HomeMy WebLinkAboutGENERATOR APPROVAL• Two Line LCD Multilingual Digital
EvolutionT" Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch,
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED
Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
Ivloaels C-i007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 IcW 60 Hz
``OENERAC�.
• Direct -To -Dirt Composite Mounting Pad
Natural Gas or LP Gas Operation C @US Qv'
5 Year Limited Warranty LISTED
limited circcertification
it switches. uniapplies
s packaged with the Smart Switch are ULkcertf certified
• Capability to be installed within 16" (457 mm) the USA only.
of a building* *Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
FEATURES
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and.reliability for when you need it the most. The
G-Force series engines are purpose built and designed to handle the rigors of
extended run times In high temperatures and extreme operating conditions.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM -MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at t1%.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
✓ PROTOTYPE TESTED ✓ NEMA MG11.22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
✓ SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes Its own transfer
systems and controls for total system compatibility.
G E N E R A C �t�3ss PROMISE. ®
LMinkile '
•Dukf /n fAs f4Sd uf/nD tlomnDcnntllOm(Dn Darta.
GENERAC'
16/20/22 kW
features and benefits
Engine
• Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine
run cooler, reducing oil consumption resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
r , • Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
Generator
• Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
• Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation
Maximizes motor starting capability.
• Automatic voltage regulation
Regulates the output voltage to ±1 % prevents damaging voltage spikes.
• UL 2200 listed
For your safety,
Transfer Switch (if applicable)
• Fully automatic
Transfers your vital electrical loads to the energized source of power.
• NEMA 3R
Can be Installed inside or outside for maximum flexibility.
• Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
EvolutionT" Controls
• Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
• Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
• Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80`Yo pick-up, of standard voltage.
• Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
• Utility Interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
• Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
• Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
• Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
• Main line circuit breaker
Protects generator from overload.
• Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph, Hinged key ,locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing Installation, as close as 18" away from a building.
Installation System _
• 1 It (306 mm) flexible fuel line connector Absorbs any generator vibration hen connected to PP
rigid pipe.
9
• Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life
GENERAC°
16/20/22 kW specifications
Generator
Model
G007035.0,0007036.0, G007038-0,04007039.0
0007042.0,0007043.0
G007037.0 (16 kW)
(20 kW)
(22 kW)
Rated Maximum Conflnuods,Powei Capacity (LP)
16,000 Watts"
20,000 Watts*
22.000
Rated Maximum Continuous Power Capacity (NG)
16,000 Watts*
18,000 Walls*
19,500
Rated Voltage
246
240
240
Rated Maximum Continuous Load Current — 240 Volts (LP/NG)
66.6/66.6
83.3/75
91.6181.3
Total Harmonic Distortion
Less than 5%
Less than 5%
Less than 5%
Main Line Circuit Breaker
70 Amp
100 Amp
100 Amp
Phase
1
1
1
Number of Rotor Poles
2
2
2
Rated AC Frequency
60 Hz
60 Hz
60Hz
Power Factor
1.0
1.0
1.0
Battery Requirement (not included)
12 Volts, Group 26R 540 CCA Minimum or Group 35AGM
650 CCA Minimum
Unit Weight (lb/kg)
406/186
4481203
466/211
DImenslons (L x W x H) in/mm
48 x 25 x 29/1218 x 638 x 732
