HomeMy WebLinkAboutHVAC LOADS*t: "u 0 BAYLOR MANOR ST. LUCIE COUNTY 4 PREPARED BY:.:; FRANK DELAPORTE RESIDENTIAW LIGHT COMMERCIAL HVAC LVAV CLIENT INFORMATION: NAME: MERCEDES HOMES ADDRESS: CITY, STATE: FORT PIERCE TOTAL BUILDING LOADS: PROJECT: CLIENT: DATE: DESIGNER: BAYLOR MANOR MERCEDES HOMES OCT 5,1997 FRANK DELAPORTE ------------------------------------------------------------------------------ BLDG. LOAD AREA SEN. LAT. + 'SEN. = TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN ------------------------------------------------------------------------------ 1-B WIND. CLEAR GLASS TIM FRAME 97 3,041 0 4,553 4,553 8-B GLS DOOR SGL CLR GLS TIM FR 40 1,254 0 1,112 1,112 13-C PART R-11 +-1/2" GYPSUM(R-0.5) 243 328 0 328 328 14-B WALL 8" OR 12" BLOCK + R-$ 978 4,227 0 2,295. 2,295 11-C DOOR METAL POLYSTYRENE CORE 20 282 0 222 222 16-D CEILING R-19 INSULATION 1,462 2,325 0 2,790 2,790 22-A SLAB ON GRADE NO EDGE INSUL 181 4,400 0 0 0 ------------------------------------------------------------------------------ SUBTOTALS FOR STRUCTURE: 3,021 15,857 0 11,306 11,300 PEO;DLE 6 0 1,380 1,800 3,180 APPLIANCES 0 0 0 1,200 1,200 .DUCTWORK 0 0 0 0 0 INFILTRATION W.CFM: 173.6 S.CFM: 86.8 0 5,730 3,660 1,528 5,188 VENTILATION W.CFM: 65.1 S.CFM: 65.1 0 2,149 2,745 1,146 3,891 ------------------------------------------------------------------------------ SENSIBLE GAIN TOTAL 16,974 TEMP. SWING MULTIPLIER X 1.10 BUILDING LOAD TOTALS 23,736 7,785 18,671 26,456 SUPPLY CFM AT 20 DEG DT: 791 CFM PER SQUARE FOOT: 0.541 SQUARE FT. OF ROOM AREA: 1,462 SQUARE FOOT PER TON: 663.139 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 23.736 MBH TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2.205 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. *** JENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* VERO BEACH, FL 32960 BAYLOR MANOR OCT 5,1997 PAGE 2 ************************ TOTAL ZONE LOADS FOR ZONE # 1 *********************** --------------------- ------- BLDG. LOAD AREA SEN. LAT. + SEN. =TOTAL DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN -------------------------------------------- 1-B WIND. CLEAR GLASS TIM FRAME 97 - 3,041 0 4,553 4,553 8-B GLS DOOR SGL CLR GLS TIM FR 40 -1,254 0 1,112 1,112 13-C PART R-11 + 1/2" GYPSUM(R-0.5) 243 328 0 328 328 14-B WALL 8" OR 12". BLOCK + R-5 978 4,227 0 2,295 2,295 11-C DOOR METAL POLYSTYRENE CORE 20 282 0 222 222 16-D CEILING R-19 INSULATION 1,462 2,325 0 2,790 2,790 22-A SLAB ON GRADE NO EDGE INSUL 181 4,400 0 0 0 ---------------------------- - SUBTOTALS FOR STRUCTURE: 3,021 