HomeMy WebLinkAboutREVIEW - COMMENTSPlanning &.Development Services
Building $ Code Regulatlon Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462 2172 Fax:(772)462-6"3
PROPERTY INFORMATION
Address: 5002 Hickory Dr.
City / State / Zip: Fort Pierce, FI 34982
Parcel #: 3402-608-0204-000/9
Zoning:
REVIEW COMMENTS
e1
Owner(s):
Cooper Enterprises 4.0 Llc
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 9
APPLICATION INFORMATION
Permit Number: 1706-0477 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Stewart P Cooper
Business Name: Cooper Enterprises 4.0 Llc
Business Addr: 2511 Sw Regency Rd
City / State / Zip: Stuart, FI 34997-1226
REVIEWS AND COMMENTS
Block: 46
Automatic Sprinkler System? No
Fax Number:
Email: Stewart@Cooperentllc.Con
struction
Review Type
Status Reviewed By Date Started Date Completed Date Released
ADDRESSING ASSIGNMENT
COMPLETE Lydia Galbraith 612812017 7/612017 7/6/2017
Comment:
DOCUMENTS MISSING
PENDING Lashahna Ingram
6/21/2017 Comment:
SUB AGREEMENTS FOR ELECTRICAL, MECHANICAL AND PLUMBING.
6/2812017 Comment:
COPY OF RECEIPT FOR PAID UTILITIES (WATER)
6/28/2017 Comment:
APPLICATION FOR DRIVEWAY PERMIT, CONNECTION TO THE ROAD.
6/29/2017 Comment:
VEG PERMIT IN DRAWER UNDER "C" COOPER ENTERPRISES
ENVIRONMENTAL REVIEW
COMPLETE Lynn Swartzel 6/28/2017 6/28/2017 6/28/2017
Comment:
FRONT COUNTER REVIEW
COMPLETE Lashahna Ingram 6/21/2017 6/21/2017 6/21/2017
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE Joe Cicio 7/20/2017
7/20/2017 Comment:
SHOW THE APPROVED APPLIANCE PROTECTION FOR GARAGE APPLIANCES PER FBCM 303.4 [
MECHANICAL DAMAGE]
PLANS EXAMINER REVIEW
PENDING William Durden 7/19/2017
7/20/2017 Comment:
• PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING
THE SQUARE FOOT INFORMATION. SEE CHAPTER 1 SECTION 107 OF THE 2014 FLORIDA BUILDING CODE.
Comment:
- PLEASE FURNISH THE MANUFACTURES'TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
7/20/2017
APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
Planning & Development Services
Building &'Code Regulation Division.
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
REVIEW COMMENTS
Page 2
7/20/2017 Comment:
• PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE .
7/20/2017 Comment:
• ENERGY CALC'S INFORMATION BLOCK AT THE TOP OF THE PAGE ARE INCOMEPLETE. SEE SECTION
405.4.2 (1) OF THE 2014 FLORIDA ENERGY CODE.
7/20/2017 Comment:
• INSULATION R-VALUES STATED ON THE ENERGY CALC'S DO NOT MATCH THE SUBMITTED DRAWINGS
FOR REVIEW. SEE CHAPTER 4 SECTION 402 SUBSECTION 402.1.2 OF THE 2014 FLORIDA ENERGY CODE.
Comment:
MULTIPLE TYPES OF WINDOWS SHOWN ON THE PLANS, ENERGY CALC ONLY LISTS ONE U FACTOR AND
SOLAR HEAT GAIN FOR MULTIPLE TYPES OF WINDOWS.
7/20/2017
• PLEASE SUBMIT THE ENERGY PERFOMANCE SHEETS OR SUBMIT A THE NFRC FENSTRATION
MANUFACTURE CERTIFICATE FOR THE U-FACTOR AND THE SHGC FOR EACH GLAZED OPENING SHOWING
COMPLIANCE WITH CHAPTER 4 SECTION 402.1.1 OF THE 2014 ENERGY CODE FIFTH EDITION.
