Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL PANEL WALLS SIDING�w 3 ����� IA�b�C'i8'1'�{7i�a a.�* � � a. � � a �v,. � `. , �➢� �w r� r�'j�� . � rofZZ apdktr 1L�- °. Product Approval USER: Public User Product Approval Menu > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance � ORATg NEW- CONCEAEEO -0 Of RESPONSt%pECORDNE pACiON 0 Flon gineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By OPOSEO WpV1K p ALL o WAS NS aPl lay C J'f Oft j"Ai tale ' CY TO A C'iOaS Cery'���i1d®r1C�` �ApEF TO pEQU%vieD�CSSSAApppLlCpgLB COp�S' RefeGnd Year (of Standard) CO Equivalence of Product Standards Certified By FE"L`113_119�2-R4 Revision 2014 Approved 01 James Hardie Building Products, Inc. 26300 La Alameda Ste. 250 Mission Viejo, CA 92691 (909) 349-2927 pingsheng.zhu@jameshardie.com Pingsheng Zhu pingsheng.zhu@jameshardie.com EC DEC 2SS201? PERMII--rl!.:,�a St. Lucie COLa12;', FL Pin shen Zhu j r(�TIO11 9 g 5T. LU NTTY LiLD+NC DIVISION 10901 Elm Ave. REVIEWED FOR COMPLIA CE Fontana, CA 92337y;�JED BY (909)349-2927 pingsheng.zhu@jameshMT 2 PLANS AWPERNM MUST BE XEPT ON JOB Pingsheng Zhu OR NO INSPECTION WILL BE MADE. 10901 Elm Ave. Fontana, CA 92337 (909) 349-2927 pingsheng.zhu@jameshardie.com Panel Walls Siding Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer M Evaluation Report - Hardcopy Received Ronald I. Ogawa PE-24121 Intertek Testing Services NA, Inc. 01/01/2018 John Southard, P.E. l Validation Checklist - Hardcopy Received FL13192 R4 COI RIO - Certificate of Independence, PDF Standard Year ASTM C1186 2007 ASTM E330 "le c® x, 2002 Florida Licensed Professional Engineer or Architect FL13192 R4 Eauiv ASTM C1186 Equivalency Sianed.Ddf Flori daProd.u.- ..A*:,P. itieplan La, iin. ....... ..... . ........... .. . ....................................... ............................. ... ... ................. . . . . ... . . ... . ... ... NEW: .......... . ... .. . . ...... :Opt Mm ............... iie"D ro, d drft. 1011MUSTBA7 -::F.:4!`t6 b1ho OWW Fid fib, .............................................. . FAMER:REQUIREI TMI TS * _..................... �; GndiJaifing is the:preterred method of:msiaflabon far HartliePlarik dap srdm products Face nar Mg sharid an{y t used usher required by coda#ar hr h wmd areas aia must not be used in.conjufrgtion tivr<h Blir2d na�l�ng (Please see JH Tech: buf�ebn 17 for exempUarr Veri d�(►t9 a nepaEr PuI�G�dced corners riiey be done dniisttretic Purp>ises Or t wbacfrs shaliCbe done wrtff finish nails onlyt and are not,a substitute fot.filmd orface naifin� .: FACEf[AlCihtG:: ;Nails:=Iflfood Fr .... g 2'lt" HD x 2" long) � 5d (b i 13' shank x f) 287" HO � 2" iong� sNhk kO 37 f" HD z 1269bbg) Srdigg nail (g tl9' sErank x t3 z2i" Hfi: 2 long) : .........::...... Screws::S#eel am1119. is WdlerResisSve !V 1-td mm. Bamef Umrnate s6eeT to be remoued immediately aiier nstatidon;of each course #or CotarPlus .- products. "Whep face r>arl[rtg:to QSB,.p(atrks trust=t a na.greaeter. fhnn 9: 4 `wide artd fasteners must be t 0:0 ar less:. . .. "°:AlsoNO.: rarai3asteningRequirements:arritwhen:carisrderin aitemativafasieafng:ogti nsrelertoJamesttattlresTect(ticaif3ulieiCriUSi8:77<..Fasteninq:Tt foeHarstieFlank ................... pgmetor, ... Da.not install James ...... �..!q productS. Mc Ile • For:larger prof cis u pgappmmere ........sari..... These value amclobt of ..p..s. .pniari M .0g1h T of James Hardie" S'di 'Rod: IVat , . ......... 'A R.O: . Vol We:oajl t: INSTALLA jbiNt-tRFATMw R70 -.3-2 Hardie recomtnE for ... ............ .... . ........... ;aii ..... . . .. .. . AifforM.: FOrl bo:mooasoh ado ibt:9.09811sNad :Ory POW Wpdu+r ;77.7 sawbbt-.Wdbes not carry p A aftrk Areo . . ........ 