Sound output in dB(A) at 23 ft,(7 m) with generator operating at normal load' •
66
66
67
Sound output In dB(A) ah23ift;(7 m) with generator in Quiet -Test' low -speed exercise mode**
58
58
58
Exercise duration
5 min
5 min
5 min
Engine
Type of Engine
GENERAC G-Force 1000 Series
Number of Cylinders 1
2
2
2
Displacement
999 cc
999 cc
999 cc
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve
Overhead Valve
Overhead Valve
Ignition System
Solid-state w/ Magneto
Solid-state w/ Magneto
Solid -slate w/ Magneto
Governor System
Electronic
Electronic
Electronic
Compression Ratio
9.5:1
9.51
9.5:1
Starter
12 Vdc
12 Vdc
12 Vdc
Oil Capacity Including Filler
Approx.1.9 g1/1.8 L
Approx.1.9 gV1.8 L
Approx. i:9 gl/1.8 L
Operating rpm
3,600
3,600
3,600
Fuel Consumption
Natural Gas ` . 0a/hr (ma/hr)
1/2 Load
218 (6.17)
204 (5.78)
.216 (6.12)
Full Load
309 (8.75)
301 (8.52)
310 (8.78)
Liquid Propane ! i 113/6r (gal/hr) [1/hr]
1/2 Load
91,6.(2,52) [9.53]
86 (2.37) [8.99]
93.2 (2.56) [9.70]
Full Load
106.8 (2.94) [11.11 ]
129.6 (3.56) [13.48]
140 (3.87). [14.65]
Note: Fuel pipe must be sized for full load, Required fuel pressure to generator fuel Inlet at all load ranges - 3.5-71 water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury)
for LP gas. For Btu content, multiply ft3/hrx 2500 (LP) or 011r x 1000 (NG). For Megaloule content, multiply ma/hr x 93.15 (LP) or m3/hr x 37.26 ING)
Controls
2-Line Plain Text Multilingual LCD Display
Simple user interface for ease of operation.
Mode Bultons:Auto (
Automatic Start on Utility failure, 7 day exerciser.
Manual
Start with starter control, unit stays on. If utility fails, transfer
to load takes place.
Off i I
Stops unit. Power is removed. Control and charger still operate.
Ready to Run/Maintenance Messages
Standard
Engine Rum Hours Indicatlon` j ,
Standard
Programmable start delay between 2-1500 seconds
Standard (programmable by dealer only)
Utility Voltage Loss/Relum 16.U(illty Adjustable (Brownout: Selling)
From 140-171 W19D-216 V
Future Set Capable Exeroiser/Exercise Set Error Warning
Standard
Run/AIamVMalntenance Logs I ?
50 Events Each
Engine Start Sequence
Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration).
Starter Lock -out
Starter cannot re-engage until 5 sec after engine has slopped.
Smart Battery Charger
Standard
Charger FaulVMiss)ng AC Warning I
Standard
Low Battery/Battery Problem Protection and Battery Condition Indication
Standard
Automatic Voltage Regulatlori v;W,Over and Under Voltage Protection
Standard
Under-Frequency/Overload/Slepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Pro(eclibn
Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
Overcrank/Overspeed ((p 721Hz)/rpin Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal FaulUlncorrerdWiring Protection
Standard
Common External Fault Capability.
Standard
Field Upgradable Firmware 1 ' ' ;
Standard
'Bound levels are taken from 6reftonlol the generator. Sound levels Wain from other sides at the generator maybe higher depending on Installation parameters. Dating del'milions-Standby. Applicable for supplying emergency power for the duration
of the utinlypower outage. Nooverload capab0rtyisavailable for thlsranq (All ratings InacvordancoMthB55514,IS03046andDIN6271).'Maximum111ovoltampsandcurrentaresubjecttoandlimitedbysuchladorsasfuelBluhnegajoule
content ambienttemperature, altitude, engine powerand condition, etc. Madmum power deaeasesabout 3.5 percenlfor each 1,000 feet (304.8 meters) above sea level; and alsDwill decrease aboutl percent for each6 `C (10 `F) above 16 *0 (60 9
i
GENERACO
16/20/22 kW I switch options
Limited Circuits Switch Features
Is 16 circuits, breakers not included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
• 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive install.
Dimensions
Height
Width
peplh
H1
H2
Wi
W2
In
26.75
30,1
10.5
13.5
6.91
mm
679.4
764:3
266.7
343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
2/0-#14
210-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resis-
tive.
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
Ing flexibility.
