HomeMy WebLinkAboutREVISION 6-13-18OFFICE USE ONLY:
1
DATE FILED:
REVISION FEE:
PERMIT # 1-7D b
RECEIPT #
PLANNING & DEVELOPMENT SERVICK...�..
BUILDING & CODE REGULATION DIVISIO
2300 VIRGINIA AVENUE E 1Yq
FORT PIERCE FL 34982-565''
,..
(772) 462.1553
JUdV
4 APPLICATION FOR BUILDING PIEROM
PrertrtltEln Af;•. ,�;
St, Lace epa�eht PROJECT INFORMATION F:L
y r y
County � �� � � aj •4
LOCATION/SITE 4'
ADDRESS:'
N. r
DETAILED DESCRIPTION OF PROJECT
REVISIONS: A
�G
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
-
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME:
ST. LUCIE CO CERT. #:
ZIP:
FAX:
STATE: ZIP:
FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117
STATE:
File - Copy.
Thomas E. Audit, PE
Florida Professional Engineer
P O Box 562
License No. 31419
ACachua, FC 32616-0562
(352) 214-7300 tomauditCa--windstream.net
March 21, 2018
Re.: Thomas E. Audit, PE- Structural Engineer of Record for:
Cooper - Indian River Estates, Lot 9
5002 Hickory Drive
Ft. Pierce, Florida 34982
Parcel: 3402-608-0204-000-9
Permit No.: 1706-0477
Contractor:
Cooper Enterprises 4.0, LLC
2511 SW Regency Rd.
Stuart, FI. 34997
Attn.: Stewart Cooper
772-600-5300
To: St. Lucie County Building Department
2300 Virginia Ave
Ft. Pierce, FL 34982
Building Official,
Page 1 of 1
7D(- -41�77
•ST, LVCIE COUNTY ELTILDLV O DjVMjb, #
REVIEWED FOR C
)tEdtE�►`E By
DATE
NB PERMIT MUST BE KEPT ON JOB
Q� �``� ECTION WILL BE MADE,
Stucco 9" Lapped Siding Change Engineering Approval
The Permit Plans call for Stucco Texture Finish 9" Lapped Siding. Hardy Board Plank Siding as
installed per the Manufacture's Instructions is an Approved Alternate.
Should you need any further information or have questions, please feel free to contact me.
Best regards,
PLANS AWO ALL PROPOSED N'U
RECTIONS
Usjv- TO ,INSPECTORS THV
{RED
.;EN C �,; -,y IN ORDER TO
LL APPLICABLE CODC-�•
Thomas E. Audit, PE
License No. PE 314,19
March 21, 2018
66hi6I .MA FASTENERS OR ATMACHdJ UIT4
A11E TIIF I'FSPONSIBIIITY OF THE
COitirwCTOA OP RECORD
File, COPY,
6/13/2018 , Florida Building Code Online
I fit
Professional Regulation r �
f
BCIS Home I Log In I User Registration I Hot Topics I Submit surcharge I Stabs & Facts I Publications I FBC Staff I BCIS Site Map I links Search I
b
a .
r ""r Product Approval
IUSER: Public User
t c^re iur
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL13223-113
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
James Hardie Building Products, Inc.
26300 La Alameda
Ste. 250
Mission Viejo, CA 92691
(909) 349-2927
pingsheng.zhu@jameshardie.com
Pingsheng Zhu
pingsheng.zhu@jameshardle.com
Pingsheng Zhu
10901 Elm Ave.
Fontana, CA 92337
(909) 349-2927
pingsheng.zhu@jameshardie.com
Pingsheng Zhu
10901 Elm Ave.
Fontana, CA 92337
(909) 349-2927
pingsheng.zhu@jameshardie.com
Panel Walls
Siding
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
,W5 Evaluation Report - Hardcopy Received
Ronald I. Cgawa
PE-24121
Intertek Testing f
O1/01/2018
John Southard, P.
d, Validation Chi
Standard
ASTM C1186
ASTM E330
Year
File C®Poz
Florida Licensed Professional Engineer or Architect
FL13223 R3 Equiv ASTM C1186 Equivalency---5�igne .p�f
https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66FCwkdpAghfYHGjGlt%2bDQvvyGr3xeyyxDBQ%3d%3d 1/3
6/13/2018
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
08/17/2015
08/26/2015
09/07/2015
10/16/2015
08/09/2017
FL #
Model, Number or Name
Description
13223.1
Cempanel Siding
fiber -cement panel siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: For use inside a HVHZ install in accordance with NOA
Installation Instructions
FL13223 R3 II ER RIO-2556-15 Panel metal-wood.pdf
FL13223 R3 II ER RIO-2578-15 Panel to Furring,pdf
FL13723 R3 II Install Cempanel Siding -a f
FL13223 R3 II NOA 15-0122.04 p�f
Verified By: Intertek Testing Services NA Ltd.
15-0122.04
Created by Independent Third Party: No
Evaluation Reports
FL13223 R3 AE ER RIO-2556-15 Panel metal -wood pdf
FL13223 R3 AE ER RIO-2578-15 Panel to Furring,pdf
FL13223 R3 AE NOA 15-0122 04 Ddf
Created by Independent Third Party: Yes
13223.2
HardiePanel Siding
fiber -cement panel siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: For use inside a HVHZ install in accordance with NOA
Installation Instructions
FL13223 R3 II ER RIO-2556-15 Panel metal-wood.pdf
FL13223 R3 II ER RIO-2578-15 Panel to Furring,pdf
FL13223 R3 II Install HardiePanel Siding,pdf
FL13223 R3 II NOA 15-0122.04.pdf
Verified By: Intertek Testing Services NA Ltd.
