.22
13. Heating systems'
kBtu/hr Efficiency
d. U-Factor: other (see details) 13.83 ft2
a. Electric Heat Pump
35.4 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 5.110 ft.
Area Weighted Average SHGC: 0.204
14. Hot water systems
8. Floor Types (1666.0 sqft.) Insulation Area
a. Electric
Cap: 80 gallonsEF:0.920
a. Slab -On -Grade Edge Insulation R=0.0 1666.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.133 Total Proposed Modified Loads: 54.14
PASS
Total Baseline Loads: 56.36
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
�+ _ g
Code.
calculation indicates compliance
with the Florida Energy Code.
tr rnr� . 1�% •;;::°• .•;,.����
PREPARED Y:
DATE: -t
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a
I hereby certify that this build' s de ' ed, is in compliance
Florida Statutes.
5�
with the Florida Energy Code.
G'Op wit
OWNER/AGENT:-
BUILDING OFFICIAL:
DATE: & J`L 1?
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R40F 1 nd n 'eakage
PJ
test report in accordance with R402.4.1.2.
✓
8/9/2017 11:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
. Builder Name:
Permit Office:
Jurisdiction:
• Family Type:
New/Existing:
Comment:
INDIAN RIVER ESTATES LO
User
INDIAN RIVER ESTATES LO
1
COPPER ENTERPRISES
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 1666
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
5002 HICKORY DRIVE
ST. LUCIE COUNTY
FT. PIERCE,
FL,
CLIMATE
v Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90
70
75 299
62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 1666
14994
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main 1666
14994 Yes 1
3
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 175 ft 0
1666 ftZ
----
1 0 0
ROOF
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or shed Composition shingles 1805 ftz 346 ftZ Medium
0.6
No 0.9
No 30 22.6
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Unvented 0 1666 ftz
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Cathedral/Single Assembly (Unvented Main 30 Blown
1666 ft2 0.11
Wood
8/9/2017 11:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar
Below
#
Ornt
In
Wall T4pe
R_Va11e Ft
n
Et n
ArenR-Ntalfe
1
NE
Exterior
Concrete Block - Int Insul
Main
9 52
9
468.0 ft2
0
0.6
0
_ 2
SE
Exterior
Concrete Block - Int Insul
Main
9 37
8
9
339.0 ft2
0
0.6
0
= 3
SW
Exterior
Concrete Block - Int Insul
Main
9 30
6
9
274.5 ft2
0
0.6
0
_ 4
NW
Exterior
Concrete Block - Int Insul
Main
9 30
2
9
271.5 ft2
0
0.6
0
o- 5
NW
Garage
Frame - Wood
Main
13 21
8
9
195.0 ft2
0.23
0.6
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
NE
Insulated
Main
None
.28
3
6 8
28 ft2
Wall
V/ #
Ornt
ID
Frame
Panes
1
NE
1
Vinyl
Low-E Doub
2
NE
1
Vinyl
Low-E Doub
3
NE
1
Vinyl
Low-E Doub
4
NE
1
Vinyl
Low-E Doub
5
NE
1
Vinyl
Low-E Doub
6
SE
2
Vinyl
Low-E Doub
7
SE
2
Vinyl
Low-E Doub
8
SE
2
Vinyl
Low-E Doub
9
SW
3
Vinyl
Low-E Doub
10
SW
3
Vinyl
Low-E Doub
11
SW
3
Vinyl
Low-E Doub
12
NW
4
Vinyl
Low-E Doub
13
NW
4
Vinyl
Low-E Doub
# Floor Area
1 462 ft2
# Scope Method
1 Wholehouse Proposed ACH(50)
WINDOWS
Orientation shown is the entered, Propos
NFRC
U-Factor SHGC
le
Yes
0.32 0.19
le
Yes
0.32 0.19
le
Yes
0.32 0.22
le
Yes
0.69 0.22
le
Yes
0.32 0.19
le
Yes
0.32 0.19
le
Yes
0.32 0.19
le
Yes
0.32 0.21
le
Yes
0.32 0.19
le
Yes
0.32 0.19
le
Yes
0.32 0.19
le
Yes
0.32 0.22
le
Yes
0.28 0.23
GARAGE
:fling Area
Exposed Wall Perimeter
462 ft2
21 ft
INFILTRATION
Overhang
Area
Depth
Separation
Int Shade
Screeni
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
12.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
60.0 ft2
12 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
4.5 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
None
15.0 ft2
5 ft 0 in
1 ft 4 in
Drapes/blinds
None
16.0 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
9.3 ft2
2 ft 0 in
1 ft 4 in
Drapes/blinds
None
Wall Height Exposed Wall Insulation
9ft 13
SLA CFM 50 ELA EgLA ACH ACH 50
.0004 1749.3 96.03 180.61 .2922 7
8/9/2017 11:53 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
None
HSPF:8.5
35.4 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
None
SEER: 17 35.4 kBtu/hr 1062 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.92 80 gal 60 gal
120 deg.
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector
Model
# Area
Volume
FEF
None None
ft2
DUCTS
V
-- Supply —
-- Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 333 ft2
Attic
83 ft2 Default Leakage
Garage
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
He H
Feb
Jan H Feb
Mar
Mar
HX
Apr
Apr I
Jul
May Jun Jul
May X Jun ri
AuSep
rl Aug
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin
Jan Feb
Mar
[X] Apr
May Jun Jul
Aug
Se
[X]
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
8/9/2017 11:53 AM - EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
- ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
'
5002 HICKORY DRIVE, FT. PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=9.0
1353.00 ft2
b. Frame - Wood, Adjacent R=13.0
195.00 ft2
3. Number of units, if multiple family
1 c. N/A R=
ft2
4. Number of Bedrooms
3 d. N/A R=
ft2
5. Is this a worst case?
No 10. Ceiling Types Insulation
Area
a. Cathedral/Single Assembly (Unvented) R=30.0
1666.00 ft2
6. Conditioned floor area (ft2)
1666 b. N/A R=
ft2
7. Windows- Description
Area c' _
ftz
a. U-Factor: Dbl, U=0.32
120.00 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 333
SHGC: SHGC=0.19
b. U-Factor: Dbl, U=0.69
60.00 ft2
SHGC: SHGC=0.22
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.32
28.00 ft2 a. Central Unit 35.4 SEER:17.00
SHGC: SHGC=0.22
d. U-Factor: other (see details)
13.83 ft2
SHGC: other (see details)
13. Heating systems kBtu/hr
Efficiency
a. Electric Heat Pump 35.4
HSPF:8.50
Area Weighted Average Overhang Depth:
5.110 ft.
Area Weighted Average SHGC:
0.204
8. Floor Types Insulation Area 14. Hot water systems
Cap:
80 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1666.00 ft2 a. Electric
EF: 0.92
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final i ction. Otherwise, a new EPL Display Card will be completed
based on installed Code mp a ur
Builder Signature: Date:
Address of New Home: SOaa i22rurf_-' City/FL Zip: IFbr, , aAecf F,-
3 44Sr�
WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or seethe EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/9/2017 11:54 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: INDIAN RIVER ESTATES LOT 9 Builder Name: COPPER ENTERPRISES
Street: 5002 HICKORY DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: INDIAN RIVER ESTATES LOT 9 Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
8/9/2017 11:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1