15,857 0 11,300 11,300 PEOPLE 6 0 1,380 1,800 3,180 APPLIANCES 0 0 0 1,200 1,200 DUCTWORK 0 0 0 0 0 INFILTRATION W.CFM: 173.6 S.CFM: 86.8 0 5,730 3,660 1,528 5,188 VENTILATION W.CFM: 65.1 S.CFM: 65.1 0 2,149 2,745 1,146 3,891 SENSIBLE GAIN TOTAL 16,974 TEMP. SWING MULTIPLIER X 1.10 BUILDING LOAD TOTALS ------------------------------------------------------------------------------ 231736 7,785 18,671 26,456 SUPPLY CFM AT 20 DEG DT: 791 CFM PER SQUARE FOOT: 0.541 SQUARE FT. OF ROOM AREA: 1,462 SQUARE -FOOT PER TON: 663.101 TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 23.736 MBE TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2.205 TONS CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J. ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY. BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS. ** ANTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* VERO BEACH, FL 32960 BAYLOR MANOR OCT 5,1997 PAGE 3 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 1. MASTER BEDROOM 15.9 WID X 13.1 LEN = 208 SF CEIL.HT = 8.0 S -WALL-14B 8 X 13.1 85 0.144 4.3 367 2.3 0 200 E -WALL-14B 8 X 15.9 127 0.144 4.3 549 2.3 0 298 S-GLAS-1B 1-P 0-1 S-1 100%S 20 1.045 31.4 627 27.8 0 556 CEIL-16D LIGHT 13.1 X 15.9 208 0.053 1.6 331 1.9 0 397 FLOOR-22A 29 FT 29 0.810 24.3 705 0.0 0 0 INFIL. W: 22.1 S: 11.1 20 36.5 730 9.7 466 195 PEOPLE 2 230 300 460 600 SENSIBLE LOAD SUBTOTAL: 2,246 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 3,309 926 .2,471 2. MASTER BATH 8.7 WID X 13.1 LEN = 114 SF CEIL.HT = 8.0 E -WALL-14B 8 X 8.7 58 0.144. 4.3 251 2.3 0 136 E-GLAS-lB 1-P 0-1 S-1 O%S 12 1.045 31.4 376 85.8 0 1,030 CEIL-16D LIGHT 13.1 X 8.7 114 0.053 1.6 181 1.9 0 218 FLOORR-22A 8.7 FT 9 0.810 24.3 219 0.0 0 0 INFIL. W: 13.3 S: 6.6 12 36.5 438 9.7 280 117 SENSIBLE LOAD SUBTOTAL: 1,501 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 1,465 280 1,651 3. LIVING ROOM 12.8 WID X 12.8 LEN = 164 SF CEIL.HT = 10.0 E -WALL-14B 10 X 12.8 128 0.144 4.3 553 2.3 0 300 N -WALL-14B 10 X 12.8 108 0.144 4.3 467 2.3 0 253 N-GLAS-IB 1-P 0-1 S-1 OWS 20 1.045 31.4 627 27.8 0 556 CEIL-16D LIGHT 12.8 X 12.8 164 0.053 1.6 261 1.9 0 313 FLOOR-22A 25.6 FT 26 0.810 24.3 632 0.0 0 0 INFIL. W: 22.1 S: 11.1 20 36.5 730 9.7 466 195 SENSIBLE LOAD SUBTOTAL: 1,617 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 3,270 466 1,779 * IAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * * VERO BEACH, FL 32960 BAYLOR MANOR OCT 5,1997 PAGE 4 **************************** DETAILED ROOM LOADS'***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION --------------------------- ------ QUAN VAL. ------ HTM ------------ LOSS HTM ----- GAIN ------ GAIN ------- 4. FOYER 8.0 WID X 8.0 LEN = 64 SF CEIL.HT = 10.0 N -WALL-14B 10 X 8 55 0.144 4.3 238 2.3 0 129 W -PART-13C 10 X 8 80 0.090 1.4 108 1.4 0 108 N -DOOR-11C 6.7 X 3 20 0.470 14.1 282 11.1 0 222 N-GLAS-1B 1-P 0-1 S-1 OAS 5 1.045 31.4 157 27.8 0 139 CEIL-16D LIGHT 8 X 8 64 0.053 1.6 102 1.9 0 122 FLOOR-22A 8 FT 8 0.810 24.3 194 0.0 0 0 INFIL. W: 27.6 S: 13.8 25 36.5 912 9.7 583 243 SENSIBLE LOAD SUBTOTAL: 963 TEMPERATURE SWING MULTIPLIER: X I A00 ROOM TOTALS 1,993 583 1,059 5. LAUNDRY ROOM 6.0 WID X 6.0 LEN = 36 SF CEIL.HT = 8.0 W -PART-13C 8 X 6 48 0.090 1.4 65 1.4 0 65 CEIL-16D.LIGHT 6 X 6 36 0.053 1.6 57 1.9 0 69 FLOOR-22A 6 FT 6 0.810 24.3 146 0.0 0 0 INFIL. W: 0.0 S: 0.0 0 36.5 0 9.7 0 0 SENSIBLE LOAD SUBTOTAL: 134 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 268 0 147 6. FAMILY 15.6 WID X 14.1 LEN = 220 SF' CEIL.HT = 10.0 S -WALL-14B 10 X 14.1 101 0.144 4.3 436 2.3 0 237 S-G.DR-8B 1-P 0-1 S-1 100$S 40 1.045 31.4 1,254 27.8 0 1,112 CEIL-16D LIGHT 14.1 X 15.6 220 0.053 1.6 350 1.9 0 420 FLOOR-22A 14.1 FT 14 0.810 24.3 340 0.0 0 0 INFIL. W: 44.2 S: 22.1 40 36.5 1,460 9.7 933 389 SENSIBLE LOAD SUBTOTAL: 2,158 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 3,840 933 2,374 ** ENTIAL AND LIGHT-COM14ERCIAL HVAC LOADS BY ELITE SOFTWARE ******* * 1P. * VERO BEACH, FL 32960 BAYLOR MANOR OCT 5,1997 PAGE 5 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION QUAN VAL. HTM LOSS HTM GAIN GAIN 7. BEDROOM 3 13.4 WID X 12.0 LEN = 161 SF CEIL.HT = 8.0 S -WALL-14B 8 X 12 76 0.144 4.3 328 2.3 0 178 W -WALL-14B 8 X 10.8 86 0.144 4.3 372 2.3 0 202 S-GLAS-1B 1-P 0-1 S-1 100*S 20 1.045 31.4 627 27.8 0 556 CEIL-16D LIGHT 12 X 13.4 161 0.053 1.6 256 1.9 0 307 FLOOR-22A 22.8 FT 23 0.810 24.3 559 0.0 0 0 INFIL. W: 22.1 S: 11.1 20 36.5 730 9.7 466 195 PEOPLE 2 230 300 460 600 SENSIBLE LOAD SUBTOTAL: 2,038 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 2,872 926 2,242 8. BATH 12.0 WID X 5.4 LEN = 65 SF CEIL.HT = 8.0 W -WALL-14B 8 X 5.4 43 0.144 4.3 186 2.3 0 101 CErL-16D LIGHT 5.4 X 12 65 0.053 1.6 103 .1.9 0 124 FLOOR-22A 5.4 FT 5 0.610 24.3 122 0.0 0 0 INFIL. W: 0.0 S; 0.0 0 36.5 0 9.7 0 0 SENSIBLE LOAD SUBTOTAL: 225 TEMPERATURE SWING MULTIPLIER: -X 1.100 ROOM TOTALS 411 0 - 248 9. BEDROOM 2 14.4 WID X 11.4 LEN = 164 SF CEIL.HT = 8.0 N -PART-13C 8 X 14.4 115 0.090 1.4 155 1.4 0 155 W -WALL-14B 8 X 11.4 71 0.144 4.3 307 2.3 0 167 W-GLAS-1B 1-P 0-1 S-1-0*S 20 1.045 31.4 627 85.8 0 1,716 CEIL-16D LIGHT 14.4 X 11.4 164 0.053 1.6 