15-0122.04.
Created by Independent Third Party: No
Evaluation Reports
FL13223 R3 AF ER RIO-2556-15 Panel metal -wood pdf
FL13223 3223 R3 AE ER RIO-2578-15 Panel to Furring,pg f
FL13223 R3 AE NOA 15-0122 04 odf
Created by Independent Third Party: Yes
13223.3
Prevail Panel Siding
fiber -cement panel siding
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: For use inside a HVHZ install in accordance with NOA
Installation Instructions
FL13223 R3 II ER RIO-2556-15 Panel metal -wood pdf
FL13223 R3 II ER RIO-2578-15 Panel to Furring,pdf
FL13223 R3 II Install Prevail Panel Siding,pdf
FL13223 R3 II NOA 15-0122 04 pdf
Verified By: Intertek Testing Services NA Ltd.
15-0122.04.
Created by Independent Third Party: No
Evaluation Reports
FL13223 R3 AE ER RIO-2556-15 Panel metal-wood.pdf
FL13223 R3 AE ER RIO-2578-15 Panel to Furring,of
FL13223 R3 AE NOA 15-0122.04.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. QQyrjght 2007-2013 State of Florida.:: privacy Statement :: Accesslbllity Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
IMMM®® fct_
https://www.floridabuilding.org/prlpr app_dU.aspx?param=wGEVXQwtDgvRk6bsvZ66FCwkdpAghfYHGjGlt%2bDQvVYGr3xeYYxD8Q%3d%3d 2/3
PROJECT RIO-2556-15
ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE® BRAND
FIBER -CEMENT PANELS TO WOOD AND METAL FRAMED WALLS WITH VARIOUS FASTENERS
JAMES HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
TABLE OF CONTENTS
PAGE
COVER PAGE
1
EVALUATION SUBJECT
2
EVALUATION SCOPE
2
EVALUATION PURPOSE
2
REFERENCE REPORTS
2
TEST RESULTS
3
TABLE 1A, RESULTS OF TRANSVERSE LOAD TESTING
3
TABLE 1 B, SHEAR VALUES
3
DESIGN WIND LOAD PROCEDURES
4
TABLE 2, COEFFICIENTS AND CONSTANTS USED IN DETERMINING V AND p
4
TABLE 3, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B
5
TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C
5
TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D
5
TABLE 6, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPANEL SIDING
6-7
LIMITATIONS OF USE
7
AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN
COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7-10, THE 2014 FLORIDA BUILDING CODE, AND
THE 2012 INTERNATIONAL BUILDING CODE.
PREPARED BY:
RONALD I. OGAWA & ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
EVALUATION SUBJECT
HardiePanel@ Siding
James Hardie Product Trade Names covered In this evaluation:
HardiePaneIG Siding, CempanelS Siding, Prevail- Panel Siding
EVALUATION SCOPE:
ASCE 7-10
2014 Florida Building Code
2012 International Building Code®
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2556-15
EVALUATION PURPOSE:
This analysis Is to determine the maximum design 3-second gust wind speed to be resisted by an assembly of HardiePanel (Cempanel, Prevail Panel) siding fastened to wood or metal framing
with nails or screws.
REFERENCE REPORTS:
1. Intertek Report 3067913 (ASTM C1186) Material properties HardiePanel Siding
2. Ramtech Laboratories Report IC-1270-94 (ASTM E330) Transverse Load Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches
on center with a 6d common galvanized nail
3. Ramtech Laboratories Report ICA271-94 (ASTM E330) Transverse Load Test, 5116' Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches
on centerwilh•a 6d common galvanized nail
4. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E330) Transverse Load Test, 5116" Thick by 48 Inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 wood studs
spaced at 16 inches on center with a 4d, 0.091 Inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail
S. Ramtech Laboratories, Report IC-1054-89 (ASTM E330) Transverse Load Test,1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 16 inches on
center with a No 8 X 1 In. long X 0.323 in head diameter ribbed bugle head screw
6. Ramtech Laboratories, Report ICA055-89 (ASTM E330) Transverse Load Test, 1/4" Thick by 48 inch wide HardiePanel Siding installed on 20gauge Metal studs spaced at 24 inches on
center with a No 8 X 1 in. long X 0.323 in head diameter ribbed bugle head screw
7. Ramtech Laboratories, Report 11149-98/1554d (ASTM E330) Transverse Load Test,114" Thick by 48 inch wide HardlePanel Siding installed on 20gauge Metal studs spaced at 16 and 24
inches on center with a ET&F 0.100 in. knurled shank X 1.5 in, long X 0.25 in. head diameter pin fastener
8. Ramtech Laboratories Report IC-1273-94 (ASTM E72) Racking Shear Test, 5116' Thick by 46 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 inches on
center with a 6d common galvanized nail
9. Ramtech Laboratories Report IC-1274-94 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 24 inches on
center with a 6d common galvanized nail
10. Ramtech Laboratories, Inc. Report 10868-9711475 (ASTM E72) Racking Shear Test, 5116" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Group III SG=0.36 wood studs
spaced at 16 inches on center with a 4d, 0.091 inch shank by 0.225 inch head diameter by 1.5 inch long ring shank nail
11. Ramtech Laboratories Report IC-1057-89 (ASTM E72) Racking Shear Test, 5/16" Thick by 48 inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 and 24
inches on center with a No 8 X 1 in. long X 0.323 in head diameter ribbed bugle head screw
12. Ramtech Laboratories Report 11284-99/1580 (ASTM E72) Racking Shear Test, 5116" Thick by 48 Inch wide HardiePanel Siding installed on 2X4 Hem -Fir wood studs spaced at 16 and 24
inches on center with a ET&F 0.100 in, knurled shank X 1.5 in. long X 0.25 in. head diameter pin fastener
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
TEST RESULTS:
Table 1a, Results of Transverse Load Testing
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #1443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2556-15
Fastener Spacing
n t
Allowable
Frame
Ultimate
Design
Thickness
Width
Spacing
Perimeter
Field
Load
Load'
Report Number
Test Agency
(in.)
