October 15, 1997
Mercedes Homes, Inc.
1640 S.W. Biltmore Street
Port St. Lucie, Fl 34984
Subject : Truss Engineering Specifications
Job ID : PSL-1207
Location% BAYLOR MANOR `D'
Please find attached:
1. Truss Run Sheet(s)
2. Truss Placement Diagram(s)
3. Reaction/Uplift Summary Sheet(s)
4. 35 Truss Engineering Specification(s)
900 COX ROAD
COCOA, FL 32926
(407) 633-7511
FAX 633-7544
This cover sheet will serve as a banket certification for all the
attached items under chapter 2111-23, section 2111-23.002 of the Florida
Department of Professional Regulation. The items are enclosed in alsealed
binder which inhibits tampering. Should you have any questions concerning
this engineering please contact me at 407-633-7511.
Steve Kastner
Professional Engineer
ProductionLISfi
900 COX ROAD
MERCEDES HOMES
Job Number.
COCOA, FL 32926
_ _
PhonWindspeegSL1207
BAYLOR MANOR V
Page: 1
Project ID: psl120797
Model: BAYLOR V Lot No:
C n a
Site:
Office:
Deliver TO:
Account :
Designer: WAYNE
Name:
Salesperson: MER
Phone:
BLOCK
110 MPH WIND LOAD
37LB TOTAL LOAD
Profiler
Qty:
Truss Id:
Span:
Truss Type:
Slope:
LOH
ROH
Built By:
2 Pcs-Ea 16 Total
8
13J2
2-0-0
ROOFTRUSS
6.00
1-0-0
0-0-0
8 lbs. each
0.00
Webs
2 Pcs-Ea 16 Total
8
13J4
4-0-0
ROOFTRUSS
6.00
1-0-0
0-0-0
14 lbs. each
0.00
Webs
2 Pcs-Ea 6 Total
4
8.16
6-0-0
ROOFTRUSS
6.00
1-0-0
0-0-0
20 lbs. each
0.00
Webs
5 Pcs-Ea 10 Total
2
CJ6
8-5-13
ROOFTRUSS
4.24
1-5-0
0-0-0
39 lbs. each
0.00
4 Webs
6 Pcs-Ea 12 Total
2
CJ8
11-3-12
ROOF TRUSS
4.24
1-5-0
0-0-0
56 lbs. each
0.00
6 Webs
(2) 2-Ply
5 Pcs-Ea 20 Total
4
FG1
8-0-0
ROOFTRUSS
0.00
0-0-0
0-0-0
15 lbs. each
3.00
8 Webs
25 Pcs-Ea 25 Total
1
H101 B
40 - 0- 0
ROOF TRUSS
6.00
1-0-0
1-0-0
231 lbs. each
0.00
17 Webs
11 Pcs-Ea 11 Total
1
H102
20-4-0
ROOFTRUSS
6.00
0-0-0
1-0-0
103 lbs. each
0.00
6 Webs
21 Pcs-Ea 21 Total
1
H121B
40-0-0
ROOFTRUSS
6.00
1-0-0
1-0-0
229 lbs. each
3.00
14 Webs
21 Pcs-Ea 21 Total
1
H141 B
40 - 0 - 0
ROOFTRUSS
6.00
1-0-0
1-0-0
232 lbs. each
0.00
13 Webs
23 Pcs-Ea 23 Total
1
H161 B
40 - 0- 0
ROOFTRUSS
6.00
1-0-0
1-0-0
229 lbs. each
3.00
13 Webs
26 Pcs-Ea 26 Total
1
H181B
40-0-0
ROOF TRUSS
6.00
1-0-0
1-0-0
237 lbs. each
3.00
14 Webs
11 Pcs-Ea 11 Total
1
H62
20 - 8 - 0
ROOFTRUSS
6.00
1-0-0
1-0-0
103 lbs. each
0.00
7 Webs
(1) 3-Ply
32 Pcs-Ea 96 Total
3
H81
40 - 0 - 0
ROOF TRUSS
6.00
1-0-0
1-0-0
'295 lbs. each
2X4/2X6
0.00
69 Webs
(1) 3-Ply
29 Pcs-Ea 87 Total
3
H81S
40 - 0 - 0
ROOFTRUSS
6.00
1-0 - 0
1-0-0
276 lbs. each
2X4/2X6
3.00
60 Webs
10 Pcs-Ea 10 Total
1
H82
20 - 8 - 0
ROOFTRUSS
6.00
0-0-0
1-0-0
97 lbs. each
0.00
5 Webs
21 Pcs-Ea 21 Total
1
HS101A
40 - 0 - 0
ROOFTRUSS
6.00
1-0-0
1-0-0
215 lbs. each
3.00
13 Webs
19 PCs -Ea 19 Total
1
HS121
40 - 0 - 0
ROOFTRUSS
6.00
1-0-0
1-0-0
222 lbs. each
3.00
12 Webs
22 Pcs-Ea 22 Total
1
HS141
40 - 0 - 0
ROOFTRUSS
6.00
1-0-0
1-0-0
233 lbs. each
3.00
14 Webs
26 PCs -Ea 26 Total
1
HS161
40 - 0 - 0
ROOF TRUSS
6.00
1-0-0
1-0-0
244 lbs. each
3.00
18 Webs
SPACE COAST TRUSS, INC.
To:
900 COX ROAD
Production Lis
COCOA, FL 32926
MERCEDES HOMES
JUl
hone- 407-633--7611 FIX- _ _
BAYLOR MANOR V
Page: 2
Date: 10-14-1997
WindspeePSL-1207
Model: BAYLOR V Lot No:
Project ID: psl-1207
Contact:
Site:
Office:
Deliver To:
Account No:
Designer. WAYNE
Name:
Phone:
BLOCK
110 MPH WIND LOAD
Salesperson: MER
37LB TOTAL LOAD
Profile:
Qty:
Truss Id:
Span:
Truss Type:
Slope:
LOH
ROH
Built By:
31 Pcs-Ea 31 Total
1
HS181
40 - 0 - 0
ROOF TRUSS
6.00
1-0-0
1-0-0
259 lbs. each
3.00
20 Webs
2 Pcs-Ea 12 Total
6
J6
6-0-0
ROOF TRUSS
6.00
1-0-0
0-0-0
20 lbs. each
0.00
Webs
2 Pcs-Ea 12 Total
6
J8
8-0-0
ROOF TRUSS
6.00
1-0-0
0-0-0
27 lbs. each
0.00
Webs
(1) 2-Ply
5 Pcs-Ea 10 Total
2
JG8
8 - 0 - 0
ROOF TRUSS
6.00
0-0-0
0-0-0
45 lbs. each
2X4/2X6
0.00
6 Webs
2 Pcs-Ea 4 Total
2
SBJ2
2-0-0
ROOF TRUSS
6.00
1-0-0
0-0-0
8 lbs. each
3.00
Webs
2 Pcs-Ea 4 Total
2
S1BJ4_
4= 0 = 0 --
ROOF TRUSS
6.00
1-0-0
0-0-0
14 lbs. each
3.00
Webs
2 Pcs-Ea 4 Total
2
SBJ6
6-0-0
ROOF TRUSS
6.00
1-0-0
0-0-0
21 lbs. each
3.00
Webs
6 Pcs-Ea 6 Total
1
SCJ8
11 - 2 - 4
ROOF TRUSS
4.25
1-5-0
0-0-0
51 lbs. each
2.15
3 Webs
3 Pcs-Ea 27 Total
9
SJ8
8-0-0
ROOF TRUSS
6.00
1-0-0
0-0-0
31 lbs. each
3.00
9 Webs
21 Pcs-Ea 42 Total
2
Ti
40 - 0 - 0
ROOF TRUSS
6.00
1-0-0
1-0-0
226 lbs. each
3.00
22 Webs
6 Pcs-Ea 24 Total
4
T16
72 lbs. each
16 - 0 - 0
ROOF TRUSS
6.00
0.00
1-0-0
1-0-0
12 Webs
14 Pcs-Ea 14 Total
1
T16GE
87 lbs. each
16 - 0 - 0
ROOF TRUSS
6.00
0.00
1-0-0
1-0-0
11 Webs
8 Pcs-Ea 16 Total
2
T2S
20 - 4 - 0
ROOF TRUSS
6.00
0-0-0
1-0-0
93 lbs. each
0.00
8 Webs
c0-8-0
c0-8-0
4 Pcs-Ea 8 Total
2
T3
32 lbs. each
7-0-0
KINGPOST
6.00
0.00
1-0-0
1-0-0
2 Webs
4 Pcs-Ea 4 Total
1
T3GE
28 lbs. each
7-0-0
KINGPOST
6.00
0.00
1-0-0
1-0-0
1 Webs
4 O - O - O
11 6 - O - O
0
0
I III I I I
2 0 8 O 8 4- Ol 2 8 O
V I ! 1 V L V V! 1 V I I I I V V V
900 COX ROAD Name: MERCEDES Description: BAYLOR MANOR 'D' VA
COCOA, FLORIDA 32922 HOMES
Name: PSL-1207 J°b: PSL-1207
Address:
J� 'lV i. L�LJf"iV' 1 1\VVV, IIV�
%.7
I O ,_� f
.= eactior� ummar
cox ROAD
Job Number:
COCOA, FL 32926
MERCEDES HOMES
_ _ _
BAYLOR MANOR V
Page: 1
Date: 997
WindspeeRSL-1207
Model: BAYLOR U Lot No:
psi-12 7
Project ID: psi-1207
Contact:
Site:
Office:
-
Deliver TO:
Account No:
Designer: WAYNE
Name:
Phone:
BLOCK
110 MPH WIND LOAD
Salesperson: MER
37LB TOTAL LOAD
Tentative Delivery
Dates
Profile:
Qty:
Truss Id:
Span:
Truss Type:
Slope:
Reactions:
Joint 2 Joint 3 Joint 4
8
B.12
2-0-0
ROOF TRUSS
6.00
144 lbs. 52 Ibs. 19 Ibs.
8 Ibs. each
0.00
-165 Ibs. -46 Ibs.
Joint 2 Joint 3 Joint 4
8
6.14
4-0-0
ROOFTRUSS
6.00
210 lbs. 102 Ibs. 37 Ibs.
14 Ibs. each
0.00
-183 lbs. -123 lbs.
Joint 2 Joint 3 Joint 4
• 4
BJ6
6-0-0
ROOFTRUSS
6.00
281 Ibs. 150 Ibs. 57 Ibs.
20 Ibs. each
0.00
-204 Ibs. -198 lbs.
Joint 2 Joint 4 Joint 5
2
CJ6
8 - 6 -13
ROOFTRUSS
4.24
804 lbs. 284 lbs. 603 lbs.
39 Ibs. each
0.00
-512 lbs. -252 Ibs. -294 lbs.
Joint 2 Joint 5 Joint 6
2
C.18
11 - 3 -12
ROOFTRUSS
4.24
464 lbs. 59 Ibs. 760 lbs.
56 Ibs. each
0.00
-430 Ibs. -28 Ibs. -499 Ibs.
(2) 2-Ply
Joint 3 Joint 5
4
FG1
8-0-0
ROOFTRUSS
0.00
452 lbs. 452 lbs.
15 Ibs. each
3.00
-244 lbs. -218 lbs.
Joint 12 Joint 2
1•
H101B
40 - 0 - 0
ROOFTRUSS
6.00
1531 lbs. 1531 Ibs.
231 lbs. each
0.60
-990 Ibs. -990 lbs.
Joint 1 Joint 6
1
H102
20 - 4 - 0
ROOFTRUSS
6.00
742 lbs. 805 lbs.
103 Ibs. each
0.00
-440 lbs. -560 Ibs.
Joint 2 Joint 9
1
H121 B
40 - 0 - 0
ROOFTRUSS
6.00
1531 lbs. 1531 lbs.
229 Ibs. each
3.00
-990 lbs. -990 lbs.
Joint 10 Joint 2
1.
H141 B
40 - 0 - 0
ROOFTRUSS
6.00
1531 lbs. 1631 lbs.
232 Ibs. each
0.00
-990 lbs. -990 lbs.
Joint 11 Joint 2
1
H161 B
40 - 0.0
ROOF TRUSS
6.00
1531 lbs. 1531 Ibs.
229 Ibs. each
3.00
-990 Ibs. -990 lbs.
Joint 13 Joint 2
1
H181B
40 - 0 - 0
ROOFTRUSS
6.00
1531 lbs. 1531 lbs.
237 lbs. each
3.00
-990 lbs. -990 Ibs.
Joint 2 Joint 8
1
H62
20 - 8 - 0
ROOFTRUSS
6.00
2262 lbs. 2262 Ibs.
