Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERATOR APPROVAL
16/20/22 kW .,Tr. LUCIE COUNTY SUILDINC DIVISION RIEVIEW217 tFOF1 C9*9YRT REVIEWEWBY ='- DATE PLANS AND PERMIT ..irc-r RF KEPT ON JOB OR NO INS INCLUDES: I_- • True Power m Electrical Technology • Two Line LCD Multilingual Digital Evolution"m Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure GENERAL' GUARDIAN° SERIES lential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 2210 60 Hz 'GENERAC' 1�=5 • Flexible Fuel Line Connector ,A�--�K • Direct -To -Dirt Composite Mounting Pad --�-r • Natural Gas or LP Gas Operation C(S)US LISTED QUIff y • 5 Year Limited Warrant Note: CUL certilicalion only applies to unbundled units and units packaged with • Capability to be installed within 18" (457 mm) the USA only switches. Units packaged with the Smart Switch are UL certified in of a building* *Only If located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and.reliability for when you need it the most. The G-force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions, O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed WAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This slate -of -the -art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM -MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are ✓ PROTOTYPE TESTED ✓ NEMA MG1•22 EVALUATION synonymous with GENERAC POWER SYSTEMS, One reason for this J SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence Is that the GENERAC product line Includes Its own transfer systems and controls for total system compatibility. Lu GENERAC►� •36s LL�y ��� _ !�®• *©* Mobile ' f— PROMISE r�afi�fi'P �gHPA� Link „' • Bu/RN NI W4 udnp domaNe Nd lon/P MO. 16/20/22 kW � 1 GENERAC� features and benefits Engine • Generac G-Force design Maximizesengine "breathing" forincreased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. ♦ Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25`Yo more efficiently than a revolving armature generator. ♦ Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (If applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost Installation. Evolution'" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication In any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility Interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- Ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 180 away from a building. Installation System ��rsrilG; 4,."'dti • 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERAC 16/20/22 kW specifications Generator 0007035.0,6007036.0, G007038.0,G007039-0 0007042.0,G007043.0 Model G007037-0 (16 I(W) (20 I(W) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts' 20,000 Watts' 22,000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts" 18,000 Watts' 19,500 Rated Voltage 240 240 240 Rated Maximum Continuous Load Current — 240 Volts (LP/NG) 66.6/66.6 83.3/75 Less than 6% 91.6/81.3 Less than 5% Total Harmonic Distortion Less than 5% 70 Amp 100 Amp 100 Amp Main Line Circuit Breaker 1 1 1 Phase 2 2 2 Number of Rotor Poles 60 Hz 60 Hz 60Hz Rated AC Frequency 1.0 1.0 1.0 Power Factor 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Battery Requirement (not included) 406/186 44B/203 466/211 Unit Weight (lb/kg) 48 x 25 x 29/1218 x 638 If 732 Dimensions (L If W x H) in/mm Sound output in dB(A) at 23 if (7 m) with generator operating at normal load" 66 66 67 Sound output in dB(A) at.2311t(7 m) with generator in Quiet -Test'" low -speed exercise mode" 68 58 58 Exercise duration 5 min 5 min 5 min Engine GENERAC G Force 1000 Series Type of Engine i 2 2 2 Number of Cylinders 999 cc 999 cc 999 cc Displacement Aluminum w/ Cast Iran Sleeve Cylinder Block ! Overhead Valve Overhead Valve Overhead Valve Valve Arrangement Solid-state w/ Magneto Solid-state w/Magneto Solid-state w/ Magneto Ignition System Electronic Electronic Electronic Governor System 9.5:1 9.5:1 9.5:1 Compression Ratio 12 Vdc 12 Vdc 12 Vdc Starter Oil Capacity Including Filter,• ' Approx.1.9 gV1.8 L Approx.1.9 gV1.8 L Approx. 1.9 gV1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption it'/hr (m3/tlr) Natural Gas i 1/2 Load 218 (6.17) 204 (6.78) 216 (6.12) Full Load 309 (8.75) 301 (8.52) .310 (8.78) Liquid Propane ON WIN) Phil 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8.99] 93.2 (2.56) [9.70] I Full Load 106.8 (2.94) [11.111 129.6 (3.56) [13.4B] 140 (3:87) (14.65] I Note; Fuel pipe must be stied for full food. Required fuel pressure to generator fuel Inlet a( all toad ranges - 3.5-71 water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury) for LP gas For Btu content multiply fta/hr x 2500 (LP) or 11%x 1000 (NG).For Megaloule content, multiply m3/hr x 93.15 (LP) or m3/hr x 3726 (NG) Controls 2-Line Plain Text Multilingual LCD Display Mode Bultons;Aulo ? j Manual Off Ready to Run/Maihtertance Messages Engine Run Hours Indicatior ; Programmable start delay between 2-1500 seconds Utility Voltage Loss/Return to Utility Adjustable (Brownout Selling) Future Set Capable Fxerctser/Ezercise Set Error Warning RurVAlarm/Mainlenance Logs Engine Start Sequence Starter Lock -out Smart Battery Charger Charger Faull/Mlssing AC Warning Low Batlery/Baltery Problem Protection and Battery Condition Indication Automatic Voltage Regulation withtiOver and Under Voltage Protection Under-Frequency/Overload/Slepper Overcurrent Protection Safety.Fused/Fuse Problem Protection Automatic Low Oil Piessure/High Oil Temperature Shutdown Overcrank/Overspeed (@ 721114/0m Sense Loss Shutdown High Engine Temperature Shutdown Internal FaultAncofreetWiring P(oleolion Common External Fault Capability Paid U milable Firmware ' 1 1 - ' r. Simple user Interface for ease of operation. Automatic Start on Utility failure, 7 day exerciser. Start with starter control, unit stays on. If utility fails, transfer to load lakes place, Slops unit. Power Is removed. Control and charger still operate. Standard Standard Standard (programmable by dealer only) From 140471 V/19D-216 V Standard 50 Events Each Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration). Slarler cannot re-engage until 5 sec alter engine has stopped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard P9 : 1 "Sound levels are Wren from thefrontol b generator, Sound levels to ran from other sides of the generator maybe higher depending on installation parameters. Rating definllions• Standby. Appllabietor supplying emergencypower for thoduraeon of the utility power outage. Noovedoadcapability Is=liableforrhisraruig.(AllradngsInaccordancewithB55514,1803046andDIN6271).'MMmdmumulovoltampsandcurentaresubjecttoandlimitedbysuchfactorsasfuelBW/megaloule conlen4 ambient temperature, altitude, engine powerand condition, etc. Mardmum power derxeasesabout3.5 pettxnlror each 1,000feet(304.8 melets) above sea level; and also will deaeaseaboult percent [or each6 °C (10 IF)above 16°C (609. GENERACA 16/20/22 kW, Limited Circuits Switch Features • 16 circuits, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive, • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are sliver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive Install. Dimensions Height Width Depth H1 H2 W1 W2 In 26.75 30.1 10.5 13.5 6.91 1 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lu���2/0 round Lug 1/0-#14-#14 �#14��2/0 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both Inductive and resis- tive. • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, ie. Open Transition Service Rated Height H1 H2 Width W1 W2 Depth in 26.75 30.1 10.5 13.5 6,91 mm 679A 704.3 266.7 343.0 175.4 switch options Model G007036.0 (1160) No. of Poles 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240,1 H Utility Voltage Monitor (Fixed)' -Plck-up 80% -Dropout 65% Return to Utility' approx. IS sec Exercises bi-weekly for 5 minules't Standard UL Listed Standard Total Circuits Available 16 Tandem Breaker Capabilities 8 spaces Circult Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly Model G007037.0 (16 kW)/G007039.0 (20 kW)/ G007043.0 (22 kW) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240.10 Utility Voltage Monitor (Fixed)` -Pick-up 80% 65% -Dropout Retum to Utility approx.13 sec Exercises bi-weekly for 5 minutes* Standard UL Listed Standard Enclosure Type NEMANL 3R Circuit Breaker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly DePTH GENERAL° 16/20/22 kW specifications Generator G007035.0,G007036-0, 1113007038.0,(1007039-0 G007042-0,G007043.0 Model G007037.0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Walls- 20,o0D Walls* 22,000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts- 18,000 Watts' 19,600 Rated Voltage i , 240 240 240 • Rated Maximum Continuous Load Current — 240 Volts (LP/NG). 66.6/66.6 83.3/75 91,6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 10D Amp Phase 1 1 1 2 2 2 Number of Rotor Pales 60 Hz 60 Hz 60Hz Rated AC Frequency 1.0 1.0 1.0 Power Factor Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight (lb/kg) 406/186 448/203 466/211 Dimensions (L x W x H) INrnm 48 x 25 x 29/1218 x 638 x 732 , Sound output in dB(A) at 23 It (7 m) with generator operating at normal load" 66 66 67 Sound output in dB(A) at 231it•(7 m) with generator In. Quiet -Test" low -speed exercise mode'" 58 58 58 Exercise durallon 5 min 5 min 5 min Engine Type of Engine GENERAL G-Force 1000 Series Number of Cylinders 2 2 2 999 cc 999 cc 999 cc Displacement Aluminum w/ Cast Iron Sleeve Cylinder Block Overhead Valve Overhead Valve Overhead Valve Valve Arrangement Ignition System Solid -slate w/ Magneto Solid -stale w/ Magneto Solid -stale w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 12 Vdc 12 Vdc 12 Vdc Starter Oil Capacity Including Mild '• Approx.1.9 gU1.8 L Approx.1.9 gI/1.8 L Approx.1.9 gI/1.8 L Operating rpm 3,600 3,600 3,600 Fuel Consumption 1 Natural Gas f W/hr (m?