(in.)
Frame Type
(in.)
Supports
Supports
Fastener Type
(PSF)
(PSF
IC-1270-94
Ramtech
0.3125
48
2X4 wood Hem -Fir
16
6
6
6d common
-149
-49.7
IC-1270.94
Ramtech
0.3125
48
2X4 wood Hem -Fir
16
4
4
6d common
-236
-78.7
IC-1271-94
Ramtech
0.3125
48
2X4 wood Hem -Fir
24
6
6
6d common
-94
-31.3
IC-1271-94
Ramtech
1 0.3125
48
1 2X4 wood Hem -Fr
24
4
4
1 6d common
-143
-47.7
10868-97/1475
Ramtech
0.3125
48
2X4 wood, SG z 0.36
16
4
8
4d, 0.091 in. shank X 0.225 in.
HD X 1.5 in. long ring shank nail
90
-30.0
Min. No 8 X 1 in. long X 0.323 in
IC-1054.89
Ramtech
0.25
48
Min. No. 20 gauge X 3.625 in. X
16
6
6
head diameter ribbed bugle
-169.9
-56.6
1.375 in metal stud
head screw
Min. No 8 X 1 in. long X 0.323 In
IC-1055-89
Ramtech
0.25
46
Min. No. 20 gauge X 3.625 in. X
24
6
6
tread diameter ribbed bugle
-91.9
-30.6
1.375 in metal stud
head screw
ET&F 0.100 in. knurled shank X
11149-98/1554d
Ramtech
0.3125
48
Min. No. 20 gauge X 3.625 in. X
24
4
8
1.5 long Xn in. head
170
56.7
1.375 in metal s tud
fa
diameter pin fastener
is
ET&F 0.100 in. knured shank X
11149-98/1554d
Ramtech
0.3125
48
Min. No. 20 gauge X 3.625 in. X
16
4
8
1.5 in. long X 0.in. head
101
�3.7
1.375 in metal stud
diameter pin fastener
1. Allowable Load is the Ultimate Load divided by a t-actor or sarery or s.
2. HardiePanel Siding complies with ASTM C1186, Standard Specification for Grade 11, Type A Non -asbestos Fiber -Cement Flat Sheets.
Table 1 b, Shear Values Allowable Loads in Pounds Per Lineal Foot for Panel Shear Walls 1.2
Fastener Spacing
n„ �
Frame
Ultimate
Allowable
Thickness
Width
Spacing
Perimeter
Field
Load3
Load3
Report Number
Test Agency
(in.)
(in.)
Frame T e
(in.)
Supports
Supports
Fastener Type
(pit)
( I
IC-1273-94
Ramtech
0.3125
48
2X4 wood Hem -Fir
16
6
6
6d common
603.8
201.3
IC-1273.94
Ramtech
0.3125
48
2X4 wood Hem -Fir
16
4
4
6d common
698.8
232.9
IC-1274-94
Ramtech
0.3125
48
2X4 wood Hem -Fr
24
6
6
6d common
460.0
153.3
IC-1274-94
Ramtech
0.3125
48
2X4 wood Hem -Fr
24
4
4
6d common
637.5
212.5
4d, 0.091 in. shank X
0.10868-97/1475
Ramtech
0.3125
48
2X4 wood, SG a 0.36
16
4
8
ank nail
HD X 1.5 in. long ring shh nk
595.4
198.5
Min. No 8 X 1 in. long X 0.323 in
IC-1057-89
Ramtech
0.25
48
Min. No. 20 gauge X 3.625 in. X
16 & 24
1 6
6
tread diameter ribbed bugle
990.0
123.8
1.375 in metal stud
head screw
ET&F 0.100 in. knurled shank X
11284-99/1580
Ramtech
0.3125
48
Min. No. 20 gauge X 3.625 in. X
16
4
8
1.5In. long X 0.25in. head
1227.0
153.4
1.375 In metal stud
diameter pin fastener
ET&F 0.100 in. knurled shank X
11284-9911580
Ramtech
0.3125
48
Min. No. 20 gauge X 3.625 in. X
24
4
8
1.5 long X 0.in. head
1060.0
132.5
1.375 in metal stud
meter pin fastener
diameter
1. All board edges shall be supported by framing. Panels shall be appried with the long dimension either parallel or perpendicular to studs.