103 lbs. each
0.00
-1208 Ibs. -1208 lbs.
(1) 3-Ply
Joint 17 Joint 2
3
H81
40 - 0 - 0
ROOF TRUSS
6.00
3393 Ibs. 3393 lbs.
295 lbs. each
2X4/2X6
0.00
-2297 lbs. -2297 lbs.
(1) 3-Ply
Joint 16 Joint 2
3
H81S
40 - 0 - 0
ROOFTRUSS
6.00
2383 Ibs. 3938 lbs.
276 Ibs. each
2X4/2X6
3.00
-1395 lbs. -2132 lbs.
Joint 1 Joint 6
1
H82
20 - 8 - 0
ROOFTRUSS
6.00
754 lbs. 816 lbs.
97 Ibs. each
0.00
-451 Ibs. -563 lbs.
Joint 10 Joint 16 Joint 2
1
HS101A
40 - 0 - 0
ROOF TRUSS
6.00
698 lbs. 1747 lbs. 659 lbs.
215 lbs. each
3.00
-536 lbs. -974 lbs. -500 lbs.
Joint 11 Joint 15 Joint 2
1
HS121
40 - 0 - 0
ROOFTRUSS
6.00
697 Ibs. 1779 Ibs. 647 Ibs.
222 Ibs. each
3.00
-540 lbs. -991 Ibs. -491 lbs.
Joint 10 Joint 14 Joint 2
1
HS141
40 - 0 - 0
ROOFTRUSS
6.00
702 lbs. 1798 lbs. 638 Ibs.
233 Ibs. each
3.00
-553 lbs. -991 Ibs. -492 lbs.
Joint 11 Joint 2
1
HS161
40 - 0 - 0
ROOF TRUSS
6.00
1531 lbs. 1531 Ibs.
244 Ibs. each
3.00
-990 lbs. -990 lbs.
SPACE COAST TRUSS, INC.
To:
900 COX ROAD
Reaction Summary
JU
COCOA, FL 32926
MERCEDES HOMES
_ _ _
BAYLOR MANOR U
Page: 2
Date: 10-14-1997
WindspeePSL-1207
Model: BAYLOR V Lot No:
Project ID: psl-1207
Contact:
Site:
office:
Deliver To:
Account
Designer:: WAYNE
Name:
Phone:
BLOCK
110 MPH WIND LOAD
Salesperson: MER
Fav
37LB TOTAL LOAD
Profile:
Qty:
Truss Id:
Span:
Truss Type:
Slope:
Reactions:
Joint 11 Joint 2
1
HS181
40 - 0 - 0
ROOF TRUSS
6.00
1531 lbs. 1531 lbs.
259 lbs. each
3.00
-990 lbs. -990 lbs.
Joint 2 Joint 3 Joint 4
6
J6
6-0-0
ROOF TRUSS
6.00
281 lbs. 156 lbs. 57 lbs.
20 lbs. each
0.00
-204 lbs. -198 lbs.
Joint 2 Joint 3 Joint 4
6
J8
8-0-0
ROOF TRUSS
6.00
353 lbs. 205 lbs. 77 lbs.
27 lbs. each
0.00
-229 lbs. -270 lbs.
(1) 2-Ply
Joint I Joint 4
2
JG8
8-0-0
ROOF TRUSS
6.00
1569 lbs. 1569 lbs.
45 lbs. each
2X4/2X6
0.00
-770 lbs. -896 lbs.
Joint 2 Joint 3 Joint 4
2
SBJ2
2-0-0
ROOF TRUSS
6.00
144 lbs. 52 lbs. 19 lbs.
8 lbs. each
3.00
-157lbs.---541bs.-- . - _ _
Joint 2 Joint 3 Joint 4
2
SBJ4
_ _
4-. 0 - 0
ROOF TRUSS
6.00
210 lbs. 102 lbs. 37 lbs.
14 lbs. each
3.00
-177 lbs. -128 lbs.
Joint 2 Joint 3 Joint 4
2
SBJ6
6-0-0
ROOF TRUSS
6.00
281 lbs. 156 lbs. 57 lbs.
21 lbs. each
3.00
-199 lbs. -203 lbs.
Joint 2 Joint 6 Joint 7
1
SCd8
11 - 2 - 4
ROOF TRUSS .
4.25
445 lbs. 81 lbs. 895 lbs.
51 lbs. each
2.15
-386 lbs. -177 lbs. -522 lbs.
Joint 2 Joint 4 Joint 5
9
SJ8
8-0-0
ROOF TRUSS
6.00
348 lbs. 51 lbs. 243 lbs.-
31 lbs. each
3.00
-222 lbs. -85 lbs. -175 lbs.
Joint 12 Joint 2
2
T1
40 - 0 - 0
ROOF TRUSS
6.00
1531 lbs. 1531 lbs.
226 lbs. each
3.00
-990 lbs. -990 lbs.
Joint 2 Joint 6
4
T16
16 - 0 - 0
ROOF TRUSS
6.00
643 lbs. 643 lbs.
72 lbs. each
0.00
-460 lbs. -460 lbs.
Joint 2 Joint 6
1
T16GE
16 - 0 - 0
ROOF TRUSS
6.00
643 lbs. 643 lbs.
87 lbs. each
0.00
-460 lbs. -460 lbs.
Joint 1 Joint 5
2
T2S
20 - 4 - 0
ROOF TRUSS
6.00
742 lbs. 803 lbs.
93 lbs. each
0.00
-443 lbs. -556 lbs.
Joint 2 Joint 4 -
2
T3
32 lbs. each
7-0-0
KINGPOST
6.00
0.00
310 lbs. 364 lbs.
-262 lbs. -262 lbs.
Joint 2 Joint 4 Joint 6
1
T3GE
7-0-0
KINGPOST
6.00
202 lbs. 256 lbs. 217 lbs.
28 lbs. each
0.00
-203 lbs. -203 lbs. -118 lbs.
AOL A. A& r v L Ask Y& 1•49k r L
Job
NSS
NSS Iype
wry
y�t$AYLUKMAN(JR'LU)',(U;YIV'KF-.5
PSL-1207
BJ2
ROOF TRUSS
8
1
rJn us es, nc. Lie age
-1-0-0 2-0-0
1-0.0 2.0.0
3
6.00 rrr
2K4=
2
1
2.0.0
2-0-0
LOADING (psf)
SPACING 2-0-0.
CSI`
DEFL (in) poc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.17
Vert(LL) n/a - n/a
M20 249/190
•TCDL 7.0
.Lumber Increase .1.25,
BC 0.03
Vert(TL) 0.01 1-2 >999
.BCLL 0.0
Rep Stress lncr YES:
WB 0.00
Horz(TL) --0.00 3 Na
BCDL 10.0
Code SBC/ANS195
(Matra)
Min Length / LL deft = 999
Weight 8 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 1-10-14 on
center bracing.
REACTIONS (Ib/size) 3=36/0-2-0, 2=144/0-8-0, 4=19/0-3-8
Max Harz 2=116(load case 4)
Max Upiift3=-45(load case 2), 2=164(load case 4)
Max Grav3=52(load case 5), 2=1440oad case 1). 4=190oad case 1)
FORCES (lb)
TOP CHORD 1-2=23, 2-3 =32
BOT CHORD 2.4=0
NOTES
.1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead road and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed town The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) ProvWe mechanical connection (by others) of truss to bearing plate at joint(s) 3.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 45 lb uplift atjoint 3 and 164 lb uplift at Joint 2.
5) This truss has been designed with ANSUTPI 1-1995 criteria.
O ,
NSS
Nss ype
y ,
PSL-1207
BJ4
ROOF TRUSS
8
1
milel(Industnes,inc. ue age
4-0.0 --
1-0-0 4.0.0
3
6.00 rM
2k4=
t
441.0
44W
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.31
Vert(LL n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.11
Vert(TL3 0.03' 1-2 >411
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANS195
(Matrix)
Min Length / LL deg = 999
Weight 14 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 3-8-8 on
center bracing.
REACTIONS (Ib/size) 3=92/0-2-0, 2=210/0-8-0, 4=37/0-3-8
Max Harz 2=178(load case 4)
Max Uplrft3=122(load case 2), 2=182(load case 4)
Max Grav3=102(load case 5), 2=210(load case 1), 4=37(load case 1)
FORCES (lb)
TOP CHORD 1-2=23, 2-3=34
BOT CHORD 2-4=0
NOTES
1) This truss has been designed for the wind roads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead road and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanirne, on an occupancy category I, condition I
enclosed building; of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. if
porches exist, they are not exposed to wind. The lumber DOL increase Is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) Provide mechanical connection (by others) of truss to.bearing plate at joint(s) 3.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 122 lb uplift at joint 3 and 182 lb uplift at joint 2.
5) This.truss has been designed with ANSI/TPI 1-1995 criteria.
Job
ss
cuss ype
Qpy
y
PSL-1207
BJ6
ROOF TRUSS
4
1'
, I e n us es, nc. us age
6.0.0_
1-0-0 6.0.0
3
6.00 rw
dl 2
1
6-0-0 - - - ---- -- - ' -
640.0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.69
Vert(LL) n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.26
Vert(TL) 0.13 1-2 >110
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANSl95
(Matrix)
Min Length / LL deft = 999
Weight 21 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 on center puriin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 5-8-8 on
center bracing.
REACTIONS pb/size) 3=150/0-2-0, 2=281/0-8-0, 4=57/0-3-8
Max Horz 2=242(load case 4)
Max Uplift3=197(load case 2). 2=203(load case 4)
FORCES (Ib)
TOP CHORD 1-2=23, 2-3=55
BOT CHORD 2-4=0
NOTES
1) This truss has been designed for the wind toads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3 Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3.
4; Provide mechanical connection (by others) of truss.to bearing plate capable of
Withstanding 197 lb uplift at joint 3 and 203 lb uplift at joint 2.
5) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
russ
I russ I ype
y
PSL-1207
CJ6
ROOF TRUSS
2
1
, 1 eK Industries- ncTue age
-1-5A 4-2-15 8-5.13 '
1-5.0 4-2-15 4-2-15
3x511
4
424 rW 6
3x5--
3
7
2x4=
2
9 6 10 5
- 1.5x4-11- - - - - - __ 3x5=
- - - 4-2-15 I 8S2 n13
4-2-15 - 42J 0.0-12
LOADING (psf)
SPACING 2-0.0
CSI
DEFL (in) (loc) Vdeff
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.99
Vert(LL) 0.04 5-6 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.82
Vert(TL) -0.06 5-6 ' >999
BCLL 0.0
Rep Stress Incr NO
WB 0.51
Horz(TL) 0.02 • 5 n/a
BCDL 10.0
Code SBC/ANSl95
(Matrix)
Min Length / LL deft = 240
Weight 40 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 2-1 D-15 on center pudin
BOT CHORD 2 X 4 SYP No.3 spacing, except end verticals.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 6-4-3 on
center bracing.
REACTIONS pb/size) 4=28410-2-0, 5=60310-3-8, 2=804/0-11-5
Max Horz 2=367(load case 4)
Max Uplift4=251(load case 4). 5=293(load case 3), 2=511(load case 2)
FORCES (lb)
TOP CHORD 1-2=25, 2-7=1397, 3-7=1271, 3-8=138, 4-8=74, 4-5=0
BOT CHORD 2-9=1269, 6-9=1269, 6-10=1269, 5-10=1269
WEBS 3-6=269, 3-5=1360
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSl95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) Except as shown below, special connection(s) required to support concentrated
load(s). Design of connection(s) is delegated to the building designer.
3) All plates are M20 plates unless otherwise indicated.
4) Gap between inside of top chord bearing and first diagonal or vertical web shall not
exceed 0.500in.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
6) Provide mechanical connection (by others) of truss to bearing plate capable of
Withstanding 251 lb uplift at joint 4, 293 lb uplift at joint 5 and 511 lb uplift at joint 2.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
Continued on page 2
1' _ ,
Job
I russ
toss I ype
Y
"8
PSL-1207
CJ8
ROOF TRUSS
2
1
-MiTe-< Inclustnes, Inc. ue age
-1-5-0 4-3-4m-la -.11-5.0 44 4 3.6-8 3.5.15
3X511 ~1
6-2-9
5.0-7 0-0.12
LOADING (psf)
SPACING
2-0-0
CSI
DEFL (in) (I-) Vdefl
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC
0.38
Vert(LL) -0.08 6-7 >999
M20 249/190
TCDL 7.0
Lumber Increase
1.25
BC
0.89
Vert(TL) -0.12 6-7 >999
BCLL 0.0
Rep Stress Incr
NO
WB
0.22
Horz(TL) 0.01 5 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 240
Weight: 56 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SYP No.3
TOP CHORD Sheathed or 3-11-2 on center purlin
BOT CHORD 2 X 4 SYP No.1 D
spacing, except end verticals.
