HomeMy WebLinkAboutENERGY EFFICIENCY CODEh
File cCopY:
FORM R405-2014 A
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential
Performance Method
Project Name: METREE ADDITION
Builder Name:
Street: 3605 S. INDIAN RIVER DRIVE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall'Types (480.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 480.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms(Bedrms In Addition) 1(1)
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (331.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 331.00 ft2
6. Conditioned floor area above grade (ft2) 331
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(44.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 66
a. U-Factor: Sgl, U=0.65 44.33 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
58.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.667 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems - None required
a.
Cap: N/A
8. Floor Types (331.0 sqft.) Insulation Area
EF: 0.000
a. Slab -On -Grade Edge Insulation R=0.0 331.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
Pstat.
Total Proposed Modified
Glass/Floor Area: 0.134
Loads: 16.10
PASS
AS�
Total Baseline
Loads: 17.07
I hereby certify that the plans and specifications covered by
Review of the plans and
fliE ST•q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
vj iip 2
���ti
with the Florida Energy Code.
mur''%-;;•``�:•;. O
PREPA ED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
�- I hereby certify that this building, as designed, is in compliance
Florida Statutes.0
with the Florida Energy Co
OD WE"i�
OWNER/AGENT._ d
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
METREE ADDITION
User
1
ST. LUCIE COUNTY
Single-family
Addition
Bedrooms: 1
Conditioned Area: 331
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
3605 S. INDIAN RIVER
ST. LUCIE COUNTY
FT. PIERCE,
FL,
CLIMATE
V Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
331 2648
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
ADDITION
331 2648 Yes 1
1
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio ADDITION 80 ft 0
331 ft2
----
0 0 1
ROOF
v #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or shed Composition shingles 359 ft2 68 ft2 Medium
0.6
No 0.9
No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 331 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
ADDITION 30 Blown
331 ft2 0.11
Wood
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent
Cavity ity Width Height Sheathing Framing Solar
Below
1
—2
3
rI 4
W
N
E
N
Exterior Concrete Block - Ext InsuADDITION 4.1 12 8 96.0 ftZ
Exterior Concrete Block - Ext InsLADDITION 4.1 28 8 224.0 ftz
Exterior Concrete Block - Ext InsuADDITION 4.1 12 8 96.0 ftZ
Exterior Concrete Block - Ext InsuADDITION 4.1 8 8 64.0 ftZ
0 0.6
0.23 0.6
0.23 0.6
0.23 0.6
0
0
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
#
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Area Depth Separation
Int Shade
Screening
1
2
3
W 1 Metal Low-E Single
N 2 Metal Low-E Single
E 3 Metal Low-E Single
Yes 0.65 0.25 9.0 ftz 1 ft 8 in 1 ft 4 in
Yes 0.65 0.25 5.3 ft2 1 ft 8 in 1 ft 4 in
Yes 0.65 0.25 30.0 ftz 1 ft 8 in 1 ft 4 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
308.9 16.96 31.9 .2598 7
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity
Block
Ducts
1
Electric Strip Heat
None COP:1 34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
None SEER: 16 58 kBtu/hr 1740 cfm 0.75 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
ftZ
DUCTS
/
V
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
HVAC #
QN RLF Heat Cool
1
Attic 6 66 ftz
Attic 15 ftz Default Leakage Attic (Default) (Default)
1 1
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014 -
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Feb
Mar
A r
Ma
[X] Jun
X Jul
X Aug
Se
Oct
Nov
Dec
Heating Jan
Feb
Mar
E
Apr
Ma Y
]Jun
4 Jul
4 Auf
Sep
Oct
Nov
Dec
Venting Jan
Feb
X Mar
[X
Apr
Ma
E ] Jun
[ Jul
[ Aug
[
Se
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78.
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
.0
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: METREE ADDITION Builder Name:
Street: 3605 S. INDIAN RIVER DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 '
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
' ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
3605 S. INDIAN RIVER DRIVE, FT. PIERCE, FL,
1. New construction or existing
Addition 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4.1
480.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
1(1) d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
331.00 ft2
6. Conditioned floor area (ft2)
331 b. N/A
R=
ft2
7. Windows** Description
Area c. N/A
R=
ft2
22
a. U-Factor: Sgl, U=0.65
44.33 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft
6 66
SHGC: SHGC=0.25
b. U-Factor: N/A
ft2
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
58.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
1.667 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types Insulation Area 14. Hot water systems - None required
Cap: N/A
a. Slab -On -Grade Edge Insulation R=0.0 331.00 ft2 a.
