HomeMy WebLinkAboutENGINEERING INSTALLATION METHODSFL #: FL 17022.1 R6
Date: 12 / 22 / 16
CBUCK Engineerinq Page Report No.: 6 16-16
76-5V-S6W-ER
Sppciaity Structural E=nc21r71PIPr1nc2 CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
5-V Crimp (26 Gauge steel) Roof Panel attached to Wood Deck
Drawings
.00 24'
12"
3/8"
OPTIONAL STRIATIONS
Panel Profile
Nomnal 12" o.c. I Nominal 12" o.c.
Fastener
#9 x 1-12' Min. or #10 x 1-1/2" Min. per Table "A'
Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel Overlap . Refer to Table "A" for Spacing Along Panel Length
Deck:
-15/32" or greater Plywood, or
- Wood plank
Typical Assembly Profile View
(Typical Fastening Pattern Accross Width - Interior)
FL #: FL 17022.1 R6
Date: 12 / 22 / 16
NCBUCK Enq�neer�nq Page rt No.: 7 of 76-5V-S6W-ER
SpealdlN Structural EnginLowing CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
5-V Crimp (26 Gauge Steel) Roof Panel attached to Wood Deck
njulu a iauiauui i
-15/32" or greater Plywood, or Thickness 3" Ma)amum
- Wood plank
Typical Roof Assembly
Isometric View
(Optional) Rigid Insulation Board per Page 4 of this report
TABLE "A"
ALLOWA DS
METHOD 1:
ETHOD 2:
METHOD 3:
METHOD 4:
Design Pressure (ASD)*:
- 86 PSF
- 93.5 PSF
-101 PSF
- 228 PSF
Row Spacing:
6" o.c.
8" o.c.
6" o.c.
Fastener Spacing (across panel width):
12 o.c.
12" o.c.
12" o.c.
12" o.c.
Fastener Size:
#9
#10
#10
#10
*Allowable design pressures) for allowable stress design (ASD) with a margin of safety of 2 to 1.
i
d.'
FLORIDA, OaPAATMSW OF
Busine8s & Professional Regulation
jug,
BCIS Home I Login I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff I BCIS Site Map Links I Search
FI Ma
Product Approval
(q r 0 _Y USER: Public User
LP� u,YF
Product Aooroval Menu > Product or Application Search > Application List > Application Detail
OFFICE OF THE FL #SECRErARY
FL5259-R26
Application Type Revision
Code Version 201
Application Status Approved
Comments
Archived 0
Product Manufacturer QLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative James E. Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Ind. Park
Hazleton, PA 18202
(800)894-4563
akins@polyglass.com
Quality Assurance Representative Ariel Lender
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALender@polyglass.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 04/24/2018
Validated By John W. Knezevich, PE
Cdi Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259 R26 COI 2017 01 COI Nieminen.odf
Standard
Year
ASTM D1970
2009
ASTM D226
2006
ASTM D6164
2005
ASTM D6222
2008
ASTM G154
2006
ASTM G155
2005
FM 4474 2004
v'
FRSA/TRI April 2012 2012
TAS 103 1995
UL 1897 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
03/13/2017
Date Validated
03/22/2017
Date Pending FBC Approval
03/22/2017
Date Approved
06/13/2017
Date Revised
09/14/2017
Summary of Products
FL #
Model, Number or Name
Description
Polygiass Roo
Roofin underlayments
Underla me is
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular
FL5259 R26 AE 2017 03 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
R26.Ddf
underlayment system (over concrete deck) for
use under foam -on tile systems (where the
Created by Independent Third Party: Yes
underlayment forms part of the load -path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
Back F11e.1
Contact UsUs :: 2601 Blair Stone Road. Tallahassee R 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® W ® eghsck
Credit Card
Safe
S
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
TRINI-rY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1122
150 Lyon Drive FL5259-1126
Fernley, NV 98408 Date of Issuance: 02/24/2009
(570) 384-1230 Revision 22: 03/13/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the S`h Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION:
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 03/13/2017. This does not serve as an electronically
signed document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1.' Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY I ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 51h Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2004
1504.3.1
Wind Uplift
UL 1897
2004
1504.6
Accelerated Weathering
ASTM G154
2006
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.3, 1507.3.3, 1507.5.3; 1507.7.3,
Physical Properties
ASTM D226
2006
1507.8.3,1507.9.3
1507.2.4, 1507.2.9.2, 1507.5.3, 1507.7.3
Physical Properties
ASTM D1970
2009
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.3.3
Installation Practice
FRSA/TRI April 2012
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20117A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-111
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-1122
Certificate of Authorization #9503 , FBC NON-HVHZ EVALUATION FI5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 2 of 14
TRINITY I ERD
Enti Examination Reference Date
ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift 131738.02.07-112 04/29/2013
ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013
ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD (TST 6049) Physical Properties P44360.10.14 10/07/2014
ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 04/24/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically.Fastened'Underlayments
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4:2 Self -Adhering Underlayments: -
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick MTS PLUS is -a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FLS2S9-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 3 of 14
Q\TRINITYIERD
. 4.2.4 Po[ stir -TU P us is a nomina 80-mi tthic ru erize as alt wafer roo in membrane, ass i er rein ores ,wit a
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
4.2.8 Polystick Dual Pro"" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.9 Polystick Tile ProT* is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of an sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380,
Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the `Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 4 of 14
\I I RININ I ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet In 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
PolystickTU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
TABLE lAc ALLOWABLE TILE ADHESIVE]'UNDERLAYMENT COMI9INATIONS1
Adhesive
Florida Product
Underlayments
Approval
Convenience Products' Touch 'n
FL14506
Polystick TU Plus, Polystick TU Max
Seal StormBond Roof Tile Adhesive
Dow TileBondlm
FL717
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap
FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap
FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile
FL17855
Polystick TU Plus or Polystick TU Max
Adhesive
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-RZ6
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 5 of 14
i
TRINITY I ERD
5.6 Allowable Substrates:
-> q.61 Direct;Bon E!to,Deck
Po ystick i e4Pro, Po y ex'SAP oraSAt? FR Ntu a Hi` a SA APP,xCaPP Gap�S eet
(NO*untreate . ;uvood„ ASTM°D41 ,rune_ ,new'untreate w;,Existin `'•woo' rASTiVI D41 rime 1ex�stin
p y nroo ;Z New or existing, unprime % = 86 ,ASTM ime OSB,MSout ern Ye ow Pine; ASTM iD_41 prime
Sout, ern �Ye owPme, GtiSTM D41� nrrie'_ structura �egncrete�Hu er�En irieere_�a11,Vo4 s GZIP�S'stem� Pane s
e$i ne_aari �insta a oirneet__wnd oa"_s�_orp_r"oieCt'c
Note- Po ` assdoes notre_ u�re rrinrn ho new orexistin' r ,woo'.,, or,�OSe�shegt in .-'New or�eXistin - .virgo_ , or.
OS seat rng s ou d e c eane _o ;a �rt and a 'risfpnor to app i¢atCo ystic, mem` canes:
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA, Inc Revision 22: 03/13/2017
Page 6 of 14
TRINITY I ERD
5.6.4.30 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set the (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 5.3, Note 1 of ASTM D1970-09, should be established as to slip resistance.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
1.6.31 ''Elastobase, Elastobase P orMule-Hide Nail Base
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile ADDlications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied.
6.3.3 Tile ADDlications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FLS2S9-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 11 of 14
r� �l
C)o
TRINITY 1 ERD
6.4 Polystick'MTS, MTS PLUS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide -SA-APP Cap Sheet (FR):
6.4.1 Shall be installed in compliance with the codified requirements for ASTM D197U untierlayment in 1-BL Sections isui
for the type of prepared roof covering to be installed.
Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM
D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and
seller, as set forth in Section 5.3, Note 1 of ASTM D1970-09, should be established as to slip resistance.
6.4.2
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must b
firmly rolled with a minimum 28 lb. han
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge c
the top sheet to the end of the glue patter
(the sheet will overlap the fabric).
View of Ovelap Seam of Dual Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (mi n. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for Polystick /R-Xe or Polystick MU X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set the applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat the at slopes in excess of 5:12.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certijkate of Authorization #9503 FSC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 12 of 14
TRINITY 1 ERD
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
`6 5 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR: ,
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6 6 Polo ex G or Polyflex G FR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered the roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied applied "Cap Sheet" in the "Two Ply System" from
FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVAWATION FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 13 of 14
�TRINI-ffIERD
6.7 Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRl April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent the sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.7.4 For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat the at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
Exterior Research and Design, U.C.
Certificate of Authorization #9503
- END OF EVALUATION REPORT -
FBC NON-HVHZ EVALUATION
Polyglass USA, Inc.
Evaluation Report P12060.02.09-R22
FL5259-R26
Revision 22: 03/13/2017
Page 14 of 14