2. The maximum height -to -length ratio for construction in this Table is 2:1.
3. In the steel framed assemblies the allowable load is based on the average load at 1/8 inch net deflection.
I!!llq/Z
.0G.4
;Gt l Fl C4--
,� � 22 j,-�
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET 9443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-8474595 FAX
PROJECT: RIO-2556-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
DESIGN WIND LOAD PROCEDURES:
Fiber -cement siding transverse load capacity (wind load capacity) is determined via compliance testing to transverse load national test standards. Via the transverse load testing an allowable
design load Is determined based on a factor of safety of 3 applied to the ultimate test load.
Since the allowable design load is based on factor of safety of 3, allowable design loads on fiber -cement siding correlate directly to required design pressures for Allowable Stress Design, and
therefore should be used with combination loading equations for Allowable Stress Design (ASD).
By using the combination loading equations for Allowable Stress Design (ASD), the.tested allowable design loads for fiber -cement siding are aligned with the wind speed requirements in ASCE 7-
10 Figure 26.5-1A, Figure 26.5.1B, and Figure 26.5-1C.
For this analysis, to calculate the pressures in Tables 3, 4, and 5, the load combination will be in accordance with ASCE 7-10 Section 2.4 combining nominalloads using allowable stress design,
load combination 7. Load combination 7 uses a load factor of 0.6 applied to the wind velocity pressure.
Equation 1, q,=0.002WK�* Kr VVZ
(ref. ASCE 7-10 equation 30.3-11
q, , velocity pressure at height z
K, , velocity pressure exposure coefficient evaluated at height z
Ku , topographic factor
Kd , wind directionality factor
V , basic wind speed (3-second gust MPH) as determined from 12012 IBC, 2014 FBC] Figures 1609A, B, or C; ASCE 7-10 Figures 26.5-1A, B, or C
Equation 2,
V=V' (ref. 2012 IBC & 2014 FBC Section 1602.1 definitions)
V n , ultimate design wind speeds (3-second gust MPH) determined from 12012 IBC, 2014 FBC] Figures 1609A, B, or C; ASCE 7-10 Figures 26.5-1A,
B, or C
Equation 3, p=q.* (GCp GCp) (ref. ASCE 7-10 equation 30.6-1)
GCp , product of external pressure coefficient and gust -effect factor
GCp , product of internal pressure coefficient and gust -effect factor
p , design pressure (PSF) for siding (allowable desgn load for siding)
To determine design pressure, substitute q, into Equation 3,
Equation 4, p=0.00256'K,*Kri VV,. *(GCp GCp)
Allowable Stress Design, ASCE 7-10 Section 2.4.1, load combination 7
Equation 5, 0.6D + 0.6W (ref. ASCE 7-10 section 2.4.1, load combination 7)
D , dead load
W , wind load
To determine the Allowable Stress Design Pressure, apply the load factor for W (wind) from Equation 4 to p (design pressure) determined from equation 4
Equation 6, p®d = 0.6'[p]
Equation 7, pad = 0.6•[0.00256•K,* Ka Kd'V.'*(GCP GCp)]
Equation 7 is used to populate Table 3, 4, and 5.
To determine the allowable ultimate basic wind speed for Hardie Siding in Table 6, solve Equation 7 for V d,
Equation 8, VW, _ (p.,d10.6-0.00256-K,'Kn K,'(GCP GCp))o.s
Applicable to methods specified in Exceptions 1 through 3 of [20121BC, 2014 FBC] Section 1609.1.1., to determine the allowable nominal design wind speed (Vasd) for Hardie Siding in Table
6, apply the conversion formula below,
Equation 9, Vmd = V * (0.6f -' (ref. 20121BC & 2014 FBC Section 1609.3.1)
Vad , Nominal design wind speed (3-second gust mph) (rot. 20121BC & 2014 FBC Section 1602.1)
Table 2, Coefficients and Constants used in Determining V and p,
K,
I
lWall Zone 5
Height (ft)
Exp B
Exp C
Exp D
K.
Kd
GC
G-CPj
0.15
0.7
0.85
1.03
h560
1
0.85
-1.4
0.18
20
0.7
0.9
1.08
1
0.85
-1.4
0.18
25
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
0.7
0.98
1.16
1
0.85
-1 A
0.18
35
0.73
1.01
1.19
1
0.85
-1.4
0.18
40
0.76
1.04
1.22
1
0.85
-1.4
0.18
45
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
0.81
1.09
1.27
1
0.85
-1.4
0.18
55
0.83
111
1.29
1
0.85
-1.4
0.18
60
0.85
'It
1.31
1
0.85
-1.4
0.18
100
0.99
1.26
1 1A3
I h>601
1
1 0.85
1 -1.8
0.18
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-8474595 FAX
PROJECT: RIO-2556-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Tahiti a. allowable stress Deslan - Component and Claddina (C&C1 Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category B,
Wind Speed 3-second gust
100
105
110
115
120
130
140
150
160
170
180
190
1 200
210
Height R)
B
B
B
B
B
B
B
B
B
B
B
B
B
B
0.15
-14.4
-15.9
-17.5
-19.1
-20.8
-24.4
-28.3
-32.5
-37.0
41.7
46.8
-52.1
-57.8
-63.7
20
-14.4
-15.9
-17.5
-19.1
-20.8
-24.4
-28.3
-32.5
-37.0
41.7
46.8
-52-1
-57.8
-63.7
25
14.4
15.9
17.5
-19.1
-20.8
-8.3
32.5
37.0
41.7
46.8
-52.1
-57.8
-63.7
30
-14.4
-15.9
-17.5
-19.1
-20.8j4L3.350.2
8.3
-32.5
-37.0
-41.7
46.8
-52.1
-57.8
-63.7
35
-15.1
-16.6
-18.2
-19.9
-21.79.5
-33.9
-38.6
-43.5
48.8
-54.4
-60.2
-66.4
40
-15.7
-17.3
-19.0
-20.7
-22.630.7
-35.3
-40.1
-45.3
-50.8
-56.6
-62.7
-69.1
45
-16.2
-17.9
-19.6
-21.4
-23.331.7
-36.4
-41.5
46.8
-52.5
-58.5
-64.8
-71.4
50
-16.7
-18.4
-20.2
-22.1
-24.132.7
-37.6
-42.8
48.3
-54.1
-60.3
-66.8
-73.7
55
-17.1
-18.9
-20.7
-22.6
- 44.733.6
-3B.5
-43.8
-49.5
-55.5
-61.8
-68.5
-75.5
-1 .3
- .2
-
--3
.
