Loading...
HomeMy WebLinkAboutENRGY EFFICIENCY CODE10]VI►Hato] * r1i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: INDIAN RIVER ESTATES LOT 9 Builder Name: COPPER ENTERPRISES Street: 5002 HICKORY DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: INDIAN RIVER ESTATES LOT 9 Jurisdiction: O-Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1548.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 1353.00 ft2 b. Frame - Wood, Adjacent R=13.0 195.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1666.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=30.0 1666.00 ft2 6. Conditioned floor area above grade (ft2) 1666 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(221.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 333 a. U-Factor: Dbl, U=0.32 120.00 ft2 SHGC: SHGC=0.19 b. U-Factor: Dbl, U=0.69 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a. Central Unit 35.4 SEER:17.00 c. U-Factor: Dbl, U=0.32 28.00 ft2 SHGC: SHGC=0.22 13. Heating systems' kBtu/hr Efficiency d. U-Factor: other (see details) 13.83 ft2 a. Electric Heat Pump 35.4 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.110 ft. Area Weighted Average SHGC: 0.204 14. Hot water systems 8. Floor Types (1666.0 sqft.) Insulation Area a. Electric Cap: 80 gallonsEF:0.920 a. Slab -On -Grade Edge Insulation R=0.0 1666.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.133 Total Proposed Modified Loads: 54.14 PASS Total Baseline Loads: 56.36 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this �+ _ g Code. calculation indicates compliance with the Florida Energy Code. tr rnr� . 1�% •;;::°• .•;,.���� PREPARED Y: DATE: -t Before construction is completed this building will be inspected for compliance with Section 553.908 a I hereby certify that this build' s de ' ed, is in compliance Florida Statutes. 5� with the Florida Energy Code. G'Op wit OWNER/AGENT:- BUILDING OFFICIAL: DATE: & J`L 1? DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R40F 1 nd n 'eakage PJ test report in accordance with R402.4.1.2. ✓ 8/9/2017 11:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: . Builder Name: Permit Office: Jurisdiction: • Family Type: New/Existing: Comment: INDIAN RIVER ESTATES LO User INDIAN RIVER ESTATES LO 1 COPPER ENTERPRISES ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1666 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 5002 HICKORY DRIVE ST. LUCIE COUNTY FT. PIERCE, FL, CLIMATE v Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1666 14994 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1666 14994 Yes 1 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 175 ft 0 1666 ftZ ---- 1 0 0 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or shed Composition shingles 1805 ftz 346 ftZ Medium 0.6 No 0.9 No 30 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1666 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvented Main 30 Blown 1666 ft2 0.11 Wood 8/9/2017 11:53 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below # Ornt In Wall T4pe R_Va11e Ft n Et n ArenR-Ntalfe 1 NE Exterior Concrete Block - Int Insul Main 9 52 9 468.0 ft2 0 0.6 0 _ 2 SE Exterior Concrete Block - Int Insul Main 9 37 8 9 339.0 ft2 0 0.6 0 = 3 SW Exterior Concrete Block - Int Insul Main 9 30 6 9 274.5 ft2 0 0.6 0 _ 4 NW Exterior Concrete Block - Int Insul Main 9 30 2 9 271.5 ft2 0 0.6 0 o- 5 NW Garage Frame - Wood Main 13 21 8 9 195.0 ft2 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated Main None .28 3 6 8 28 ft2 Wall V/ # Ornt ID Frame Panes 1 NE 1 Vinyl Low-E Doub 2 NE 1 Vinyl Low-E Doub 3 NE 1 Vinyl Low-E Doub 4 NE 1 Vinyl Low-E Doub 5 NE 1 Vinyl Low-E Doub 6 SE 2 Vinyl Low-E Doub 7 SE 2 Vinyl Low-E Doub 8 SE 2 Vinyl Low-E Doub 9 SW 3 Vinyl Low-E Doub 10 SW 3 Vinyl Low-E Doub 11 SW 3 Vinyl Low-E Doub 12 NW 4 Vinyl Low-E Doub 13 NW 4 Vinyl Low-E Doub # Floor Area 1 462 ft2 # Scope Method 1 Wholehouse Proposed ACH(50) WINDOWS Orientation shown is the entered, Propos NFRC U-Factor SHGC le Yes 0.32 0.19 le Yes 0.32 0.19 le Yes 0.32 0.22 le Yes 0.69 0.22 le Yes 0.32 0.19 le Yes 0.32 0.19 le Yes 0.32 0.19 le Yes 0.32 0.21 le Yes 0.32 0.19 le Yes 0.32 0.19 le Yes 0.32 0.19 le Yes 0.32 0.22 le Yes 0.28 0.23 GARAGE :fling Area Exposed Wall Perimeter 462 ft2 21 ft INFILTRATION Overhang Area Depth Separation Int Shade Screeni 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 12.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 60.0 ft2 12 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 4.5 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds None 15.0 ft2 5 ft 0 in 1 ft 4 in Drapes/blinds None 16.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None 9.3 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds None Wall Height Exposed Wall Insulation 9ft 13 SLA CFM 50 ELA EgLA ACH ACH 50 .0004 1749.3 96.03 180.61 .2922 7 8/9/2017 11:53 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 35.4 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 17 35.4 kBtu/hr 1062 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 80 gal 60 gal 120 deg. None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V -- Supply — -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 333 ft2 Attic 83 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan He H Feb Jan H Feb Mar Mar HX Apr Apr I Jul May Jun Jul May X Jun ri AuSep rl Aug Se ri Oct Oct Nov Nov HX Dec Dec H Ventin Jan Feb Mar [X] Apr May Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/9/2017 11:53 AM - EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD - ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. ' 5002 HICKORY DRIVE, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=9.0 1353.00 ft2 b. Frame - Wood, Adjacent R=13.0 195.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Cathedral/Single Assembly (Unvented) R=30.0 1666.00 ft2 6. Conditioned floor area (ft2) 1666 b. N/A R= ft2 7. Windows- Description Area c' _ ftz a. U-Factor: Dbl, U=0.32 120.00 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 333 SHGC: SHGC=0.19 b. U-Factor: Dbl, U=0.69 60.00 ft2 SHGC: SHGC=0.22 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.32 28.00 ft2 a. Central Unit 35.4 SEER:17.00 SHGC: SHGC=0.22 d. U-Factor: other (see details) 13.83 ft2 SHGC: other (see details) 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 35.4 HSPF:8.50 Area Weighted Average Overhang Depth: 5.110 ft. Area Weighted Average SHGC: 0.204 8. Floor Types Insulation Area 14. Hot water systems Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 1666.00 ft2 a. Electric EF: 0.92 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final i ction. Otherwise, a new EPL Display Card will be completed based on installed Code mp a ur Builder Signature: Date: Address of New Home: SOaa i22rurf_-' City/FL Zip: IFbr, , aAecf F,- 3 44Sr� WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or seethe EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 8/9/2017 11:54 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: INDIAN RIVER ESTATES LOT 9 Builder Name: COPPER ENTERPRISES Street: 5002 HICKORY DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: INDIAN RIVER ESTATES LOT 9 Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 8/9/2017 11:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1