Dimensions
200 Amps 120/240, to
Open Transition Service Rated
Height
HI
H2
Width
W1 W2
Depth
In
26.75
30.1
10.5
13.5
6.91
mm
679.4
7e4.3
266.7
343.0
175.4
Model
G007036.0 (16kW)
No: of Pales
2
Current Rating (Amps)
100
Voltage Rating (VAC)
120/240, iH
Utility Voltage Monitor (Fixed)'
-Pick-up
80%
-Dropout
65%
Return to Utility*
approx.15 sec
Exercises bi-weekly for 5 minutes*t
Standard
UL Listed
Standard
Total Circuits Available
16
Tandem Breaker Capabilities
8 spaces
Circuit Breaker Protected
Available RMS Symmetrical
10,000
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
Dern�
Model G007037.0 (16 kM/G007039.0 (20 kW)/
G007043.0 (22 kW)
No. of Poles
2
Current Rating (Amps)
200
Voltage Rating (VAC)
120/240. iG
utility Voltage Monitor (Fixed)*
-Pick-up
80%
-Dropout
65%
Return to utility*
approx.13 sec
Exercises bi-weekly for 5 minutes*
Standard
UL Listed
Standard
Enclosure Type
NEMA/UL 3R
Circuit Breaker Protected
22,000
Lug Range
250 MCM - #6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
DEPIM
CENERAG
16/20/22 kW
specifications
Generator
Model
0007035.0, G007036.0, 6007038-0, 0007039.0 G007042.0, G007043.0
Rated Maximum Continuous Power Capacity (LP)
G007037-0 (16 kW) (20 kW) (22 kW)
16,000 Watts" 20,000 Walls' 22,000
Rated Maximum Continuous Power Capacity (NG)
16,000 Watts" 18,000 Walls" 19.500
Rated Voltage 1
240 240 240
Rated Maximum Continuous Load Curren — 240 Volts (LP/NG)
66.6/66.6 BUM 91.6/81.3
Total Harmonic Distortion
Less than 5% Less than 5% Less than 5%
Main Line Circuit Breaker
70 Amp 100 Amp 100 Amp
Phase
1 1 1
Number of Rotor Poles
2 2 2
Rated AC Frequency i
60 Hz 60 Hz 60Hz
Power factor
10 1.0 1.0
Battery Requirement (not included)
12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum
Unit Weight (lb/kg)
406/186 448/203 466/211
Dimensions (L x W x H) iNmm
48 x 25 x 29/1218 x 638 x 732
Sound output in dB(A) at 23 (f (7 m) with generator operating at normal load"
66 66 67
Sound output in dB(A) at '23;f1',(7 m) with generator in Quiet -Test l" low -speed exercise mode"
58 58 58
Exercise duration
5 min 5 min 5 min
Engine
Type of Engine
GENERAC G-Farce 1000 Series
Number of Cylinders 1
2 2 2
Displacement
999 cc 999 cc 999 cc
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve Overhead Valve Overhead Valve
Ignition System
Solid-state w/ Magneto Solid -stale w/ Magneto Solid -stale w/ Magneto
Governor System
Electronic Electronic Electronic
Compression Ratio
9.5:1 9.5:1 9.5:1
Staffer
12 Vdc 12 Vdc 12 Vdc
011 Capacity Including Filter. I
Approx 1.9 gU1.8 L Approx 1.9 gt/1.8 L Approx. 1.9 g111.8 L
Operating rpm
3,600 3,600 3,600
Fuel Consumption
Natural Gas i ft3/hr (m3/hr)
1/2 Load
218 (6.17) 204 (5.78) 216 (6.12)
Full Load
Liquid Propane 1`13/hr (gal/hr) [I/hhr]
309 (8.75) 301 (8.52) • 310 (8.78)
1/2 Load
91.6 (2.52) [9.53] 86 (2.37) [8.99] 93.2 (2.56) [9.70]
Full Load
106.8 (2.94) [11.11] 129.6 (3.56) [13.48] 140 (3,87) [14.65]
Note: Fuel pipe must he sized for full load. Required fuel pressure to generator fuel Inlet at all load ranges - 3.5-71 water column (7-13 mm mercury) for natural gas,10-12' water column (19-22 mm mercury)
for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or 03/hr x 1000 (NG). For Megaloule content, multiply m3/hr x 93.15 (LP) or ma/hr x 37.26 ING)
Controls
2-Line Plain Text Multilingual LCD Display
Simple user interface for ease of operation.
