Loading...
HomeMy WebLinkAboutPROJECT INFORMATION+ wrightsofte Project Summary Jo Entire House By: QUICK CALCS, INC. For. THE•GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL �` �Q � Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh. Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 .Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 Infiltration sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average . Fireplaces 0, Structure 3203 Btuh Ducts . 2318 Btuh Central vent (0 cfm) 0 Btuh. Heatingg Coolingg Area Tat (none) (ft2) 1446 Equipment latent load 5521 Btuh VOlume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR . 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A" 030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref , 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 @ 470F Latent cooling 10440 Btuh .Btuh Temperature rise 27 OF Total cooling 34800' Btuh Actual air flow -1160 cfm Actualair flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh . Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio . 0.83. Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t wrl hso tft` 2017-Apr-1109:29:38 .-�-. 9 Right-Suite�aJ Universal 2017 17.0.14 RSU08101 .Page 1 '�� ...uick Calcs%Documents%THE GRAND CARLTON-1446.6up Calc = MJ8 Front Door faces: N - wrigntsoft° Right-J® Worksheet Job: • Entire House Date: QUICK CALCS, INC. BY: 317 ST LUCIELN., FT. PIERCE, FL 34946•Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire. House BEDROOM 2 FVosed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft' 297.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area , (ft') Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAc6s .- :.0.143 n , -4.`00 2.69 "503 465 1862 - 1184 . 288 183 0.770 'n'': 21:56: 19 31 38 0 815 Z30 : : 0 0 - .0 0 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0. 0 0 0 -G 1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 '_ D 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W " ` '13A=46cs 0.143 se 4:00 2.55 34 • 34 136 86 0 .0'. .0.. .0 13A4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 1 216 865 550 1Ao1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 0.143 w 4:00 2.55 310 237 949 603 :104 72 ; 288 183 i4fi13A4ocs A-c1onn '• 1.270 w 35:56 55.21 32 2 1140 1770 32 2 1140 1770 A5 tom-: - _ .0.770 w 21.56 .19.81, 41 . 41 880 ' 788 0 0- - 0 • .. :. 0 P 12C-Osw 0.091, 2.55 1.28 192 192 489 246 0 0 0 0 0;90: _ -. 2 32 ' :... 1446 ' AW , . - 1296 33% ,... , 297. , ... 297, , .... 266 689 F 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a). Infiltration 2887. 791 848 232 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 6 1380 3 .690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 50503 4925 15 Duct loads 32% 49% 5654 8536 32% 49%1 1601 24W Total room load 23503 26056 6653 7325 Air required (cfm) 1160 1160 328 326 Calculations approved byACCA to meet all A -ram wcrrgnzsorc Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick CaloslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 1 - - wrightsoft Right4@ Worksheet Job: • Entire House Date: sy.. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC KITCHEN 2 Btp6sed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 . Room dimensions 6.0 x 9.0 ft 1.0 x 172.0. ft 5 Room area 54.0 ftz 172.0 ftz Ty Construction U-value Or. HTM Area (ftz) r -Load Area (ftz) Load number (Btuh/ftz °F) (Btuh/ftz) or . perimeter (ft) (Btuh) or perimeter: (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs , U:143 n 0 0,. 0: r0. 0 . ;4A5 tom .'°. 0:770 rt: .. 21:56 19531 0 0 0 0 0 0 : • ., 0 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 —G E 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 0..M . se; 4:00 2:55 .' 0 0 . 0:: 0 0 0 . 0 ' 0 t13AAocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 —C 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-0ocs ", .0.143 w . 4:00 ' 2.55 : 0 0 0 0 0 01 :0 0 1A c1om 1.270 w" 3556 55:21 0` 0 0 0 0 0 0 4A5-20m . 0.770 w 21,56 19:3t 0. 0 0 0 0. W. 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C 16A30md;, r 40.032 = Oa90 2.32 54 .. 54. 48,::. 125._,. 172 -.. 172:.• ' • 399 F 22FHtpl 0.989 - 27.69 0.00 54 0 0 0 172 0 ..454 0 0 •_ f 6 c)AED erxursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration. 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less eidemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 320% 490/6 15 57 32% 49% 100 1126 Total room load 64 174 418 . 3437 Air required (cfm) 3 8 21 153 -Calculations-approved byACCA to meet all requirements of Manual J•8th Ed. -Fj�- wriilghtsoft. . 2017-Apr=11 09:29:38 AftRight-Suite® Universal 2017 17.0.14 RSUD8101 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup . Calc = MJ8 Front Door faces: N - - vvrightsoft° Right-M Worksheet Job: - Entire House bate: QUICK CALLS, INC. By. 317 ST.,LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool. 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2. Ty Construction U-value Or HTM Area 2 Load AM (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 U�/ 13A flocs ; 0143 n 4E00 2 55 40 40 160 .. 102 =.: 128r.926. 0.770. n s; 21;56 19.31 ,0 0;., .. 0.. 0, , 13AAocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 1Aclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 11DO 0.390 a 10.92 11.3.1 0 0 0 0 0 0 0 0 13446w 0.143 , se 4:00 2:55 0 0 , 0 - p . 34 34 - 196 ....86 W �--G 13AAocs 0.143 s 4.00 2.55 0 01 0 0 32 32 128 81 1A-clom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4ocs 0.143 W. 4:00 :2.55 0 0 0 0 0• 0. 