Loading...
HomeMy WebLinkAboutPRODUCT REVIEWModels: 20RESC KOHLER. Power, Systems- LPG/Natural Multi -Fuel 09001 Standard Features • RDC2 Controller NATIONALLY REGISTERED - b One digital controller manages both the generator set and Aft"liECTURA'L RCCDRD , transfer switch functions (with optional Model RXT). ' L ' o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying demand. The Kohler® Advantage • High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra -low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. • Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with a premium 5-year or 2000 hour limited warranty. • Powerful Performance Exclusive Powerboost- technology provides excellent starting power. • Corrosion -Proof Enclosure The bold new Kohler design is completely corrosion proof, even in harsh seaside environments, and is impact - resistant even at -34° C (-30' F). • Fast Response Kohler generators restore power to your home quickly and reliably. o Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality... • Kohler Command PRO Engine Features o Kohler Command PROD OHV engine with hydraulic valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. o Powerful, reliable air-cooled performance. o Simple field conversion between natural gas and LPG fuels while maintaining emission certification. • Designed for Easy Installation o Polymer base eliminates the need for a concrete mounting pad, reducing installation time and cost. o Fuel and electrical connections through the enclosure wall eliminate the need for stub -ups through the bottom. o Load connection terminal block allows easy field wiring. o Designed for outdoor installation only. • Certifications o Meets emission regulations for U.S. Environmental Protection Agency (EPA) with both natural gas and LPG. Note: CARB does not regulate emergency standby generators with outputs less than 50 HP. o UL 2200/cUL listed (60 Hz model). o CSA certification available (60 Hz model). o GOST certified (Russia). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters • Approved for stationary standby applications in locations served by a reliable utility source. • Warranty o 5-year/2000 hour limited warranty for on -grid (standby) applications in locations served by a reliable utility source. - a e ST, LUCIE COUNTY BUILDING DIVISION REVIEWED FOR C PLI REVIEWEQ BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE G4-246 (20RESC) 10115a Ratings Alternator Voltage- Phase Hz.. 120 * 1 60 110/220 1 60 120/240 * 1 60 100/200 1 50 21`7 ,: 115/230 1 ; 50 220t 1 50 230 1 50 240# 1 50 2137 120/208 110/220 127/220 120/240 220/380 277/480 100/200 220/380$ 230/400 240/416$ 3 3 3 3 3 3 3 3 3 3 60 60 60 60 60 60 50 50 50 I �50 Standby Ratings Line Circuit iLturai Gas LPG Breaker kW/I�VA Amps. kW/kVA Amps Amps Poles 18/18 150 20/20 166 -�175 ' .1 18'18 . _ 81 20/20' 90 ;100 i 2 1 q/.18 75 - .. 20/20.-. 83 : , . - . 100 ... __2 15/15 :. •;; , 75 16/16 • , .,• - 80 :- :, .- 80 • •, 2 , , , 1/5/15 65 1 6/1 6 69 „ 100 .-2; 15/15 68 16/16 72 80 ' 1 115/.15 65 16/16 69 80 2 / 15/15 62 16/16 66 80 1 17/21 58 17/21 58 70 3 17/21 55 17/21 55 80 3 17/21 55 17/21 55 80 4 17/21 51 17/21 51 60 3 17/21 32 17/21 32 40 4 17121 26 17/21 26 30 3 14/,17 50 15/18 54 63 3 14/17 26 15/18 28 32• 4 14/17 25 15/18 27 32 4 14/17 24 15/18 26 32 4 * UL listed. 