/hr) 1/2 Load 218 (6,17) 204 (5.78) 216 (6.12) I Full Load 309 (8,75) 301 (8.52) 310 (8.78) Liquid Propane ON WIN) [Vhr] 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8,99] 93.2 (2.56) 19.701 Full Load 106.8 (2.94) [11.111 129.6 (3.56) [13.481 140 (3.87) (14.651 Note: Fuel pipe must he shed for full load. Required fuel pressure to generator fuel Inlet at all load ranges - 3.5-7° water column (7-13 min mercury) for natural gas, 10-12' water column (19-22 mm mercury) for LP oas For Btu content multiply (l3/hr x 2500 (LP) or Uakr x 1000 (NG) For Megaloule content multiply ma/hr x 93.15 (LP) or ma/hr If 37,26 ING) Controls 2-Line Plain Text Multilingual LCD Display Simple user Interface for ease of operation. Mode Bultons:Auto Automatic Start on Utility failure. 7 day exerciser. Start with starter control, unit slays on. If utility falls, transfer to load lakes place. Manual Off Stops unit. Power Is removed, Control and charger still operate. Ready to Run/Mainleriance Messages Standard Standard Engine Run Hauls Indication; ; Progtammable slarl delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to UIIII(y Adjustable (Brownout Setting) From 140471 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard Run/Alamr/Malntenance Logs ! 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration). Starter Lock out ; Starter cannot re-engage until 5 sec after engine has slopped. Smart Battery Charger Standard Charger FaulVMissing AC Warning ; Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation withbverand Under Voltage Protection Standard Under-Frequency/Overload/Stepper 0vercurrent Protection Standard Safety Fused/Fuse Problem Prol'ection Standard Automatic Low Oil Pressure/High till Temperature Shutdown Standard Overcrank/Overspeed (@ 72111z)/r in Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal FaultAncorrecl Wiring Protection Standard Common External Fault Capability '•"�%,4�"'•: Standard -''' Standard Field Upgradable Flmiware ; 1 1 •'Sou�d Ievelsaretalmn Item the frcntof the generator. Sound levelstalmn from other sides of the generator may be higher depending on installation parameters. Rating definitions -Standby. Appllabletor supptyir p emergenry power forthe duration Inand DIN6271).'MadmumNlovoltamps and aurentamsubject toand limited bysuch lactmsasfuel IlhAmegaloule oflhe"uy`Iilypower outage. Nooverfoadapab8ilyIsavailable lot this rating. (All ratings accordance wilheS5514,IS03046 Mapmum decreases about3.5 percent for each 1,000 feet(304.8 meters) above sa level; and also will decrease about percent for each 6 10 (10IF) above 18°D (6D`F). contents"ambient temperature, atfitude, engine power and candltion, etc. power [11 GENERACA 16/20/22 kW . Limited`Circuits Switch Features • 16 circuits, breakers not Included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 11, standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height Width Depth Hi H2 W1 W2 In 26.75 30.1 10.5 13.5 6.91 mm 679.4 76463 266.7 343.0 175A Wire flanges Conductor Lug Neutral Lug Ground#Lug 1/0-#14 2/0-#14 210- Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). 0 Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resis- tive. • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or sliver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 120/240,1eon Service RatedWidth M W1 W210.5 Depth 13.6 6.91 66.7 343.0 175.4 switch options Model 6007036.0 (16kM No. of Poles 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)* -Pick-up 80% 65% -Dropout Return to Utility* approx.15 sac Exercises bi-weekly for 5 minules*t Standard UL Listed Standard Total Circuits Available 16 Tandem Breaker Capabilities 8 spaces Circuit Breaker Protected Available RMS Symmetrical 10,000 Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly Model No. of Poles Current Rating (Amps) Voltage Rating (VAC) UtilityVoltage Monitor (Fixed)* -Pick-up -Dropout Return to Utilil* Exercises bi-weekly for 5 minutes* UL Listed Enclosure Type Circuit Breaker Protected Lug Range 0 039 0 20 kW / G007037.0 (16 kW)/GO 7 - ( ) G007043.0 (22 kW) 2 200 120/240,10 *Function of Evolution Controller Exercise can be set to weekly or monthly oePm 80% 65% approx.13 sec Standard Standard NEMA/UL3R 22.000 250 MGM - #6 16/20/22 kW GENERAC available accessories Model # product Description Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463.4 Mobile Link'" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet G005819-0 26R Wet Cell Battery cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 ;Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use If the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below G007102-0 till Wanner 0°F. The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers G007103.0 Breather Warmer only in climates where heavy Icing occurs. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a Fascia Base Wrap Kit G007027-0 - Bisque sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting (Standard on 22 kW) holes located In the base. If the generator enclosure Is scratched -or damaged, It is Important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase Its Smart Management Module power management capabilities. Itprovides additional power management flexibility not found in any other (50 Amps) power management system. dimensions & PCs Olmenslons shown are approximate. Refer to insulation manual for exact dimensions. 00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE view raga im MONTMEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENE RAC' Generac Power Systems, Inc. - 545 W29290 HWY. 59, Waukesha, WI 53189 - generac.com 02015 Generac Power Systems, Inc. Ali rights reserved. All specifications are subject to change without notice. Part No. 10000000194.010124/16 agement Modules (SMM) GENERAL" GENERAC® ACCESSORIES Model G006873-0 C@US LISTED DESCRIPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if It falls below a certain threshold, the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage, therefore reducing the necessary size'of the generator for a more cost effective solution. SMM SPECIFICATIONS PowerSupply Source............................................................................................................................................................................................................ 240 VAC (from Line input) SupportedVoltages..........................................................................................................................................................................................................................................240 VAC Contactor Coil Voltage CoilVA Inrush....................................................................................................................................................................................................................................................................................................240 VAC ................................................................................................................................................................................I............ 30 Coil VA Sealed .................................................... ................................................,.................................,.,.....................,....................,........,..................................................,....................................................... 6.5 Poles ResistiveAmps......................................................................................................................................................................................................................................................... 2 . F/L Inductive Amps........................................................................................................................................................................................................................................................................................................................... 50 LockedRotor Amps...................................................................................................................................................................240V UI50....................................................................................................................................................................................................................................................................... Yes EnclosureRating.............................................................................................................................. GENERAC® GENERACO Smart Management Modules (SMM) Dimensions and UPC Model G006B73-0 Height (INmm) H1 6.17/156.8 H2 2.36/60 Width (INmm) W 1 W2 7.06/179.4 4.72/120 Depth (In/mm) 3.7/94 Weight (lbs/kilos) 2.06/0.94 Shipping Weight (lbs/kilos) 2.44/1.11 UPC Code 696471068733 H1 SMM Controls (located behind the cover of the module) I LED ON - LOAD CONNECTED LED FLASH IS - LOAD SHED PRIORITY LOCKOUT LOAD ON LED FLASH 3S = 30 MIN LOCKOUT 6 GENERATOR LED FLASH 6S o GEN LOAD LOCKOUT a 7 .