1p:3-441 Must 4810floMdaccordance uNth local huildwng cif es tcon a, W. standing water,A6 6' *06, nk.only. . .. . .... I .. .... ... .... .. ..... . . . .. . . ..... .. ... : ..... ... Aff'O.P.Aa. e0ardle-Prodm; JUAWL.. 00!04c�: tenor.:..:., IV * oeft-s/4'. ... ..... .. RdMep Roforto caulking'so, . ... . ....... . ..... Barnet vW 'fid(d 6M M fppco ................ )UST Lath fiaced Hammer :Dr}e$ trot apply fortnstafldtlon to st�uf V! .. ............. ... q.u... .... u k* n tOM M, . snug: flush: DDONOTtin ' , ONOT, M: A . . .hails.. ....... . .. ... ............. PAINTIMR: . .base... .. .... . Otl ........... i . .. ... ... ..... Products .I amos.l.a.. .... e..i.ff....b.:.d;.i.u.. 1.oW.J.ff.. st ue ......... PO..M. ..—..d within l.-. I ;.K da ys .1...0.01...p..r.I med h MOacrylic .PACQAtS:pr0@9 t paint mo �fo(:app6paintmanufacturers.: .. ........ :tp*gpa nBack msrecommended if n : a. sprayed;: ..... ....... ... ......... ...... ........... ..................... .0 ETREA Caul,..... . ............. . .... .......... 0 kftsaare q;R Colo h ... ... ..... .... . .. req ufred. ... ....... .. . .... ... .. ManufalclUr ....►r8'.:­fACQ' dC-A*"O"r.'6'.s**Ot"V."a'tho-treatbd*: . ..... recomtnetdppace ... ......... mat to eyontdireotio0q :of.-AC.Q-*. 'CA, .......... — . preservative-0.P. ed:M­0*­9dai­nd.. 4­jlUP...P.`U.m.. K....P.d..ub t0:Fnsterrers used'td attach" kirdieOft Tauslopreservative NIr e - ......... q--..::.......�..0 dipped' , N....4..........:.. ............. ....... ......... -&::9,ainle ted:66id 1P- SRC .. . ... .... galvanized:tw6l .... . .. l� .. .. . ..... . :2W. ... . ... . ..... ...... . . ..... .. I'g, air VaWl g.A: ...... . ... i .balft be J96 ta, I' . ...... m. pos: OWN- 0.: . ... 1, . : op-1. - $.' -fise S:'t' 'h `kafa pio UM. - Nod, amps:HW does : Va he Osage Of (Wdl WON' i6rpalft: "daouc up off: amm. e:CA. fo�Plw. d ... ... P .-th . . ... t� ........ 11.1 ..... , . : H ........ .......... . Ff6bjO#j&with*#jj&* 0 ... . ... Mi" -:bf1h"d i ili , * i .. .. ... . I' , "at* . ...... U -wudh up v Apm.e,pf.v%.dr(.m V pp aslox, � p�qi: psfNITOMAQ -: ... 0 A 19 Jd Uh Ah U .... .pan W.-PARSUS0.1 u M touch. AM041 9 d--f ...... T diunder Jfi arran i: ........... . Handle U:- ... jn�hw ColorPlus .... . ...... ......... ........... -- ... ......... . - ............ -- .................. -- ................. B* 71 ----- - WALL HEIGHT .i ii ALL LENGTH at 16" O.C. i 314" Mnimum DETJLA hisS�a .22-: as wriapiyma W= pqe ram �i- - Bw'l�e�ti'- 9' '. ~rrrl�vl lJ 1 V � � 1 Distance Nails at 16" O.C. (typ_) Sheathing fastener, as described in Note 1 Siding fastener, as described in Note 2 HardiePlank, Cemplank, Prevail Lap Siding Water -resistive barrier per Florida Building Code Section 1404.2 a \\, "is"think / 5 pcy APA rated �` ---- plywood sheathing fastened .in accordance with Florida Building Code Section 2322.3 2" X 4" S-P-F Wood Studs The wall and soffit frames are to be designed by the Architect or Engineer of Record in comoliancewith the Florida Building Code. SM DETAIL A FRQDU msp— EMOIN A�' `$t`dtel?lank®, _GempianM & Prevail® Plank Lap Siding materials are nonasbestos fiber -cement S18" thick 15 ply APA products tested in accordance with rated plymod ASTM C1186 Grade it, Type A and sheathing in meeting the requirements Of the a=rdancewith Florida Building Code. Florida Building Code Sadon 2322 sA ENS_L0 �ter_n � Width Length Thickness \ barrier per Florida :gg -1/2' 12' 5116" Building Code Sechan 14042 DES_GN PFtiI=SSUERE_R_Mk \ 2"X V_, p_F installation Design Pressure Wood Studs Wood Studs -92 pe Lap Siding Impact Resistant - Planks installed over 6181, thick 15 ply 1-114" tali X 511s" APA rated plywood sheathing thick starter strip iA ?o EI QNtC�cl�itFl?