1' 50 Hz single-phase models are factory -connected as 230 volts.' Feld -adjustable to 220 or 240 volts by an authorized service technician. $ 50 Hz 3-phase models are factory -connected as 230/400.vofts. Feld -adjustable to 220/380 or 240/416 volts by an authorized service technician. Note: The line circuit breaker is automatically s;lected based on the generator set model and voltage.configuration. _ RATINGS: Standby ratings apply to installations served by a reliable utill source. All three-phase units are rated at 0.e power factor. All single-phase units are rated at 1.0 power factor. The standby rating isapplicabletovariableloadswithanaverageloadfactorof80%fortheduretionofthepoweroutage. NoovedoadcapacityisspeafiedetthisreUng. Ratings are in accordance withlSO-3046/1, BS5514, AS2789, and DIN 6271. GENERAL GUIDELINES FOR DER&NG: ALTITUDE: Derate 4%per 305 m (1000ft) elevation above 163 m (500 %). TEMPERATURE: Derate 2% per 5.5"C (10-F) temperature increase above 16-C(60°F). Availability is subject t6change without notice. The generatorset manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local hler Co. generator distributor for availability. G4-246 (20RESC) 10/15a Alternator Specifications Alternator Specifications Alternator Features . Specifications' ' Alternator • Compliance with NEMA, IEEE, and ANSI standards for Manufacturer Kohler . . temperature rise. Type 2-Pole, Rotating Field . Self -ventilated and dripproof construction. Leads, quantity 2F7 4 4 • Windings are vacuum -impregnated with epoxy varnish for dependability and long life. 2G7 Voltage regulator Digital • Superior voltage waveform and minimum harmonic distortion from skewed alternator construction. Insulation: NEMA MG1-1.66 Material Class H e Digital voltage regulator with ±1.0% no-load to full -load RMS regulation. Temperature rise 130°C Standby Bearing: quantity, type 1, Sealed a Rotating -field alternator with static exciter for excellent Coupling Direct load response. , Amortisseur windings Full • Total harmonic distortion (THD) from no load to full load with Voltage regulation, no-load to full -load a linear load is less than 5%. RMS ± 1.0% One-step load acceptance 100% of Rating Peak motor starting kVA: (35% dip for voltages below) 240 V, 1 ph 2F7 (4 lead) 41 (60 Hz) 230 V, 1 ph 2F7 (4 lead) 28.(50 Hz) ' 240 or 480 V, 3 ph 2G7 (12 lead) 69 (60 Hz) 208 or 416 V, 3 ph 2G7 (12 lead) ' 55 (50 Hz)• • G4-246 (20REsc) 10/15a Applic Engine Engine Specifications Manufacturer Kohler Engine: model, type CH1000 4-Cycle Cylinder arrangement V 2 Displacement, cm3 (cu. in.) 999•(61)• Bore and stroke, mm (in.). 90 x 78.5 (3.54 x 3.1) Compression ratio Main bearings: quantity, type 2, Parent Material Rated RPM 60 Hz 3600 50 Hz 3000 Max, engine power at rated rpm, kW (HP) LPG, 60 Hz 23.0 (30.9)' ' LPG, 50 Hz - 20.0 (26.8) Natural gas, 60 Hz 20.2 (27.1) Natural gas, 50 Hz 16.8 (22.5) Cylinder head material Aluminum Valve material Steel/Stellite® Piston type and material Aluminum �loy Crankshaft material Heat Treated, Ductile Iron Governor: type Electronic Frequency regulation, no load to full load Isochro9ous Frequency regulation, steady state s0.5% Dr� Air cleaner type Engine Electrical 1 Engine Electrical System Ignition system Ele0onic, Capacitive Discharge Starter motor rated voltage (DC) Battery (purchased separately): I12 Ground Negative Volts (DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA) rating for -18°C (0°F) 500 Group size 51 Exhaust Exhaust System Exhaust temperature exiting the enclosure at rated