Loading...
HomeMy WebLinkAboutREVISION 9-18-18o, f RECEIVED OFFICE USE ONLY: DATE FILED: (41 1 g M REVISION FEE: PERMIT # 1712-0154 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION, 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 SEP 1 8 1018 Permitting Department St. Lucie Countv APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SEFMEDITERRANEAN NORTH ADDRESS: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: MI IMPACT WINDOWS WERE INSTALLED, NOT PGT IMPACT WINDOWS 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE COUNTY CERT. #: 8898 BUSINESS NAME: orpora ion QUALIFIERS NAMED South U ui e ADDRESS: 800 wy. 402 CITY: Port St. Lucie STATE: ZIP: 1495 PHONE (DAYTIME): - FAX: 7 78-7 56 4. OWNER/BUILDER INFORMATION:, Nam, Wynne Building Corporation ADDASS: ou Wy- u CITY: PHONE: (7.72) 878-5513 5. ARCHITECT/ENGINEER INFORMATION: NAME: BRADEN & BRADEN ADDRESS: CITY: STUART PHONE (DAYTIME): (772) 287-8258 Revised 07/22/2014 FAX: ZIP: ZIP: -File cw 3ADEN, A. I. A., P. A. Sqrchikecb & 'Planners 417 COCONUT AVENUE, STUART, FLORIDA 34996 TELEPHONE: (772) 287-8258 FAX (772) 287-8283 #AAC-000032 RECEIVED THESE PLANS AND ALL PROPOSED WORK z �S ARE SUEdECTTOANY CORRI OPEO.2018 REQUIRED BY FIELD INSPECTORS THAT e ST LLCIE COUNICY B LLD 'r i is L 'C1 MAYBE W �6�AIN PPLICABt IL�aDE�Ounty REVIENAID FOR 1 E COMPLY 1 TH REVIENVED ' DATE PLANS Al�'D PER_ ITT AiUST BE KEPT OBI JOB cot i INSPECTION NVILL BE MADE. 9-18-18 Please note, brand of windows installed in this residence are as follo s lieu of what was shown on the plans. SInc erteW. nie Braden Braderil t Braden AIA PA St. Lucie County Building Department Re: Wgnne Development Address: 82 Mediterranean North Permit#: 1-112-0154 Product Approval Submittal Affidavit Opening Schedule Swing Door°. Overhead Door. Sliding Doors. 18nduw. & Skylights opening Type NORM NUMBER Product yodel ¢ Manufacturer class Attachment method F�niratioa Date D°°!a° Pressure of Approved Tents t2.3 FLt I I499.1 Single Hung Senes 185 ar�d° a s r °x°r"0' i e • sdi �n m cnw�.�c. a 60 pd A n-1108.30 Overhead Garage Door h el 824/811 9 - • ssx wdth 14. suuc Mght DAB .a• L� d v.r. _ +,,, ,. ,,,,� 10-9-21 + 50.0/-40.0 par B FLU 14414.1 Fiberglass oS= Pro Jold-Wan We VS • d.. .rth .n l ssbsd.nrt. at 3' sor r''a' c°r^•r• °"o • °a 'ec tMr'ah"' m J& °"E + 50.0 PSF C FLtt 22401.3 Sliding Glass Door Senaa 100 Mi dWi cue °In net � 'p�.!�.�r,��i ., .ems �.�a � � -' `� R ± 48.2 PSF P�„ct NOA/FL NUMM Model 0 Manufacturer Attachment Method TESTT ih<airaticn Dais D=pp Pt'0°°"rB of Approved Testa Mullions FLU 15353.8 CM-18531 vertical mullion Mi i dame and doors For CMU use (2) V4' x 2 3/4• tapcma.wth - I V4' ssbadssnt owenaratran into sack Nuo Cip. Attach r0 to cbp usrp (4) 810 x Me sea taAPxp sorest W 4 as shown m product approval. ± 118.9 PSF Roof FLU 11651.12 5V Crimp Metal Rooting Gulf Coast Su I and manufacturing iLoo�° Sv s�c � r U` n a�sax �+a� w.�r AS�M D tp.��30 lb sit ud.r�l*—t mst.1 it 4 lap. and t}wNd wt� conroran nr.tantsscaldu a�'wjh2S• myiwd� rim �..�`.. o tru&r at a . " and too raw H o.c n f e mop t.dasat d.tr an sad pl.n - 108.5 PSF Siding stucco an Block Soffit FLU 12198.3 Modal T4 12' vented Vinyl Soffit Kaycan InstaO using 2' x 2' battens at L' o.c. seemed to sdfnt fra.ung umg ae x 3' mcad fcnus at tech tons Irutayoth tit to battens -09 +55.0/-35.0 PSF Hurricane Panels I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record ) Yr-lt�.r �.PY n ..i+s�•4i _ ram. •7* ``' to FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: YNNE,�THE .GRAND CARL ON IMPACT - Builder Name: WYNNE BUILDING COPR. Street: k� '� ^�� Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1445.