Mode Bullons;Aulo I i
Automatic Stan on Utility failure. 7 day exerciser.
Manual
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Off ! i
Stops unit. Power Is, removed, Control and charger still operate.
Ready to Run/Maintenance Messages
Standard
Engine Run Hours Indication'
Standard
Programmable start delay between 2-1500 seconds
Standard (programmable by dealer only)
Utility Voltage Loss/Return to UIIII,Iy,Adjustable (Brownout Selling)
From 140-171 W19D-216 V
Future Set Capable Fxerciser/Exerclse Set Error Warning
Standard
RurVAlarm/Maintenance LoO ' !
50 Events Each
Engine Start Sequence
Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration).
Starter Look -out i ; !
Starter cannot re-engage until 5 sec after engine has slopped.
Smart Battery Charger
Charger Fauil/Missing AC Warning
Standard
Low Ballery/Baltery Problem Protection and Battery Condition Indication
Standard
Standard
Automatic Voltage Regulalion with Over and Under Voltage Protection
Standard
Under-Frequency/Overload/S(epper Overcurrenl Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
OvercranWOverspeed (@ 72;Hz)/rpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal FaultAncorrect Wiring Pr'olec, tion
Standard
Common External Fault Capability
o-° �"-�'I'r''
Standard
Field Upgradable Firmware i 1,
Standard
"Sound levelsare taken from the frontol the generator. Sound levels taken from other sidesol the generator may be higher depending on Installation parameters. Rating definitions -Standby: Applicablefor supplying emwgemypower for the duration
of thAlity power outage. No overload capabllity Is available for this rating. (All ratings In accordanco wllh BS5514, IS03046 and DIN6271). ' Ma rnum Nlovoltamps and current are subject to and limited by sueh factors as fuel Bbdmegaloule
canten amblenttemperaMe,altiNde,enginepovnuandCondition,etc. Maximum
power decreasesabout3.5peicentrar each 1.000ioet(304.8
i
matefs) above sea level; and also will decfeamabout I percent for each 6 T (10,F) above 1 61C (60 'F).
b v
e
GENERAL'
L'1'•
16/20/22 kw switch Options
Limited Circuits Switch Features
• 16 circuits, breakers not Included.
• Electrically operated, mechanically -held contacts for fast, positive
connections
• Rated for all classes of load,100% equipment rated, both inductive and
resistive.
0 2 pole, 250 VAC contactors.
• 30 millisecond transfer time.
• Dual coil design.
• Rated for both copper and aluminum conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Multi listed for use with 1° standard, tandem, GFCI and AFCI breakers from
Siemens, Murray, Eaton and Square D for the most flexible and cost effec-
tive Install.
Dimensions
Height
Width
Depth
Hi
H2
Wt
W2
In
26.75
30.1
10.5
13.5
6.91
mm
679.4
764':3
266.7
343.0
175.4
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
1/0-#14
2/0-#14
2/0-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
• Intelligently manages up to four air conditioner loads with no additional
hardware.
• Up to four more large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both Inductive and resis-
tive.
• 2 pole, 250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount-
ing flexibility.
