QUICK CALCS, INC.
For. THE•GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
�` �Q �
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db. 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh
Structure
17520
Btuh.
Ducts 5654 Btuh
Ducts
8536
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
none
e)
Humidification 0 .Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 23503 Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment
0.95
Infiltration
sensible load
24753
Btuh
Method Simplified
Latent Cooling Equipment
Load
Sizing
Construction quality Average
.
Fireplaces 0,
Structure
3203
Btuh
Ducts .
2318
Btuh
Central vent (0 cfm)
0
Btuh.
Heatingg Coolingg
Area Tat
(none)
(ft2) 1446
Equipment latent load
5521
Btuh
VOlume (ft3) 12511 12511
Air changes/hour 0.45 0.23
Equipment total load
30274
Btuh
Equiv. AVF (cfm) 94 48
Req. total capacity at 0.70 SHR
. 2.9
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make Carrier
Make Carrier
Trade CARRIER AIR CONDITIONING
Trade CARRIER AIR CONDITIONING
Model 25HBC536A" 030
Cond 25HBC536A*030
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref , 7914585
Efficiency 8.5 HSPF
Efficiency 12.0 EER,
15 SEER
Heating input
Sensible cooling
24360
Btuh
Heating output 34600 @ 470F
Latent cooling
10440
Btuh
.Btuh
Temperature rise 27 OF
Total cooling
34800'
Btuh
Actual air flow -1160 cfm
Actualair flow
1160
cfm
Air flow factor 0.049 cfm/Btuh
Air flow factor
0.045
cfm/Btuh .
Static pressure 0.50 in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio .
0.83.
Capacity balance point = 32 OF
Backup:
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
t wrl hso tft` 2017-Apr-1109:29:38
.-�-. 9 Right-Suite�aJ Universal 2017 17.0.14 RSU08101 .Page 1
'�� ...uick Calcs%Documents%THE GRAND CARLTON-1446.6up Calc = MJ8 Front Door faces: N
- wrigntsoft° Right-J® Worksheet Job:
• Entire House Date:
QUICK CALCS, INC. BY:
317 ST LUCIELN., FT. PIERCE, FL 34946•Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
1
Room name
Entire. House
BEDROOM
2
FVosed wall
156.2 ft
49.0 ft
3
Room height
8.7 ft d
8.0 ft heat/cool
4
Room dimensions
1.0 x 297.0 ft
5
Room area
1445.5 ft'
297.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft')
Load
Area , (ft')
Load
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh) .
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13AAc6s .-
:.0.143
n ,
-4.`00
2.69
"503
465
1862
- 1184
. 288
183
0.770
'n'':
21:56:
19 31
38
0
815
Z30
: : 0
0
- .0
0
13A4ocs
0.143
a
4.00
2.55
128
83
333
212
0.
0
0
0
-G
1A-c1om
1.270
a
35.56
87.29
24
2
848
2082
0
0
0
0
11
'_ D
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W " `
'13A=46cs
0.143
se
4:00
2.55
34
• 34
136
86
0
.0'.
.0..
.0
13A4ocs
0.143
s
4.00
2.55
360
353
1414
899
216
1 216
865
550
1Ao1om
1.270
s
35.56
34.77
7
7
247
241
0
0
0
0
0.143
w
4:00
2.55
310
237
949
603
:104
72
; 288
183
i4fi13A4ocs
A-c1onn '•
1.270
w
35:56
55.21
32
2
1140
1770
32
2
1140
1770
A5 tom-: - _
.0.770
w
21.56
.19.81,
41
. 41
880
' 788
0
0-
- 0
• .. :. 0
P
12C-Osw
0.091,
2.55
1.28
192
192
489
246
0
0
0
0
0;90:
_ -. 2 32
' :... 1446
' AW
, . - 1296
33%
,... , 297.
, ... 297,
, .... 266
689
F
22A tpl
0.989
-
27.69
0.00
1446
156
4325
0
297
49
1357
0
6
c)AED excursion
918
627
Envelope loss/gain
14961
13349
4204
4003
12
a). Infiltration
2887.
791
848
232
b) Room ventilation
0
0
01
0
13
Internal gains: Occupants @ 230
6
1380
3
.690
Appliances/other
2000
0
Subtotal (lines 6 to 13)
17848
17520
5053
4925
Less external load
0
0
0
0
Less.transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17848
17520
50503
4925
15
Duct loads
32%
49%
5654
8536
32%
49%1
1601
24W
Total room load
23503
26056
6653
7325
Air required (cfm)
1160
1160
328
326
Calculations approved byACCA to meet all
A -ram wcrrgnzsorc Right -Suite® Universal 2017 17.0.14 RSU08101
...uick CaloslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
2017-Apr-11 09:29:38
Page 1
- - wrightsoft Right4@ Worksheet Job:
• Entire House Date:
sy..