kW, dry, °C (°F) 260 (500) Lubrication Lubricating System Type Full Pressure Oil capacity (with filter), L (qt.) 1.9 (2.0) Oil filter: quantity, type 1, Cartridge Oil cooler Integral tion Data Fuel :Pipe Size Minimum Gas Pipe Size Recommendation; In. NPT - Natural Gas' LP.G- - Pipe Length, 281,000 340,000 m (ft.) . Btu/hr. Btu/hr.. 8 (25) 1 3/4 15 (50) 1 1 - 30 (100) 1 1/4 1 46 (150) 1 1/4 1 1/4 61 (200) 1 1/4 1 1/4 ' Fuel Requirements Fuel System Fuel types Natural as or LPG Fuel supply inlet 1/2 NPT Fuel supply pressure, kPa (in. H20): Natural gas 0.9-2.7 (3.5-11) LP 1.7-2.7 (7-11) Fuel Composition Limits * Nat. Gas LPG Methane, % by volume (minimum) 90 min. - Ethane, % by volume (maximum) 4.0 max. - Propane, % by volume 1.0 max. 85 min. Propene, % by volume (maximum), 0.1 max. 5.0 max. C4 and higher, % by volume 0.3 max. 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heating value, MJ/m3 (Btu/fO), (minimum) 33.2 (890) - 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Operation Requirements Fuel Consumption Fuel Fuel Consumption, m3/hr. (cfh) Model Type % Load 60 Hz 50 Hz 100 8.0 (281) 6.4 (225) 75 6.9 (243) 5.4 (189) Natural 50 4.6 (161) 3.9 (139) Gas 25 3.6 (127) 2.9 (103) Exercise 2.0 (71) 2.0 (71) 20RESC 100 3.9 (136) 2.9 (102) 75 3.1 (109) 2.4 (85) LPG 50 2.3 (82) 1.8 (63) 25 1.7 (59) 1.3 (47) Exercise 1.0 (35) 1.0 (35) Nominal fuel rating: Natural gas: 37 MJ/m3 (1000 Btu/ft.3) LPG: 93 MJ/m3 (2500 Btu/ft.3) LPG conversion factors: 8.58 ft.3 =1 lb. 0.535 m3 =1 kg 36.39 ft.3 =1 gal. G4-246 (20RESC) 10/15a 0 0 @90 0 M Voltage: 240 V •� Freq: 60.0 Hz w .mo nn RDC2 Controller • Front -access mini USB connector for SiteTech- or USB Utility connection • Integral Ethernet connector for Kohler® OnCue® Plus • Built-in 2.5 amp battery -charger , • Remote two -wire start/stop capability for optional connection of a Model RDT transfer switch The RDC2 controller provides integrated control for the generator set, Kohler® Model RXT transfer switch, programmable interface module (PIM), and load shed kit., The RDC2 controller's 2-line LCD screeri displays status messages and system settings that are clear and easy to read, even in direct sunlight or low light. RDC2 Controller Features • Membrane keypad: o OFF, AUTO, and RUN pushbuttons o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF, AUTO, and RUN modes • LED indicators for utility power and generator set source availability and ATS position (Model RXT transfer switch required) • LCD display: o Two lines x 16 characters per line o Backlit display with adjustable contrast for excellent visibility in all lighting conditions • Scrolling system status display: o Generator set status o Voltage and frequency o Engine temperature o Oil pressure o Battery voltage o Engine runtime hours, • Date and time displays • Smart engine cooldown senses engine temperature • Digital isochronous governor to maintain steady-state speed at all loads • Digital voltage regulation: ± 1.0% RMS no-load to full -load • Automatic start with programmed cranking cycle • Programmable exerciser can be set to start automatically on any future day and time, and run every week or every two weeks • Exercise modes: o Unloaded weekly exercise with complete system diagnostics o Unloaded full -speed exercise o Loaded full -speed exercise (Model RXT ATS required) • Diagnostic messages: o Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PIM), and load shed kit o Over 70 diagnostic messages can be displayed • Maintenance reminders • System settings: o System voltage, frequency, and phase o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability. o ATS position (normal/utility or emergency/generator) o Source voltage and frequency • ATS control (Model RXT ATS required): o Source voltage and frequency settings o Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings • Programmable Interface Module (PIM) status displays: o Input status (active/inactive) o Output status (active/inactive) • Load control menus: o Load status o Test function Generator Set Sound Data Model 20RESC 8 point logarithmic average,sound,levels are 64 dB(A) during weekly engine exercise,and 69 dB(A) during full -speed generator diagnostics and normal operation. For comparison to competitor ratings, the lowest point sound levels are 62 dB(A) and 67 dB(A) respectively.* , All sound levels are measured at 7 meters with no load. * Lowest of 8 points measured around the generator. Sound levels at other points around generator may vary depending on installation parameters, G4-246 (20RESC) 10/15a KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features • Battery cables • EPA certified fuel system • Corrosion -proof polymer sound enclosure • Critical silencer • Field -connection terminal' block • Fuel solenoid valve and secondary regulator • Line circuit breaker • Multi -fuel system, LPG/natural gas, field -convertible • Oil drain extension with shutoff valve • Premium 5-year limited warranty • RDC2 generator set/ATS controller • Rodent -resistant construction • Sound -deadening, flame-retardant foam per'UL 94, class HF-1 Available Accessories Approvals and Listings ❑ CSA approval Communication Accessories ❑ OnCue® Plus Generator Management System ❑ OnCue® Plus Wireless Generator Managemen Concrete Mounting Pads ❑ Concrete mounting pad, 3 in. thick . ❑ Concrete mounting pad, 4 in. thick (recommended for storm -prone areas) Electrical System ❑ Battery ❑ Battery heater, 120VAC ❑ Battery heater, 240VAC ❑ Emergency stop�kit ❑ PowerSync® Automatic Paralleling MOdule'(API (single phase only) ❑ Programmable interface module (PIM) (provides 2 digital inputs and 6 relay'outplits) System Kohler Power Systems Asia Pacific Headquarters , 7 Jurong Pier Road Singapore 619159 Available Options, Continued Fuel System ❑ Flexible fuel line Literature - ❑ General maintenance literature kit ❑ Overhaul literature kit ❑ Production literature kit Maintenance ❑ Maintenance kit (includes air -filter, oil, oil filter, and spark plugs) Starting Aids ❑ Carburetor heater, 120 VAC ❑ Carburetor heater, 240 VAC. - Carburetor heater is recommended for reliable starting at temperatures below 0°C (32°F ) ❑ Fuel regulator -heater pad 120VAC ❑ Fuel regulator heater pad 240VAC Fuel regulator heater is recommended for reliable starting at temperatures below 718°C (0° F) . Automatic Transfer Switches and Accessories ❑ Model RDT ATS ❑ Model RXT ATS ❑ Model RXT ATS with combined interface/load management,board ❑ Load shed kit for RXT or RDT ❑ Power relay modules (use up to 4 relay modules for . each load management device) ❑ Other Kohler@ ATS Generator Set Dimensions and. Weights Overall Size, L x W x H: 1216 x 665 x 733 mm (48 x 26.2 x 29 in.) Shipping.Weight: _243 kg (535 lb.) is NOTE Dimensions are provided for reference only and should not be used for planning Installation. Canted your local distributor