Dimensions
200 Amps 120/240, is
Open Transition Service Rated
Height
Width
Depth
H1
H2
Wt '
W2
In
.26.75
30.1
10.5
13.5
6.91
mm
179.4
704.3
266.7
343.0
1 175.4
Model
G007036.0 (IQW)
No. of Poles
2
Current Rating (Amps)
100
Voltage Rating (VAC)
120/240,10
Utility Voltage Monitor (Fixed)`
-Pickup
80%
-Dropout
65%
Return to Utility*
approx.15 seo
Exercises bl-weekly for 5 minutes*t
Standard
UL Listed
Standard
Total Circuits Available
16
Tandem Breaker Capabilities
8 spaces
Circuit Breaker Protected
Available RMS Symmetrical
10,000
Fault Current @ 250 Volts
*Function of Evolution Controller
Exercise can be set to weekly or monthly
DEPTH
Model 0007037-0 (16 kW4/G007039-0 (20 kW)/
6007043.0 (22 kW)
No. of Poles
2
Current Rating (Amps)
200
Voltage Rating (VAC)
120/240.10
UIIIttyVoltage Monitor (Fixed)*
-Pick-up
80%
-Dropout
65%
Return to Utility*
approx,13 sec
Exercises bi-weekly for 5 minutes*
Standard
UL Listed
Standard
Enclosure Type
NEMA/UL 3R
Circuit Breaker Protected
22,000
Lug Range
250 MCM - #6
*Function of Evolution Controller
Exercise can be set to weekly or monthly
DEPTH
1 6/20/22 IcW
GENERAC
available accessories
Model #! ;Product
Description
Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac-
G006463-4 Mobile LinkTM
cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or
text message when a change In the generators status occurs. Available in the U.S. only.
G005819-0 26R Wet Cell Battery
Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet
battery
cell for use with all air-cooled standby product (excluding PowerPact®).
G007101.0 Battery Pad Warmer
The pad warmer rests under the battery. Recommended for use if the temperature regularlyfalls below 0°F.
(Not necessary for use with AGM -style batteries),
G007102-0 Oil Warmer
Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below
0°F.
G007103-0 'Breather Warmer
The breather warmer is for use in •extreme cold weather applications. For use with Evolution controllers
only In climates where heavy Icing occurs.
G005621-0 Auxiliary Transfer Switch
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
Contact Kit
you may not need. Not compatible with 50 amp pre -wired switches.
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a
0007027-0 - Bisque (Standard on 22 kW)
sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting
holes located in the base.
If the generator enclosure Is scratched'or damaged, it is important to touch-up the paint to protect from
G005703-0 - Bisque . Paint Kit
future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator
enclosure.
G006485-0 Scheduled Maintenance Kit
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine
maintenance on a Generac automatic standby generator.
G006873-0
Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase Its
(50 Amps)
power management capabilities. ltprovides additional power management flexibility notfound in any other
power management system.
dimensions & PCs
Dimensions shown are approximate. Refer to installation manual for exact dimensions, 00 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
LEFT BIDE VIEW
tea9 tro
FRONTVIM
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
13007037-0
696471070378
0007038-0
695471070385
G007039-0
69647107.0392
G007042-0
696471070422
G007043-0
696471070439
GENE RAC" Generac Power Systems, Inc. o 545 W29290 HWY. 69, Waukesha, WI 53189 - generac.com
02016 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change wilhout notice. Part No. 10000000194-0 10124/16
amart management
Modules (SMM)
GENERAL'
GENERAC® ACCESSORIES
Model G006873.0
0@"S
LISTED
DESCRIPTION;
Generac's Smart Power Management System is designed to optimize the performance of a standby generator. The system can consist of up to 8 individual
Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self -
Frequency and operate autonomously.
Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or
generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if It falls below a certain
threshold, the module will automatically follow a power management algorithm to ensure that the generator is not overloaded.
The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run In an outage, therefore
reducing the necessary size of the generator for a more cost effective solution.
SMM SPECIFICATIONS
Power Supply Source ......................................
SupportedVoltages....................................................................................................................................................................................................
Contactor Coll Voltage
240 VAC (from L(24 input)
.............
Coll VA Inrush,
240 VAC
......