EF:
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
O� T$E ST,q FAO
coD WE
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/22/2017 1:25 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
9 m Pr® ect Summary Job:
Wrl htsoft ' 7 Date: Jun 22, 2017
Entire House By:
QUICK CALCS, INC.
p, 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
For: METREE RESIDENCE
3605 S. INDAIN RIVER DRIVE, FT. PIERCE, FL
Notes:
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure 30224 Btuh
Ducts 10351 Btuh
Central vent (68 cfm) 2097 Btuh
Outside air
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 42671 - Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Heating
Coolin
Area (ft2)2391
2391
Volume (ft')
21519
21519
Air changes/hour
0.32
0.16
Equiv. AVF (cfm)
115
57
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
5.1 kW
17448 Btuh
8 OF
1900 cfm
0.047 cfm/Btuh
0.50 in H2O
Summer Design Conditions
Outside db
Inside db
90 OF
75 OF
Design TD
Daily range
Relative humidity
Moisture difference
15 OF
L
50 %
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
28948
Btuh
Ducts
15607
Btuh
Central vent (68 cfm)
1123
Btuh
Outside air
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.95
43395
Btuh
sensible
Latent Cooling Equipment Load
Sizing
Structure
2397
Btuh
Ducts
4329
Btuh
Central vent (68 cfm)
2847
Btuh
Outside air
Equipment latent load
9573
Btuh
Equipment total load
52968
Btuh
Req. total capacity at 0.70 SHR
5.2
ton
Cooling Equipment Summary
Make American Standard
Trade AMERICAN STANDARD
Cond 4A7A7060A1
Coil TEM6AOD48H41++TDR
AHRI ref 7567585
Efficiency
12.5 EER, 16 SEER
Sensible cooling
39900
Btuh
Latent cooling
17100
Btuh
Total cooling
57000
Btuh
Actual air flow
1900
cfm
Air flow factor
0.043
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat
ratio 0.83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Jun-22 13:26:58
wrightsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
ACC C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N
-�- wrightsoft° Right-JO Worksheet Job:
Entire House Date: Jun 22, 2017
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
1
Room name
Entire House
EXISTING HOUSE
2
Exposed wall
270.0 ft
210.0 ft
3
Room height
9.0 ft d
9.0 ft heat/cool
4
Room dimensions
1.0 x 2060.0 ft
5
Room area
2391.0 ft2
2060.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-40cs
0.143
n
4.00
2.55
630
609
2440
1551
396
381
1526
970
CC
1A-clom
1.270
n
35.56
34.77
15
0
533
522
15
0
533
522
i;
4A5-2ob
0.560
n
15.68
16.16
6
0
88
90
0
0
0
0
13A-4ocs
0.143
a
4.00
2.55
585
469
1878
1194
468
382
1530
972
11
1A-clom
1.270
a
35.56
91.12
45
0
1600
4100
45
0
1600
4100
IA-c1om
1.270
a
35.56
91.12
20
0
711
1822
20
0
711
1822
4A5-2ob
0.560
a
15.68
43.95
30
0
470
1319
0
0
0
0
11 D0
0.390
a
10.92
11.31
21
21
229
238
21
21
229.