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
WIC
KITCHEN
2
Btp6sed wall
O ft
O ft
3
Room height
8.0 ft
heat/cool
8.0 ft
heat/cool
4
. Room dimensions
6.0
x
9.0 ft
1.0
x
172.0. ft
5
Room area
54.0 ftz
172.0 ftz
Ty
Construction
U-value
Or.
HTM
Area (ftz)
r
-Load
Area (ftz)
Load
number
(Btuh/ftz °F)
(Btuh/ftz)
or . perimeter
(ft)
(Btuh)
or perimeter:
(ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A-0ocs ,
U:143
n
0
0,.
0:
r0.
0
.
;4A5 tom .'°.
0:770
rt: ..
21:56
19531
0
0
0
0
0
0
: • .,
0
0
13A-4ocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
—G
E
1Aclom
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
11
D
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
0..M
. se;
4:00
2:55 .'
0
0
.
0::
0
0
0
.
0
'
0
t13AAocs
0.143
s
4.00
2.55
0
0
0
0
0
0
0
0
—C
1Aclom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A-0ocs ",
.0.143
w .
4:00
' 2.55 :
0
0
0
0
0
01
:0
0
1A c1om
1.270
w"
3556
55:21
0`
0
0
0
0
0
0
4A5-20m .
0.770
w
21,56
19:3t
0.
0
0
0
0.
W.
0
0
P
12C-0sw
0.091
-
2.55
1.28
0
0
0
0
64
64
163
82
C
16A30md;,
r
40.032
=
Oa90
2.32
54
..
54.
48,::.
125._,.
172
-..
172:.•
' •
399
F
22FHtpl
0.989
-
27.69
0.00
54
0
0
0
172
0
..454
0
0
•_
f
6
c)AED erxursion
-9
-170
Envelope loss/gain
48
117
317
311
12
a) Infiltration.
0
0
0
0
b) Room ventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
2000
Subtotal (lines 6 to 13)
48
117
317
2311
Less eidemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
48
117
317
2311
15
Duct loads
320%
490/6
15
57
32%
49%
100
1126
Total room load
64
174
418
. 3437
Air required (cfm)
3
8
21
153
-Calculations-approved byACCA to meet all requirements of Manual J•8th Ed.
-Fj�- wriilghtsoft. . 2017-Apr=11 09:29:38
AftRight-Suite® Universal 2017 17.0.14 RSUD8101 Page 2
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup . Calc = MJ8 Front Door faces: N
- - vvrightsoft° Right-M Worksheet Job:
- Entire House bate:
QUICK CALLS, INC. By.
317 ST.,LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM
1
Room name
BATH
BEDROOM 2
2
Exposed wall
5.0 ft
34.2 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool.
4
Room dimensions
9.0 x 5.0 ft
1.0 x 203.5 ft
5
Room area
45.0 ft2
203.5 ft2.
Ty
Construction
U-value
Or
HTM
Area 2
Load
AM (ft2)
Load
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter. (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
U�/
13A flocs ;
0143
n
4E00
2 55
40
40
160
.. 102
=.: 128r.926.
0.770.
n s;
21;56
19.31
,0
0;.,
.. 0..
0,
,
13AAocs
0.143
a
4.00
2.55
0
0
0.
0
80
56
225
143
1Aclom
1.270
a
35.56
87.29
0
0
0
0
24
2
848
2082
11
11DO
0.390
a
10.92
11.3.1
0
0
0
0
0
0
0
0
13446w
0.143
, se
4:00
2:55
0
0
, 0
- p
. 34
34
- 196
....86
W
�--G
13AAocs
0.143
s
4.00
2.55
0
01
0
0
32
32
128
81
1A-clom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A4ocs
0.143
W.
4:00
:2.55
0
0
0
0
0•
0.
40
0
1Ac1om
1:270
w
35.56
55,21
0
0
0
0
0
p,
p
; .p
4A5 tom
Oi770
, wr
21.56:
19.81
0
0
'. 0
0
0
_ 0
; '0
; 0;
P
12C-0sw
0.091
-
2.55
1.28
0
0
0
0
0
0
0
0
C ,
16A30rrrd-:
*0:032'
-=
090:
232
.' . ....45
•': �:45;'.