for more detailed information. DISTRIBUTED BY: reserved. G4-246 (20RESC) 10/15a m U2 x.x 1 .i �P l�J 8 7 6 5 4 3 2 I D D 1217 7 9 AIR INLET OW VOLTAGE ' c %HAUST AIR ELECTRICAL C _ OUTLET c STUB -UP AREA C 1 /2 NPT 1 ® ® ® FUEL INLET (3 13 3 d% 8 1 I.50 A.d 3 1 Idl 6 0 , 13 0 5 IB•61 ION VOLTAGE 63 ELECTRICAL • STUB -UP AREA NOTE DIMENSIONS IN CI ARE INCH EOUIVALENTS. A A d% II 0 [O. d3] MOUNT NG HOL S xE DATE amrourt an.. ea BY�'"�11p4 WNLERCQ[ xn...bins [xzoxn-il w 0 10 6 d d x. ra(o x�axx. Ean A-. .E.x. YtE'� x o[xltxxw(y (T� t it .M[I <o. x �rw[UMMM N PRWi �•oox ia�a�Il ,,, 1 WADV-8424 M/20RESA oox is-a-n iz '"m nx is-z.-n D 8 7 6 5 4 3 2 I r - - ,r s jai ,'(\1�\`--• Figure 1-5 Dimension Drawing ADV 8424, Sheet 2 I - - - . - 14 Section 1 Installation I TP-6803 12/11 _t In CD 7 v �n D v 00 N P. W m a w i 1 111 ...: ,'. USB PORT ONTROLLER r'.� , � " .•.•C � �f v �.1 - r,` ♦ � � 1. ON NECTION BLOCK ILOCATED 13EHIND PANEL) ATTERY CABLES IL DRAIN ROSE �- �_� Mon �LZEIIO ivmgm A 9 8 7 6 5 4 3 2 I OCCUPIED STRUCTURE OCCUPIED STRUCTURE OCCUPIED STRUCTURE D OCCUPIED STRUCTURE D N SERVICE DOOR SET E V SERVICE DOOR 00 - - SET _ VFW oV„i C - uo<6 C SERVICE DOOR r m y4u SET ri SET - o C7 - SERVICE DOOR o o. w 0 Ve 6 1 A N lL NA NIN IDES ma F M TA DISSTANCE TO LAWN FURNITURE, _ SENSITIVE PLANTS, ETC. y - ACCE"ANA r -I-E%HAUSL IS AIMED AWAY OR PARALLEL TO STRUCTURE. B 2) E%HARST IS NO7 DIRECTED AT PLAY AREAS�)0 ATS-OR _ OTHER ARE ASWHERE PEOPLE CONGREGATE. 3) THE NEAREST WINDOW, VENT. DOOR OR SIMILAR STRUCTURE 0 OPENING IS Al LEAST 5 FEET FROM THE EXHAUST END OF THE SET. FRS NOTE: RECOMMENDED DISTANCE FROM A SET 4) SET HAS PROPER OFFSET FROM STRUCTURE. 1) EXHAUST IS COMPLETELY AIMED AWAY FROM THE STRUCTURE. STRUCTURE IS DEPENDENT ON STATE AND LOCAL CODES. DEPENDENT 37, STANDARDS 5) WINDOWS 8 DOORS ON ADJACENT WALLS ARE CLOSED. 2) EXHAUST IS NOT DIRECTED AT PLAY AREAS. PATIOS OR OTHER FOR THE INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES 6) FURNACE AND 07HER SIMILAR INTAKES ARE AT LEAST 10 FEET FROM - AREAS WHEAE PEOPLE CONGREGATE. AND GAS TURBINES, STATES THIS EXHAUST END OF SET. 3) OR DFAOM IE%HAUSTTEND DISTANCE SHOULD BE -AT LEAST 5 FEET UST 7) WEED BARRIER AND 3 INCH THICK GRAVEL BASE LOCATED TO PREVENT OPENNNGRI STATILEASS' SEIAL FE ET THE OFETHE SET. INSTA LLATNOHS NONECOMB USTIBLE GRASS A WEEDS FROM GROWING TOO CLOSE TO THE SET. 4I SET HAS PROPER OFFSET FROM STRUCTURE. MATERIAL BE SURE TO LEAVE A MINIMUM DISTANCE OF 3 FEET TO ENSURE e) NO PLANTS. SHRUBS UBS OR OTHER COMBUSTIBLES ALLOWED IN PROPER GENERATOR COOLING. GRAVEL AREA. ' 5) WINDOWS Ill DOORS ON ADJACENT WALLS ARE CLOSED. 9) SENS171VE PLANTS, PATIO FURNITURE, ETC. ARE AT LEAST 8 FEET. FROM 6) FURNACE AND OTHER SIMILAR INTAKES ARE AT LEAST 10 FEET FROM EXHAUST END OF SET. EXHAUST END OF SET. ID) REFER TO OWNERS MANUAL FOR OTHER INSTALLATION CONSTRAINTS. A 7) WEED BARRIER AND 3 INCH THICK GRAVEL BASE LOCATED TO PREVENT A GRASS S WEEDS FROM GROWING T00 CLOSE TO THE SET. R[V DATE 1 ex WOHLERC.Q 8) NO OR OTHER COMBUSTIBLES ALLOWED IN,u{id • ID-zx•u x • DtAu xD rozoae-n oon rcuo mux,, ean. n u,u s. .rwloc�lL�,e2'iDPIIllilm'°c�f0' x GRAVELNAR�ASHRUBS J. e.. i efdm ICiFn}8: 3f`YI• 1e. D.R, of 9) SENSITIVE PLANTS PATIO FURNITURE. ETC. ARE AT LEAST 8 FEET FROM C'Bz:J EXHAUST END OF SST. DU/FIRlriION PRBVT 10) REFER TO OWNERS MANUAL FOR OTHER INSTALLATION CONSTRAINTS. oax to-tx•II 14A20RETiA z,D u• ADV-8424 I D 8 7 6 5 4 3 2 I