CollVA Sealed.,.....,..,.i...................................................................................................................................................................................................................................240
VAC
Poles
30
ResistiveAmps........................................................................................................................................................................................................................................................
6.5
FILInductive Amps
. 2
...............................................................................................................................................................................................................................................
LockedRotor Amps...................................................................................................................................................................................................................................................50
40
Enclosure Rating.......................................................................................................... ..
2409240V
........................... . Yes
yR=c........................................................................................................NEMA3R
GENERACe
GENERAC®
Smart Management Modules (SMM) Dimensions and UPC
h � 1
Model
GOOBB73.0
Height (iNmm)
H1
H2
6.17/156.8
2.36/60
Width (iNmm)
W1
7.06/179.4
W2
4.72/120
Depth (iNmm)
3.7/94
Weight (lbs/kilos)
2.06/0.94
Shipping Weight (lbs/kilos)
2.44/1.11
UPC Code
696471068733
SMM Controls (located behind the cover of the module)
I
LED ON - LOAD CONNECTED
LED FLASH 1S - LOAD SHED
LOCKOUT
PRIORITY LOAD ON
LED FLASH 3S = 30 MIN LOCKOUT
GENERATOR
LED FLASH IS = GEN LOAD LOCKOUT
A
3 7 �--
LED OFF = NO MODULE POWER
® ®
-~
0
0
° LOCKOUT
I
TEST
DISABLED
Priority Dial (A) —
Sets module priority,
Lockout Switch (B) —
Prevents load from operating when system Is operating under generator power.
Test Button (C) —
Disables contactor output for a specified time.
LED (D) —
Provides module status with easy viewing through the external viewing window
located in the upper right corner of the module.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 o generac.com
GENERACD
020116 Generac Power Systems, Inc. All rights reserved. Au specifications are SUNNI 10 change wlhoul notice. Bulletin OL1500-C 03/10/16
r
—site Selection and Preparation
Section 3: Site Selection and Preparation
Site Selection
Oi 5ft(1.52m) C 5ft(1.52m)
3ft
B ~(03 ft
.91 m)� O �(0 91 m)
3ft (0.91 m) OO
b B F
Nall.
LCI
Figure 3-1. Installation Clearances
ID
Description
Comments
A
Top of generator
—
B
Front and end clearance
Minimum clear distances cannot Include shrubs, bushes, or trees.
C
Rear clearance
18 In (45.7 cm) minimum clearance per NFPAtesting, labeling, and listing, unless state or local codes
dictate otherwise.
D
Windows and openings
No operable windows, doors, or openings in the wall are permitted within 5 ft (1.52 m) from any point of
the generator.
E
Existing wall
One -hour fire rated walls allow closer placement of the generator set. Confirm before Installation.
F
Removable fence
Removable fence panels for servicing cannot be placed less than 3 ft (0.91 m) In front of the generator.
G
Overhead clearance
5 ft (1.52 m) minimum distance from any structure, overhang, or projections from the wall.
DO NOT Install under wooden decks or structures unless this distance is maintained.
Installation Guidelines For 60 Hz Air -Cooled Generators 11
Site Selection and Preparation 4
Install the
generator set, in its protective enclosure,
outdoors where adequate cooling and ventilating air is
always available (Figure 3.1). Consider these factors:
° The installation of the generator must comply
strictly with ICC IFGC, NFPA 37, NFPA 54, NFPA
58, and NFPA 70 standards.
• Install the unit where air inlet and outlet openings
will not become obstructed by leaves, grass, snow,
etc. If prevailing winds will cause blowing or
drifting, consider using a windbreak to protect the
unit.
• Install the generator on high ground where water
levels will not rise and endanger it. This unit should
not operate in or be subjected to standing water.
• Allow sufficient room on all sides of the generator
for maintenance and servicing. This unit must be
installed in accordance with any local, state, or
national codes for minimum distances from other
structures.