--- LED OFF = NO MODULE POWER A ® ® o Oo I TEST 0 LOOKOUT DISABLED Priority Dial (A) — Sets m3dule priority. Lockout Switch (B) — Prevents load from operating when system is operating under generator power. Test Button (C) — Disables contactor output for a specified time. Provides module status with easy viewing through the exlernal viewing window LED (D) — located in the upper right corner of the module. Generac Power Systems, Inc. - 645 W29290 HWY. 59, Waukesha, WI 53189 - generac.com GENERAC- 02016 Generac Power systems, Inc. An rights reserved. An specifications are subject to change without notice. Bunelin OL1500 03/10/16 r � 1 Site Selection and Preparation Section 3: Site Selection and Preparation Site Selection II I i 5ft(1.52m) C 5ft(1.52m) r r , 3ft 3ft B (0.91 m) O '-(0.91 m) O 3ft(0.91 m) OO i B F , mt1ll. rrl_ Figure 3-1. Installation Clearances ID Description Comments A Top of generator — B Front and end clearance Minimum clear distances cannot include shrubs, bushes, or trees. C Rear clearance 18 In (45.7 cm) minimum clearance per NFPA testing, labeling, and listing, unless state or local codes dictate otherwise. D Windows and openings No operable windows, doors, or openings in the wall are permitted within 5 ft (1.52 m) from any point of the generator. E Existing wall One -hour fire rated walls allow closer placement of the generator set. Confirm before Installation. F Removable fence Removable fence panels for servicing cannot be placed less than 3 ft (0.91 m) in front of the generator. G Overhead clearance 5 ft (1.52 m) minimum distance from any structure, overhang, or projections from the wall. DO NOT Install under wooden decks or structures unless this distance Is maintained. Installation Guidelines For 60 Hz Air -Cooled Generators 11 Site Selection and Preparation 1 Install the generator set, In its protective enclosure, outdoors where adequate cooling and ventilating air is always available (Figure 3-1). Consider these factors: The installation of the generator must comply strictly with ICC IFGC, NFPA 37, NFPA 54, NFPA 58, and NFPA 70 standards. • Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc. If prevailing winds will cause blowing or drifting, consider using a windbreak to protect the unit. • Install the generator on high ground where water levels will not rise and endanger it. This unit should not operate in or be subjected to standing water. • Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed in accordance with any local, state, or national codes for minimum distances from other structures. • Clearance from the ends and front of the generator must be 3 ft (0.91 m). This includes shrubs, bushes, and trees. Clearance from the back of the generator must be a minimum of 18 in (457 mm). Clearance at the top should be a minimum of 5 ft (1.52 m) from any structure, overhang, or projections from the wall. • DO NOT install under wooden decks or structures unless there is at least 5 ft (1.52 m) of clearance above the generator. • Install the unit where rain gutter down spouts, roof run-off, landscape irrigation, water sprinklers, or sump pump discharge does not flood the unit or spray the enclosure, including any air inlet or outlet openings. • Install the unit where services will not be affected or obstructed, including concealed, underground, or covered services such as electrical, fuel, phone, air conditioning, or irrigation. This could affect warranty coverage. • Where strong prevailing winds blow from one direction, face the generator air inlet openings to the prevailing winds. • Install the generator as close as possible to the fuel supply to reduce the length of piping. REMEMBER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. In the absence of local codes regarding placement or clearance, we recommend following these guidelines: — Install the generator as close as possible to the transfer switch. REMEMBER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. — The generator must be installed on a level sur- face. The generator must be level within a 0.5 in (13 mm) all around. — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete pad. Check local codes to see what type is required. If a concrete pad is required, all appli- cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 is the The National Fire Protection Association's standard for the installation and use of stationary combustion engines. Its requirements limit the spacing of an enclosed generator set from a structure or wall (Figure 3-1). NFPA 37, Section 4.1.4, Engines Located Outdoors: Engines, and their weatherproof housings if provided, that are installed outdoors shall be located at least 5 ft (1.52 m) from openings in walls and at least 5 ft (1.52 m) from structures having combustible walls. A minimum separation shall not be required where the following conditions exist: 1. The adjacent wall of the structure has a fire resistance rating of at least one hour. 2. The weatherproof enclosure is constructed of noncombustible materials and it has been demonstrated that a fire within the enclosure will not ignite combustible materials outside the enclosure. Annex A -- Explanatory Material A4.1.4 (2) Means of demonstrating compliance are by means of full scale fire test or by calculation procedures. Because of the limited spaces that are frequently available for