Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT EXTERIOR DOORSR W R W Building Consultants, Inc. ' B Consulting and Engineering Servicesfor the Building Industry P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 File COPY., Product Category Sub Category Manufacturer Product Name Plastpro Inc. Glazed Fiberglass Double Door Exterior Swinging. Exterior Door 5200 W CENTURY BLVD. Inswing / Outswing Doors Assemblies LOS ANGELES., CA 90045 "Impact" (440) 969-9773 Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (System ID 1998) for Plastpro Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: This product has been evaluated and is in compliance with the 5th Edition (2014) florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used. in. areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require.an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of -the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17184A require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-17184.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01391120 TAS 2017-94, 202-94 & TAS 203-94 Testing Evaluation Lab.,inc. Lyndon F. Schmidt, P.E TEL 01390454 ASTM E1886-05/E1996-06 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02 2.. Mlami-Dade NOA Materials Testing 14-0423.16 Saflex® PVB Interiayers (Eastman Chemical Company) 3. Drawing No. Prepared by Signed & Sealed by No. FL-17184.4 RW Building Consultants, Inc. (CA#9813) a4a�s��an_tte�r Lyndon F. Schmidt, P.E. 4. Calculations Prepared by ''� Signed &Sealed by Anchoring RW Building Consultants, Inc. (CA#9813)k "r, 99. Lyndon F. Schmidt, P.E. "b.,k lac' h34C.g. 5. Quality Assurance Certificate of Participation issued. by National Accreditation and Management Institute, certifying that Plastpro Inc. is manufacturing products 4: within a quality assurance that complies -with ISO/IEC 17020 ands wT t ` dry program Guide 53. �9 .� Lyndon F. Schmidt, P.E. y FL PE No. 43409 Sheet oft 4i27/2015 plastpro 5200 W. CENTURY BLVD. LOS ANGELES, CA 90045 GLAZED FIBERGLASS DOUBLE DOOR INSW►NG%OUTSWING IMPACT GENERAL NOTES 1. This product has been evaluated and is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level'D" and includes Wind Zone 4 as defined in ASTM El996 and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS SHEET # DESCRIPTION 1 ITYPICAL ELEVATION, DESIGN PRESSURES & GENERAL NOTES 2 PANEL DETAILS, COMPONENTS & GLAZING DETAIL 3 HORIZONTAL CROSS SECTIONS 4 VERTICAL CROSS SECTIONS 5 BUCK & FRAME ANCHORING 6 ASTRAGAL DETAILS 7 BILL OF MATERIALS & COMPONENTS I �74.00" MAX. O.A. FRAME WIDTH ----I X C7 J W is W0 w aw W X X i0 oZ • Z X3 `z 1- 00 Lq i co GLAZED DOUBLE DOOR MAX. O.A. GLASS DESIGN PRESSURE (PSF) SWING FRAME TYPE DIMENSION POSITIVE NEGATIVE 74.00" OUTSWING X +50.0 —50.0 96.50" G1 74.00" INSWING X +50.0 —50.0 98.00" "IT" M z nrn r i'• a�Z � n is O rn i°um rt0Ma � G\\\ N S. O n .. z C) •• Z oz. Ea 9mo. W V) 7 g L m Maas. scAL: N.T.S. DWG. BY. JK cwc By.. LFS FL-17184.4 IT 1 OF 7 R:\Clients\Plsstpro, Inc PERMANENT\Florida Product Approvals\FL-17184\C • Drawings\Current\FL-17184.3-S.dwg, 2A 10" MAX'. O.C. (TYP,) -� Ln p 4 r (n W p r D y m ND- D Z m � ® r D 6 .2" MAX.. D.L.O. HEIGHT 95.25" MAX. PANEL HEIGHT 1.742" z "' m nT (3 o m 5: ii ---1 1.584" x N � on m Lim N. Z = .O in o Ell Z O < $ G) —: . ;0 - Ln < z rrn z m Apt' my F r rrT v m o p o N v' N N 20.000" rA cn 5,500" w cn r- o � c� m � N D r= N W �F y. to q� n V G) y O, W Z R9 2 n No. 43409 A PLASTPRO INC. Lyndon K schinidt �tf�p .:L......