Project Name: Heizler Residence
Project Address: 6401 South Indian River Drive, Fort Pierce, Florida 34939
Permit #: Occupancy Type: R-1 Construction Type: CMU
INSTRUCTIONS FOR USE:
_ • This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B C X D
4. Design Wind Velocity 160 mph X ASD LRFD' End Zone Width: 6 ft
5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: 0 ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +42.7, -67.a Zone 2: *42.7, -11e.2 Zone 3: +42.7,-232.5 Zone 4: +44.5, -48.3 Zone 5 +44.5, -59.6 Garage: +37.9, -46.3
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: NSA PSF
Dock: NSA PSF Deck: N/A PSF Stairs: NSA PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Michael A. Kalajian 60133
Print Name Cert # & Co. Cert Auth.
MK Structural Engineering Inc.
587 W. Eau Gallie Blvd., Melbourne, Florida 32935