Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEh File cCopY: FORM R405-2014 A FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: METREE ADDITION Builder Name: Street: 3605 S. INDIAN RIVER DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall'Types (480.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 480.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(1) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (331.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 331.00 ft2 6. Conditioned floor area above grade (ft2) 331 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(44.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 66 a. U-Factor: Sgl, U=0.65 44.33 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 58.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.667 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems - None required a. Cap: N/A 8. Floor Types (331.0 sqft.) Insulation Area EF: 0.000 a. Slab -On -Grade Edge Insulation R=0.0 331.00 ft2 b. Conservation features b. N/A R= ft2 c. N/A R= ft2 15. Credits Pstat. Total Proposed Modified Glass/Floor Area: 0.134 Loads: 16.10 PASS AS� Total Baseline Loads: 17.07 I hereby certify that the plans and specifications covered by Review of the plans and fliE ST•q?, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance vj iip 2 ���ti with the Florida Energy Code. mur''%-;;•``�:•;. O PREPA ED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 �- I hereby certify that this building, as designed, is in compliance Florida Statutes.0 with the Florida Energy Co OD WE"i� OWNER/AGENT._ d BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: METREE ADDITION User 1 ST. LUCIE COUNTY Single-family Addition Bedrooms: 1 Conditioned Area: 331 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 3605 S. INDIAN RIVER ST. LUCIE COUNTY FT. PIERCE, FL, CLIMATE V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 331 2648 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 331 2648 Yes 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio ADDITION 80 ft 0 331 ft2 ---- 0 0 1 ROOF v # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or shed Composition shingles 359 ft2 68 ft2 Medium 0.6 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 331 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 331 ft2 0.11 Wood 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below 1 —2 3 rI 4 W N E N Exterior Concrete Block - Ext InsuADDITION 4.1 12 8 96.0 ftZ Exterior Concrete Block - Ext InsLADDITION 4.1 28 8 224.0 ftz Exterior Concrete Block - Ext InsuADDITION 4.1 12 8 96.0 ftZ Exterior Concrete Block - Ext InsuADDITION 4.1 8 8 64.0 ftZ 0 0.6 0.23 0.6 0.23 0.6 0.23 0.6 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 2 3 W 1 Metal Low-E Single N 2 Metal Low-E Single E 3 Metal Low-E Single Yes 0.65 0.25 9.0 ftz 1 ft 8 in 1 ft 4 in Yes 0.65 0.25 5.3 ft2 1 ft 8 in 1 ft 4 in Yes 0.65 0.25 30.0 ftz 1 ft 8 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 308.9 16.96 31.9 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 16 58 kBtu/hr 1740 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF ftZ DUCTS / V # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT HVAC # QN RLF Heat Cool 1 Attic 6 66 ftz Attic 15 ftz Default Leakage Attic (Default) (Default) 1 1 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 - TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar A r Ma [X] Jun X Jul X Aug Se Oct Nov Dec Heating Jan Feb Mar E Apr Ma Y ]Jun 4 Jul 4 Auf Sep Oct Nov Dec Venting Jan Feb X Mar [X Apr Ma E ] Jun [ Jul [ Aug [ Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78. 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 .0 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: METREE ADDITION Builder Name: Street: 3605 S. INDIAN RIVER DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ' ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ' ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 3605 S. INDIAN RIVER DRIVE, FT. PIERCE, FL, 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 480.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1(1) d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 331.00 ft2 6. Conditioned floor area (ft2) 331 b. N/A R= ft2 7. Windows** Description Area c. N/A R= ft2 22 a. U-Factor: Sgl, U=0.65 44.33 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft 6 66 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 58.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 1.667 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems - None required Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 331.00 ft2 a. EF: b. N/A R= ft2 c. N/A R= ft2 b. Conservation features 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: O� T$E ST,q FAO coD WE `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 9 m Pr® ect Summary Job: Wrl htsoft ' 7 Date: Jun 22, 2017 Entire House By: QUICK CALCS, INC. p, 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM For: METREE RESIDENCE 3605 S. INDAIN RIVER DRIVE, FT. PIERCE, FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 30224 Btuh Ducts 10351 Btuh Central vent (68 cfm) 2097 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 42671 - Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Coolin Area (ft2)2391 2391 Volume (ft') 21519 21519 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 115 57 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 17448 Btuh 8 OF 1900 cfm 0.047 cfm/Btuh 0.50 in H2O Summer Design Conditions Outside db Inside db 90 OF 75 OF Design TD Daily range Relative humidity