WEBS 2 X 4 SYP No.3
BOT CHORD Rigid ceiling directly applied or 6-0-0 on
center bracing.
REACTIONS (lb/size) 5=0/0-2-0, 6=760/0-3-8, 2=464/0-11-5
Max Harz 2=250(load case 2)
Max Uplift5=27(load case 3), 6=-498(load case 3). 2=429(load case 2)
Max Grav5=59(load case 2), 6=760(load case 1), 2=464(load case 1)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=751, 3-4=760, 4-5=0, 5-6=0
BOT CHORD 2-7=704, 6-7=381
WEBS 3-7=16. 4-7=672, 4-6=504
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) Gap between inside of top chord bearing and first diagonal or vertical web shall not
exceed 0.500in.
4) Bearing at joint(s) 5 considers parallel to grain value using ANSMI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 5.
6) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 27 lb uplift at joint 5, 498 lb uplift at joint 6 and 429 lb uplift at joint 2.
Continued on page 2
Job Truss Truss Type y ,NU L-5
PSL-1207 CJ8 ROOF TRUSS 2 1
MiTecindustries, Inc. ue age
NOTES
7) This truss has been designed with ANSUTPI 1-1995 criteria.
8) Load case(s)1, 2, 3, 4 has been modified. Building designer must review loads to verify that they are correct for the
intended use of this truss.
Job
pe
y
PSL-1207
FG1
ROOF TRUSS
2
2
1 e c Inclustries, Inc. TUO age
4-0-0 8.0.0
4-0-0 4-0-0
1.5x4 II
1 5x5= 2 3x5= 3
4
365
3.00 (Tl
1.5x411 — - - - -- s
4.0-0 8-0-0
I i
440 4-"
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) Coo) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.16
Vert LL) 0.02 4 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.38
Vert-0.03 4 >999
BCLL 0.0
Rep Stress Incr NO
WB 0.16
Horz(TL) 0.00 3 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 480
Weight 64 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 on center pudin spacing,
BOT CHORD 2 X 4 SYP No.3 except end verticals.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 3.11-11 on
center bracing.
REACTIONS (lb/size) 5=452/0-8-0, 3=45210-3-8
Max Horz 5=205(load case 3)
Max Uplift5=217(load case 2), 3=243(load case 3)
FORCES (lb)
TOP CHORD 1-5=330, 1-2=1000, 2-3=1000
BOT CHORD 4-5=0, 3-4=1030
WEBS 1-4=1025, 2-1=232
NOTES
1) 2-ply truss to be connected together with 10d Common(.148"x3") Nails as follows:
Top chords connected with 1 row(s) at 0-9-0 on center. Bottom chords connected
with 1 row(s) at 0-9-0 on center. Webs connected with 1 row(s) at 0-9-0 on center.
2) This truss has been checked for unbalanced loading conditions.
3) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition.)
enclosed building, of dimensions 48 it by 32 It with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
4) Provide adequate drainage to prevent water ponding.
5) All plates are M20 plates unless otherwise indicated.
6) Bearing at joint(s) 5 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
Continued on page 2
n
Job ss russ ype y
PSL-1207 FG1 ROOF TRUSS 2 2
MiTeK industries, Inc. TUe age
NOTES
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 217 lb uplift at joint 5
and 243 lb uplift at joint 3.
8 This truss has been designed with ANSI/TPI 1-1995 criteria.
9 Load case(s) 1, 2, 3, 4, 5, 6 has been modified. Building designer must review loads to verify that they are correct
for the intended use of this truss.
o
toss
cuss ype
y
-
PSL-1207
H1016
ROOF TRUSS
1
1
1 I eK Indusmei�, Inc. I ue
age
-0 93 40.40 41-0.0
-0-0 8.2-13 0.
I
182 0
210-
I 3�
130+ 1 6.2-13 1 35-8.9.8.2-13 1
9
7xa= 5x5= 1.5x411 3x6= 1.5011 5x5= 7xa=
6.00 rrr 4 5 6 7 a 9 10
3x5q
3x6
3
11
7x6= 1 20 19 16 6x12= 1
3r6=
2 tOx12 M76_ 1.5x411 3x6=
1213j
d1 3x6=
24 23 22 16 15
14
1.5x411 6x6= 2x411 2x4117x6=
1.5x411
6-2-13 10-0-0 13.0.E 16 8-10 2058� 244-8 28 0 8 0 01 33.9-3 1_ 40-0.0
130
I + 1 I I
8-2-13 3-9.3 3.0.8 3.8.2 3.9.14 3-9-14 3-2 1-11-8 3.9-3 8-2-13
Plate se
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Udefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.88
Vert(LL) 0.92 19 >516
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.98
Vert(TL) -1.12 19 >425
M18 196/188
BCLL 0.0
Rep Stress Incr YES
WB 0.94
Horz(TL) 0.58 12 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL deft = 480
Weight 232 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 *Except* TOP CHORD Sheathed cr 2-4-3 on center pudin spacing.
4-10 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 1-8-0 on
BOT CHORD 2 X 4 SYP No.3 *Except* center bracing.
17-21 2 X 4 SYP No.1 D WEBS 1 Row at midpt
10-15
WEBS 2 X 4 SYP No.3 *Except*
4-21 2 X 4 SYP No.2
15-17 2 X 4 SYP No.2
10-17 2 X 4 SYP No.2
REACTIONS (lb/size) 2=1531/0-8-0, 12=1531/0-8-0
Max Horz 2=160(load case 2
Max Uplift2=989(load case 4), 12=989(load case 4)
FORCES (Ib)
TOP CHORD 1-2=12, 2-3=2704, 3-4=2406, 4-5=5289, 5-6=5273, 6-7=5273,
7-8=5159, 8-9=5159, 9-10=-4755, 10-11=2406, 11-12=2704,
12-13=12
BOT CHORD 2-24=2400, 23-24=2400, 22-23=0, 21-22=28, 5-21=154, 20-21=5304,
19-20=5417,18-19=5417,17-18=4759,16-17=17,9-17=-414, 15-16=0,
14-15=2400,12-14=2400
WEBS 3-24=100, 3-23=322, 4-23=1756, 21-23=2916, 4-21=4140, 5-20=20,
6-20=206, 7-20=176, 7-19=76, 7-18=315, 8-18=206, 9-18=493,
15-17=3737, 10-17=4624, 10-15=2857, 11-15=322, 11-14=100
NOTES
1) This truss has been checked for unbalanced loading conditions.
Continued on page 2
:POS:L-1207ZH101B
s cuss ype y ROOFTRUSS 1 1
1 e n us es,Inc. ue age
NOTES
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft above ground level, using 5.0
psf top chord dead load and 5.0 psf bottom chord dead load, 1 mi from hurricane oceanline, on an occupancy
category I, condition I enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per SBC/ANSI95
It end verticals or cantilevers exist they are exposed to wind. If porches exist they are not exposed to wind. The
lumber DOL increase is 1.60,.and the plate grip increase is 1.60 .
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 12.
6) This truss has been designed with ANSI/fPI 1-1995 criteria.
Job
russ
I russ I ype
y
-
PSL-1207
H102
ROOF TRUSS
1
1
1 I eK industries, Inc. Tue age
5-0.11 9.6-0 1W 14-11-5 204-0 �14-0
l I
11 4-7-e 0.6.0 4-7-5 5-4-11 1-0-
5x5=
5x5=
3 4
6.00 rM
3r5G y,5-,
2 5
US 11
3t5=
3z5=
1 6
7 j�
12 11 109 6
1.5c411 3z5= 3x5= 1.Sx411
3z5=
- -- - 5-0-11 941-0 1 14-71-5 20�-0
5-0-11 4-7-6 4.7-5 5-4-11
Plate Offsetsge , -
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.57
Vert(LL) 0.06 9 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.59
Vert(TL) -0.08 6-8 >999
BCLL ' 0.0
Rep Stress Incr YES
WB 0.26
Horz(TL) 0.04 6 n/a
BCDL 10.0
Code SBC/ANSI95
(Matrix)
Min Length / LL defl = 480
Weight 104 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 4-4-12 on center pudin
BOT CHORD 2 X 4 SYP No.3 spacing.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 7-8-7 on
WEDGE Left 2 X 4 SYP No.3 center bracing.
REACTIONS pb/size) 1=740/0-4-0. 6=80510-8-0
Max Horz 1=196(load case 2
Max Uplift 1 =439(load case 4), 6=559(load case 4)
Max Grav 1=742(load case 7), 6=805(load case 1)
FORCES (lb)
TOP CHORD 1-2=1269, 2-3=893, 3-4=752, 4-5=893, 5-6=1301, 6-7=23
BOT CHORD 1-12=1059, 11-12=1059, 10-11=1059, 9-10=752, 8-9=1100, 6-8=1100
WEBS 2-12=117, 2-10=362, 3-10=235, 4-9=246, 5-9=-410, 5-8=118
NOTES
1 This truss has been checked for unbalanced loading conditions.
2 This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3 Provide adequate drainage to prevent water ponding.
41 All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 439 lb uplift at joint 1 and 559 lb uplift at joint 6.
6) This truss has been designed with ANSI/fPI 1-1995 criteria.
o
russ
russ ype
wlyy
PSL-1207
H121 B
ROOF TRUSS
1
1
,0--I'J) Industries. Inc. Tue
age
12-0-0 17, 22-9-4 28-0-0 3319-3
40-0-0 41-0-0
fi-0 8.2-11 S9S 5-e-4 S3-0 52-12 59-3
8.2-13 1-0.0
SxS= 3x5= 3z5= US=
4 5 6 7
6.00 r
3u5!
7■Sa
3
a
1 14 6XI0-11
Sag=
6x12 3XS=
27 2
aI.DX4I
9 51
70
12
11
3.00 PT 2r4 II
4X6=
13-0-8
6-2-11 12-1-8 20-1-12 28-0.0 319.3
I 40-0-0
I I
6.2-11 510-13 8-04 7-10-4 59-3
6-2-13
Plate Lmets (7,,Y):. [2.'U-5-7.edgerge],7:0-0-12.D-2-21
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Vdefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.84
Vert(LL) 0.81 14 >592
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.99
Vert(TL) -1.05 14-15 >456
BCLL 0.0
Rep Stress Incr YES
WB 1.00
Horz(TL) 0.63 9 n/a
BCDL . 10.0
Code SBC/ANSI95
Min Length / LL defl = 480
Weight 229 lb
LUMBER BRACING
TOP CHORD. 2 X 4 SYP No.11) *Except* TOP CHORD Sheathed or 2-2-15 on center purlin
4-7 2 X 4 SYP No.2 spacing.
BOT CHORD 2 X 4 SYP No.2 *Except' BOT CHORD Rigid ceiling directly applied or 3-8-15 on
13-15 2 X 4 SYP No.1 D center bracing.
7-12 2 X 4 SYP No.3
WEBS 2 X 4 SYP No.3
OTHERS 2 X 4 SYP No.3
WEDGE Left 2 X 4 SYP No.3
REACTIONS (Ib/size) 2=1531/0-8-0, 9=1531/0-8-0
Max Horz2=194 load case 2
Max Uplift2=989(load case 4), 9=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=4892, 3-4=4552, 4-5�3244, 5-6=4513, 6-7=3910, '
7-8=-4464, 8-9=2704, 9-10=12
BOT CHORD 2-16=4439, 15-16=4481, 14-15=4591, 13-14=4472, 12-13=56,
7-13=1700, 11-12=0, 9-11=2401
WEBS 3-16=39, 3-15=238, 4-15=1738, 5-15=394, 5-14=119, 6-14=64,
6-13=-649, 11-13=2709, 8-13=1591, 8-11=1138
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load,l mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
Continued on page 2
PSL-1207 I H121 B I ROOF TRUSS
NOTES
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to grain formula. Building
designer shouldd verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 9.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
Truss
cuss I ype
y
PSL-1207
H141 B
ROOF TRUSS
1
1
Mire c industries. nc. ue c
age
- -0-0 &2-13 10.E-6 14-0-0 20.0-0 26.0.0 8.0-8 33.9-4
40.0-0 4/-0-0
-0-0 &2-13 457112
8.2-12 140-0
SxB= 1.5x411 US=
5 6 7 Sx6�
6.00 r1rE Sx6 8
4
3x8 1�-
3x6,,
3
9
17 16 15
3x8= 6x12 M16= 3x6= 3x5=
3x6=
1 2 3x5= .12=
1011
20 19 13
12
6x6= 2x411 2x411
4x6=
&�� 10.6-6 14.0-0 20-0-0 28-0-0 33.9-4
40-0-0
128-0-61
1 1 1
62 51 -13 41 33-8 8-0-0 8-0-0 2-0.6 5-&12
F
6-242
Plate Uffsets OVY L0:u-r3-u,u-z-1JJ. L1:u-r-u.u-2-tSJ, LIMU-1w4jedgel-
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Vdetl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.78
Vert(LL) 0.81 16 >590
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.98
Vert(TL) -1.02 16-17 >465
M18 196/188
BCLL 0.0
Rep Stress Incr YES
WB 0.94
Horz(TL) 0.72 10 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL defl = 480
Weight 233 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.1 D TOP CHORD Sheathed or 2-0-2 on center puriin spacing.
