Loading...
HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVALAPPLICATION #:AP1285275 STATE OF FLORIDA �+A PERMIT #:56-SF-1754038 DEPARTMNT OF HEALTH SCANNED DOCUMENT # : FI 1131952 ONSITE SEWAGE TREATMENT AND DISPOSAL SYST1 CONSTRUCTION INSPECTION AND FINAL 11 RLCff&F (,OUNTYDATE PAID:08/15/2017 176 (o ova FEE PAID :65.00 RECEIPT #:56-PID-3321857 APPLICANT: Richard & Lesley Wilder AGENT: Richard Wilder PROPERTY ADDRESS: 8200 Germany Canal Rd Port Saint Lucie, FL 34987 LOT: BLOCK: SUBDIVISION: ID#: 3229-233-0002-000-2 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS I ] 1011• TANK SIZE [11 1090.00 I2] I ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polyethylene [ ] - [281 DITCHES FT [ ] 1031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 84 FT [ ] [04] MULTI -CHAMBERED [ LLP N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT I ] 1061 LEGEND 1, 70-143-11DC4 .2. [ ] [32] POTABLE WATER 10 FT [ ] [071 WATERTIGHT [ ] 1331 BUILDING FOUNDATIONS 7 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 100+ FT [ ] [091 DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 262 [2] SQFT [ ] [361 DRAINFIELD COVER [ ] 1111 DISTRIBUTION BOX HEADER X I ] I373 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 3.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 09/01/2017 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] (16] ELEVATION I ABOVE / BELOW ]BM 11.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] -[41] STORMWATER RUNOFF [ ] 1181 DOSING PUMPS [ ] [421 ALARMS [ ] 1191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT I ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR Jamie DiFrancesco (AIL Contr [ ] [481 OTHER INFILTRATOR Quick4 EQ36 (single c [ ] [231 FILL TEXTURE [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] 1251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED / /�/ /✓�— St. Lucie CHD DATE: 08/14/2017 DISAPPROVED ] ' Envir nmental Specialist IIV, J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM I APPROVED / DISAPPROVED ]: � St. Lucie CHD DATE: 09/01/2017 Environmental Specialist 11 Brh J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) � DH 4016, 08/09 (Obsoletes all previous editions which may not be used) RECEIVED SEP42 7 Incorporated: 64E-6.003, FAC a 2 of 3 EH Database v 1.0.1 AP1285275 EID1754036 APPLICATION #:AP1285275 STATE OF FLORIDA PERMIT #: 56-SF-1 754038 DEPARTMENT OF HEALTH DOCUMENT #:F11131952 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:08/15/2017 FEE PAID:65.00 K N:�:Yi1rT {f : V V—I a V wwL I W W I Violation'Number Comment ats The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 200 gpd• System failed inspection due to elevation and size of drainfield. Violation letter emailed to contractor. System reinspected 8/15/17. Violations corrected. No other violations, owner notified ok to cover. Needs final inspection for mound system and grading. Final system approved. Contractor and building department emailed final approval. DE 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1285275 EID1754038 Page 2 of 3