BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method,
Permit #• % � 0 7 C $ey D
RECEIVED
MAR J42010
Permitting Department
St. Lucie County
Job Address: L oT 3 A-JA-Ld" i3<�tAc P . CIuQ
Constructions ( ) New Construction- Complete ( )'Existing - After Addition
House Infiltration: Test Results SL"C Climate Zone'2
CFM (50)= ts ('3 Test Date:
Volume "_ 4a> 9'3
ACH (50) CFM (50) x 60 / Volume = 3 it _ . Mechanical Uentilation required less than 5 ACH
Passing results.must be & ACH (50) or less ( LIPass ( )Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having amair leakage rate: of not exceeding ?air changes per
hour in Climate Zorie.1, 2 and 3 air changes.per hour in Climate Zones 3through 8. Testing shall be conducted with a
blower door at a pressure:of'0.2 inches w. g. (50,PascaN). Testingshall be.conducted, by either individuals as'defi.ned in
Section 553.993(5)*or (7), Florida' Statutes or individuals.licensed as set forth im Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written.report of the results of the test shall be signed. by-theparty conducting the test•and
provided to the code official. Testing shall be performed.at anytime after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less.than 5 air:changes-per hour when tested with.a blower door at.a
pressure of 0.2 inch w. c. (50 Pa) in;accoedante with Section M02.4.1.1 of the Piorlda Building Code, Energy Conservation
the dwelling unitshall be provided with whole -house mechanlcal ventilation in accordance with Section M1507.3.
Testing Company
Company Name: f.0 ` 'f . i2A -s �i" ` Address: ��/ r .N W N� '�- 4 L fj
I hereby:certifythat the:above House infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section'R402.4.1.2 Climate Zone 2.
Signature: !)C:a 8�✓.
Printed Name: S C-a-1 "1- ^+' `
License/Certification. #: C AC t el 3 6 9-5-9 3 �- �.- a 9 7