4.
-5 .
-
-6 .
- .1
100
25.6
28.2
31.0
-33.8
-36.950.2
-57.6
-65.5
-74.0
62.9
-92.4
-102.4
-112.9
Table 4. Allowable Stress Design - Component and Cladding (C&C) Pressures (PSF) to be Resisted at Various Wind Speeds - Wind Exposure Category C,
Wind Speed 3-second gust
100
105
110
115
120
130
140
150
160
170
180
190
200
210
Height (it)
C
C
C
C
C
C
C
C
C
C
C
C
C
C
0.15
-17.5
-19.3
-21.2
-23.2
-25.2
-29.6
-34.4
-39.5
-44.9
-50.7
-56.8
-63.3
-70.1
-77.3
20
-18.6
-22.5
-24.6
-26.7
-31.4
-36.4
-41.8
-47.5
-53.7
-60.2
-67.0
-74.3
-81.9
25
-19.4
-23.5
-25.6
-27.9
-32.8
-38.0
-43.6
-49.6
-56.0
-62.8
-70.0
-77.6
-85.5
30
-20.2
-24.5
-26.7
-29.1
34.2
-39.6
-45.5
-51.8
-58.4
-65.5
-73.0
-80.9
-89.2
35
-20.8
-252
-27.6
-30.0
-35.2
-40.8
-46.9
-53.3
-60.2
-67.5
-75.2
-83.3
-91.9
40
-21.5
K4213.0
-26.0
-28.4
-30.9
-36.3
-42.0
-48.3
-54.9
-62.0
-69.5
-77.4
-85.8
-9445
-22.0
-26.6
-29.1
-31.6
-37.1
43.1
-49A
-56.2
-63.5
-71.2
-79.3
-87.9
-96.9
50
-22.5
-27.2
-29.7
-32.4
-38.0
-44.1
-50.6
-57.6
-65.0
-72.9
-81.255
22.9
-27.7
-30.3
-33.0
-38.7
�4.9
-51.5
-58.6
-66.2
-74.2
-82.7
-91.6
-1,
60
23.3
25.7
28.2
-3 .8
-33.6
-39.4
1i5.7
52.4
59.7
-67.4
-75.5
-84.1
-93.2
- 02.8
100
-32.6
35.9
-39.4
-43.1
-46.9
-55.0
-63.8
-73.3
-83.4
94.1
105.5
-117.6
-130.3
-143.6
7�hie s en.....nhh, ct, .. nestnn . rmmnonent and Claddina (C&C1 Pressures (PSF) to be Resisted at Various Wind Speeds -Wind Exposure Category D,
Wind Speed 3-secondgust)
100
105
110
115
120
130
140
150
160
170
180
190
200
210
Height (it)
D
D
D
D
D
D
D
D
D
D
D
0
D
D
0-15
-21.2
-23.4
-25.7
-28.1
-30.6
-35.9
-41.6
-47.8
-54.4
-61.4
-68.8
-76.7
-85.0
-93.7
20
-22.3
-24.6
-27.0
-29.5
-321
-37.7
-43.7
-50.1
-57.0
-64.4
-72.2
-80.4
-89.1
-98.2
25
-23.1
-25.5
-28.0
-30.6
-33.3
-39.0
-45.3
-52.0
-59.1
-66.8
-74.9
-83.4
-92.4
-101.9
30
-23.9
-26.4
-29.0
-31.6
-34.5
-40.4
-46.9
-53.8
-61.3
-69.2
-77.5
-86.4
-95.7
-105.5
35
-24.5
-27.1
-29.7
-32.5
-35.3
41.5
-48.1
-55.2
-62.8
-70.9
-79.5
-88.6
-98.2
-108.3
40
-25.2
-27.7
-30.5
-33.3
-36.2
-42.5
-49.3
-56.6
1 -64.4
-72.7
1 -81.5
-90.9
-100.7
-111.0
45
.25.7
-28.3
-31.1
-34.0
-37.0
-43.4
-50.3
-57.8
-65.7
-74.2
-83.2
-92.7
-102.7
-113.3
50
-26.2
-28.9
-31.7
-34.6
-37.7
44.3
51.3
-58.9
-67.1
-75.7
-84.9
-94.6
-104.8
-115.5
55
-26.6
-29.3
-32-2
-35.2
-38.3
-45.0
-52.2
-59.9
-68.1
-76.9
-B6.2
-96.1
-10214
-117.4
60
2 .0
2.
