Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESF 7/26/2016 Florida Building Code Online g yj F oMa DeparUnEntn# BCIS Home Log In User Registration Hot Topics Submit Surcharge j Stats & Facts Publications FBC Staff j BCIS Site Map Links j Search j Busines r} Professi al .s 5 U5 R PubuAUser l Regulation Product Aooroval Menu > Product or Application Search > Application List > Application Detail / FL # 'm FL7804-R9 M Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Entegra Roof Tile, Inc, Address/Phone/Email 1289 NE 9th Avenue Okeechobee, FL 34972 (863) 467-0042 Ext 1228 tjohnson@rooftile.com Authorized Signature Terry Johnson tjohnson@rooftile.com Technical Representative Jim Deyarmond Address/Phone/Email 1289 NE 9th Avenue Okeechobee, FL 34972 (863) 467-0042 JDeyarmond@rooftile.com Quality Assurance Representative Terry Johnson Address/Phone/Email 819 South Federal Hwy Suite 300 Stuart, FL 34994 (800) 586-7663 tjohnson@rooftile.com Category Roofing Subcategory Roofing Tiles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 11/04/2016 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL7804 R9 COI 2016 01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard ASTM C1492 FRSA/TRI April 2012 SSTD 11 TAS 100 TAS 101 TAS 102 TAS 102(A) https://www.floridabuilding.org/pr/pr_app dfl.aspx?param=wGEVXQwtDquovOjOHI°/p2bAMgsl79p/`2bkb9MWlggi8oylmr8%3d Year 2003 2012 FjX5C®py 1995 1995 1995 1/2 J' 7/2612016 Florida Building Code Online TAS 112 1995 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/24/2016 Date Approved 06/08/2016 Summary of Products FL # Model, Number or Name Description 7804.1 Entegra Concrete Roof Tiles (HVHZ Concrete Roof Tile jurisdictions) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804- R9 HVHZ.Ddf Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804- R9 HVHZ.odf Created by Independent Third Party: Yes 7804.2 Entegra Concrete Roof Tiles (non- Concrete Roof Tile HVHZ jurisdictions) Limits of Use Installation Instructions Approved for use in HVHZ: No FL7804 R9 II 2016 04 FINAL ER ENTEGRA FL7804- R9 NON-HVHZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Refer to ER Evaluation Reports Section 6 for Installation. FL7804 R9 AE 2016 04 FINAL ER ENTEGRA FL7804- R9 NON-HVHZ.Ddf Created by Independent Third Party: Yes CSack WexC Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Wiilll eCG!k Credit Card Safe https://www.fforidabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bAMgs179%2bkb9MWl<igi8oylmr8%3d 212 EVALUATION REPORT Entegra Roof Tile, LLC 1289 NE 9th Avenue Okeechobee, FL 34972 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization N9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report E39310.11.11-2-R3 FL7804-RB Date of Issuance: 11/02/2011 Revision 3 : 07/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code (non-HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (non-HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E, on 07/15/201S. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5, R905.3.5 Physical Properties ASTM C1492 2003 1507.3.7, R905.3.7 Attachment Requirements FRSA/TRI April 2012 (04-12) 2012 1711.2.1 Overturning Moment SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date PRI (TST5878) ASTM C1492 ESI-001-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-002-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-003-02-01 11/06/2006 PRI (TST5878) ASTM C1492 ESI-004-02-01 11/06/2006 PRI(TST5878) ASTM C1492 ESI-005-02-01 12/12/2006 ATL(TST3782) ASTM C1492 RT0615.01-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.02-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.03-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.04-11 06/28/2011 ATL(TST3782) ASTM C1492 RT0615.05-11 06/28/2011 Tile Roof Institute SSTD it Membership Confirmation Current PRI (QUA9110) Quality Assurance Inspection Report 11/04/2015 4. PRODUCT DESCRIPTION: 4.1 BERMUDA FLAT and PLANTATION FLAT are ASTM C1492, Type III (low -profile) concrete roof tiles Bermuda Flat Exterior Research and Design, LLC. Certificate of Autharization #9503 Plantation Flat Evaluation Report E39310.11.11-2-R3 FL7804-RB Revision 3: 7/15/201S Page 2 of 4 4.2 4.3 TTRINITYIERD BELLA HIGH "S" and ESTATE "S" are ASTM D1492, Type II (medium -profile) concrete roof tiles. tseua nlgn __s. GALENA SPANISH "S" are ASTM C1492, Type I (high -profile) concrete roof tiles. 17" S. LIMITATIONS: Galena Spanish "S" 10" tstate "S" 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire classification is not part of this evaluation; refer to FBC Section 1505, Exception 2 or current Approved Roofing Materials Directory for fire rating of this product. 5.4 Underlayment shall be that approved by Entegra Roof Tile, which holds Florida Local or Statewide Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 5.5 Attachment: 5.5.1 For mechanically attached tiles, attachment for wind load resistance shall be in accordance with Table 3 of the FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12). 5.5.2 For mortar -set or adhesive -set tiles, attachment for wind load resistance shall be in accordance with FBC Section 1609.5.3 in conjunction with the mortar or adhesive manufacturer's Product Approval. 5.5.3 Hip and ridge tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12). Exterior Research and Design, I.L.C. Evaluation Report E39310.11.11-2-R3 Certificate of Authorization #9503 FL7804-R8 Revision 3: 7/15/2015 Page 3 of 4 Q0 TRINITYiERD 5.7 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC Section 1507.3, the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual, 5th Edition and, for mortar -set or adhesive -set applications, the mortar or adhesive manufacturer's Product Approval. 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 61G20-3 CIA requirements. 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, LLC.—QUA9110; (813) 621-5777 - END OF EVALUATION REPORT - Exterior Research and Design,LLC. Certificate of Authorization #9503 Evaluation Report E39310.11.11-2-R3 FL7804-R8 Revision 3: 7/15/2015 Page 4 of 4