Clearance from the ends and front of the generator
must be 3 ft (0.91 m). This includes shrubs,
bushes, and trees. Clearance from the back of the
generator must be a minimum of 18 in (457 mm).
Clearance at the top should be a minimum of 5 ft
(1.52 m) from any structure, overhang, or
projections from the wall.
DO NOT install under wooden decks or structures
unless there is at least 5 ft (1.52 m) of clearance
above the generator.
Install the unit where rain gutter down spouts, roof
run-off, landscape irrigation, water sprinklers, or
sump pump discharge does not flood the unit or
spray the enclosure, including any air inlet or outlet
openings.
° Install the unit where services will not be affected
or obstructed, including concealed, underground,
or covered services such as electrical, fuel, phone,
air conditioning, or irrigation. This could affect
warranty coverage.
° Where strong prevailing winds blow from one
direction, face the generator air inlet openings to
the prevailing winds.
• Install the generator as close as possible to the fuel
supply to reduce the length 'of piping. REMEMBER
THAT LAWS OR CODES MAY REGULATE THE
DISTANCE AND LOCATION. In the absence of
local codes regarding placement or clearance, we
recommend following these guidelines:
— Install the generator as close as possible to the
transfer switch. REMEMBER THAT LAWS OR
CODES MAY REGULATE THE DISTANCE AND
LOCATION.
— The generator must be installed on a level sur-
face. The generator must be level within a 0.5 in
(13 mm) all around.
— The generator is typically placed on pea gravel,
compacted soil, crushed stone, or a concrete
pad. Check local codes to see what type is
required. If a concrete pad is required, all appli-
cable codes should be followed.
Installation Guidelines for Stationary Air -Cooled
Generators
NFPA 37 is the The National Fire Protection
Association's standard for the installation and use of
stationary combustion engines. Its requirements limit the
spacing of an enclosed generator set from a structure or
wall (Figure 3-1).
NFPA 37, Section 4.1.4, Engines Located Outdoors:
Engines, and their weatherproof housings if provided,
that are installed outdoors shall be located at least 5 ft
(1.52 m) from openings in walls and at least 5 ft (1.52 m)
from structures having combustible walls. A minimum
separation shall not be required where the following
conditions exist:
1. The adjacent wall of the structure has a fire
resistance rating of at least one hour.
2. The weatherproof enclosure is constructed of
noncombustible materials and it has been
demonstrated that a fire within the enclosure will
not ignite combustible materials outside the
enclosure.
Annex A — Explanatory Material
A4.1.4 (2) Means of demonstrating compliance are by
means of full scale fire test or by calculation procedures.
Because of the limited spaces that are frequently
available for installation, it has become apparent that
exception (2) would be beneficial for many residential
and commercial installations. With that in mind, the
manufacturer contracted with an independent testing
laboratory to run full scale fire tests to assure that the
enclosure will not ignite combustible materials outside
the enclosure.
NOTE: Southwest Research Institute testing approves
18 in (457 mm) installation minimum from structure
(Figure 3-1, C). Southwest Research Institute is a
nationally recognized third party testing and listing
agency.
The criteria was to determine the worst case fire scenario
within the generator and to determine the ignitability of
tems outside the engine enclosure at various distances.
The enclosure is constructed of non-combustible
materials, and the results and conclusions from the
ndepen'dent testing lab indicated that any fire within the
12
Installation Guidelines For 60 Hz Air -Cooled Generators
Site Selection and Preparation
generator enclosure would not pose any ignition risk to
nearby combustibles or structures, with or without fire
service personnel response.
® Sidi ® W OXH."
