HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESF
7/26/2016
Florida Building Code Online
g
yj
F oMa DeparUnEntn# BCIS Home Log In User Registration Hot Topics
Submit Surcharge j Stats & Facts
Publications FBC Staff j BCIS Site Map Links j Search j
Busines r}
Professi al .s 5 U5 R PubuAUser l
Regulation
Product Aooroval Menu > Product or Application
Search > Application List > Application Detail
/ FL #
'm
FL7804-R9
M
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer Entegra Roof Tile, Inc,
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(863) 467-0042 Ext 1228
tjohnson@rooftile.com
Authorized Signature Terry Johnson
tjohnson@rooftile.com
Technical Representative Jim Deyarmond
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(863) 467-0042
JDeyarmond@rooftile.com
Quality Assurance Representative Terry Johnson
Address/Phone/Email 819 South Federal Hwy Suite 300
Stuart, FL 34994
(800) 586-7663
tjohnson@rooftile.com
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/04/2016
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard
ASTM C1492
FRSA/TRI April 2012
SSTD 11
TAS 100
TAS 101
TAS 102
TAS 102(A)
https://www.floridabuilding.org/pr/pr_app dfl.aspx?param=wGEVXQwtDquovOjOHI°/p2bAMgsl79p/`2bkb9MWlggi8oylmr8%3d
Year
2003
2012
FjX5C®py
1995
1995
1995
1/2
J'
7/2612016
Florida Building Code Online
TAS 112 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/24/2016
Date Approved 06/08/2016
Summary of Products
FL #
Model, Number or Name
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
Concrete Roof Tile
jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.Ddf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 HVHZ.odf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
Concrete Roof Tile
HVHZ jurisdictions)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Evaluation Reports
Section 6 for Installation.
FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804-
R9 NON-HVHZ.Ddf
Created by Independent Third Party: Yes
CSack WexC
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
Wiilll
eCG!k
Credit Card
Safe
https://www.fforidabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bAMgs179%2bkb9MWl<igi8oylmr8%3d 212
EVALUATION REPORT
Entegra Roof Tile, LLC
1289 NE 9th Avenue
Okeechobee, FL 34972
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization N9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report E39310.11.11-2-R3
FL7804-RB
Date of Issuance: 11/02/2011
Revision 3 : 07/15/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (non-HVHZ) sections noted
herein.
DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nleminen,
P.E, on 07/15/201S. This does not serve as an electronically signed
document. Signed, sealed hardcopies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with
the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.3.5, R905.3.5
Physical Properties
ASTM C1492
2003
1507.3.7, R905.3.7
Attachment Requirements
FRSA/TRI April 2012 (04-12)
2012
1711.2.1
Overturning Moment
SSTD 11
1997
3. REFERENCES:
Entity
Examination
Reference
Date
PRI (TST5878)
ASTM C1492
ESI-001-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-002-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-003-02-01
11/06/2006
PRI (TST5878)
ASTM C1492
ESI-004-02-01
11/06/2006
PRI(TST5878)
ASTM C1492
ESI-005-02-01
12/12/2006
ATL(TST3782)
ASTM C1492
RT0615.01-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.02-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.03-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.04-11
06/28/2011
ATL(TST3782)
ASTM C1492
RT0615.05-11
06/28/2011
Tile Roof Institute
SSTD it
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Inspection Report
11/04/2015
4. PRODUCT DESCRIPTION:
4.1 BERMUDA FLAT and PLANTATION FLAT are ASTM C1492, Type III (low -profile) concrete roof tiles
Bermuda Flat
Exterior Research and Design, LLC.
Certificate of Autharization #9503
Plantation Flat
Evaluation Report E39310.11.11-2-R3
FL7804-RB
Revision 3: 7/15/201S
Page 2 of 4
4.2
4.3
TTRINITYIERD
BELLA HIGH "S" and ESTATE "S" are ASTM D1492, Type II (medium -profile) concrete roof tiles.
tseua nlgn __s.
GALENA SPANISH "S" are ASTM C1492, Type I (high -profile) concrete roof tiles.
17"
S. LIMITATIONS:
Galena Spanish "S"
10"
tstate "S"
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing
Materials Directory for fire rating of this product.
5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for
use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation
(mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or
adhesive -set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the
underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12).
5.5 Attachment:
5.5.1 For mechanically attached tiles, attachment for wind load resistance shall be in accordance with Table 3 of the FRSA/TRI
April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12).
5.5.2 For mortar -set or adhesive -set tiles, attachment for wind load resistance shall be in accordance with FBC Section
1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval.
5.5.3 Hip and ridge tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations
atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report
in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April
2012 (04-12).
Exterior Research and Design, I.L.C. Evaluation Report E39310.11.11-2-R3
Certificate of Authorization #9503 FL7804-R8
Revision 3: 7/15/2015
Page 3 of 4
Q0
TRINITYiERD
5.7 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and
F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with
manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3, the FRSA/TRI
Florida High Wind Concrete and Clay Tile Installation Manual, 5th Edition and, for mortar -set or adhesive -set applications,
the mortar or adhesive manufacturer's Product Approval.
7. LABELING:
7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in
accordance with the requirements of the Accredited Quality Assurance Agency noted herein.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 61G20-3 CIA requirements.
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC.—QUA9110; (813) 621-5777
- END OF EVALUATION REPORT -
Exterior Research and Design,LLC.
Certificate of Authorization #9503
Evaluation Report E39310.11.11-2-R3
FL7804-R8
Revision 3: 7/15/2015
Page 4 of 4