40
; : = 104„;:.;
204:`.
20g'.
162
;_-4
F
22A tpl .
0.989
-
27.69
0.00
45
5
138
0
204
34
6
c)AED exursion
-16
-85
Envelope loss/gain
339
190
2978
3106
12
a) Infiltration .
87
24
593
162
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
.1
230
Appliances/other
0
0
Subtotal (lines 6 to 13)
425
214
3571
3498
Less extemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
. Subtotal
425
214
3571
3498
15
Duct loads
32%
49%
135
104
32%
49%
1131
1704
Total room load
560
318
4702
- 5203
Air required (cfm)
28
14
232
232
Calculations approved byACCA to meet all requirements of Manual J.8th Ed.
- wrightsoft- 2017-Apr-11 09:29:38
Right -Suite® Universa12017 17.0.14 RSU08101 Page 3
...ulck Caics%Documents\THE GRAND CARLTON•1446.rup Calc = MJ8 Front Door faces: N
+ wrightscift- Right4@ Worksheet
• Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,10L:COM
Job:
Date:
By:
1
Room name
LAUNDRY
GREAT/DINING
2
Exposed wall
6.0 ft
47.0 _ ft
3
Room height
8.0 ft heat/cool
9.8 ft heaticool
4
. Room dimensions
7.0 x 6.0
ft
1.0 x 526.0 ft
5
Room area
42.0 ft2
526.0 W
Ty
Construction
U-value.
Or
HTM
Area (ft2)
Load
Area (ft2)
Load .
number
(Btuh/ft2 °F)
(Btu 2)
or perimeter (ft)
(Btuh):
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat.
Cool
Gross
N/P/S
Heat
Cool
6
0;143
n
4.06
2.55
..0
0
0
0
:: 255
' 21Z
869
552
r , G,
4A52om ..
0.770
n~.
21;56
19.31:.
0
0
_ 0
0
38;::
0:
_
875
:730.
13A-4ccs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
1Aclom
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
11
11D0
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W .. I
`13A-40cs
03143
•,'se
.4.06
Z55
0
'0
0
.0
..0
0
; .0
0
t-G
13A4ocs
0.143
s
4.00
2.55
48
48
192
122
0
0
0
0
1Aclom
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A flocs
0:143
, w
4.00
2.55
0
' 0
0
0'
206
165
. 661
420
'1Ac1om
1.270
w
3556.
55.21
.p
0
0.
0'
0.
0
0
0
4A52om .:
O;770:
w
21.56.
19:31
.0
0
0.:
0
41
4.1
1
: 880...
i788
P
12C-0sw
0.091
2.55
1.28
56
56
143
72
0
0
0
C .. _
:1,6A 30mtl:' :.
"OJ032
2 32
" : 42
..... : 42
_ .. ' . . 36
_ ; ." 97,
..: -.t 526
,.
: :' 526
, . 471;
_ 122. 0
F
22A tpI
0.989
27.69
0.00
42
6
166
0
. 526
.. 47
..::.
1302
.
bV.
12
a): Infiltration
104
28
997
273
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
2
460
Appliances/other
0
0
Subtotal (lines 6 to 13)
643
298
5994
. 5112
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
643
298
5994
5112
15
Duct loads
32%
49%
204
145
32%
49%
1899
2490
Total room load
846
443
7892
7602
Air required (ofm)
421
20
'
390
338
Calculations approved byACCA to meet all requirements of. Manual J 8th Ed.
A%�-'
A -wrightscxft• 2017-Apr-11 09:29:38
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4
uick CalcslDocuments\THE GRAND CARLTON-1446.rup Cato = MJ8 Front Door faces: N
-- wrightsoft
RighW. 0 Worksheet -Job:
Entire House °ate:
QUICK CALLS, INC: By:
sir 01. weir_ Irv., r 1. Mrrcie, ML 14a46 Ynone: N[-4ti6-6/99 hax 7/2-466-6796 Email: QUICKCALCS AOL.COM
1
Room name
FOYER
M. BATH
2
. Exposed wall
7.0 ft
8.0 ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
Room dimensions
1.0 x 50.0 ft
7.0 x 8.0 ft
5
Room area
50.0 ft2
56.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load'
Area (ft-)
Load
number.
(Btuh/ftz'F)
(13tuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter. (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
13A1iocs. =
o w
n '
4 00'
2.55
8
-8
32
20
0
"0
0
0
4A52om:,`
;0.770.
n':,
21:56
19.31'
p
0
0
:.. 0
' . 0
0.