�a_rvl�, rxce�►J �.+,�.,���u� � ram._ -_ t_= _ -ce All installation shall be done in conformance with this Natice of Acceptance, the manufacturePs instailafion recommendations, and the applicable sections of the Florida Building Coda ■ Wood shads where 1�ardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an Engineer orArd►itect iser the Florida Buildng Code and the requirements of this N.OA [date 1] 518" thick 15 ply APA rated plywood sheathing shall be attached to the studs in accordance with Florida Suiiding Code Section?322.3. ■ Planks shall be applied course of the wall fica 1-1/4" wide lied horizontally commencing from the bo - ... is 5 $-1/4" vertiglly IIA1ote 2� a SVMing West er snot r e a:471L-4_ jVI- , �.��_,.��� �.� w ,arm . _ corrosran resistant sidirig,na�,:The sicrng is fastened 5 8-114" O.C. vertically and 16" O.C. ho> entallnerYs fasteners are driven into wood studs through 518" thick 15 ply APA rated plywood sheathing, are placed in the overlapping area appro0amately 314. from the bottom edge of the overlapping plank. • Vertical joints shall be placed over studs. ■ The planks shall be Installed over 518" thick / 5 ply APA rated plywood sheathing supported by a minimum of Z X4" S-P-F wood studs spaced a maximum of 16" O.C. ■ Fasteners shall have a minimum edge distance of 319. Creator. E. Gonzales 9 HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, lnm 10901 Elm Avenue Fontana, CA 92337 112" - 1'-0" D{Mk•7 NO PNL-PLK-SOFF 1 late: 4/24/2413 I SHEE' 5 OF 12 Fastener Spacing per Florida Blinding Code Section 2322.3 .f l _�, I Fastener Spacing per Florida \ Building Code Section 2322-3 ffi oong�tyiggwie�msl�ide Hm1�C� Aoa�pRmcc Iw f ' � ll, � i By PradretC�ait -- - T ,'r_F2AAMIIVCx ■ NOMINAL 2" X 4" S-P-F WOOD STUDS 160 O.C. FASTENED WITH S-112" 16cJ COMMON NAILS (2 PER TOP AND BOTTOM CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING ■ NOMINAL 518" THICK / 5 PLY APA RATED PLYWOOD SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA BUILDING CODE SECTION 2322.3 ■ PLANKS.OVERLAP 1-1/4" ■ THE EXPOSURE IS 58-1/4" ■ THE PLANKS ARE FACE NAILED WITH 2-1/2" LONG, 0.223" HEAD DIAMETER, 0.09r SHANK DIAMETER, CORRO$I01`F RESISTANT SIDING NAILS, -PLACED 3/4" UP FROM THE BOTTOM EDGE OF THE PLANKAT EACH STUD LOCATIW 6 in. Cladding Framing I / Sheathing PRODL'Cr REWSED • I ��,, .. aI� : No. 121 w-M w15 ; ? . = SPATE OF pro 'FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND iS�l`IrYI-OAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS WOOD STUD CONSTRUCTION James Hardie Building Products, Ins 10901 Elm Avenue Fontana, CA 92337 7ZE FSCM NO DW3 NO REV A PNL-PLK SOFF 1 Creator. E. Gonzales SCALE 1" = t'-0" Dale: 4/2412013 IsHEer 6 OF 12 WALL HEIGHT r at 16, O,C. B as B F-= 3/4" Minimum Edge Distance • DETAIi� ilro Florins !, 7 SEE TAIL A -`� Sr8" thick /5 ply APA r rated plywood shealhing fastened to metal studs as described in Note 1 WaterLresr Ve _ bamer per Florida i BulldkV Code c Section 14042 PIRODUCT D_P!jC 91PTIQt! HardiePlankQi, CemplankilD, and Prevail® Plank Lap Siding materials are nonasbestos fiber -cement products tested in accordance with ASTM 01186 Grade II, Type A and meeting the requirements of the Florida Building Code. PUNK D1MEIdSIONS. Width Length Thickness 5 9.1/2" 12' 51161• 20ga, 3-5r8' X 1-518" DESIGN PRESSU$E RA i tNG Memel C-stud F ` * Installation Design Pressure HarcliePlank, Metal Studs .92 psf prank, Prevail s �f ANAL . �\ ` Lap Siding Impact Resistant — Naffs at 