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and ST,gT� this calculation are in compliance with the Florida Energy specifications covered by this O�-C$E Code. calculation indicates compliance <O with the Florida Energy Code. rrn,.a. ,'•, •,.,. ;,•°�,< PREP D DATE: - Before construction is completed this building will be inspected for compliance with Section 553.908 * "' I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Cod wr, OWNER BUILDING OFFICIAL: DATE: "� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Insp li nhan rft.10102.4.1.1 and this project requires an envelope leakage test report with envelope leakage no g a 5( 4 File Copv 9/18/2018 8:06 AM EnergyGaugel RECEIVED EP 18, 2010 itting Department Lucie County Page 1 of 5 FORM R405-2017 INPUT 5UMMAKY GHtGKLI5 I KtPUK I PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---- 0 1 0 9/18/2018 8:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 PnRnn Ranr,_9nl7 INPI IT CI IMMARY CHFCKI IRT RFPnRT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC IRCC V # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar BeloA w Ornt 10 Wall Type SpaceR-\/;;I,le Ft n Et sor1 NE=>SW Exterior Concrete Block - Ext InsiBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsfilEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsdHEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InEBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InstIIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGiREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 9/18/2018 8:06 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS V F# Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in 0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 9/18/2018 8:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS --- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun Jul Au Se Oct [ ] Nov [ Dec Heating Jan f Xj Feb X� MarAprfMay 4 Jun Jul rj Au�xj rj SeP Oct [X] Nov [XDec lX Ventin [ Jan [ Feb [X Mar [X A r [ Ma [ Jun Jul Aug Se [X Oct [X] Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 ENTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default 8 Ibs/s .ft. ft2 ft 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater Wo M01111 �m Woram mkomi 0� —0,7 �,f )I Date: 9/18/2018 8:06 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting I Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pwp*ng and wwring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o l The air barrier shall be installed behind electrical or communication exterior walls 7 boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be I sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire spripklpr cover plates and walls or ceffilffings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/18/2018 8:07 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 141.3 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 8a. NA 8b. NA 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 10131. 11.0 10132. 11 a. 30.0 11 b. 11 c. 11 d. No 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: PI RCE FL :3 c 9/18/2018 8:07:02 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Wynne Building Corporation RECEIVED SEP 18 1018 Permitting Department St. Lucie Countv September 18, 2018 To: St. Lucie County Building Dept. Attn: William Durden Re: 82 Mediterranean North Permit # 1712-0154 Hi William, I am sure you will remember this nightmare we went through, where I submitted revisions to install PGT Impact Windows on our homes but then the window company decided to use up what they had in stock of MI Impact Windows?! Well I guess this is one that got missed along the way and was just realized when we failed an inspection. So here is the letter from Braden & Braden and the correct Energy Calcs to go from PGT Impact to the MI Impact. Let me know if you have any questions (772) 20�,l Thanks • Cheri File