0
=:0.
13AAocs
0.143
a
4.00
2.55
48
27
108
69
0
0
0
,
0
-G
IA-c1om
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
11
�D
_
11D0
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W
13A tocs :
0.143.
se.
4:00
2.55
_ 0
0
0
. 0
0
0
W
13A-0oos
0.143
s
4.00
2.55
0
0
0
0
64
57
228
145
�C
1Aclom
1.270
s
35.56
34.77
0
0
0
0
7
7
247
241
13AAdcs`:':
0.143-
w
4.W
2-W
' 0
0
0
.0
0
0
:0
-.0
1Ac1om - :
1.270
w,
35.56
55:21'
.0
0
0
0
0
` 0'
0
0
:Mf5 26m .
0:770
;.:w,:
, 21;56
19.31
0
. 0
:. 0
.: ". 0
0
0
=, 0
0.
P.
12C-Osw
0.091
-
2.55
1.28
72
72
183
92
0
0
0
_
0
C
16A-30md' ;
O':032
.= ;
U 90;
2 32
. 50
50
' 45
: 116
_; ;66
r ',56
; 56
130'
F
22A-tpl
0.989
-
27.69
0.00
50
7
194
0
56
8
222
0
6
, c)AED mcursion.
-39
�g
Envelope loss/gain
792
496
747
478
12
a) Infiltration
121
33
138
38
b) Room ventilation
0
0
0
0
13
internal gains: Occupants @ 230
0
0
0
0
Appliances/other
01
0
Subtotal Qines 6 tQ 13)
913
529
M
. 516
Less external load
0
0
0
0
Less "transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
913
529
885
516
15
Duct loads
32%
49%
2891
258
32%
49%
280
251
Total room load
1202
' 787__]_F
1166
7A61
Air required (cfm)
59
35
58
Calculations approved byACCA to meet all requirements of Manual .J 8th Ed.
P. wrightsOft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 5
...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N g
ob:
- wrightsoft° Duct Systell>7 Summary oae,
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799: Fax 772-466-6796 Email:. QUICKCAL•CS AOL.COM
iLroject intormation
For: THE GRAND C'ARLTON
WYNNE DEVELOPMENT, FT PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply! return available pressure
Lowest friction rate
Actual, air flow
Total effective length.(TEL)
Heating.
0.50 in H2O
0 in H2O
.0.50 :in H2O
0.250 / 0.250 in H2O
0.285 in/100ft
1160 cfm
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.285 in/100ft
1160 cfm
176 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design .
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 560
28
14
0.364
4.0
Ox 0
VIFx
22.4
115.0
SO
BEDROOM
h 4702
232
232
0.360
7.0
ox0
VIFx
23.9
115.0
st1
BEDROOMA
h 3327
164
163
0.300
6.0
Ox0
VIFx
31.8
135.0
st2
BEDROOM-B
h 3327
164
163
0.285
6.0
Ox0
VIFx
40.6
135.0
st2
FOYER
h 1202
59
35
0.505
4.0
Ox0
VIFx
4.0
95.0
.GREATIDINING
h 3946
195
169
0.300-
7.0
OxO
VIFx
31.8.
135.0
st2
GREAT/DINING-A
h 3946
195
169
0.300
7.0
Ox0
VIFx
31.8
135.0
st2
KITCHEN
c 3437
21
153
0.379
6.0
OxO
VIFx
17.0
115.0
st1
LAUNDRY
h 846
42
20
0.361
4.0
Ox0
VIFx
23.3
115.0
st1
M. BATH -A
h 768
58
34
0
0
Ox 0
VIFx
0
0
wig
c 174
3
8
0.309
4.0
Ox0
VIFx
27.0
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
' Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
721
672
0.285
9.18
12.0
0 x 0
VinlFlx
st1
st-1
Peak AVF
1043
1691
0.285.
1020 .
14.0
0 x 0
VinlFlx
wri ht"fta 2017-Apr-1109:29:38
9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
�� ...uick CalcslDocumentslTHE GRAND CARLTON=1446.rup Calc = MJ8 Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg _
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR .
Veloc
(fpm)
Diam
(in) .
H x W
(in)
Stud/j6ist
Opening (in)_
Duct
Math.
Trunk
rb1
Ox0.
1160
1160
0
0
0
0
Ox 0
VIFx
wri htsoft, 2017-Apr-1109:29:38
��� 9 Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 2
... uick CalcslDocumentsl.THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N