Moisture difference 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 28948 Btuh Ducts 15607 Btuh Central vent (68 cfm) 1123 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 43395 Btuh sensible Latent Cooling Equipment Load Sizing Structure 2397 Btuh Ducts 4329 Btuh Central vent (68 cfm) 2847 Btuh Outside air Equipment latent load 9573 Btuh Equipment total load 52968 Btuh Req. total capacity at 0.70 SHR 5.2 ton Cooling Equipment Summary Make American Standard Trade AMERICAN STANDARD Cond 4A7A7060A1 Coil TEM6AOD48H41++TDR AHRI ref 7567585 Efficiency 12.5 EER, 16 SEER Sensible cooling 39900 Btuh Latent cooling 17100 Btuh Total cooling 57000 Btuh Actual air flow 1900 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jun-22 13:26:58 wrightsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACC C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N -�- wrightsoft° Right-JO Worksheet Job: Entire House Date: Jun 22, 2017 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House EXISTING HOUSE 2 Exposed wall 270.0 ft 210.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 1.0 x 2060.0 ft 5 Room area 2391.0 ft2 2060.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-40cs 0.143 n 4.00 2.55 630 609 2440 1551 396 381 1526 970 CC 1A-clom 1.270 n 35.56 34.77 15 0 533 522 15 0 533 522 i; 4A5-2ob 0.560 n 15.68 16.16 6 0 88 90 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 585 469 1878 1194 468 382 1530 972 11 1A-clom 1.270 a 35.56 91.12 45 0 1600 4100 45 0 1600 4100 IA-c1om 1.270 a 35.56 91.12 20 0 711 1822 20 0 711 1822 4A5-2ob 0.560 a 15.68 43.95 30 0 470 1319 0 0 0 0 11 D0 0.390 a 10.92 11.31 21 21 229 238 21 21 229. 238 w 13A-4ocs 0.143 s 4.00 2.55 630 595 2382 1515 558 523 2094 1331 Ij1A-c1om 1.270 s 35.56 34.77 15 30 533 522 15 15 533 522 IA-clom 1.270 s 35.56 , . 34.77 20 40 711 695 20 20 711 695 w 13A-4ocs 0.143 w 4.00 2.55 585 479 1920 _ 1220 _ 468 _ 371 1487 945 1A-clom 1.270 w 35.56 91.12 15 0 533 1367 15 0 533 1367 IA-clomd 1.270 w 35.56 91.12 82 0 2902 7435 82 0 2902 7435 4A5-2ob 0.560 w 15.68 43.95 9 0 141 396 0 0 0 0 C 1613-30ad 0.032 - 0.90 1.68 2391 2391 2142 4017 _ 2060 2060 1846 3461 F I I 22A-tpl 0.989 - 27.69 0.00 2391 270 7477 0 2060 210 5815 0 6 c) AED excursion 0 -247 Envelope loss/gain 26692 28002 22051 24133 12Ia) Infiltration 3532 946 2747 736 b) Room ventilation 0 0 0 0 131 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1 30224 28948 24798 24869 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30224 28948 24798 24869 15 Duct loads 34% 54% 10351 15607 34% 54% 8493 13408 Total room load 40575 44556 33291 38277 Air required (cfm) 1900 1900 1559 1632 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� � wrightsoft26 ` Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Jun-22 13:Page 1 �� C:1Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJS Front Door faces: N ge 1 - wrightsoft` Right-J® Worksheet Job: Entire House Date: Jun 22, 2017 By: QUICK CAL.CS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name NEW BEDROOM NEW BATH 2 Exposed wall 31.0 ft 29.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 13.0 x 18.0 ft 1.0 x 97.0 ft 5 Room area 234.0 ftz 97.0 ftz Ty Construction U-value Or HTM Area (W) Load Area (ft') Load number (Btuh/ftZ °F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 6.143 n 4.00 2.55 162 156 626 398 72 72 288 183 1A-clom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 4A5-2ob 0.560 n 15.68 16.16 6 0 88 90 0 0 0 0 13A-4ocs 0.143 a 4.00 2.55 117 87 348 221 0 0 0 0 11 IA-clom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1A-c1am 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 4A5-2ob 0.560 a 15.68 43.95 30 0 470 1319 0 0 0 0 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 72 72 288 183 IA-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 W' 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 117 108 432 275 1A-clom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 1A-clomd 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 4A5-2ob 0.560 w 15.68 43.95 0 0 0 0 9 0 141 396 C 16B-30ad 0.032 - 0.90 1.68 234 234 210 393 97 97 87 163 F 22A-tDl 0.989 - 27.69 0.00 234 31 858 0 97 29 803 0 61 c) AED excursion I I 86 161 CEnvelope Toss/gain I 2601 2508 2040 1361 121 a) Infiltration 405 109 379 102 b) Room ventilation 0 0 0 0 131 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 F-, Subtotal (lines 6 to 13) 3006 2617 2419 1463 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3006 2617 2419 1463 15 Duct loads 34% 54% 1030 1411 34% 54% 829 789 Total room load I 4036 4027 3248 2252 Air required (cfm) 189 172 152 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrigF�tsoft' 2017-Jun-22 13:26:58 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N -- wrightsoft® Duct System Summary Entire blouse QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For: METREE RESIDENCE 3605 S. INDAIN RIVER DRIVE, FT. PIERCE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H 20 0.431 in/ 100ft 1900 cfm Job: Date: Jun 22, 2017 By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.431 in/100ft 1900 cfm Total effective length (TEL) 116 ft S,upplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk EXISTING HOUSE-1 c 38277 1559 1632 0 0 Ox0 VIFx 0 0 NEW BATH h 3248 152 96 0.431 6.0 Ox0 VIFx 21.1 95.0 NEW BEDROOM h 4036 189 172 0.442 8.0 Ox 0 VIFx 18.0 95.0 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1900 1900 0 0 0 0 Ox 0 VIFx ti + wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 AM C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N 2017-Jun-22 13:31:33 Page 1