238
w
13A-4ocs
0.143
s
4.00
2.55
630
595
2382
1515
558
523
2094
1331
Ij1A-c1om
1.270
s
35.56
34.77
15
30
533
522
15
15
533
522
IA-clom
1.270
s
35.56
, . 34.77
20
40
711
695
20
20
711
695
w
13A-4ocs
0.143
w
4.00
2.55
585
479
1920
_
1220
_
468
_
371
1487
945
1A-clom
1.270
w
35.56
91.12
15
0
533
1367
15
0
533
1367
IA-clomd
1.270
w
35.56
91.12
82
0
2902
7435
82
0
2902
7435
4A5-2ob
0.560
w
15.68
43.95
9
0
141
396
0
0
0
0
C
1613-30ad
0.032
-
0.90
1.68
2391
2391
2142
4017
_
2060
2060
1846
3461
F
I
I
22A-tpl
0.989
-
27.69
0.00
2391
270
7477
0
2060
210
5815
0
6
c) AED excursion
0
-247
Envelope loss/gain
26692
28002
22051
24133
12Ia)
Infiltration
3532
946
2747
736
b) Room ventilation
0
0
0
0
131
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1
30224
28948
24798
24869
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
30224
28948
24798
24869
15
Duct loads
34%
54%
10351
15607
34%
54%
8493
13408
Total room load
40575
44556
33291
38277
Air required (cfm)
1900
1900
1559
1632
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� � wrightsoft26
` Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Jun-22 13:Page
1
�� C:1Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJS Front Door faces: N ge 1
- wrightsoft` Right-J® Worksheet Job:
Entire House Date: Jun 22, 2017
By:
QUICK CAL.CS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
NEW BEDROOM
NEW BATH
2
Exposed wall
31.0 ft
29.0 ft
3
Room height
9.0 ft heat/cool
9.0 ft heat/cool
4
Room dimensions
13.0 x 18.0 ft
1.0 x 97.0 ft
5
Room area
234.0 ftz
97.0 ftz
Ty
Construction
U-value
Or
HTM
Area (W)
Load
Area (ft')
Load
number
(Btuh/ftZ °F)
(Btuh/ft�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
13A-4ocs
6.143
n
4.00
2.55
162
156
626
398
72
72
288
183
1A-clom
1.270
n
35.56
34.77
0
0
0
0
0
0
0
0
4A5-2ob
0.560
n
15.68
16.16
6
0
88
90
0
0
0
0
13A-4ocs
0.143
a
4.00
2.55
117
87
348
221
0
0
0
0
11
IA-clom
1.270
a
35.56
91.12
0
0
0
0
0
0
0
0
1A-c1am
1.270
a
35.56
91.12
0
0
0
0
0
0
0
0
4A5-2ob
0.560
a
15.68
43.95
30
0
470
1319
0
0
0
0
D
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W
13A4ocs
0.143
s
4.00
2.55
0
0
0
0
72
72
288
183
IA-clom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
1A-c1om
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
W'
13A4ocs
0.143
w
4.00
2.55
0
0
0
0
117
108
432
275
1A-clom
1.270
w
35.56
91.12
0
0
0
0
0
0
0
0
1A-clomd
1.270
w
35.56
91.12
0
0
0
0
0
0
0
0
4A5-2ob
0.560
w
15.68
43.95
0
0
0
0
9
0
141
396
C
16B-30ad
0.032
-
0.90
1.68
234
234
210
393
97
97
87
163
F
22A-tDl
0.989
-
27.69
0.00
234
31
858
0
97
29
803
0
61
c) AED excursion I
I
86
161
CEnvelope Toss/gain I
2601
2508
2040
1361
121 a) Infiltration
405
109
379
102
b) Room ventilation
0
0
0
0
131 Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
F-, Subtotal (lines 6 to 13)
3006
2617
2419
1463
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14 Subtotal
3006
2617
2419
1463
15 Duct loads
34%
54%
1030
1411
34%
54%
829
789
Total room load
I
4036
4027
3248
2252
Air required (cfm)
189
172
152
96
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
wrigF�tsoft' 2017-Jun-22 13:26:58
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N
-- wrightsoft® Duct System Summary
Entire blouse
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project• •
For: METREE RESIDENCE
3605 S. INDAIN RIVER DRIVE, FT. PIERCE, FL
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H 20
0.431
in/ 100ft
1900
cfm
Job:
Date: Jun 22, 2017
By:
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.431
in/100ft
1900
cfm
Total effective length (TEL) 116 ft
S,upplyBranch Detail Table
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
EXISTING HOUSE-1
c 38277
1559
1632
0
0
Ox0
VIFx
0
0
NEW BATH
h 3248
152
96
0.431
6.0
Ox0
VIFx
21.1
95.0
NEW BEDROOM
h 4036
189
172
0.442
8.0
Ox 0
VIFx
18.0
95.0
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox 0
1900
1900
0
0
0
0
Ox 0
VIFx
ti + wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101
AM C:\Users\Quick Calcs\Documents\METREE ADDITION.rup Calc = MJ8 Front Door faces: N
2017-Jun-22 13:31:33
Page 1