installation, it has become apparent that exception (2) would be beneficial for many residential and commercial installations. With that in mind, the manufacturer contracted with an independent testing laboratory to run full scale fire tests to assure that the enclosure will not ignite combustible materials outside the enclosure. NOTE: Southwest Research Institute testing approves 18 in (457 mm) installation minimum from structure (Figure 3-1, C). Southwest Research Institute is a nationally recognized third party testing and listing agency. The criteria was to determine the worst case fire scenario within the generator and to determine the ignitability of items outside the engine enclosure at various distances. The enclosure is constructed of non-combustible materials, and the results and conclusions from the _sindependent testing lab indicated that any fire within the 12 Installation Guidelines For 60 HzAir-Cooled Generators Site Selection and Preparation generator enclosure would not pose any ignition risk to nearby combustibles or structures, with or without fire service personnel response. Em80 ID Ida f320"M -d44..14twt BFA 31 US= BY. Gw Resemch imtit ft sm A ft*, Tom �- NOTE 1 (30 CHAR NA10-- NOTE 2 130 CHAR. MW-- NOTE 3 130 CHAR NA)Q--- ----"-� NOTE 4 130 CHAR. MA*—— NOIE 6 (30 CHAR MW--- NOTE S 130 CHAR NA)Q- -- ® NOTE 7 130 WA MA - Oeme PMM Mm IYc WAtNMK W1 USA SM a.2157 Figure 3-2. Southwest Research institute Marking http:/M+ww.swri.org/4org/dOflrirelllstiabAistprod/dimctor htm Based on this testing and the requirements of NFPA 37, Sec 4.1.4, the guidelines for installation of the generators listed above are changed to 18 in (457 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and airflow clearance, the area above the generator should be at least 5 ft (1.52 m) with a minimum of 3 ft (0.91 m) at the front and ends of the enclosure. This includes trees, shrubs, and bushes. Vegetation not in compliance with these clearance parameters could obstruct air flow. In addition, exhaust fumes from the generator could inhibit plant growth. See Figure 34 and the installation drawing within the owner's manual for details. Fri am Automatic start-up. Disconnect utility power and render unit Inoperable before working on unit. Failure to do so will result in death or serlous injury. (000191) Asphyxiation. Running engines produce carbon monoxide, a colorless, odorless, poisonous gas. Carbon monoxide, if not avoided, will result in death or serious injury. (000103) NOTE: If the generator is not set to OFF, it can crank and start as soon as the battery cables are connected. If the utility power supply is not turned off, sparking can occur at the battery posts and cause an explosion. Site Preparation Locate the mounting area as close as possible to the transfer switch and fuel supply. • Leave adequate room around the area for service access (check local code), and place high enough to keep rising water from reaching the generator. • Choose an open space that will provide adequate and unobstructed airflow. • Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air intakes (see Site Selection). • Select the type of base, such as —but not limited to --compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. Material Sufficient for Level Installation Prepare a rectangular area approximately 5 in (127 mm) deep (A) and approximately 6 in (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be poured if desired or required. Figure 3-3. Compacted Soil or Gravel Pad NOTE: If a concrete pad is required, follow all applicable federal, state, or local codes. Installation Guidelines For 60 Hz Air -Cooled Generators 13 q-D4 cli Cf� .5L- 0 6' to _ ej fi ri Ij �1 Pi Z� w Optional Load Calculation Heat Larger Than Air —[ SF x 3VA Living Only = L� ! Lib (2) Small appliance ckts @ 1500VA each = 3000 Refrigerator @ 1500 = l Refrigerator @ 1500 �S6 Freezer @ 1500 Washing Machine @ 1500 Dishwasher @ 1500 Disposal @ 1500 _ ...� Mini Sewer @ 1500 Clothes Dryer @ 5000 _ 5� Range @ 12000 Water heater @ 4500 Fixed microwave @ 1500 - / S o0 Vacuum @ 1500 Trash Compactor @ 1500 ._ Pool Heater @ 'name plate' Spa @ 'name plate' Motors 746VA per HP Poo Garage Door Opener w 1) Total = I asss 2) First 10 KVA of general load @ 100% ' 0-0 3) Subtract line 2 from 1 = , ss 4) Multiply line 2: @ 40% 3gj/,2 5) Add lines 2 and 4 = /�a1 L. 2. 6) 60/50amp breaker for heat (10000) 7) 40/30amp, breaker for heat (5000) 8) Total heat- Add lines 6 and 7 = / 0 00 9) Multiply line 8 @ 65% 10) Add lines 5 and 9 11) Divide line 10 by 240 oL� L -(�' (Generator Size Needed) (Breaker Size Needed) t•,:: &, cat ?� . -,� C' i^..1 6. Summary: Line 10 is the total KW Line 11 is the total Amps e, �r' , ST. LUCIE COUNTY BUILDING DIVISION REVI war; FOR Col mA lh,.Nq REVIEWED E3Y DATE PLANS AND PERMIT MUST BE KEPT ON J06 OR NO INSPECTION WILL BE MADE