5 .
-60.8
2
1
87.6
-
1 .1
-1
100
-37.0
-40.8
-44.7
-48.9
-53.2
-62.5
-72.5
-83.2
-94.6
-106.8
-119.8
-133.4
-147.9
-163.0
Tables 3, 4, and 5 are based on ASCE 7-10 and consistent with the 2012 IBC, 2012 IRC and the 2014 Florida Building Code
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-8474595 FAX
PROJECT: RIO-2556-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 6, Allowable Wind Speed (mph) for HardiePanel Siding (Analytical Metho
Product
Product
Thickness
inches
(inches)
Width
(inches)
Fastener
Type
Fastener
Spacing
Frame
Type
Stud
Spacing
(inches)
Building
Height''
(feet)
)
B
C
J
D
B
C
D
Allowable
Design
Load
(PSF)
Exp B
Exp C
Exp D
Ka
Ka
GCp
GCp
HardiePanel®
5/16
48
6d
Common
6
2X4
wood
Hem -Fir
16
0-15
186
168
153
144
130 1
118
49.7
0.7
0.85
1.03
h560
1
1
0.85
0.85
-1.4
-1.4
0.18
0.18
20
186
164
149
144
127
116
49.7
0.7
0.9
1.08
25
186
160
147
144
124
114
49.7
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
186
157
144
144
121
112
49.7
0.7
0.98
1.16
1
0.85
AA
0.18
35
182
154
142
141
120
110
49.7
0.73
1.01
1.19
1
0.85
-1A
0.18
40
178
152
141
138
118
109
49.7
0.76
1.04
1.22
1
0.85
-1.4
0.18
45
175
150
139
136
117
108
49.7
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
172
149
138
134
115
107
49.7
O.B7
1.09
1.27
1
0.85
-1A
0.18
55
170
147
137
132
114
106
49.7
0.83
1.11
129
1
0.85
-1.4
0.18
60
168
146
136
130
113
105
49.7
0.85
1.13
1.31
1
0.85
-1.4
0.18
100
139
124
116
108
96
90
49.7
0.99
1.26
l A3
h>60
1
0.85
-1.8
0.18
HardiePanelO
5/16
46
6d
common
4
2X4
wood
Hem -Fir
16
0-15
233
. 212
192
181
164
149
-78.7
0.7
0.85
1.03
h560
t
1
0.85
0.85
-1.4
-1.4
0.18
0.18
20
233
206
188
181
159
146
-78.7
0.7
0.9
1.08
25
233
201
185
181
156
143
-78.7
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
233
197
181
181
153
140
-78.7
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
229
194
179
177
151
139
-78.7
0.73
1.01
1.19
1
0.85
-1.4
0.18
40
224
192
177
174
148
137
-78.7
0.76
t.04
1.22
1
0.85
-1.4
0.18
45
220
189
175
171
147
136
-78.7
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
4
187
173
3
145
134
-78.7
0.81
1.09
127
1
0.85
-1.4P0.1
55
214
185
172
166
144
133
-78.7
0.83
1.11
t 29
1
0.85
-1.4
60
212
184
171
164
142
132
-78.7
0.85
t.13
1.31
1
0.85
-1.4
100
175
155
146
136
120
113
-78.7
0.99
1.26
1.43
h>60
1
0.85
-1.8
HerdiePanel�
5/16
46
6d
Common
6
2X4
wood
Hem -Fir
24
0-15
147
134
121
114
103
94
-31.3
0.7
0.85
1.03
hs6O
1
1
0.85
0.85
-1.420
-1.425
6-7
130
119
32659
101
92
-31.3
0.7
0.9
1.08
7
127
116
5
98
90
-31.3
0.7
0.94
1.12
1
0.85
-1.4
30
147
124
114
114
96
89
-31.3
0.7
0.98
1.16
1
0.85
1 AA
0.18
35
144
123
113
112
95
87
-31.3
0.73
1.01
1.19
1
0.85
AA
0.18
40
141
121
112
109
94
86
31.3
0.76
1.04
1.22
1
0.85
-1.4
0.18
45
139
119
110
108
92
86
31.3
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
137
118
109
106
91
85
-31.3
0.81
1.09
1 1.27
1
0.85
-1.4
0.18
55
135
117
108
105
91
84
31.3
0.83
1.11
1 1.29
1
0.85
-lA
0.18
60
134
116
108
103
90
83
-31.3
0.85
1.13
1.31
1
025
AA
0.18
100
111
98
92
86
76
71
-31.3
0.99
1.26
1A3
h>60
1
0.85
-1.8
0.18
HardiePanel®
5/16
48
6d
common
4
2X4
wood
Hem -Fir
24
0-15
182
165
150
141
128
116
47.7
0.7
0.85
1.03
h56O
1
1
0.85
0.85
-1.4
AA
0.18
0.18
20
182
160
146
141
124
113
47.7
0.7
0.9
1.08
25
182
157
144
141
121
111
47.7
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
182
154
141
141
119
109
47.7
0.7
0.98
1.16
1
0.85
-1.4
10.18
35
178
151
139
138
117
108
47.7
0.73
1.01
1.19
1
0.85
-lA
0.18
40
174
149
138
135
116
107
47.7
0.76
1.04
1.22
1
0.85
-1.4
0.18
45
172
147
136
133
114
106
47.7
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
169
146
135
131
113
105
47.7
0.81
1.09
127
1
0.85
-1 A
0.18
55
167
144
134
129
112
104
47.7
0.83
1.11
129
1
0.85
-1.4
0.18
60
165
143
133
128
111
103
47.7
0.85
1.13
1.31
1
B-s
AA
0.18
100
137
121
114
106
94
88
47.7
0.99
1.26
1.43
h>60
1
OAS
1 -1.8
0.18.