BOT CHORD 2 X 4 SYP No.3 *Except' BOT CHORD Rigid ceiling directly applied or 3-6-15 on
14-18 2 X 4 SYP No. ID center bracing.
10-13 2 X 4 SYP No.2 WEBS 1 Row at midpt
12-14
WEBS 2 X 4 SYP No.3 •Except•
18-20 2 X 6 SYP No.2
3-18 2 X 4 SYP No.2
REACTIONS (lb/size) 2=153110-8-0, 10=1531/0-8-0
Max Horz 2=218(load case 2)
Max Uplift2=989(load case 4), 10=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=-2704, 3-4=6947, 4-5=3973, 5-6=3952, 6-7=3952,
7-8=3973, 8-9=5589, 9-10=2704, 10-11=12
BOT CHORD 2-20=2401, 19-20=0, 18-19=43, 4-18=2566, 17-18=6218, 16-17=3602,
15-16=3602, 14-15=5010, 13-14=56, 8-14=2105, 12-13=0, 10-12=2401
WEBS 3-20=1837, 18-20=3087, 3-18=3825, 4-17=3034, 5-17=1310,
5-16=411, 6-16=313, 7-16=411, 7-15=1348, 8-15=2162, 12-14=2839,
9-14=2604, 9-12=1398
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 It
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 ml from hurricane oceanllne, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
Continued on page 2
'V
Job russ I cuss I ype y
PSL-1207 H141B ROOF TRUSS 1 1
1 re c industries, Inc. i us age
NOTES
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 10.
6) This truss has been designed with ANSIJTPI 1-1995 criteria.
Job
ss
russ ype
y
PSL-1207
H161 B
ROOF TRUSS
1
1
milecutoustries, Inc. ue
age
-1-" 2-13 0.8�
4
1 I I
1.2-593
6-2-13
5x5c 3=5= 5x5=
6 7 a
7aG6
6.00 frz- 2Y411 5t5"
5 9
4
3=5p
3x5.
3
10
17 16
s■a= s.a=
US=
316=
di 2 6s10_3 N
1112
JI
20 19 14
13
6x6= 2r411 29411
4a6=
6-2-13 11 18-1.6 211" I 26-0-0 1 33-9-3
i 41
—1 1 1
8.2-13 4511 5541 7.. 4.1-8
6-2-13
Plate se
ge
LOADING (psf):
SPACING 2-0-0
CSI
DEFL (in) (loc) VdeO
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.72
Vert(LL) 0.67 17 >716
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.98
Vert(TL) -0.99 16-17 >482
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(TL) 0.55 11 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL deft = 480
Weight: 229 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 •Except• TOP CHORD Sheathed or 2-2-10
on center purlin
6-8 2 X 4 SYP No.3 spacing.
BOT CHORD 2 X 4 SYP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 4-3-2 on
2-19 2 X 4 SYP No.3, 4-19 2 X 4 SYP No.3 center bracing.
9-14 2 X 4 SYP No.3
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1531/04-0, 11=1531/0-8-0
Max Horz 2=247(load case 2)
Max Uplift2=989(load case 4), 11=989(load case 4)
FORCES Ob)
TOP CHORD 1-2=12, 2-3=2704, 3-4=5135, 4-5=5630, 5-6=3728, 6-7=3401,
7-8=3401, 8-9=3728, 9-10=4456, 10-11=2704, 11-12=12
BOT CHORD 2-20=2401. 19-20=0, 18-19=43, 4-18=1181, 17-18=4090. 16-17=3493,
15-16=4090, 14-15=56,9-15=364,13-14=0,11-13=2401
WEBS 3-20=1379, 18-20=2822, 3-18=2304, 5-18=1772, 5-17=742,
6-17=1451, 7-17=137, 7-16=137, 8-16=1447, 9-16=723, 13-15=2705,
10-15=1587, 10-13=1130
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanllne, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) Provide adequate drainage to prevent water ponding.
Continued on page 2
PSL-1207 I H161 B I ROOF TRUSS
NOTES
4) All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 11.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
Truss
I russ I Ype
Y
PSL-1207
H181 B
ROOF TRUSS
1
1
1 e n us es, Inc. ue
age
14
i
41 411
1 62-13 4-5-11 i 3A-0 1 3.7-8 1 4-0-0 I 3571 1 2.6-5 I 59.3
I 6-2-13 1fi-0
6.00 j7T 5xe= 5x5=
7 e
Mica Us.
Sx5-- 6 9
2x411
3x64 10 3x61
4 s 11
3x5q
3x5,N
3 19 1e
12
20 5xe= 5x12=
3x6= yT 34, Or
1 .cal
1 2 Sx12 3.00 r1T
1314µ
b
23 22 16
15
6x6= 2411 2x411
4x6=
i 8-2-13 i 10.8.8 1448 1&1.8 21-10-8 2e-0.0 33.93
40-0.0
1 1 1
6-2-13 4-5-11 3-e-0 IM 1. 8.1-E 1.3
i i
fs2-13 -
Plate unets_
LOADING-(psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.78
Vert(LL) 0.66 18 >718
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.98
Vert(TL) -0.92 17-18 >519
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(TL) 0.56 13 n1a
BCDL 10.0
Code , SBC/ANSI95
Min Length / LL deft = 480
Weight 237 lb
LUMBER BRACING
TOP CHORD, 2 X 4 SYP No.2 *Except* TOP CHORD Sheathed or 2-2-7 on center pudin spacing.
7-8 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 4-2-14 on
BOT CHORD 2 X 4 SYP No.2 *Except center bracing.
2-22 2 X 4 SYP No.3, 5-22 2 X 4 SYP No.3.
10-16 2 X 4 SYP No.3
WEBS 2 X 4 SYP No.3 -
REACTIONS (lb/size) 2=1531/0-8-0, 13=1531/0-8-0
Max Horz 2=276(load case 2)
Max Upl•Ift2=989(load case 4), 13=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=2704, 3-4=-4618, 4-5=-4618, 5-6=3964, 6-7=3421,
7-8=3132, 8-9=3432, 9-10=5060, 10-11=-4798, 11-12=-4798,
12-13=2704, 13-14=12
BOT CHORD 2-23=2401, 22-23=0, 21-22=43. 5-21=361, 20-21=4233, 19-20=3654.
18-19=3092,17-18=3683, 16-17=56, 10-17=792,15-16=0,13-15=2401
WEBS 3-23=-1329, 21-23=2796, 3-21=1745, 5-20=652, 6-20=407, 6-19=-613,
7-19=1281, 7-18=63, 8-18=1341, 9-18=658, 9-17=1481, 15-17=2710,
12-17=1962, 12-15=1142
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceaniine, on an occupancy category I, condition
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip Increase is 1.60
Continued on page 2
ze
PSL-1207 I H181 B I ROOF TRUSS 11 11
NOTES
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 13.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
I
Job
russ
Russ ype
upy
Ply
-
PSL-1207
H62
ROOF TRUSS
1
1
, r e n us as, Inc. Tue age
tool 334 60o t6+o 14ao t7�tz zaao �t6q
I i I i i
1-0-0 3.3-4 2-&12 4<-0. 440 2-6.12 33� 1-0�-0
5x5= 3:5= 5.5=
4 5 6
6.00 I1T
1.5x4-- 1.5:4
3 �
axe= US
2 E rnµ1
9d
t2 11 10
its= 1.5:41: 3r5_
640 10-4-0 14-8-0 20-8.0
1
6-0-0 4.4-0 4-4-0 6-0-0
Plate Uffsets )J, [4:U-Z-tI.U-2-4J, L6:0-2-5.0-2-4j,
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.94
Vert(LL) 0.20 11 >999
M20 2491190
TCDL 7.0
Lumber Increase 1.25
BC 0.84
Vert(TL) -0.27 11 >922
BCLL 0.0
Rep Stress Incr NO
WB 0.39
Horz(TL) 0.09 8 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL deft = 480
Weight 103 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 *Except* TOP CHORD Sheathed or 1-9-6 on center purtin spacing.
4-6 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 4-10-3 on
BOT CHORD 2 X 4 SYP No.1 D center bracing.
WEBS 2 X 4 SYP No.3
.REACTIONS (lb/size) 2=2262/0-8-0, 8=2262/0-8-0
Max Horz 2=102(load case 3)
Max Uplift2=1207(load case 4), 8=1207(load case 4)
FORCES cab)
TOP CHORD 1-2=12, 2-3=3938, 3-4=3670, 4-5=3333, 5-6=3333, 6-7=3670, 7-8=3938, 8-9=12
BOT CHORD 2-12=3467, 11-12=3959, 10-11=3959, 8-10=3467
WEBS 3-12=213, 4-12=1146, 5-12=775, 5-11=244, 5-10=775, 6-10=1146, 7-10=213
NOTES
1) This truss has been checked for unbalanced loading conditions.
2)IThis truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanlme, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) Except as shown below, special connection(s) required to support concentrated
load(s). Design of connection(s) is delegated to the building designer.
4) Provide adequate drainage to prevent water ponding.
5 All plates are M20 plates unless otherwise indicated.
.6) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 1207 lb uplift at hint 2 and 1207 lb uplift at joint 8.
7) This truss has been designed with ANSIJTPI 1-1995 criteria.
Continued on page 2
O fuss russ I ype yLUR MANUK U,-
PSL-1207 H62 ROOF TRUSS 1 1
-Mie-k Industries- Inc. ue age
NOTES
8) Load case(s) 1, 2, 3, 4, 5, 6 has been modified. Building designer must review loads to verify that they are correct
for the intended use of this truss.
0
Job
Ss
fuss I ype
yL-tJ
PSL-1207
H81
ROOF TRUSS
1
3
, I e n us es, nc. ue age
32-0-0
-1.0-10 3••0-5 113361-311
13052
3410 2-0{ib151b18M.10SM39T-0
4x5= 6x6- '
6.00 rrr 6x6= sx10= 7x8= 2x411 4x6= 29411 7x8= Sx12=
3x5- 5 6 7 8 9 10 11 12 13 14 3x5�
1.5x4,\ 4
4x5= 3 16
?bZ4
10x12= 26 25 24 10x12- 4x5=
171
211 IxB= 2x411 4x6=
31 30 29 28 22 21 20 19
4x4= 4x5= US= 2x411 N411 4x6= 4x4=
4x8=
32.0-0
434 ' 8-0-0 10-0-4 13A8 16-8-10 20 &8 24-4-6 1— 30.&12 35-8.12 40-0-0
1 1 1 1 1
4 3 4 3.8-12 2.8-4 2S4 3 8 2 1 3 9 14 1 3 9 14 1 3 8 2 i 21s { 15 4 3 8 12 1 4-0 4
Plate Lmsets- - -
LOADING (psf)
SPACING -2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.52
Vert(I-Q 1.10 25 >433
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.92
Vert(TL) -1.16 25 >409
BCLL : 0.0
Rep Stress Incr NO
WB 0.95
Horz(TL) 0.50 17 n/a
BCDL 10.0
Code SBC/ANS195
Min Length / LL deft = 480
Weight 887 lb
LUMBER BRACING
TOP CHORD. 2 X 4 SYP No.3 *Except* TOP CHORD Sheathed or 6-0-0 on center pudin spacing.
5-7 2 X 6 SYP No.2, 7-14 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 on
BOT CHORD 2 X 6 SYP No.2 center bracing, Except .