261 1.9 0 313 FLOOR-22A 25.8 FT 26 0.810 24.3 632 0.0 0 0 INFIL. W: 22.1 S: 11.1 20 36.5 730 9.7 466 195 PEOPLE 2 230 300 460 600 SENSIBLE LOAD SUBTOTAL: 3,146 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 2,712 926 3,461 )ENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE ******* 2P. * VERO BEACH, FL 32960 _ BAYLOR MANOR OCT 5,1997 PAGE 6 **************************** DETAILED ROOM LOADS ***************************** ITEM AREA -U- HTG SEN. CLG LAT. SEN. DESCRIPTION --------------------------- ------ QUAN VAL. ------ HTM ------------ LOSS HTM ----- GAIN ------ GAIN ------- 10. KITCHEN 12.0 WID X 18.0 LEN = 216 SF CEIL.HT = 10.0 CEIL-16D LIGHT 18 X 12 216 0.053 1.6 343 1.9 0 412 FLOOR-22A 30 FT 30 0.810 24.3 729 0.0 0 0 INFIL. W: 0.0 S: 0.0 0 36.5 0 9.7 0 0 APPLIANCES 0 1,200 SENSIBLE LOAD SUBTOTAL: 1,612 TEMPERATURE SWING MULTIPLIER: X 1.100 ROOM TOTALS 1,072 0 1,773 11. CLOSET MST BEDROOM E -WALL-14B 8 X 5 CEIL-16D LIGHT 5 X 10 FLOOR-22A 5 FT INFIL. W: 0.0 S: 0.0 SENSIBLE LOAD SUBTOTAL: TEMPERATURE SWING MULTIPLIER: ROOM TOTALS 10.0 WID x 5.0 LEN = 50 SF CEIL.HT = 8.0 40 0.144 4.3 173 2.3 0 94 50 0.053 1.6 80 1.9 0 95 5 0.810 24.3 122 0.0 0 0 0 36.5 0 9.7 0 0 189 x 1.100 375 0 208 ATIAL AND LIGHT COMMEf2CIAL HVAC LOADS BY ELITE SOFTWARE ******* j * VERO BEACH, FL 32960 BAYLOR MANOR OCT 5,1997 PAGE 7 ZONE # 1 ROOM LOAD SUMMARY ************************* ------ - - - - -- - - - ------ RM ROOM - --------- AREA --------------- ------ HEATING --------- ------ -� -------------- - - ------ COOLING ------ - - -- NO. DESCRIPTION (SF) BTUH $ TOT CFM BTUH- %- TOT CFM ------------------------------------------------------------------------------ 1. MASTER BEDROOM 208 3,309 15.3 43 2,471 14.2 112 2. MASTER BATH 114 1,465 6.8 19 1,651 9.5 75 3. LIVING ROOM 164 3,270 15.1 42 1,779 10.2 81 4. FOYER 64 1,993 9.2 26 1,059 6.1 48 5. LAUNDRY ROOM 36 268 1.2 3 147 0.8 7 6. FAMILY 220 3,840 17.8 50 2,374 13.6 108 7. BEDROOM 3 161 2,872 13.3 37 2,242 12.9 102 8. BATH 65 411 1.9 5 248 1.4 11 ,9. BEDROOM 2 164 2,712 12.6 35 3,461 19.9 157 10. KITCHEN 216 1,072 5.0 14 1,773 10.2 81 11. CLOSET MST BEDROOM 50 .375 . 1.7 5 208 1.2 9 ---------------------- ------------------ ZONE SUBTOTAL 1,462 21,587 100.0 280 17,412 100.0 791 VENTILATION 2,149 1,146 LATENT GAIN 7,785 ZONE TOTALS 23,736 26,343 2.195 TONS EQUIPMENT DATA HEATING SYSTEM DESCRIPTION COOLING SYSTEM DESCRIPTION i BRAND: MODEL: FB4ANF030 3SYCCO30 TYPE: CARRIER CARRIER DESCRIPTION: AIR HANDLER CONDENSING UNIT EFFICIENCY: 10 SEER HSPF 7.20 CAPACITY: 29,000 28,200 BLOWER CFM: COMMENT: