HomeMy WebLinkAboutPROJECT INFORMATIONProject Summary wrightsoft � Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772.46E Email: For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design-TD 28 OF Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method .. Construction quality Fireplaces Area (W) Volume (ft3) Air changeslhour Equiv. AVF (cfm) Fort Pierce, FL, US .Simplified Average 0 Heating1753 Cooling1753 14741 14741 0.38 0.20 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heatinginput Heating output 34600 Btuh @ 470F Temperature rise 27 - °F Actual air flow 1160 cfm . Airflow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE 8.5 HSPF Job: Date: By: Summer Design Conditions Outside db 90 OF Inside db 75, OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 gr/lb Sensible Cooling Equipmentioad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554. Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at.0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037- AHRI ref 7914585 Efficiency 12.0 EER, 15-SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800'. Btuh Actual airflow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. " wrightsoft` 2017-Apr-1017:19:28 �- Right-Sufte® Universal 201717.0.14 RSU08101, Page 1 ACCA' A CalcsMocumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front,Door faces: N + wrightsoft' Right-.10 Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772, 466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 3 Exposed wall Room height 153.0 ft 8.4 ft d . 45.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1753.0 ft2 1.0 x 280.0 ft 280.0 ft2 Ty Construction number U-value (Btuh/f?-°F) Or, HTM (Btuh/ft2) Area 2 or perimeter (ft) (Btuh) s (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 11 A V 13AAocs 1A c1om 1A c1om 1A1om =°. 13AAocs .11D0 13A-flocs' , . W-26m' ° 13AAocs 1A-c1om 4A5-2omd 12C-0§w• 16A-30md '22A-tpl :. 0.140, 1.270 1;270 1'270 0.143 0.390 0:143 0 770 0.143 1.270 0.770 0:001 0.032 0989 ne ne ne . ne se se sw ; sw nw nw nw . - `::-: 4 00 _ 35 56 35 56 35.56 4.00 1092 - 4 00 21 56 4.00 35.56 21.56 25.5 0.90 " 27.69 2 55 , 70 43 7043' 45.24 2.55 . 11.31 ; 2 55 ;; 27:53 2.55 45.24 36.90 128 2.32 ,: 0.00 488 + �7 16 16 64 23 ', .437 : 41 290 33 41 30.8 1753 1753 448 0 0 . 0 41 23 396 . 45 217 0 0 :.. 308. 1753 IM 179.5 247 581 581 165 248 1584 893.: 867 1162 880 '784 1571 4237': 1141 488 :1151 - 739 105 257 '1007 1140 551 1478 1505 ," -395 4067 l) 192 0 0 0 . 0 ,56 0 112 33 0 : 0.``. 280 . 280-- 192 0 0 : 0 0 0 ; 66 :.. 0 79 0 0 0: 280 ;. 45 . 769 : 0 0; -.. • 0 0 0 .:: 224 : 0 318 1162 0 0 251 1246 489 0 :0 0 0 0 143 • . .: 0 202 1478 0 _ :'0 650 :. "A V�1 -D, �G, `P C F 6 c)AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 34% 53%1 0 0 18467 6190 .0 0 17655 9340 34% 53% 0 0 4779 1602 0 0 3789 .2005 Total room load Air required (cfm) 7 24657 1160 26995 1160 6380 300 5794 249 1 Calculations.approved byACCA to meet all requirements of Manual .J.8th Ed. .� - wrightsoft, 2017-Apr 10 17:19:28 Aedk ±Z= Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsoft' RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name WIC M. ' BATH 2 3 4 5 Fposed wall Room height Room dimensions Room area 0 ft 8.0 ft heaticool 7.0 x 9.0 ft no ft2 7.0 ft 8.0 ft heaticool 1.0 x 61.0 ft 61.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area 2Load or perimeter (ft) (Btuh) (ft2) oorperimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 AM ­IA-clom 1Ac1om 1A-c1om . 13A-4ocs 11130 1394ocs. 4A5 tom %. 13A4ocs 1A-clom 4A5-2omd ;;12C-0'sw 16A30md '22AApl 0.143 1.270 1:270 1.270 0.143 0 390 0;7g3 0:770 0:143 1.270 0.770 0.09,1 0.032 0:980 ne ne " ne ."ne ; se se sw nw nw _ nw„ , - _ - - 4 00 35 56 35 56 " 35.56 4.00 10.92 4 00 21:56 4.00 35.56 21.56 2.55. 0.90 2Z:69' . 2.55 70 43 : 70:43 ` 45:24 2.55 11 31 ' 2 55 ; 27`53 2.55 45.24 36.90 128 2.32 0:00 0 ' 0 .. .0 ' 0 0 0 p 0 0 0 0, : 0 63 63 0 0 ' .. ... 0 0 0 0 p . 0 0 0 0 0 63 0 0 0 0 0 0 0 0` 0 0 0 0. ,0 56 0 0 0 0 ..: 0 0 0 0 6 0 0 0 p 146 `, 0 56 7 ,.... 0 0 0 0 A .. 0 0 0 - 0 ; 0 61 61 49 0 :. 0 ' 0 0 0 0. 