40 0 1Ac1om 1:270 w 35.56 55,21 0 0 0 0 0 p, p ; .p 4A5 tom Oi770 , wr 21.56: 19.81 0 0 '. 0 0 0 _ 0 ; '0 ; 0; P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 0 0 0 C , 16A30rrrd-: *0:032' -= 090: 232 .' . ....45 •': �:45;'. 40 ; : = 104„;:.; 204:`. 20g'. 162 ;_-4 F 22A tpl . 0.989 - 27.69 0.00 45 5 138 0 204 34 6 c)AED exursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 .1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 . Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 - 5203 Air required (cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. - wrightsoft- 2017-Apr-11 09:29:38 Right -Suite® Universa12017 17.0.14 RSU08101 Page 3 ...ulck Caics%Documents\THE GRAND CARLTON•1446.rup Calc = MJ8 Front Door faces: N + wrightscift- Right4@ Worksheet • Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,10L:COM Job: Date: By: 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 _ ft 3 Room height 8.0 ft heat/cool 9.8 ft heaticool 4 . Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 W Ty Construction U-value. Or HTM Area (ft2) Load Area (ft2) Load . number (Btuh/ft2 °F) (Btu 2) or perimeter (ft) (Btuh): or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat. Cool Gross N/P/S Heat Cool 6 0;143 n 4.06 2.55 ..0 0 0 0 :: 255 ' 21Z 869 552 r , G, 4A52om .. 0.770 n~. 21;56 19.31:. 0 0 _ 0 0 38;:: 0: _ 875 :730. 13A-4ccs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .. I `13A-40cs 03143 •,'se .4.06 Z55 0 '0 0 .0 ..0 0 ; .0 0 t-G 13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A flocs 0:143 , w 4.00 2.55 0 ' 0 0 0' 206 165 . 661 420 '1Ac1om 1.270 w 3556. 55.21 .p 0 0. 0' 0. 0 0 0 4A52om .: O;770: w 21.56. 19:31 .0 0 0.: 0 41 4.1 1 : 880... i788 P 12C-0sw 0.091 2.55 1.28 56 56 143 72 0 0 0 C .. _ :1,6A 30mtl:' :. "OJ032 2 32 " : 42 ..... : 42 _ .. ' . . 36 _ ; ." 97, ..: -.t 526 ,. : :' 526 , . 471; _ 122. 0 F 22A tpI 0.989 27.69 0.00 42 6 166 0 . 526 .. 47 ..::. 1302 . bV. 12 a): Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 . 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required (ofm) 421 20 ' 390 338 Calculations approved byACCA to meet all requirements of. Manual J 8th Ed. A%�-' A -wrightscxft• 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 uick CalcslDocuments\THE GRAND CARLTON-1446.rup Cato = MJ8 Front Door faces: N -- wrightsoft RighW. 0 Worksheet -Job: Entire House °ate: QUICK CALLS, INC: By: sir 01. weir_ Irv., r 1. Mrrcie, ML 14a46 Ynone: N[-4ti6-6/99 hax 7/2-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER M. BATH 2 . Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft' Ty Construction U-value Or HTM Area (ft2) Load' Area (ft-) Load number. (Btuh/ftz'F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A1iocs. = o w n ' 4 00' 2.55 8 -8 32 20 0 "0 0 0 4A52om:,` ;0.770. n':, 21:56 19.31' p 0 0 :.. 0 ' . 0 0. 0 =:0. 13AAocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 , 0 -G IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 �D _ 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A tocs : 0.143. se. 4:00 2.55 _ 0 0 0 . 0 0 0 W 13A-0oos 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 �C 1Aclom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AAdcs`:': 0.143- w 4.W 2-W ' 0 0 0 .0 0 0 :0 -.0 1Ac1om - : 1.270 w, 35.56 55:21' .0 0 0 0 0 ` 0' 0 0 :Mf5 26m . 0:770 ;.:w,: , 21;56 19.31 0 . 0 :. 0 .: ". 0 0 0 =, 0 0. P. 12C-Osw 0.091 - 2.55 1.28 72 72 183 92 0 0 0 _ 0 C 16A-30md' ; O':032 .= ; U 90; 2 32 . 50 50 ' 45 : 116 _; ;66 r ',56 ; 56 130' F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 , c)AED mcursion. -39 �g Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal Qines 6 tQ 13) 913 529 M . 516 Less external load 0 0 0 0 Less "transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 2891 258 32% 49% 280 251 Total room load 1202 ' 787__]_F 1166 7A61 Air required (cfm) 59 35 58 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. P. wrightsOft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N g ob: - wrightsoft° Duct Systell>7 Summary oae, Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799: Fax 772-466-6796 Email:. QUICKCAL•CS AOL.COM iLroject intormation For: THE GRAND C'ARLTON WYNNE DEVELOPMENT, FT PIERCE, FL External static pressure Pressure losses Available static pressure Supply! return available pressure Lowest friction rate Actual, air flow Total effective length.(TEL) Heating. 0.50 in H2O 0 in H2O .0.50 :in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design . FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 SO BEDROOM h 4702 232 232 0.360 7.0 ox0 VIFx 23.9 115.0 st1 BEDROOMA h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 .GREATIDINING h 3946 195 169 0.300- 7.0 OxO VIFx 31.8. 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 wig c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc ' Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 9.18 12.0 0 x 0 VinlFlx st1 st-1 Peak AVF 1043 1691 0.285. 1020 . 14.0 0 x 0 VinlFlx wri ht"fta 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 �� ...uick CalcslDocumentslTHE GRAND CARLTON=1446.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg _ (cfm) Clg (cfm) TEL (ft) Design FR . Veloc (fpm) Diam (in) . H x W (in) Stud/j6ist Opening (in)_ Duct Math. Trunk rb1 Ox0. 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft, 2017-Apr-1109:29:38 ��� 9 Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 2 ... uick CalcslDocumentsl.THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N