HardiePanel®
5/16
48
4d, 0.091
In. shank X
0.225 in.
HD X 1.5
in. long ring
shank nail
4 edge
8 field
2X4
wood
SG>0.36
16
0-15
144
131
119
112
101
92
-30.0
0.7
0.85
1.03
h<_60
1
1
0.85
0.85
-1.4
-1.4
0.18
10.18
20
144
127
116
112
98
90
30.0
0.7
0.9
1.08
25
144
124
114
112
96
88
-30.0
0.7
0.94
1.12
1
0.85
-1.4
10.18.
30
144
122
112
112
94
87
-30.0
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
141
120
111
109
93
86
-30.0
0.73
1.01
lA9
1
0.85
-1.4
0.18
40
138
118
109
107
1 92
85
30.0
0.76
1.04
1.22
1
0.85
-1.4
0.18
45
136
117
108
105
91
84
30.0
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
134
116
107
104
89
83
30.0
0.81
1.09
1.27
1
0.85
AA
0.18
55
132
114
106
103
B9
82
30.0
0.83
1.11
1.29
1
0.85
AA
0.18
60
131
113
105
101
88
82
30.0
0.85
1.13
1.31
1
0.85
AA
0.18
100
108
96
90
84
74
70
30.0
0.99
1.26
1.43
h>60
1
0.85
-1.8
0.18
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2556-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
o\o�\uu[unrrrn��///
2012 IBC. 2014 FBC
2012 IBC, 2014 FBC
_ 241 2
Allowable, Ultimate
Design Wind, Speed,
Allowable, Nominal
Design Wind, Speed,
_-
(3-second gust mph)
5.e
V.
(3-second gust mph)
_ a1
'ZZ
`•'/�n••'•.LO RIDP•'
Applicable to methods
specified in 012 Ied
methods
to lExceptions1
,
/V >\�```\`
2014 FBCI section
spedfiApplicabe
Exo t
1609.1.1. determined by
through 3 of [2012 IBC,
as
2014 FBC] Section
12012 IBC, 2014 FBC]
1609.1.1.
Figures 1609A, B, or C.
Coefficients used in Table 6 calculations for V,
Wind exposure category
Wind exposure categoryl
Siding
K,
Product
Stud
Building
Allowable
Product
Thickness
width
Fastener
Fastener
Frame
Spacing
Heigh
B
C
D
B
C
D
Design
(inches)
(inches)
Type
Spacing
Type
(inches)
(feet)
Load
(PSF)
Exp B
Ecp C
ExD D
Kn
Ka
GC•
GCa
0-15
19B
180
163
153
139
126
-56.6
0.7
0.85
1.03
hS60
1
0.85
-1.4
10.18
20
198
175
159
153
135
123
-56.6
0.7
0.9
1.08
1
0.85
-1.4
10.18
Min. No 8 X
Min. No.
1
25
198
171
157
153
132
121
-56.6
1 0.7
0.94
1,12
1
0.85
-1.4
0.18
1 In. long X
20 gauge
30
198
167
154
153
130
119
-56.6
0.7
0.98
1.16
1
o.a5
-1.4
10.18
0.323 in
X 3.625
35
194
165
152
150
128
118
-56.6
0.73
1.01
1.19
1
0.85
AA
0.18
HardiePanel0
114
48
head
6
in. X
16
40
190
162
150
147
126
116
56.6
0.76
1.04
1.22•
1
0.85
-1.4
0.18
diameter
1.375 in
45
187
161
148
145
124
115
-56.6
0.785
1.065
1245
1
0.85
-1.4
0.18
ribbed
metal
50
184
159
147
143
123
114
-56.6
0.81
1.09
1.27
1
0.85
-1.4
0.18
bugle head
stud
55
182
157
146
141
122
113
-56.6
0.83
1.11
1.29
1
0.85
-1.4
0.18
screw'
60
180
156
145
139
121
112
-56.6
0.85
1.13
1.31
7
6.85
-1.4
0.18
100
149
132
124
115
102
96
-56.6
0.99
1.26
1.43
h>60
1
0.85
-1.8
0.18
0-15
146
132
120
113
102
93
-30.6
0.7
0.85
1.03
hs60
1
0.85
-1.4
0.18
20
146
128
117
113
99
91
-30.6
0.7
0.9
1.08
1
0.85
-1.4
0.18
Min. No 8 X
Min. No.