WEBS; 2 X 4 SYP No.3 *Except
27-29 2 X 4 SYP No.2
6-27 2 X 4 SYP No.2
21-23 2 X 4 SYP No.2
13-23 2 X 4 SYP No.2
REACTIONS (lb/size) 2=3393/0-8-0, 17=3393/0-8-0
Max Horz 2=130(load case 2)
Max Uplift2=2296(load case 4), 17=2296(load case 4)
FORCES (lb)
TOP CHORD 1-2=13, 2-3=-6947, 3-4=6860, 4-5=6524, 5-6=5950, 6-7=19882,
7-8=19882, 8-9=-17323, 9-10=17323, 10-11=16965, 11-12=16965,
12-13=18956, 13-14=5956, 14-15=6524, 15-16=6860, 16-17=-6947,
17-18=13
BOT CHORD 2-31=6187, 30-31=6026. 29-30=7127, 28-29=0, 27-28=53, 8-27=916,
26-27=20004, 25-26=17777, 24-25=17777, 23-24=19073, 22-23=53,
12-23=627, 21-22=0, 20-21=6646, 19-20=6026, 17-19=6187
WEBS 3-31=74, 4-31=264, 4-30=229, 5-30=2241, 6-30=2260, 6-29=7138,
27-29=10164, 6-27=15431, 8-26=2873, 9-26=487, 10-26=511,
10-25=178, 10-24=916, 11-24=487, 12-24=2236, 21-23=9481,
13-23=14896, 13-21=6678, 13-20=2193, 14-20=2368, 15-20=229,
15-19=264, 16-19=74
Continued on page 2
M
PSL-1207 I H81 I ROOF TRUSS 11 13
NOTES
1) 3-ply truss to be connected together with 10d Common(.148"x3") Nails as follows: Top chords connected with 1
row(s) at 0-6-0 on center. Bottom chords connected with 2 row(s) at D-9-0 on center. Webs connected with 1
row(s) at 0-9-0 on center.
2) This truss has been checked for unbalanced loading conditions.
3) This truss has been designed for the wind loads generated by 110 mph winds at 15 It above ground level, using 5.0
psf top chord dead load and 5.0 psf bottom chord dead load, 1 mi from hurricane oceanline, on an occupancy
category I, condition I enclosed building, of dimensions 48 It by 32 It with exposure C ASCE 7-93 per SBC/ANSI95
If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The
lumber DOL increase is 1.60, and the plate grip increase is 1.60
4) Except as shown below, special connection(s) required to support concentrated load(s). Design of connection(s) is
delegated to the building designer.
5) Provide adequate drainage to prevent water ponding.
6) All plates are M20 plates unless otherwise indicated.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2296 lb uplift at Joint 2
and 2296 lb uplift at joint 17.
8) This truss has been designed with ANSI/TPI 1-1995 criteria.
9) Load case(s) 1, 2, 3, 4, 5, 6 has been modified. Building designer must review loads to verify that they are correct
for the intended use of this truss.
job
russ
fuss I ype
y
, '
PSL-1207
H81S
ROOF TRUSS
1
3
mil e c Industries, Inc. TUO age
-�-apz-ll-s oa-iz a+su to-11-z "M Ii
2-1i172-11-22 I i I I 42�-1
+...... -,.-w
3-8-12 434 i-0-0
7x6= 4x4= US= 2x411 US= U!1=400- 2011 6X6=
6'00 rrr
US-5 6 7 a 9 10 11 12 13
UX4= 4_ 7x5i
4x5; 3 _ 4x5=
27 20 26 30 25 31 24 tic12—
1s1
26 6x10= 4x4= .2x4 t1 4x5=
4x4, z2 21 zo 19 16 17
3xs II 4x4= 4x5- 4x5= 4x4= W II
3.00 rW
44-3 1 8.4-8 44.3 4.0.5 110.11-213 18.211I 239I I 320.1t'2 1 411,"10.1-2 1-2 2-1 12 -342-. 2-1 4
LOADING (psf) SPACING 240-0 CSI DEFL (in) Coe) Udefl PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.96 Vert(LL) 0.80 23-24 >599 M20 249/190
7CDL 7.0 Lumber Increase 1.25 BC 0.97 Vert(TL) -1.02 23-24 >469
BCLL 0.0 Rep Stress Incr NO WB 0.71 Horz(TL) 0.43 15 n/a
BCDL 10.0 Code SBC/ANSI95 (Matrix) Min Length / LL deft = 480 Weight: 829 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 *Except! TOP CHORD Sheathed or 3-9-9 on center purlin spacing.
10-13 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 on
5-10 2 X 6 SYP No.2 center bracing.
BOT CHORD 2 X 6 SYP No.2 *Except'
23-27 2 X 6 SYP SS
WEBS 2 X 4 SYP No.3 *Except'
5-27 2 X 6 SYP No.2
11-23 2 X 4 SYP No.2
REACTIONS (Ib/slze) 2=3938/0.8-0, 15=2383/0-8-0
Max Harz 2=135(load case 2)
Max Upl'Ift2=2131(load case 4), 15=13940oad case 4)
FORCES (Ib)
TOP CHORD 1-2=21, 2-3=12575, 3-4=13361, 4-5=16021, 5-6=15019, 6-7=16888,
7-8=17208, 8-9=17208, 9-10=17239, 10-11=17239, 11-12=5750,
12-13=5751, 13-14=4593, 14-15=-4724, 15-16=27
BOT CHORD 2-28=11160, 27-28=13614, 27-29=16917, 26-29=16867, 26-30=17242,
25-30=17242, 25-31=17242, 24-31=17242, 23-24=18498. 22-23=268,
9-23=1107, 21-22=1442, 20-21=7165, 19-20=7165, 18-19=4100,
17-18=4164, 15-17=4164
WEBS 3-28=1123, 4-28=1948, 4-27=1401, 5-27=6966, 6-27=2263,
6-26=1099, 7-26=-427, 7-25=90, 7-24=41, 8-24=325, 9-24=1437,
21-23=6645. 11-23=10910, 11-21=3545, 11-19=1968, 12-19=121,
13-19=2266, 13-18=225, 14-18=-82, 14-17=39
NOTES
1) 3-ply truss to be connected together with 10d Common(.148"X3l Nails as follows:
Top chords connected with 1 row(s) at D-9-0 on center. Bottom chords connected
with 3 row(s) at 0-5-0 on center. Webs connected with 1 row(s) at 0-9-0 on center.
Continued on bane 2
o ruse russ ypeIFIYIBAYLURMANUK'U',L;YPKhbS-BINL)L-t3
PSL-1207 H81S ROOF TRUSS 1 3
NOTES
2) This truss has been checked for unbalanced loading conditions.
3) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft above ground level, using 5.0
psf top chord dead load and 5.0 psf bottom chord dead load, 1 mi from hurricane oceanline, on an occupancy
category I, condition I enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per SBC/ANS195
If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The
lumber DOL increase is 1.60. and the plate grip increase is 1.60
4) Except as shown below, special connection(s) required to support concentrated load(s). Design of connection(s) is
delegated to the building designer.
5) Provide adequate drainage to prevent water ponding.
6) All plates are M20 plates unless otherwise indicated.
7) Bearing atjoi%s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to grain formula. Building
designer shouldd verify capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2131 lb uplift at joint 2
and 1394 lb uplift atjoint 15.
9) This truss has been designed with ANSI/TPI 1-1995 criteria.
10) Load case(s) 1, 2, 3, 4, 5, 6 has been modified. Building designer must review loads to verify that they are coned
for the intended use of this truss.
JOD
Truss
I cuss I ype
y
PSL-1207
H82
ROOF TRUSS
1
1
I e c Industries. Inc. I ue Oct 14 age
4-s-0 B-ao t2-8-o tStt-0 20-8-0
I I i f2141-0
I
'Is,33-0 1-8-0 3-3-04.9-0 1-0-0
4x8= SXS=
3 4
6.00 rrr
1 Ax4 1.5A
2 S
3x5=
3:5=
1
�( 7
10 9 8
3x5= 3x5=
3x5=
B-0-0 12.8-0 20-M
8.0.0 4-8-0 843-0 _
Plate Onsets
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) goc) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.50
Vert(LL) 0.07 10 >999
M20 249/190 -
TCDL 7.0
Lumber Increase 1.25
BC 0.71
Vert(TL) -0.16 1-10 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.07
Horc(TL) 0.03 6 n1a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL defl = 480
Weight: 98 lb
LUMBER BRACING
TOP CHORD 2 X,4 SYP No.3 TOP CHORD Sheathed or 5-0-0 on center purlin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 7-1-9 on
WEBS 2 X 4 SYP No.3 center bracing.
REACTIONS (lb/size) 1=754/0-8-0, 6=816/0-8-0
Max Horz 1=167(load case 2
Max Uplift 1=-450(load case 4;, 6=5620oad case 4)
FORCES (lb)
TOP CHORD 1-2=1190, 2-3=998, 3-4=900, 4-5=998, 5-6=-1190, 6-7=12
BOT CHORD 1-10=1053, 9-10=900, 8-9=900, 6-8=1053
WEBS 2-10=194, 3-10=231, 3-8=0, 4-8=231, 5-8=194
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
road, 1 mi from hurricane oceanllne, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip Increase is 1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 450 lb uplift at joint 1 and 562 lb uplift at joint 6.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
JOD
I fuss
Truss Type
y
,
PSL-1207
HS101A
ROOF TRUSS
1
1
1 I e industries, Inc. Tue age
-1-0-0 6-0-0 I 1041-0 I 15-0.12 I 19-&8 24-10.4 30-60 33.9.5 1 411
I I I I
t-0-0 860 4-0-0 5.0-12 4-7-12 51-12 5-1-12 395 8.2-11 1-0-0
5x8= 1.5x411 SxS= US= SX6=
6.00 PT 4 5 6 7 a
3x5 �
3 9
<N]JxSo
3x5� 19 1a 7x10— 17 3x5=
1 2 sx6= axe= 1011�
1.5x4
II
16 15 14 13 12
3.00 r1T 2x4 11 3x5= 3x8= 1.5x411
3x6=
19 -8—24-10� 30�0 IN 40.0.0
I I-""
6.0.0 4.1.8 4-11-4 4-7-12 5.1-12 5-1-12 3-9-5 B-2-11
Plate Onsetsge ,
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) • (loc) Udell
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.76
Vert(LL) 0.13 20 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.64
Vert(TL) -0.15 19-20 >999
BCLL 0.0
Rep Stress Ina YES
WB 0.76
Horz(TL) 0.06 10 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 480
Weight: 216 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 3-11-6 on center purin
BOT CHORD 2 X 4 SYP No.3 spacing.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 4-4-5 on
center bracing.
REACTIONS (Ib/size) 2=651/0-8-0, 16=1747/0-3-8, 10=664/0-8-0
Max Holz 2=1650oad case 2)
Max Uplfft2= 4991)oad case 4), 16=973(load case 4), 10=535(load case 2)
Max Grav2=659(load case 5). 16=1747(ioad case 1), 10=698(foad case 6)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=1458, 3-4=976, 4-5=208, 5-6=208, 6-7=1113, 7-8=456,
8-9=511, 9-10=820, 10-11=12
BOT CHORD 2-20=1322, 19-20=1342, 18-19=940, 17-18=1114, 16-17=1697,
6-17=1007, 15-16=0, 14-15=141. 13-14=141, 12-13=728, 10-12=728
WEBS 3-19=-412, 4-19=584, 5-18=266, 6-18=1515, 15-17=158, 7-17=1398,
7-15=27, 7-13=449, 8-13=12. 9-13=348, 9-12=100, 3-20=27,
4-18=-826
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. if
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase Is 1.60
3 Provide adequate drainage to prevent water ponding.
AIJ All plates are M20 plates unless otherwise indicated.
Continued on page 2
Job Nss Nss I ype y
PSL-1207 HS101A ROOF TRUSS 1 1
we (industries, Inc. Tue age
NOTES
5) Bearing at joints) 2 considers parallel to grain value using ANSIIrPI 1-1995 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 499 lb uplift at joint 2,
973 lb uplift at joint 16 and 535 lb uplift at joint 10.
7) This truss has been designed with ANSIrrPI 1-1995 criteria.
Job
Nss
NSS ype
y
PSL-1207
HS121
ROOF TRUSS
1
1
19fiTe-Kindustries, Inc. ue
aga
- 4-3.9 8.1-12 12.40 15.10.4 19-&8 2310-4 26-0-0 I 33.8.12
I 4_ —M 4 4-"
1 1 I I
1.0.0 4-3.9 3.10i 3-10{ '10-4 3.10-4 4-1-12 4-1-12 54-12
83.4 14)-0
5x5= 3x5= 2x411 3x5= 5x5=
S 8 7 5 9
6.00 rrr 3x5
4
1.5x411
1.50
10
3 t7 6X12= Is
.
3x5a =
5x8
z to
3:5=
111z�
d 3x5:
d'1 15 14
13
3.00 r1T 2x4 0 US=
3x5=
7 12-1-8 19-8.8 28" 33.8-12
40-"
:3
6-3-7 5-10.1 7-7-0 8-3-85.8-12
6-34
Plate se ge ,
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loo) Vdefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.80
Vert(LL) 0.12 18 >999
M20 249/190
TCDL 7.0.