16" O.C. (typ.) S_ECTIQ 1-1/4' tall X 5116' Planks installed over 518" thick / 5 I ''���� � APA rated plywood sheathing thick starter strip Sheathing fastener, as described in Note 1 Siding fastener, as described in Note 2 l 1 HardiePlank, j� Cemplank; /! Prevail Lap Siding Water -resistive barrier per Florida Building Code Section 1404.2 5/8" thick 15 ply APA rated plywood sheathing fastened to metal studs as described in Note 1 20ga, 3-5/8" X 1-518" Metal C-stud The wall and soffit frames are to be designed by the Architect or Engineer of Record in compliance with the Florida Building Code, HARDIEPL,AWK. PLAA PPLEVAIL L__%t%NG_INSiA4A1ION DBE gU_ ■ Ail installation shall be done in conformance vAth this Notice of Acceptance, the manufacturer's installation recommendations, and the applicable sections of the Florida Building Code. • Metal studs where HardiePlank, CemplanK Prevail Lap Siding will be installed shall be designed by an Engineer or Architect per the Florida Building Code and the requirements of this N.OA ■ ENote 11 5/8" thick /5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel edges and all intermediate supports using a No,&l8, 0.315" head drameterx 1-1W long bugle head screw Planks shall be applied horizontally commencing from the bottom course of the wail with 14W wide laps at the top of the plank such that the exposure area of each plank is s 8-114" vertically. • [Note 21 The siding fastener shall be a minimum No. 8-18, 0.315" head diameter X 2-1/4" long* bugle head screw over metal studs (*or screw shall have at least 3 full threads penetrating metal framing); The siding is fastened se. 8-1/4" O.C. vertically and 1G' O.C. horizontally; fasteners are driven into metal studs through 6/8" thick 15 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 314" from the bottom edge of the overlapping plank. ■ Vertical joints shall be placed over studs. ■ The planks shall be installed I over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum 20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" Q.C. ■ Fasteners shall have a minimum edge distance of 3/8". HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING INSTALLATION DETAILS METAL SPUD CONSTRUCTION James Hardie Building Products, Inc, 10901 Elm Avenue Fontana, CA 92337 A I I PNL-PL K-SOFF ,Creator. E. Gonzales ISC.ALE 1/2"=T-0" I Date:4/2412013 7OF12 0.75in Be C0=V *V WiiQafbe PARi6e Bmimi"� t3-c 14-10' 58.25in. ' �M.JIs� ■ NOMINAL 20 GAUGE 3-5/S" X 1.6/8" STEEL STUDS le O.C. FASTENED WITH 518" LONG RIBBED BUGLE HEAD SCREWS. (2 PER TOP AND BOTTOM CONNECTION) ■ THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE WITH THE FLORIDA BUILDING CODE SHEATHING ■ NOMINALSZ'THICK15 PLYAPA RATED PLYWOOD SHEATHING TO METAL STUDS AT S" OC AT -PANEL EDGES AND ALL INTERMEDIATE SUPPORTS USING A NO.8-18, 0.315" HEAD DIAMETER X 1-1W LONG BUGLE HEAD SCREW CLADUTAiG PLANKS OVERLAP 1-1W ■ THE EXPOSURE IS 58-114' THE PLANKS ARE FASTENED WITH NO. 8.18, 0.315" HEAD DIAMETER X 2-1/4' LONG CORROSION - RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3 FULL THREADS PENETRATING THE METAL FRAMING), PLACED 3/4' UP FROM THE BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION in. Claddng • ' I Framing • 6.00t OC Sheathing I- OGAIy REVLSW Go*- •�0 21 y STATE 4F FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS) HARDIEPLANK, CEMPLANIe, PREVAIL LAP SIDING INSTALLATION DETAILS METAL STUD CONSTRUCTION James Hardie Building ProdUGtS,.Ino, 10901 Elm Avenue Fontana, CA 92337 Fax 909-427-0634 A PNL-PLK-SOFF Creator_ E. Gonzales ISCALE 1" =1'-0" Date: 4114/2013 SHEET 8 OF 12 1 DEC 2 8 2017 PERMITTING St. Lucie County, FL