25
146
126
115
113
97
89
30.6
0.7
0.94
1.12
1
0.85
-1.4
0.18
1 In. long X
20 gauge
30
146
123
113
113
95
88
-30.6
0.7
0.98
1.16
1
0.85
-1.4
0.18
0.323 In
X 3.625
35
143
121
112
110
94
86
-30.6
0.73
1.01
1.19
1
0.85
-1.4
0.18
HardiePanel®
1/4
48
head
6
in. X
24
40
140
119
110
108
93
85
30.6
0.76
1.04
1.22
1
0.85
-1.4
0.18
diameter
1.375 in
45
137
118
109
106
91
85
30.6
0.785
1.065
1.245
1
0.65
-1.4
0.18
ribbed
metal
50
135
117
108
105
90
84
30.6
0.81
1.09
1.27
1
0.85
-1.4
0.18
bugle head
stud
55
134
116
107
104
90
83
30.6
0.83
1.11
1.29
1
0.85
-1A
0.18
screw'
60
132
115
106
102
89
82
30.6
0.85
1.13
1.31
1
0.85
-1.4
0.18
100
109
97
91
85
75
70
30.6
0.99
1.26
1A3
h>60
1
0.85
-1.8
0.18
0-15
198
180
163
153
139
127
-56.7
0.7
0.85
1.03
hs60
1
0.85
-1.4
0.18
ET&F
20
198
175
160
153
135
124
-56.7
0.7
0.9
1.08
1
0.85
-1.4
0.18
0.100 in.
Min. No.
25
198
171
157
153
132
121
-56.7
0.7
0.94
1.12
1
0.85
-1.4
0.18
knurled
20 gauge
30
198
167
154
153
130
119
56.7
0.7
0.98
1.16
1
0.85
-1.4
0.18
shank X
X 3.625
35
194
165
152
150
128
118
56.7
0.73
1.01
1.19
1
0.85
-1.4
0.18
HardiePanel@
5116
48
1.5 in. long
4 edge
in. X
16
40
190
163
150
147
126
116
56.7
0.76
1.04
1.22
1
0.85
-1.4
0.18
X in.
8 field
1.375 in
45
187
161
149
145
124
115
-56.7
0.785
1,065
1.245
1
0.85
-1.4
0.18
head
head
metal
84
159
147
143
123
114
-56.7
0.81
1.09
1.27
1
0.85
-1.4
0.18
diameter
stud
82
157
146
141
122
113
-56.7
0.83
1.11
1.29
1
0.85
-1.4
0.18
pin
fastenerz
80
156
145
139
121
112
-56.7
0.65
1.13
1.31
1
0.85
-1.4
0.18
49
132
124
115
102
96
-56.7
0.99
1.26
1A3
h>60
1
0.85
-1.8
0.16
53
139
126
118
107
98
33.7
0.7
0.85
1.03
h<_6o
1
0.85
1-1.4
0.18
ET&F
53
135
123
118
104
95
33.7
0.7
0.9
1.06
1
0.65
-7.4
0.76
0.100 in.
Min. No.
53
132
121
118
102
94
33.7
0.7
0.94
1.12
1
0.85
-1.4
0.18
knurled
20 gauge
53
t14
129
119
118
100
92
-33.7
0.7
0.98
1.16
1
0.a5
-1.4
0.18
shank X
1.5 in. long
4 edge
X 3.625
50
127
117
116
99
91
-33.7
0.73
1.01
1.19
1
0.85
-1.4
0.18
47
125
116
114
97
90
-33.7
0.76
1.04
1.22
1EO.85
-14
018
HardlePanel@
5/16
48
X 0.25 in.
6 Held
in. X
24
44
124
115
112
96
89
33.7
0.785
1.065
1.245
1head
1 375 in
42
122
113
110
95
88
-33.7
0.81
1.09
1.27
1diameter
metal
40
121
113
109
94
87
33.7
0.83
1.11
1.29
1pinfastenerz
stud
39
120
112
107
93
87
33.Z
0.65
1.13
1.31
115
102
95
89
79
74
-33.7
0.99
1.26
1A3
h>60
1
1. Screws shall
Denetrate the
metal framing
at least
three full
threads.
2. Knurled shank pins shall penetrate the metal framing at least 1/4 inch.
3. Building height = mean roof height (in feet) of a building, except that eave height shall be used for roof angle O less than or equal to 10• (2-12 roof slope).
4. Vult = the ultimate design wind speed (3-second gust mph) as determined by 12012 IBC, 2014 FBC] Figures 1609A, 1609B, or 1609C: ASCE 7-10 Figures 26.5-1A, 26.5-1 B, or 26.5-1C.
5. Vasd = the nominal design wind speed applicable to methods specified in Exceptions 1 through 3 of [2012 IBC, 2014 FBC] Section 1609.1.1.
6. The wind speeds In [2012 IBC, 2014 FBC] Figures 1609A, 1609B and 1609C are ultimate design wind speeds, Vult, and shall be converted in accordance with [2012 IBC, 2014 FBC] Section 1609.3.1
to nominal design wind speeds, Vasd, when the provisions of the standards referenced in [2012 IBC, 2014 FBC] Section 1609.1.1. Exceptions 1 through 3 are used.
7. Linear Interpolation of building height and wind speed is permitted.
B. Wind speed design assumptions per Analytical Method in ASCE 7-10 Chapter 30 C&C Part 1 and Part 3: Itd=1, Kd=0.85, GCP -1.4 (hs60), GCP -1.8 (h>60), GCoi=0.18.
LIMITATIONS OF USE:
1) Fastener pullout must be evaluated when installed a species of wood studs other than that which was tested.