�GMIflS of ectiton 4N A 37
LISTED Ely.Soutlnrast Research
h�mhft Ilan AM E Tens
ND1E 13D CHAR MAC
NOTE 2 too CHAR MA?O•�
-�- NOTE 3 130 CHAR. K4MX n
NOTE 4 r30 CHAR MAI4
NOTE 6 rM CHAR MA.o
® NOTE 8 130 CHAR MAXI
NOTE 7 (30 CHAR LIAR
013we Pam srsTEMs. we
�YilAUOWk TIl USA 5M OL2157
Figure 3-2. Southwest Research Institute Marring
htip:lM+ww.swrl. orgl4org/dO1Mrellistiab/7istprodldirector htm
Based on this testing and the requirements of NFPA 37,
Sec 4.1.4, the guidelines for installation of the generators
listed above are changed to 18 in (457 mm) from the
back side of the generator to a stationary wall or building
(C). For adequate maintenance and airflow clearance,
the area above the generator should be at least 5 ft (1.52
m) with a minimum of 3 ft (0.91 m) at the front and ends
of the enclosure. This includes trees, shrubs, and
bushes. Vegetation not in compliance with these
clearance parameters could obstruct air flow. In addition,
exhaust fumes from the generator could inhibit plant
growth. See Figure 3-1 and the installation drawing
within the owner's manual for details.
Automatic start-up. Disconnect utility power and
render unit inoperable before working on unit.
Failure to do so will result in death or serious Injury.
(000191)
Asphyxiation. Running engines produce
carbon monoxide, a colorless, odorless,
poisonous gas. Carbon monoxide, if not
avoided, will result In death or serious injury.
(000103)
NOTE. If the generator is not set to OFF, it can crank and
start as soon as the battery cables are connected. If the
utility power supply is not turned off, sparking can occur
at the battery posts and cause an explosion.
Site Preparation
Locate the mounting area as close as possible to
the transfer switch and fuel supply.
Leave adequate room around the area for service
access (check local code), and place high enough
to keep rising water from reaching the generator.
Choose an open space that will provide adequate
and unobstructed airflow.
Place the unit so air vents won't become clogged
with leaves, grass, snow, or debris. Verify that
exhaust fumes will not enter any building through
eaves, windows, ventilation fans, or other air
intakes (see Site Selection).
Select the type of base, such as —but not limited
to —compacted soil, gravel, or concrete, as desired
or as required by local laws or codes. Verify your
local requirements before selecting.
Material Sufficient for Level Installation
Prepare a rectangular area approximately 5 in (127
mm) deep (A) and approximately 6 in (152 mm)
longer and wider (B) than the footprint of the
generator. Verify that the surface where the
generator will be mounted is compacted, leveled,
and will not erode over time. A concrete pad can be
poured if desired or required.
o: l
Figure 3-3. Compacted Soil or Gravel Pad
NOTE: If a concrete pad is required, follow all applicable
federal, state, or local codes.
iotanauuu vuwuwmimi rurOu rzHlr-umieo venerators 13
Optional Load Calculation
Heat Larger Than Air
a9 ` - SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 1500
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
Vacuum @ 1500
Trash Compactor @ 1500
Pool Heater @ 'name plate'
Spa @'name plate'
Motors 746VA per HP PL-61 �"�'-►� �
Garage Door Opener
1) Total
2) First 10 KVA of general load @ 100%
3) Subtract line 2 from 1
4) Multiply line 2 @ 40%
5) Add lines 2 and 4
6) 60/50amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000)
8) Total heat- Add lines 6 and 7
9) Multiply line 8 @ 65%
10) Add lines 5 and 9
11) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
= 3000
(Generator Size Needed)
(Breaker Size Needed)
F�
K*
8T. I.UCIE CBUN't't
l3UILDIN� 01,41131A1,
1101, ,01A
REVIEWED BY
DATE Ng AND PON MIT OR
MU9 BE KEPT JBE MADE
NO INSPEC?ION WILL BE
S EEC = �e�'Vi C�, l�r,���.•c� �4.�e�
v A, 2-156A,
�1e of SF.Z,
0 PIOA-0
i r.s .
Ig- 2 7-5-
s Y,w
31,1 "- 5 #/o
ar
1Lf
4
i#