0 0 0 " 0 p 61 , . 7 196 : 247 p 0 0 0 ` 0 0 0 0 , 0 55 . " " "194' 125 486 0 0 0- 0 :0 0 0 0 .: " 0 142 : 0. V}/ r--D L—C �1 I--G �--G P C F 6 c)AED excursion -5 726 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 141 817 764 Less edemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 56 0 0 141 0 0 817 0 0 764 15 Duct loads 34% 53% 19 75 34% 53% 274 404 ITTotal room load I I = 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved bvACCA to meet all requirements of Manual J, 8th Ed. AeUk wcightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2 ...k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsoft- RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. ey. 317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: ..QUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 2 3 • F�q�osed wall Room height 0 ft 8.0 ft heat/cool 12.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft2 Ty Construction number U-value (Btuh/ft22F) Or HTM (Btuh/ft2) Area 2 or perimeter (ft) Load (Btuh) 6jea (ft2) or perimeter (ft) Load (Btuh) Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 1A c1om 1Ac1om : 0.143 1270 1.270 ne , ,he ne , .4.00, 35 56 3556: 2.55 70 43 7043 0 • 0 :0 0 0 :0 0 0 0; 0 0 0 96 0 16':.: 80 0 0' 319. _ 'o S81 2003 1151 11 1A�1om .. 13A�4ocs 1:270 0.143 . ne se _35.56 4.00 45.24 2.55 0 0 0 0 . 0 0 0.-..,.:. 0 0 0 _0.,. 0 6' 0 0 0 T �D 13A-0ocs ,: 13A4ocs 1Ac1om ,4A5-2omd. 12C Osw " -16A30md 22A-tpl : :.. 0.390 o 143 0.143 1.270 0.770 .0:091 0.032 : 0:989 se sw . nw nw , nw = " - =.4 10.92 ; 4.00„ 21.56 4.00 35.56 21.66 2.56 0.90 .` ..27 69 11 31 255E , . 27.53 2.55 45.24 36.90 . 1 28 2.32 : 0.00 0 <0 ` 0 0 0 0 ::. :.0 36 : -36 0 0 0 0 0 0 0 36 0,.,180 0 0 0 0 0 0 .. ' . 0 32 0 ' 0 0 0 0 0. t . 0 84 0 0 ':: 0 0 0 0 i° 0 180 0 0 0 0. 0 0 .:' 0 180 :.: 12`332 0 0. ., , 0 0. 0 0 ,' , 0 161 0 0 0. 0 0 0 A, 418 : = `0 aw V�1 ' G, P C F 6 c) AED a -ursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 1609 1772 Less extemal load 0 0' Less transfer ff328 0 . 0 Redistribution 6 14 14 Subtotal' 1015 1786 15 Duct loads 34°/a 53% 340,16 MOON 541 945 Total room load 1 51 145 2156 2730 Air required (cfm) 2 6 101 117 f Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- wrigF ttsOftRight-Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page age 3 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cato = MJ8 Front,Door'faces: N - - wrightsofts RighW Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name DINING/GREAT'ROOM KITCHEN 2 Exposed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heaticool 4 5 Room dimensions Room area 1.0 x 588.0 ft 588.0 ftz 19.0 x 11.0 ft 209.0 ftz Ty Construction U-value Or HTM Area (ft-) Load Area (ft?) Load number (Btuh/ft;°F) (Btu 2) or perimeter (ft) (Eat h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6A 13A110gs 0.1413 <,ne 4:00 . 2.55. 0 0 0 0 0 '0 0 D 1A61om IlXdlom `1A�1om: 1:270 1.270 :1.270 ne ne ne 35 56 •" 35 56' 3556. 1.0 43 70.43 45:24 ` 0 , . 0 0 0 0 0• 0 0 0 0 0 -,: 0 Q .. 0 '0 0 : 0 0; 0_ 0' 0 0 0' "0 11 Y—D 13A4ocs 0.143 se 4.00 2.65 0 0 0 0 0 0 0 0 11130 , 134 s _ 0.390 0:143 se sw 1092 4 00' _ 11.31 2 55 0 267 0 226 0 =� 903 0 574 0 98 0 > ,: 98 0 . -,392 0 .249 '4A5 tom OJ16 sw- . 21 56 ;: 27.53 41 22 _893 :. 1140 0 0 ' :0' Al . VN I—G 13A4ocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 178 0 137 0 549 0 349 0 0 0 0 0 0 0 0 0 l—G 4A5.2omd 0,770 nw 21.56.. 36.90 41 0 880 1505. 0 0 0 0 P C ;12C-0sw 16A30md :0 091 0.032 , � 2:55 0.90 ? :128 2.32 0 588 L 0 588 : 0. 527 0 1364 ::. 116 .209 .. `:. . ' 116 209 '.'. ' ` 295 187 ' . '" 148' 485 0i989 . '. _;... .27-.69 . •. 0.00., 588 50 ' 1385 0 209 '. ; ; ' :. _ 11 ' 305 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460, 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 . 1880 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 1151 Duct loads 1 340/6 53% 2058 3541 34% 530/. 4691 995 Total room load I 8200 10234 1 1867 2875 Air required (cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fp- wrightsoft- 2017-Apr-1017:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8. Front Door faces: N -r- wrightsoft° Right-JO Worksheet Date: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946.Phone: 772-46M799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ftZ 25.0 ft2 TY Construction U-Yalue Or HTM Area (ft-) Load Area (ft� Load number (Btu1Vft2-°F) (Stuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat C001 Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W 13AAocs 0.143 ne .4.010, 2.55. 40 40 160 102 0 0 0 0 1A-c1onn 1.270 ne 35'56 70.43 0 0 0 c i0 U. 0.. '0 0: 1Ac1om :. 1:270 ne.' 3556 70.43: 0 0 0 0 .0•. 0. "0 0 1Ac1om . 1?27,0 :ne. . 3556 45:24 0 0 0 0.. .0. 0 0 0. 11 �. 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 ... 0 11DO 0.,390 se 10.92 11.31 0 0 0, 0 0 0 0 0 y/ 13A-4ocs 0143 sw'. " 4.00, '255 : , p , . 0 0 0 ., 0 : 0 • , 0 0 0:770 sw'. .. 21.56, : 27.53 .. 0 0 ' 0 . . • 0 - 0 0 ` 0' .0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 01 0 0 0 4A5-2omd 0.770 nw 21.56. _ 36.90 0 0 0 0 0 0. 0 0 p, :.12C-Osw'. `6091 :; _ 2:55.. `'128 '.' 0 0 . 0 0 C 16A-30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 `F' " `22A-tpl '0.989 2T.6.9 '. 0 06 50 5 138 ': 0 _ 25 ; .0 0 6 c)AED emursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 56 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 1 340/a 53%1 147 132 34% 53%1 0 0 Total room load 586 381 1.0 0 0 Air required (cfm) 28 16 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed.. .�C�A wrightsOft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-4r-10 1 Page 5 ..:k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrlghtsoft* ROW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. ft: 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@t10L.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft' Ty Construction number U-value (Btuh/ft2-'F) Or HTM (Btuhlftz) Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool - 6 11 13A4ocs 1Ac1om 1Ac1om 1A c1om; 13A-4ocs 0:143 1:270 1270 .1.270 0.143 . ne ne ne ; ne se 4.00 35 56' 35 56 35.56I 4.00 . 2.55 ".70.43.. : 70 43 : . 4524 2.55 - 0 0 ., 0 " 0 64 0, 0 0 0 41 0 0 0 0 165 . 0 0 0 0 105 104 0 0 16 0 88 A :. p 0 0 351. . 0 0 : 581 0 223 0 : p'. 739 0 y! L--D 11D0 13A1Iocs 4A5 tom '.' 13A4ocs 1A-c1om 0390 01,143 0770 .0.143 1.270 se sw .sw nw - nw 1092 :. 4 00 21.56 4.00 35.56 _ 1131 ; 2 55 > 27.53 2.55 45.24 23 . �8 ' ;0 0 0 23 - 8 . 0 0 0 248 32 , 0 0 0 257 . ; 20 0 0 0 0 8 •• 0 0 0 0 - 8 0 0 0 0 : `32 p:. 0 0 0 20: 0 0 W r G 4A5 2omd 92C-0sw;:r. 16A 30md 0.770 0 091' 0.032 0989 nw , .. -.. - 2 21.56, 55 0.90 27.69 36.90 >128 2.32 ; • '0:00 0 = .,;88 92 : 92 0 88 92 g 0 7224 82 2 0- : 113 213 0 0 : ' ,' 104 169 .. 169 0_ ;104 169 ... 14 0 " 265 151 ; .: 0 . ' .:°-133 392 P C FF ; 6 c)AED excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less edemal.load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 1 340/6 530/o 390 386 34% 53% 677 808 Total room load 1553 1116 2697 2335 Air required (cfm) 73 48 1271 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr. ightsoft- 2017-Apr-10 17:19:28 MCP. Right-Sufte@ Universal 2017 17.0.14 RSU08101 Page 6 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N System Summary Job: -- wrightsoft Duct - . y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email:, QUICKCALCS@,AOL.COM Project • • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O. 0.60 .in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0:372 4.0 Ox0 VIFx 19.5 115.0 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 Ox 0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0:366 6.0 Ox0 VIFx 21.8 115.0 SO LAUDRY C 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC C 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 612 602 0.'273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx A wri htso' MCA Page 9 ftRight-Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:29 Page 1 ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm)-. TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mate Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:19:29 9 - Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N