� \mot INa o FIBERGLASS DOOR P.E. No; 43409 V a mPART OR ASSEMBLY: BUILDING CONSULTANTS, INC. R lq,- 1 04 22 15 UPDATE 70 STN ED. 2014) FHC" �BY P.O. Box 230, Valrico, FL 33595 v d+ N NO DATE PANEL DETAILS, COMPONENT$ Phone No.: 813,859.9197 REVISIONS &GLAZING DETAIL FSPE C.A. No. 9813 to P.O 1.2 M. W. ae,�o,..o. ce.,,ae�roHrs rtie. Wilents\Plastpro, Inc PERMANENWIorida. Product Approvals\FL-17184\C - Drawings\Current\FL-17184.3-S.dwg, 3A m ut1 O � /y� o '! S S N N b e.lbmbbn�. a-m A CSI 2�2' i m 4, ON v aeft vd�+ CD � Qi {a 3a •p N Q m Iwm W W W N IIAA Ip�' O W A N o m z r p. C) O !n r" W t7 H z N N W W W � N z Z N W a� a Co x O m ?< c: U) w e C. l 1 o z a' a. `,�• , Qua. z Z m m C). �o D to _ W a r- 7z z O Ln mx ti rA-^ w In W N r m U n O Z 2 • as o .<�i. ,. .`�Po • vA 1�t111116L1�i �i Lz f No.43409 fil PRODUCT: DooumentD Proynnd W., Lyndon F..Schmidt GRIDw *tom r't- PLASTPRO INC. FIBERGLASS DOOR P.E. No. 43409 �aS � PART OR ASSEMBLY: r ~ .� 0 /r BUILDING CONSULTANTS, INC. 1''04 2 15 UPDATE i0 5iH ED. 2014 F8C JK ( p n x \ w HORIZONTAL GROSS SEC710N5 tl1i P.O: Box 230 Valriico; FL 33696 +++ N0. DATE BY I� +' Phone No.: B13.659.9197 REVISIONS FBPE C.A. No. 9813 0 201.2. R.W. SU1901NC CCNHNLYANTB INC. l R:\OientsjPlaslprp,.Lnc PERMANFNT\Florida Product.Appiovala\FL-17184\C - Oraivings\Euhent\FL-17184.3-S.dwg, 4.4 1 /4" MAX. SHIM SPACE. (TYP,) 0.15' z CTR-SW e . to TYPICAL v ,° y • , , 9 �: O a 0 �• •. f�/1 .. ' �• W N ' ° UI ° Z Z a x x ' b 1 /4" MAX, I Iv SHIM SPACE z n n O Z• .o x. .v • . ape eo C \ ('1 Z v to UI a..•>. ....e �• m a G En A C : °. .Z >a a B . C V . .. • 'V ° m t7 O ,�l •;acm C'O�''�I Z pf No.43409 $ .PRODUCT: Doaumenb Proparod9Y: �� �ORfO�.•' ���� ro PLASTPRO FIBERGLASS INC. DOOR Ea n F43409 1dt••.... Z ��/lllllltll�� PART OR ASSEMBM pa -i //� /r t7A/ BUILDING CONSULTANTS, INC. 7 ,04/22 15 UPDATE TO 5TH ED. 2014).F13C JK p � . 0 w VERTICAL CROSS SECTIONS d l�u Yy� p,0. Box 230. Valrteo. FL.33595 NO DATE BY phone No.: 813.659.9197 FBPE C.A. No. 9813 REVISIONS 0 2Q 72'R-W. SUILOWa l3w4VULTANT9:INC. M016nts\Plastpro, Ind PERMANENT\Plorida:Product Approvals\FL-17184\C- D`swings\Corrdnt\FL-171843-S.dw4,6A 0 o Z 012 • 3.5" 11.25 —19.375" — 21.375" 31,875" 40.8.75" 43,875" a O O e' 00 O v b n 0.573" 0 T m to z o ea .� 0 0 rn w c� 0; 4-T JII -0.050" o cl. -•-I - 00.314" N ID --I O� U1 N O o-Itn� "o' $ 0 cxr00 0 0 a v tn. la14 �p00 Z o (A =NQ ® 20 12 R. W. 13UILCING CONSULTANT&INO. 31.875" 43.875" o I" — 2.880" -0-.i u D N Y r O O O N SCHA Na. 43409 PLASTPRG INC. Lyndon F. Schmidt 4S� �ei�.Z� .' FIBERGLASS DOOR P.E. Na. 43409 qS'0 M" ; SEMBI:Y:BUILDING CONSULTANTS, INC. A5TRAGAL DETAILS d I�YU P.O. Box 230• Valrlca• FL 33595 PMna No.: 813.659.9197