NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/nera
Southeastern Metals Manufacturing Co., Inc.
11801 Industry Drive
Jacksonville, FL. 32218
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 5-V Crimp Metal Roofing Panel System
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA #07-0815.06 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0714.08
MIAMI-DADe CO Expiration Date: 11/08/16
Approval Date: 06/14/12
Page 1 of 5
ROOFING SYSTEM APPROVAL
Catew : Roofing
Sub-Catetiory: Non -Structural Metal Roofing
Material: Steel
Maximum Design Pressure: -180 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Specifications Product Description
5V Crimp Metal Roof Length: various TAS 125 Corrosion resistant, galvalume or
Panels Height : 7/16" galvanized performed, Kynar or
Width: 25 %Z" SuperL II coated, pre -finished,
(Coverage width: 24") metal panels.
Thickness: 0.0217
Yield Strength: Min.53ksi
MANUFACTURING LOCATION:
1. Jacksonville, FL.
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials
SEM-011-02-05
TAS-125
11/23/10
Technologies
PRI Construction Materials
SEM-011-02-07
ASTM E 8
05/07/12
Technologies
Farabaugh Engineering and
T270-07
TAS-100
08/24/07
Testing, Inc.
Farabaugh Engineering and
T166-07
TAS-100
04/15/07
Testing, Inc.
Force Engineering & Testing,
188-0331T-06A-C
TAS-125
02/26/07
Inc.
Hurricane Test Laboratory, LLC.
0041-0906-07
TAS-125
09/12/07
BASF
Accelerated Weathering
ASTM G 154
07/12/07
BASF
Salt Spray
ASTM B 117
07/12/07
NOA No.: 11-0714.08
Expiration Date: 11/08/16
Approval Date: 06/14/12
Page 2 of 5
APPROVED ASSEMBLIES:
System: 115V-Crimp" Metal Panels
Deck Type: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank.
Slope Range: 2": 12" or greater
Maximum Uplift See Table A Below
Pressure:
Deck Attachment:
In accordance with applicable building code, but in no case it shall be less than 8d annular
ring shank nails spaced at 6" o.c. In re -roofing, where deck is less than 19/32" thick (minimum
1'/32") the above attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1-1/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Valleys:
Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with current published installation instructions and details in Southeastern Metal
Manufacturing Metal Roofing Installation Manual.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within the
assembly. See Limitation 4 1.
Metal Panels and
Install the "5V-Crimp Panels" and accessories in compliance with the current published
Accessories:
installation instructions and details in Southeastern Metals Manufacturing Company's
Installation Manual. Flashings, penetrations, valley construction and other details shall be
constructed in compliance with Roofing Application Standard RAS133.
1. At the eave, rake, and ridge, fasteners shall be located not more than 3" away from the
panel end.
2. The leading side edge of the panel should be the side with the anti -siphon groove; each
panel side will overlap this channel to provide a capillary brake.
3. The panels shall be fastened with metal roofing sealing washer screws with dimensions as
listed below in Table A, in the crown of the inverted V ribs as shown in the details herein.
4. The panel's width fasteners shall be spaced at 11 ''/z" to the center rib, Then 12 ''/z" to the
next, perpendicular to the slope, through the overlapping panel. The flat area of the panel
as shown in the details herein.
5. The panels fastening pattern at the interior of the panel, shall be in rows spaced as listed in..
Table A below, running parallel to the slope of the roof.
Table A
Maximum Design Pressure
Field
Perimeter and Corner'
Perimeter and Corner'
Maximum Design Pressure
-67.25 psf.
-154.75 psf
-180 psf
Fastener Type
#9 x 2"
#9 x 2"
410-14 x 2-1/2"
Maximum Fastener Spacing
16" o.c.
8" o.c.
8" o.c.
1. Extrapolation shall not be allowed
NOA No.: 11-0714.08
MIAMI•Dave CO TY Expiration Date: 11/08/16
Approval Date: 06/14/12
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product. be applicae to all roof p lt perimeters,
2. The maximum designed pressure analysis, herein shall
and corners). Neither rational nor extrapolation shall be permitted for enhanced fastening a enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels may be rolls formed in continuous s lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 1
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
MIAMI•DADE COUNTY
,"Mey 411
5. All products listed herein shall have a quality
assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative
NOA No.: 11-0714.08
Expiration Date: 11/08/16
MIAMI•DADE COUNTY Approval Date: 06/14/12
"' • ' Page 4 of 5
FL 14645.2-R2
C2010-2
3.27.15
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) 131.3 psf @ fastener spacing of 18" o.c.
149.6 psf @ fastener spacing of 12" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between
ribs)
At intermediate 4 fasteners per panel width. (4 located adjacent to ribs)
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
approved roofing materials directory or ASTM E1081UL790 report
from an accredited laboratory for fire ratings of this product.
FL 14645.2-R2
C2010-2
3.27.15
Page 3 of 3
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T235-07, Reporting Date 7/12/07
Project No. T172-08, Reporting Date 4/29/08
• 1 .
5V-CRIMP
5V-CRIMP
SEE DETAIL 1
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE.
L UNDERLAYMENT SHALL BE INSTALLED MINIMUM ATTACHMENT:
AS PER MANUFACTURER'S INSTALLATION 8d x 2.5" LONG RING SHANK NAIL
MIN. 2X_ WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS
TRUSS AT MAX. 24" O.C. SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT INTERMEDIATE LOCATIONS
SEE DETAIL 1
MIN. 2X— WOOD RAFTER/JOIST/
TRUSS AT MAX. 24" O.C.
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 24" O.C.
UNDERLAYMENT
DETAIL 1
24"
OR #8 x 2" LONG WOOD "SCREWS
SPACED ® 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT PANEL ENDS
TYPICAL PANEL INSTALLATION X-SECTION
5V-CRIMP
MIN 26 GA.
PLYWOOD
19/32" THICK (MIN.)
19/32" THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
FASTENER
SPACING
(IN)
PRESSURE
(PSF)
24
84.5
18
131.3
12
149.6
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
d
0 0
U N
U' uj N
Z ~0
Fr =)N
0 (n000
't 0
U)Y I
Ln
of 00
M� I
cn
N
x�
S�m
v u)o
OF