Lumber Increase 1.25
BC 0.72
Vert(TL) -0.26 16-17 >902
BCLL 0.0
Rep Stress Incr YES
WB 0.62
Horz(TL) 0.04 11 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL deft = 480
Weight 222 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 4-2-1 on center puriin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 4-4-3 on
WEBS 2 X 4 SYP No.3 center bracing.
WEBS 1 Row at midpt
14-16
REACTIONS (lb/size) 2=635/0-8-0. 15=1779/0-3-8. 11=648/0-8-0
Max Horz 2=194(load case 2)
Max Uplift2=-490(load case 4), 15=990(load case 4), 11=539(load case 2)
Max Grav2=647(load case 5), 15=1779(load case 1), 11=697(load case 6)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=1497, 3-4=1270, 4-5=543, 5-6=-487, 6-7=1127, 7-8=1127,
8-9=260, 9-10=776, 10-11=782, 11-12=12
BOT CHORD 2-18=1346, 17-18=991, 16-17=88, 15-16=1702, 7-16=52, 14-15=0,
13-14=285,11-13=694
WEBS 3-18=178, 4-18=309, 4-17=-497, 5-17=34. 6-17=756, 6-16=1299,
14-16=56, 8-16=1344, 8-14=597, 9-14=351, 9-13=594, 10-13=308
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category i, condition I
enclosed building, of dimensions 48 It by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3 Provide adequate drainage to prevent water ponding.
4; All plates are M20 plates unless otherwise indicated.
Continued on page 2
PSL-1207 HS121 ROOF TRUSS 1 1
1 I eK inaustries, Inc. I us age
NOTES
5) Bearing at joints) 2 considers;parallel to grain value using ANSI/TPI 1-1995 angle to grain formula. Building
designer should verify capacitj of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 490 lb uplift at joint 2,
990 lb uplift at joint 15 and 539 lb uplift at joint 11.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
Truss
I russ I ype
y
PSL-1207
HS141
ROOF TRUSS
1
1
mile K Industries, Inc. Tue age
-}-610 411-9 1 9.5.12 I L 2eW-0 32-7-5 40.0-0 41W
117-a-0 119-f4a 1
I I
1-e-(1 4-11-9 4-0-4 4-0.4 3-0-0 2-e-s 6-3.6 6.75 7+t1 1-6-0
56= US= W 11 5X8=
5 6 7 S
6.00 jTr 314
4 Us
1.Sz4r 9
3 16 SX12- 15
-
W= St12= y
3;
j7 2 77 i4
1011
je
14 13 12
3.fp 2=411 5x6= 1.5x411
:7 I 14-41-6 s�I19- -- 2-0sI 32-75 40
577-3-7 I
7+11
a e se
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) poc) Udell
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.97
Vert(LL) ' 0.11 17 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.80
Vert(TL) -0.17 16-17 >999
BCLL 0.0
Rep Stress Ina YES
WB 0.57
Horz(TL) 0.04 •10 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL defi = 480
Weight 234 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 4-1-2 on center purlin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 4-3-10 on
WEBS 2 X 4 SYP No.3 center bracing.
OTHERS 2 X 4 SYP No.3 WEBS 1 Row at midpt B-15
REACTIONS (lb/size) 2=625/0.8-0, 14=1798/0.3-8, 10=639/0-8-0
Max Harz 2=223(load case 2
Max Uplift2=-491(load case 4), 14=990(load case 4), 10=552(load case 2)
Max Grav2=638(load case 5), 14=1798(load case 1), 10=702(load case 6)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=1392, 3ri=1097, 4-5=190, 5-6=163, 6-7=1016, 7-8=1012,
8-9=134, 9-10�673, 10-11=12
BOT CHORD 2-17=1256, 16-17=775. 15-16=304, 14-15=1738, 7-15=93, 13-14=0,
12-13=598, 10-12=598
WEBS 3-17=247, 4-17=400, 4-16=-607, 5-16=119, 6-16=769, 6-15=1122,
13-15=146, 8-15=1310, 8-13=320, 9-13=545, 9-12=135
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3 Provide adequate drainage to prevent water ponding.
4 All plates are M20 plates unless otherwise indicated.
Continued on page 2
>r
Job russ russ ype y
PSL-1207 HS141 ROOF TRUSS 1 1
i e C inaustnes, Inc. I ue age
NOTES
5) Bearing at joints) 2 considers parallel to grain value using ANSI/ TPI 1-1995 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 491 lb uplift at joint 2,
990 lb uplift at joint 14 and 5521 uplrft at olnt 10.
7) This truss has been designed with ANSlfTPI 1-1995 criteria.
o
fuss
I cuss I ype
y
PSL-1207
HS161
ROOF TRUSS
1
1
MiTeKindustnes,inc. ue
age
- 20-0 6-1-0 9-9.9 i6-0-0 20-0-0 24.0-0 28-0-0 33.9-5
40.0.0 41.0-0
1.0-0 5.1-0 441-9 8-2-7 4-0.0 4.0.0 4-0-0 5.9.5
6.2-11 -0-0
5xe= 1.5x4 a 5xe=
3x5c 6 7 e
6.00 jTl 5 51
9
3x5 i
4
1.Sx4x 17
7xsa
10
J is 5xa= 16
19 3x5n 3x5� 5x12�
sxs. Sxe,
11
7x6=
29 n
1
11,21
10-" 14
13
r
3.00 PT 2x4 11
Ix6=
7-3-1 16-0-0 20.0-0 24-0.0 28.0.0 33.9.5
40-0-0
7 3 1 8 815 4-0-0 4 0-0 4-0-0 1 .5
6-2-11
Plate Masgei,
-
LOADING (psnn
SPACING 2-0-0
CSI
DEFL (in) (loc) I/de8
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.79
Vert(LL) 0.77 17 >617
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 1.00
Vert(TL) -0.96 17 >496
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(TL) 0.67 11 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL detl = 480
Weight: 245 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 2-2.4 on center pudin spacing.
BOT CHORD 2 X 4 SYP No.2 *Except! BOT CHORD Rigid ceiling directly applied or 3-8-4 on
9-14 2 X 4 SYP No.3 center bracing.
-
WEBS 2 X 4 SYP No.3
OTHERS 2 X 4 SYP No.3
WEDGE Left 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1531/0-8-0. 11=1531/0-8-0
Max Horz 2=252(load case 2)
Max Uplift2=989(load case 4), 11=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=-4827, 3-4=4665, 4-5=-4073, 5-6=3702, 6-7=-4530,
7-8=-1530, 8-9=3702, 9-10=-4438, 10-11=2703, 11-12=12
BOT CHORD 2-20=4359, 19-20=4136, 18-19=3755, 17-18=3427, 16-17=3427,
15-16=4068,14-15=56,9-15=382,13-14=0,11-13=2399
WEBS 3-20=59, 4-20=261, 4-19=409, 6-18=511. 6-17=1546, 7-17=197,
8-17=1546, 8-16=464, 9-16=735, 13-15=2701, 10-15=1571,
10-13=1124. 5-19=355. 5-18=497
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanlme, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 it with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) Provide adequate drainage to prevent water ponding.
Continued on page 2
Job Truss I NSS I ype Py ,
PSL-1207 HS161 ROOF TRUSS 1 1
, 1 e n us es, nc. ue age
NOTES
4) All plates are M20 plates unless otherwise indicated.
5) Bearing at joints) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 11.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
job
ss
I cuss I ype
I
y
_
PSL-1207
HS181
ROOF TRUSS
1
1
i I eK industries, Inc. TUe
age
-0599
40h0 41.-
, 55
-0
2x4 11 �\
58.
s
3xs
6.00ITT 5 SxSc
3x5-�- 9
4
1.Sx4a 17
3x 19
3 16 5x8= 16
SxB, 5x19 345 3x5�g�x12a I
^,1 2 20 N
3x6=
1112R
a
14
13
3.00 rT 29411
4x8= _
7-3-1 18-0-0 _ 20-0-0 24-0-0-264L0 33.9-5
404-0
7-3-1 4-60 4.0-0 5-9.5
83-11
a e se
21:0-2-8,0-2-4 , 22:0-2-8,0-2-4 , 25:0-0-12,0-2-2
LOADING (psf)
SPACING 2-0.0
CSI
DEFL (in) (loc) Vdefl
PLATES GRIP,
TCLL 20.0
Plates Increase 1.25
TC 0.91
Vert(LL) 0.79 17 >606
M20 240/190
TCDL 7.0
Lumber Increase 1.25
BC 1.00
Vert(TL) -0.98 17 >487
BCLL 0.0
Rep Stress Incr YES
WB 0.99
Horz(TL) 0.67 11 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 480
Weight: 260 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 *Except* TOP CHORD Sheathed or 1-8-2 on center pudin spacing.
1-6 2 X 4 SYP No.2, 8-12 2 X 4 SYP No.2 BOT CHORD Rigid ceiling directly applied or 3-8-6 on
BOT CHORD 2 X 4 SYP No.2 *Except* center bracing.
9-14 2 X 4 SYP No.3
WEBS 2 X 4 SYP No.3
OTHERS 2 X 4 SYP No.3
WEDGE Left: 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1531/0-8-0, 11=1531/0-8-0
Max Horz 2=253(load case 2)
Max Uplift2=989(load case 4), 11=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=9, 2-3=-4827, 34=-4665, 4-5=-4073, 5-6=3747, 6-7=-4530,
7-8=-4530, 8-9=3774, 9-10=-4438, 10-11=2703, 11-12=12
BOT CHORD 2-20=4359, 19-20=4136, 18-19=3755, 17-18=3507, 16-17=3507,
15-16=4068,14-15=56,9-15=382,13-14=0,11-13=2399
WEBS 3-20=59, 4-20=261, 4-19=409, 6-18=370, 6-17=1500, 7-17=198,
8-17=1500, 8-16=390, 9-16=612, 13-15=2701, 10-15=1571,
10-13=1124, 5-19=355, 5-18=332
NOTES
1) This truss has been checked for unbalanced loading conditions.
Continued on page 2
Job russ Truss Type y
PSL-1207 HS181 ROOF TRUSS 1 1
r e n us es, nc. ue age
NOTES
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 it above ground level, using 5.0
psf top chord dead load and 5.0 psf bottom chord dead load, 1 mi from hurricane oceanline, on an occupancy
category I, condition I enclosed building, of dimensions 48 ft by 32 It with exposure C ASCE 7-93 per SBC/ANSI95
If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The
lumber DOL increase is 1.60, and the plate grip Increase is 1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are M20 plates unless otherwise indicated.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2 .
and 989 lb uplift at joint 11.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
o
russ
i cuss i ype
WLy
PSL-1207
J6
ROOF TRUSS
6
Irly
1
TOCON.Mmi e n us es, nc. ue age
-1.0-0 6-40
1-0.0 6�0
3
6.001rr
Z(4=
2
1
6-0-0
6.0-0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.72
Vert(LL) n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.26
Vert(TL) 0.13 1-2 >110
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANSI95
(Matrix)
Min Length / LL deft = 999
Weight 21 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 5-8-8 on
center bracing.
REACTIONS cab/size) 3=150/0-2-0, 2=281/0-8-0, 4=57/0-3-8
Max Horz 2=242(load case 4)
Max Uplift3=197(load case 2), 2=203(load case 4)
Max Grav3=156(load case 5), 2=281(load case 1). 4=57(load case 1)
FORCES (lb)
TOP CHORD 1-2=23, 2-3=55
BOT CHORD 2-4=0
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 it
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 it by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 3.
4) Provide mechanical connection (by others) of truss to bearing plate capable of '
withstanding 197 lb uplift at joint 3 and 203 lb uplift at joint 2.
5) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
Truss
I russ I ype
y
-
PSL-1207
J8
ROOF TRUSS
6
1
I I eK Industries, Inc. Tue age
-1.0-0 I 4-1-8
1-0-0 4-1-8 310.8
3
6.00 jTl
2x4=
2
8-0-0 I
8-0.0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.74
Vert(LL) n/a - n/a,-
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.48
Vert(TL) 0.30 1-2 >46
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANSI95
(Matrix)
Min Length / LL dell = 999
Weight 27 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.2 TOP CHORD Sheathed or 6-0-0 on center pudin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 7-8-8 on
center bracing.
REACTIONS pb/size) 3=205/0-2-0, 2=353/0-8-0, 4=77/0-3-8
Max Horz 2=3060oad case 4)
Max Uplik3=2690oad case 2), 2=2280oad case 4)
FORCES ((lb)
TOP CHORD 1-2=23, 2-3=75
BOT CHORD 2-4=0
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 It with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise Indicated.
3) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 269 lb uplift at joint 3 and 228 lb uplift at joint 2.
5) This truss has been designed with ANS11 TPI 1-1995 criteria.
Job
russ
Truss Type
y ,
PSL-1207
JG8
ROOF TRUSS
1
2
,U-t52)KK idustries, Inc. TUe age
4-1.8 I B-0-0
4-1-8 310.8
1.5x4 8
3
6.00 Rr
3x5G
2
3x5=
r 1
dyj
5
2x411 3x5-
41-8.� 8-0-0
4-1-8 31M
LOADING (psf)
SPACING 2-0 0
CSI
(in) (loc) Udefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.230.02
5 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.39-0.03
1-5 >999
FH
BCLL 0.0
Rep Stress Ina NO
WB 0.220.01
4 n/a
BCDL 10.0
Code SBC/ANSI95
/ LL deft = 240
Weight 91 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 4-2-1 on center pudin spacing.
BOT CHORD 2 X 6 SYP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 on
WEBS 2 X 4 SYP No.3 - center bracing.
REACTIONS (lb/size) 1=1569/0-8.0, 4=1569/0.6-0
Max Horz 1=249(load case 3)
Max Uplift1=769(load case 3), 4=895(load case 3)
FORCES (Ib)
TOP CHORD 1-2=1678, 2-3=0
BOT CHORD 1-5=1497, 4-5=1497
WEBS 3-4=101, 2-5=1361, 2-4=1702
NOTES
1) 2-ply truss to be connected togetherwith 10d Common(.148"x3°) Nails as follows:
Top chords connected with 1 row(s) at 0-9-0 on center. Bottom chords connected
with 2 row(s) at 0-9-0 on center. Webs connected with 1 row(s) at 0-9-0 on center.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 It with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) All plates are M20 plates unless otherwise indicated.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 769 lb uplift at joint 1 and 895 lb uplift at joint 4.
5) This truss has been designed with ANSI/fPI 1-1995 criteria.
6) Load case(s) 1, 2, 3, 4 has been modified. Building designer must review loads to
verify that they are correct for the intended use of this truss.
Job
russ
russ ype
y
YLUK tj '
PSL-1207
SBJ2
ROOF TRUSS
2
1
r e n us es, nc. ue age
1-0-0 2.40
1.0-0 2.0-0
3
6.00 rrr
3x5
3.00 rrr
2-0.0
�2-0-0
Plate Onsets lei
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) pod) Vdefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.15
-Vert(LL) n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.03
Vert(TL) • 0.01 1 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00 - 3 n/a
BCDL -. 10.0
Code SBC/ANSI95
(Matrix):•
Min Length/ LL defl = 999
Weight 8 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed.
BOT CHORD 2 X 4 SYP. No.3 BOT CHORD Rigid ceiling directly applied or 1-11-9 on
center bracing.
REACTIONS pb/size) 3=36/0-2-0, 2=144/0-8-0, 4=19/0-3-8
Max Horz 2=110(load case 4)
Max Uplift3=53(load case 2), 2=156(load case 4)
Max Grav3=52(load case 5), 2=144(load case 1), 4=19(load case 1)
FORCES (lb)
TOP CHORD 1-2=16, 2-3=35
BOT CHORD 2-4=4
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBCIANS195 If,end verticals or cantilevers exist, they are exposed to wind. If
poroes exist, they are not exposed to wind. The lumber DOL Increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3 Bearing at jornt(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
4) Provide others) of truss to bearing atjoint(s) 3.
mechanical connection (by plate
5 Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 53 lb uplift at joint 3 and 156, Ib uplift at joint 2.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
:P-SL-1'2]07
FSBJ4:
russ ype
ROOF TRUSS
2
y
1
i e n us es, nc. We -age
1.0.0 4.0-0
4.0.0
LOADING (psf)
SPACING.
2-0-0
CSI
DEFL can) (loc) Well
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC 0.31
Vert(LL) n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase
1.25
BC 0.11
Vert(TL) 0.04 1-2 >392
BCLL 0.0
Rep Stress Ina
YES
WB 0.00
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANS195
(Matrix)
Min Length / LL defl = 999
Weight: 15 lb
LUMBER
BRACING
TOP CHORD 2
X 4 SYP No.3
TOP CHORD Sheathed.
BOT CHORD 2
X 4 SYP No.3
BOT CHORD Rigid ceiling directly applied or 3-9-14 on
center bracing.
REACTIONS (lb/size) 3=92/0-2-0, 2=210/0-8-0. 4=3710-3-8
Max Horz 2=172(load case 4)
Max Uplrf0=127(load case 2), 2=176(load case 4)
Max Grav3=1020oad case 5), 2=210(load case 1), 4=37(load case 1)
FORCES (lb)
TOP CHORD 1-2=17, 2-3=35
BOT CHORD 2-4=7
NOTES
1) This truss has been designed for the wind roads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanlme, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise Indicated.
3) Bearing at joints) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate atjoint(s) 3.
5) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 127 lb uplift at joint 3 and 176 lb uplift at joint 2.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
JOD
Truss
I cuss I ype
y
PSL-1207
SBJ6
ROOF TRUSS
2
1
I I eK Industries, Inc. I ue age
-1-0•o I B-0-0
i
1 0 0 6-0-0
3
6.00It1
e3x5z-:
2
1 3.00 r"
6-0-0
6.0.0
Rate Offsets (A'y):-T'a ge
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (foe) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.72
Vert(LL) - n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.26
Vert(TL) 0.14 1-2 >100
BCLL 0.0
Rep Stress Incr YES
WB 0.00:
Horz(TL) -0.00 3 n/a
BCDL 10.0
Code SBC/ANSI95
(Matra)
Min Length / LL defl = 999
Weight 21 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 5-10-10 on
center bracing.
REACTIONS cab/size) 3=150/0-2-0, 2=281/0-8-0, 4=57/0-3-8
Max Horz 2=237(load case 4)
Max Uplrft3=202(load case 2), 2=198(load case 4)
Max Grav3=1560oad case 5), 2=281(load case 1), 4=570oad case 1)
FORCES cab)
TOP CHORD 1-2=17, 2-3=56
BOT CHORD 2-4=11
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 It
above ground level, using 5.0 psf top chord dead road and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanlrne, on an occupancy category I, condition
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If and verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60. and
the plate grip increase Is 1.60
2 All plates are M20 plates unless otherwise Indicated.
3 Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 3.
5 Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 202 lb uplift at joint 3 and 198 lb uplift at joint 2.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
russ
I russ I ype
y
_
PSL-1207
SCJ8
ROOF TRUSS
1
1
I i eK inaustnes, Inc. Tue age
1-5-0 6.100.14 11-2-4
1S0 6-10.14 4-3-7
1.5=411
5 6
425 r1T US5
4
2x4= 9
3-
7
US=
3xs= 5
2 35
2.15 rrr - --
6-10-14 _. E" ` 11-2-4
I
6.10.14 4-3.7
-Plate LMse
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) Qoc) Well
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.60
Vert(LL) 0.13 2-8 >967
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.74
Vert(TL) -0.16 2-8 >816
BCLL 0.0
Rep Stress Incr NO
WB 0.39
Horz(TL) 0.02 7 n/a
BCDL 10.0
Code SBC/ANSI95
(Matra)
Min Length / LL defl = 240
Weight 52 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 4-11-11 on center pudin
BOT CHORD 2 X 4 SYP No.2 spacing, except end verticals.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 6-8-3 on
center bracing.
REACTIONS (lb/size) 6=176/0-2-0, 7=895/0-3-8, 2=445/0-11-5
Max Horz 2=258(load case 4)
Max Uplrft6=176(load case 1), 7=521(load case 4), 2=385(load case 2)
Max Grav 6=81 (load case 3), 7=895(load case 1), 2=445(load case 1)
FORCES (lb)
TOP CHORD 1-2=17, 2-3=1137, 3-9=1226, 4-9=1226, 4-5=63, 5-6=59, 5-7=178
BOT CHORD 2-B=1125, 7-8=1228
WEBS 4-8=608, 4-7=1103, 3-8=98
NOTES
1) This truss has been designed for the wind loads generated by 110 mph winds at 15 It
above ground revel, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanllne, on an occupancy category 1, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase Is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6.
5) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 176 lb uplift at joint 6, 521 lb uplift at joint 7 and 385 lb uplift at joint 2.
6) This truss has been designed with ANSI/TPI 1-1995 criteria.
Continued on page 2
Job
PSL-1207 SCJ8 ROOF TRUSS 1 1
MrTe c Industries, Ino. TUe age
NOTES
7) Load easels) 1, 2, 3, 4 has been modified. Building designer must review loads to verify that they are correct for the
intended use of this truss.
Job 4
Nss
Nss I ype
wry
illy
ESAYLOK MANOR
PSL-1207
SJ8
ROOF TRUSS
9
1
-SPACE CC AST I 111.16b,r e n us es, nc. ue age
-1-0-0 . 5-1-1 8-0-0
1-0-0 5-1-1 2.10-15
4
15X4_
6.00 rM
3
5
1.Sz4a
3z5:
2
].00 j7T
8-0-0
a e se ge
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.39
Vert(LL) 0.00 2 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.57
Vert(TL) -0.20 2-5 >449
BCLL 0.0
Rep Stress Ina YES
WB 0.11
Horz(TL) -0.01 5 n/a
BCDL 10.0
Code SBC/ANS195
(Matrix)
Min Length / LL dell = 480
Weight 32 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 on center pudin spacing.
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 8-2-9 on
WEBS 2 X 4 SYP No.3 center bracing.
REACTIONS (lb/size) 4=51/0.2-0, 2=348/0-8-0, 5=235/0-3-8
Max Horz 2=301(load case 4)
Max Uplift4=84(load case 2), 2=221(load case 3), 5=174(load case 4)
Max Grav 5=243(load case 5)
FORCES (lb)
TOP CHORD 1-2=17, 2-3=418, 3-4=51
BOT CHORD 2-5=342
WEBS 3-5=328
NOTES
.1) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per
SBC/ANS195 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
2) All plates are M20 plates unless otherwise indicated.
3) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1-1995 angle to
grain formula. Building designer should verify capacity of bearing surface.
4) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4.
5) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 84 lb uplift at joint 4, 221 lb uplift at joint 2 and 174 lb uplift at joint 5.
6) This truss has been designed with ANSIIrPI 1-1995 criteria.
Job
russ
cuss ype
y
-
PSL-1207
T1
ROOF TRUSS
2
1
, 1 e n us es, nc. ue
age
15-4-9 20-0-0
10-8-8 24-7-8 28-0-0 33.93
40-0-0 4H-0-0
I I I I I
1.0-0 8-2-13 451, 4-7. 4-7-8 348 5.93
I
6-2-13
6.00 FrE
US=
3n64 7
3x5y US,,
6 e USI,
5 9
2 d 11 20
10
4
3a5 -
US,,
3 17
n
sxe_
3=6= dT Sa10a 9
q, 2 St10o ,u100� ri�l
33 1
1213
20 19 15
14
6X6= 2K41i 2A 11
4a6=
6.2-13 I 10 8.8 I 20.0-0 2e-0.0 33.9.3
40.04
I 1
8.2-13 45-11 9J-B 8-0-0 5.9J
1
6.2-13
Plate se -
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) (loc) Vdefl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.80
_
Vert(LL) 0.71 17 >676
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.98
Vert(TL) -1.21 17-18 >395
BCLL 0.0
Rep Stress lncr YES -
WB 0.99
Harz(TL) 0.56 12 n/a
BCDL - 10.0
Code SBC/ANSI95
Min Length / LL deb = 480
Weight 226 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 *Except* TOP CHORD Sheathed or 2-2-10 on center purlin
1-6 2 X 4 SYP No.2, 8-13 2 X 4 SYP No.2 spacing.
BOT CHORD 2 X 4 SYP No.3 *Except' BOT CHORD Rigid ceiling directly applied or 4-3-15 on
17-18 2 X 4 SYP No.1 D center bracing.
16-17 2 X 4 SYP No.2
12-15 2 X 4 SYP No.2
WEBS 2 X 4 SYP No.3
REACTIONS (lb/size) 2=1531/0-8-0, 12=1531/0-8-0
Max Harz 2=305(load case 3)
Max Uplift2=989(load case 4), 12=989(load case 4)
FORCES (lb)
TOP CHORD 1-2=12. 2-3=2704, 3-4=-4952, 4-5=5160, 5-6=3142, 6-7=3142,
7-8=3142, 8-9=3142, 9-10=4982, 10-11=-4767, 11-12=2704,
12-13=12
BOT CHORD 2-20=2401, 19-20=0, 18-19=43, 4-18=715, 17-18=3502, 16-17=3531,
15-16=56, 10-16=719, 14-15=0, 12-14=2401
WEBS 3-20=1330, 18-20=2796, 3-18=2141. 5-18=1635. 5-17=701,
7-17=2561, 9-17=738, 9-16=1516, 14-16=2707, 11-16=1935,
11-14=1134
NOTES
1) This truss has been checked for unbalanced loading conditions.
Continued on page 2
Job russ I russ I ype y
PSL-1207 T1 ROOF TRUSS 2 1
1 I e Inaustries. Inc. TUe age
NOTES
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 It above ground level, using 5.0
psf top chord dead load and 5.0 psf bottom chord dead load, 1 mi from hurricane oceanline, on an occupancy
category I, condition I enclosed building, of dimensions 48 ft by 32 ft with exposure C ASCE 7-93 per SBC/ANSI95
If end verticals or cantilevers exist, they are exposed to wind. If porches exist, they are not exposed to wind. The
lumber DOL increase is 1.60, and the plate grip increase is 1.60
3) All plates are M20 plates unless otherwise indicated.
4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 989 lb uplift at joint 2
and 989 lb uplift at joint 12.
5) This truss has been designed with ANSIfrPI 1-1995 criteria.
4 1. f
Job
PSL-1207
Nss
T16
cuss y
ROOF TRUSS
wly
4
my
1
-
, i e n us es, Inc. I ue age
-1-0-0 434 8.0.0 11-NT L= 1L--
1.0.0 444 3.6.12 3.8.12 434 100
LOADING (psi) SPACING 2-0-0
c TCLL.. 20.0 Plates Increase 1.25
: TCDL 7.0 Lumber Increase 1.25
BCLL 0.0 Rep Stress Ina YES
BCDL • .10.0 Code SBC/ANSI95
LUMBER
TOP CHORD 2 X 4 SYP No.3
BOT CHORD 2 X 4 SYP No.3
WEBS.- - . 2 X 4 SYP N0.3
4x4=
a
W=
CSI DEFL (in) (loo) Well PLATES GRIP
TC 0.40 Vert(LL) . 0.04 8 >999 M20 249/190
BC 0.71 Vert(TL) -0.14 2-8 >999
WB 0.11 Horz(TL) 0.02 6 n/a
Min Length / LL dell = 480 Weight: 72 lb
BRACING
TOP CHORD Sheathed or 6-11-7 on center purlin
spacing.
BOT CHORD Rigid ceiling directly applied or 8-6-5 on
center bracing.
REACTIONS (lb/size) 2=643/0-4-0. 6=643/0-4-0
Max Horz 2=131(load case 2)
Max Uplift2�159(load case 4), 6=-459(load case 4)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=847, 3-4=632, 4-5=632, 5-6=847, 6-7=12
BOT CHORD 2-8=749, 6-8=749
WEBS. 3-8=209, 4-8=355, 5-8=209
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by.110 mph winds at 15 It
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 It with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they ere exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) All plates are M20 plates unless otherwise Indicated.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 459 lb uplift at Joint 2 and 452 lb uplift at joint 6.
5) This truss has been designed with ANSI/TPI 1-1995 criteria.
o
Nss
Nss Iype
Qty
y
PSL-1207
T16GE
ROOF TRUSS
1
1
r e K inaustries. Inc. 1 ue age
434 8-0-0 11-5-12
1-0-0 434 341-12 3-8.12 444
4x4=
axe=
LOADING (psf)
SPACING
240-b .
CSI
DEFL (in) (loc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase
1.25
TC
0.40
Vert(LL) 0.04 8 >999
M20 249/190
TCDL 7.0
Lumber Increase
1.25
BC
0.71
Vert(TL) -0.14 2-8 >999
BCLL 0.0
Rep Stress Inca
YES
WB
0.11
Horz(TL) 0.02 6 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 480
Weight: 88 lb
LUMBER
TOP CHORD 2 X 4 SYP No.3
BRACING
TOP CHORD Sheathed or 6-11-7 on center purlin
BOT CHORD 2 X 4 SYP No.3
spacing.
WEBS 2 X 4 SYP No.3
BOT CHORD Rigid ceiling directly applied or 8-6-5 on
OTHERS 2 X 4 SYP No.3
center bracing.
REACTIONS (lb/size) 2=643/0-4-0, 6=643/0-4-0
Max Horz 2=131(load case 2)
Max Uplift2= 459(load case 4), 6=-459(load case 4)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=847, 3-4=632, 4-5=632, 5-6=847, 6-7=12
BOT CHORD 2-8=749, 6-8=749
WEBS 3-8=209, 4-8=355, 5-8=209
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 it
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 ft by 32 it with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) All plates are M20 plates unless otherwise indicated.
4) Gable studs spaced at 2-0-0 on center.
5 For studs exposed to wind, see MTek "Standard Gable End Detail"
6) Provide mechanical connection (by others) of truss to bearing plate capable of
Withstanding 459 lb uplift at joint 2 and 459 lb uplift at joint 6.
7) This truss has been designed with ANSI/TPI 1-1995 criteria.
Job
Truss
Truss TYPO
y _
PSL-1207
T2S
ROOF TRUSS
2
1
i eIndustries,Inc. ue age
4-11-9 i .10.0.0 15-0.7 29-4-e
I
4.11-9 5-0-8 5.0.7 5-3-9 1-0-0
4x4=
3
6.00ITT
1.5x4 ij
2 4
axe 0
3x5=
1 3=5=
!� 5
(�
6 b
3x5= 3x5= 3x5=
6.8-3 i 13314 204-0
6-8.3 6.7-11 7.0.2
Plate Uffsets,e ge
LOADING (psf)
SPACING 240-0
CSI•
DEFL (in) (loo) Udefl -
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.62
Vert(LL) 0.06 7 >999
M20 2491190
TCDL 7.0
Lumber Increase :1.25-
BC- 0.67
Vert(TL) -0.13 7-9 >999.
BCLL 0.0
Rep Stress Ina • YES
WB 0.16
Horz(TL) .. 0.03 5 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL deft = 480
Weight: 93 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP 'CHORD Sheathed or 4-9-13 on center purlin
BOT CHORD 2 X 4 SYP No.3 spacing.
WEBS 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 7-9-3 on
WEDGE* Left 2 X 4 SYP No.3 center bracing.
REACTIONS (lb/size) 1=742/0-4-0, 5=803/0-8-0
Max Harz 1=201(load case 2
Max Uplift1=442(load case 415=5550oad case 4)
FORCES Qb)
TOP CHORD 1-2=1124, 2-3=978, 3-4=1004, 4-5=1158, 5-6=12
BOT CHORD 1-9=981, 8-9=692, 7-8=692, 5-7=1026
WEBS 2-9=188, 3-9=340, 3-7=383, 4-7=228
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 it
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 ml from hurricane oceanline, on an occupancy category I, condition I
enclosed building, of dimensions 48 It by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. if
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) All plates are M20 plates unless otherwise indicated.
4) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 442 lb uplift at joint 1 and 555 lb uplift at joint 5.
5)-This truss has been designed with ANSI/fPI 1-1995 criteria.
Job
Truss
Iruss lype
y
PSL-1207
T3
KINGPOST
2
1
i I ex industries, Inc. Tue
age
-1-0-9 3-6-0 7-0-0
B-0-0
1-0.0 3S0 330
1-0-0
4x4=
3
6.00 r1T
2x4_
2x4=
z Fl
4
5
1 6
1.5x4 0
axe B 3xe n.
64-0
7-0.0
0-B•0_. - - 2.10-0 2-10-0
I ,
0.8.0
Plate Onsetsge . ge ,
LOADING (psf)
SPACING 240-0
CSI
DEFL (in) (loc) Wall
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0A1
Vert(LL) 0.00 6 >999
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.50
Vert(TL) 0.01 4-5 >999
SCLL 0.0
Rep Stress Incr. YES
WB 0.02
Horz(TL) 0.00 4 n/a
BCDL 10.0
Code SBC/ANSI95
Min Length / LL dell = 480
Weight 32 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 on center pudlri spacing. •
BOT CHORD 2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 on
WEBS 2 X 4 SYP No.3 center bracing.
WEDGE Left 2 X 6 SYP No.2,
Right 2 X 6 SYP No.2
REACTIONS (lb/size) 2=310/0-6-0, 4=310/0-6-0
Max Harz 2=65(load case 3)
Max Upiift2=261(load case 4). 4=261Qoad case 4)
Max Grav4=364(load case 7)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=264, 3-4=264, 4-5=12
BOT CHORD 2-6=233, 4-6=233
WEBS 3.6=67
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) This truss has been designed for the wind loads generated by 110 mph winds at 15 ft
above ground level, using 5.0 psf top chord dead load and 5.0 psf bottom chord dead
load, 1 mi from hurricane oceanline, on an occupancy category 1, condition I
enclosed building, of dimensions 48 It by 32 ft with exposure C ASCE 7-93 per
SBC/ANSI95 If end verticals or cantilevers exist, they are exposed to wind. If
porches exist, they are not exposed to wind. The lumber DOL increase is 1.60, and
the plate grip increase is 1.60
3) Except as shown below, special connections) required to support concentrated
load(s). Design of connection(s) is delegated to the building designer.
4 All plates are M20 plates unless otherwise indicated.
5 Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 261 lb uplift at joint 2 and 261 lb uplift at joint 4.
Continued on page 2
o russ cuss ype y COR MANOR'D', CYPRESS t31NU L-a
PSL-1207 T3 KINGPOST 2. 1
I e n us es, nc, ue age
NOTES
6) This truss has been designed with ANSI/fPI 1-1995 criteria.
f
oTruss
a
Truss Type
y
PSL-1207
T3GE
KINGPOST
1
1
1 I ek Industries, Inc. I ue—IOWT475M.52 1997 Page
-1-0-0 3-6-0 7-0-0 8.0-0
1-0-0 380 3-&0 1.0.0
4x4=
3
6.00 ITT
at4 = ac4=
4
yµ� 2 S K�
1
1.5x4 II
7.0.0
r 7-0-0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL (in) poc) I/defl
PLATES GRIP
TCLL 20.0
Plates Increase 1.25
TC 0.31
Vert(LL) n/a - n/a
M20 249/190
TCDL 7.0
Lumber Increase 1.25
BC 0.07
Vert(TL) 0.01 4-5 >999
BCLL 0.0
Rep Stress Incr YES
WB 0.04
' Horz(TL) 0.00 n/a
BCDL 10.0
Code SBC/ANS195
Min Length / LL deft = 999
Weight 28 lb
LUMBER BRACING
TOP CHORD 2 X 4 SYP No.3 TOP CHORD Sheathed or 6-0-0 on center pudin spacing.
BOT CHORD -2 X 4 SYP No.3 BOT CHORD Rigid ceiling directly applied or 211-9 on
OTHERS 2 X 4 SYP No.3 center bracing.
REACTIONS (lb/size) 2=202/7-0-0, 4=202/7-0-0, 6=217/7-0-0
Max Horz 2=99(load case 3), 4=99(load case 2)
Max Upl'Ift2=202(load case 4), 4=202(load case 4), 6=1170oad case 4)
Max Grav4=256(load case 7), 6=217(load case 1)
FORCES (lb)
TOP CHORD 1-2=12, 2-3=33, 3-4=33, 4-5=12
BOT CHORD 2-0=0, 4-6=0
WEBS 3-0=150
NOTES
1) This truss has been checked for unbalanced loading conditions.
2) Except as shown below, special connection(s) required to support concentrated
load(s). Design of connection(s) is delegated to the building designer.
3) All plates are M20 plates unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) Gable studs spaced at 2-0-0 on center.
6) For studs exposed to wind, see MTek "Standard Gable End Detail"
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 202 lb uplift at joint 2, 202 lb uplift at joint 4 and 117 lb uplift at joint 6.
8) This truss has been designed with ANSI/TPI 1-1995 criteria.
PSL
TOP BTM IWEB MET I STN
61
82
63
FL
JKS
PSL
TOP BTM WEB MET I STN
61
62 , —
B3 — -
FL
JKS
PSL
milegimuT ®
-----
i m-m--
om mmm
mommm
PSL `
TOP BTM WEB MET STN
B1
B2
B3
FL
JKS
Ifulmmaumml
mmmmm
mmmmm
PSL
• ' w . ®®
- -----
-----
- m-mm-
SL
• ' ' vk,T*dm
_mm--
m—mmmmmm
—
PSL
mk-"mlmmuwm
mmmmm
mmmmm
_mmmm
• ' - m®mI
m _----
- --_--
i mm-mt