HomeMy WebLinkAboutGENERATOR ADDITION RISER DIAGRAMABBREVIATIONS: AC ALTERNATING CURRENT MCC MOTOR CONTROL CENTER GENERAL NOTES: A/C AIR CONDITIONING MTS MANUAL TRANSFER SWITCH 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. AL ALUMINUM MLO MAIN LUGS ONLY AHU AIR HANDLING UNIT NEC NATIONAL ELECTRICAL CODE 2. LIGHT / DASHED LINE WORK REPRESENTS EXISTING TO ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS BE REMOVED. AMP AMPERE ASSOCIATION AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION 3. DARK AND RED LINE WORK REPRESENT NEW ANSI AMERICAN NATIONAL STANDARDS INSTITUTE PLCS PLACES (QUANTITY) EQUIPMENT, CONDUIT, AND WIRE. C CONDUIT PNL PANEL CU COPPER CONDUCTOR PVC POLYVINYL CHLORIDE CONDUIT COVB CITY OF VERO BEACH RMC RIGID METAL CONDUIT DC. DIRECT CURRENT RTU ROOF TOP UNIT EXIST EXISTING TYP TYPICAL FPL FLORIDA POWER & LIGHT TEMP TEMPORARY G GROUND UG UNDERGROUND GFCI GROUND FAULT CIRCUIT INTERRUPTER UL UNDERWRITERS LABORATORY ---- - -- - - - - ------ IRC INDIAN RIVER COUNTY LION UNLESS OTHERWISE NOTED KVA KILOVOLTAMPERE V VOLT KW KILOWATT VA VOLTAMPERE MC METAL CLAD CABLE W WATT LOAD SHED: MCB MAIN CIRCUIT BREAKER XFMR TRANSFORMER (1) 2.5 TON AC CONTROL CIRCUIT GEN ERAC' (1) HEATING ELEMENT 2"PVC CONDUIT (1) 2.5 TON AC CONTROL CIRCUIT (2) #310 THHW CU (LINE) (1) HEATING ELEMENT COMPLETE ELECTRIC INC. (1) #310 THHW CU (NEUTRAL) 637 SEBASTIAN BLVD. (1) #6 THHW CU (GROUND) SEBASTIAN, FL 32858 (72) 388-OW ATTIC F7ATTIC ------------ ------ - -- - - ---- ------ -- ---- Sizing Report - _ --- (EXISTING) j (NEW) (EXISTING) 2" PVC CONDUIT String Information for. 225AMP 7GENERAC. 00 AMP INTERIOR (2) #3I0 THHW CU (LINE) Bober (EXISTING) MAIN HOUSE I (1)#310THHW CU(NEUTRAL) 2710 BENT PINE DR 20I AMP DISC SE RATED PANEL (1)#6THHW CU(GROUND ) Fort Pierce, FL34051-2656 METER I ATS Rated Nominal Voltage 240 SOCKET I Generator FuelChdoe Propane 120/240 1,p _ String Method (NEC 220) Part IV 1 \ 2" PVC CONDUIT (Part ill required for selected circuit Implementation, Both valid for whole house) `- (2) #4/0 XHHW AL (LINE) ; General Lighting & Receptacles Load (kW) (1) #4/0 XHHW AL (NEUTRAL) Square Footage Being Covered (02) 2400 7.2 (1) #6 THHW CU (GROUND) Small Appliance Circuits (20 amps) Kitchen (EXISTING) 2" PVC CONDUIT 1-1/2" PVC CONDUIT Laundry Circuits 2 3 (2) #310 THHW CU (LINE) (2) #3 THHW CU (LINE) aundryClrcuite 1 1.5 (1) #3/0 THHW CU (NEUTRAL) (1) #3 THHW CU (NEUTRAL) (1) #8 THHW CU (GROUND) Managed Estimated Nameplate (6) #14 THHN CU ) Fixed -In -Place Appliances & Motors Loads (kW) (-Ps) 240 V Load (It"D Dryer 6.5 0 X 6.5 #4 BARE CU Microwave 1.3 0 1.3 IN1/2"CONDUIT Range - Ovenwl Top eS 0 X 8.5 Pool Heater 5.0 0 X 6.0 (NEW) GENERATOR: Dishwasher 1.6 0 1.6 Refrigerator 0.8 0 0.8 - #4 BARE CU AIR COOLED Refrigerator 0.8 0 0.8 IN 1/2° CONDUIT GENERAC 22KW Pool Pump 2.0 0 2.0 COLD WATER BOND ®100AMP WeIlPump 1.5 0 1.5 -- BREAKER _ Managed Estimated Nameplate GRADE '� --- -- -- - - --. _ __-----_----- - - GRADE Air Conditioning & Coolfnp Loads (kW) (amps) 240 V Load (kW) (EXISTING) 2" PVC CONDUIT - _ 2.6Ton Unit X 2.5 0 X. 0.0 (2) #4/0 XHHW AL (LINE) Managed Estimated Nameplat (1) #4/0 XHHW AL (NEUTRAL) (EXISTINGe WATER LINE Heatln 8 Neat Puma Loads(+) 