Comment:
• PLEASE SHOW ON THE SOIL DENSITY ON THE PLANS OR SUBMIT A GEOTECHNICAL REPORT WITH
7/20/2017
RECOMMENDATIONS FOR THE NEW FILL REQUIREMENTS. SEE CHAPTER 4 SECTION R401 OF THE 2014
FLORIDA RESIDENTIAL CODE.
Comment:
COULD NOT COMPLETE REVIEW OF TRUSS CONNECTOR SCHEDULE. NO TRUSS ENGINEERING WERE
7/20/2017
SUBMITTED WITH PLANS. ADDITIONAL REVIEW WILL BE NEEDED ONCE TRUSS ENGINEERING HAS BEEN
SUBMITTED. SEE SECTION 107 OF THE 2014 FLORIDA BUILDING CODE.
Comment:
• PLEASE FURNISH THE COMPRESSIVE STRENGHT OF THE'CONCRETE BEING USED FOR THE FLOOR,
7/20/2017
FOUNDATION, COLUMNS AND BEAMS BEING IN ACCORDANCE WITH 402.2 OF THE 2014 FLORIDA
BUILDING CODE
7/20/2017 Comment:
• PLEASE FURNISH A INTERIOR WALL DETAIL SHOWING STUD SPACING, STUD SIZE, AND WALL FINISH IN
ACCORDANCE WITH 602.2 OF THE 2014 FLORIDA BUILDING CODE
Comment:
• PLEASE SHOW ON THE PLANS THE R-VALUE FOR THE GARAGE TO HOUSE WALL SEPARATION, FROM
7/20/2017
CONDITIONED SPACE TO NON -CONDITIONED SPACE. SEE CHAPTER 4 SECTION R-402 SUBSECTION R-
402.2.13 OF THE 2014 FLORIDA ENERGY CODE.
7/20/2017 Comment:
• PLEASE SHOW THE GARAGE TO HOUSE SEPERATION BEING IN ACCORDANCE WITH 302.6 OF THE
FLORIDA RESIDENTIAL CODE
7/20/2017 Comment:
• PLEASE SHOW FLAME SPREAD INDEX AND SMOKE DEVELOPED INDEX FOR WALL AND CEILING FINISHES
IN ACCORDANCE WITH SECTION 302.9 OF THE 2014 FLORIDA RESIDENTIAL CODE
7/20/2017 Comment:
• PLEASE SHOW THE FLAME SPREAD AND SMOKE DEVELOPED INDEX FOR THE INSULATION AS
REQUIRED IN SECTION 302.10 OF THE 2014 FLORIDA RESIDENTIAL CODE
7/20/2017 Comment:
• PLEASE SHOW GYPSUM BOARD MATERIALS ARE IN ACCORDANCE WITH 702.3.1 OF THE 2014 FLORIDA
RESIDENTIAL CODE
7/20/2017 Comment:
PAGE EV-2 SHOWS FIXED WINDOW F NO FIXED WINDOW SHOWN ON THE PRODUCT REVIEW AFFIDAVIT.
SEE SECTION 107'OF THE 2014 FLORIDA BUILDING CODE.
Comment: • PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
7/20/2017 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
DOCUMENTS.
ZONING REVIEW COMPLETE Lydia Galbraith 6/2812017 7/19/2017 7/19/2017
Comment:
Planning $,;Development Services
Building & Code Regulation Division,
2306 Virginia Avenue
Fort Pierce, FL. 349.82
Phone:(772)462 2172 Fax:(772)462.6443
REVIEW COMMENTS
Page 2
REVISIONS COMPLETE William Durden 6/13/2018 6/1312018 6/13/2018
Comment:
REVISIONS INCOMPLETE William Durden 6/19/2018
6/19/2018 Comment: PLEASE SUBMIT REVISED ENERGY CALC'S IN DUPLICATE TO REFLECT THE CHANGE FROM SHINGLE
ROOF TO METAL ROOF. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
ZONING REVIEW COMPLETE Lydia Galbraith 6/28/2017 7/19/2017 7/19/2017
Comment: