HomeMy WebLinkAboutCERTIFICATE FOR DESIGN LOAD COMPLIANCEI Planning & Development Services Department • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: BAKER Project Address: 3913 SHORESIDE DR, FT PIERCE, FL 34949 Permit #: 1712-0182 Occupancy Type: Construction Type: DOCK INSTRUCTIONS FOR USE: • This certification.must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2014 Code Fifth Edition with 20 Supplements using ASCE 7-10 2. Structure Designed as (check one): Enclosed Partially Enclosed X Open 3. Risk Category: _I x II III IV Exposure Category: B W C D 4. Design Wind Velocity 165 mph ASD x LRFD End Zone Width: 1 ft 5. Mean Roof Height 6+/- Deck Height ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +60.6i-64.1 Zone 5: +70.1/a4.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: _ PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified - WWI I I I I I, ?z Daniel P RetherFord 72451PA L N'%` Print Name Cert # & Co. Cert Auth. 6 � � Signattfi,oar] Date�� ea �r ® 1402 Hartman Road, Ft Pierce, FL 34947 ;! Fop ® Company Name & Address Revise 07/ gTV IDN. h (