240 V Load k i heating ore X 0.0 40 X 0.0 heating element#2 X 0.0 40 X 0.0 (EXISTING) (2) 5/8" X 8' -� CU GROUND RODS Estimated Actual Utlltred Trenslem uirement (URA) (LRA) (URA) Largest Motor's t ng Ampe ( RA) 276 64 64 Load NEC SCOPE OF WORK: GENERAL NOTES: Summary NEC Load (kW) Required • PROVIDE AND INSTALL 200 AMP BE RATED ATS IN ROOM ADJACENT TO GARAGE. . THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION General Lighting & Receptacles 11.7 RE -FEED INTERIOR MAIN PANEL AND SEPARATE NEUTRALS AND GROUNDS IN MAIN DETAIL WITH THE LOCAL UTILITY POWER COMPANY. Fixed -in -Place Appliances & Motors 26.e PANEL. . THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE LOCAL ORDINANCE, AND Sum of all General Loads 38.8 21A • FORM AND POUR PAD FOR GENERATOR. THE NATIONAL ELECTRIC CODE, PRESENTLY IN EFFECT. r. Costing 0 0 • PROVIDE AND INSTALL (1) 22kW GENERAL LP GAS GENERATOR. . ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AN CRAFTSMAN LIKE MANNER BY ; - • PROVIDE AND INSTALL CONDUIT AND CONDUCTOR FROM NEW GENERATOR TO PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF A MASTER ELECTRICIAN Heating (wltlemand facto 0 0 r"=� NEW ATS. Larger of Heating & Cooling 0 0 r LICENSED IN THE STATE OF FLORIDA. • LOAD SHED (2) HVAC SYSTEMS. . THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND String based on a of NEC Article 22 PartIV 21A • LP GAS LINE FROM EXISTING LP TANK TO GENERATOR IS INCLUDED. USE SECURE FASTENED, WITH WORKING SPACE PER NEC 110.26. Elevation �a 0 it GAS AS A SUB -CONTRACTOR FOR THIS CONNECTION. . PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT Min a pa r torstarting require me 8 J ' • NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. to A� "' °•' r r SCOPE OF WORK. . ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED � G Qw�S 350000 ,9 t TESTING LABORATORY. rJ '`% `��ji c Ge orator Recommended • GROUNDING PER NFPA 70 2011 EDITION ARTICLE 250. 8v • STANDBY SYSTEM INSTALLATION PER NFPA 70 2011 EDITION ARTICLE 702. AND MANUFACTURER INSTALLATION GO INSTRUCTIONS. LOAD MANAGEMENT ��Q 061 NQ PEP; O p"LCM"LOAD SHED QE LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND F(ONE-gE M LOADSONLY SHED NECESSARY BY SHEDDING T ENONESSENTIAL C RCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS QQ� S POWERED. LOADS ARE SHED THROUGH ST MO�N� INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). O �1p15 NO SCALEGENERATOR ADDITION RISER DIAGRAM t a �x Z 00 to CM Z Cl) U Q W o orb WQQ� F_W�� W co av m 2(D LU U O U _ J JLLJ Uo U x W QO UD W O W 0 ❑ C9 Q of W Lo °o� fY U ❑ 0qL LL gaviaW Lij Z W Z W (D0MI- W W r-. 0 Z N LL E1 -4z 06/15/2017 IMT 1 OF 2 N PARTIAL SITE PLAN W E S DRILL CLEAN DRIVE TIGHTEN 3-5 X DRILL 1/4" IEEPER THAN ,NCHOR BEDMEN 1/4" MI 54" DRILL BIT SIZE: 1/2" TIGHTENING MIN. ANCHOR TORQUE:45ft.lbs. EMBEDMENT:2-1/2" NOTE: ' �\ I j THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15IS RECOMMENDED. 32" --{ TOP VIEW 6" MIN. I-- 32" I- 54" LEFT ELEVATION FRONT ELEVATION GENERATOR PAD DETAIL W p �o c < u� USN �ZMcn 0 1, Up, W F—�b uduQZ� Lu W co J co I.- a m � W W 0 U j ucD ELw cc J O �LLo z t= Lma o6 O >0> WOR C)o- � OQu1LL �zw a z w z ir WMWLU OOm �:ofo� W r-O Z N LL E2 .,.06/15/2017 m _- 20F2