HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTFL #
FL9777-R4
Application Type
Revision
Code Version
2014
lad
Application Status
Approved
�/
ST. LiJCIT, i-II DT'N
Comments
REVIEWED FOR CoL�+" N
Archived
REVIEWED Bi
DATE '•-` l4'�
PLAN And PERNUT 'MUST BE KEPT ON JOB
Product Manufacturer
Owens Corning
WILL BE BLADE.
Address/Phone/Email
One Owens Corning
Parli;�RyNO INSPECTION
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
t' Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
THESE PLANS AND ALL PROPOSED WORK
the Evaluation Report
ARE SUBJECT TO ANY CORRECTIONS
Florida License
PE-74021
REQUIRED BY FIELD INSPECTORS THAT
Quality Assurance Entity
UL LLC
MAY BE NECESSARY IN ORDER TO
Quality Assurance Contract Expiration Date
12/31/2020
COMPLY WITH ALL APPLICABLE CODES.
Validated By
Locke Bowden
CJ- Validation Checklist - Hardcopy Received
Certificate of Independence FL9777 R4 COI OCR14002.1 FBC 2014 Evaluation Report 2010 FBC
Weatherl-ock.odf
Referenced Standard and Year (of Standard) Standard
ASTM D 1970 CONCEALED FASTENERS OR ATTARPI S
ARE THE RESPONSIBILITY OF THE
Equivalence of Product Standards CONTRACTOR OF RECORD
Certified By
Sections from the Code
File Copy
https://floridabuilding.org/pr/Pr_app dtl.aspx?param=wGEVXQwtDgtgkcMGblcW71%2tZr7gdugvKmDj6kDHt6tY%3d
112
6/30/2015 Y
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Prnducfc
Florida Building Code Online
Method 1 Option D
02/23/2015
02/24/2015
03/01/2015
04/15/2015
0
FL #
Model, Number or Name
Description
9777.1
Weatherlock G
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R4 II OCR14002.1 FBC 2014 Evaluation Reoort 2010
FBC WeatherLock.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R4 AE OCR14002.1 FBC 2014 Evaluation Reoort
2010 FBC WeatherLock.Ddf
Created by Independent Third Party: Yes
9777.2 Weatherlock MAT
Waterproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R4 II OCR14002.1 FBC 2014 Evaluation Report 2010
FBC WeatherLock.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use,
Evaluation Reports
FL9777 R4 AE OCR14002.1 FBC 2014 Evaluation Report
2010 FBC WeatherLock.odf
Created by Independent Third Party: Yes
9777.3
Weatherl-ock Specialty Tile & Metal
Weatherproofing Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9777 R4 II OCR14002.1 FBC 2014 Evaluation Report 2010
FBC WeatherLock.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL9777 R4 AE OCR14002.1 FBC 2014 Evaluation Report
2010 FBC WeatherLock.Ddf
Created by Independent Third Party: Yes
El i'IBXt.
Contact Us :: 1940 North Monroe Street, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
SMUrit'nsa malts'
. y ,
https://floridabuilding.org/prlpr_app dtl.aspx?param=wGEVXQwtDgtgkcMGblcW71%2fZr7gdugvKmDj6kDHt6tY%3d 2/2
1
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www.owenscorning.com
Manufacturing Location: Brentwood, NH
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.2.4, 1507.2.8, 1507.2.9.2,
1507.7.3, 1507.7.3.2,
Properties:
Physical properties
REFERENCES
2014 FLORIDA BUILDING CODE
Issued February 23, 2015
1507.3.3, 1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2,
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
NEI-039-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
NEI-042-02-01 REV2
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI-045-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049)
NEI-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI-053-02-01
ASTM G 155
2005a
PRI Construction Materials Technologies (TST6049)
NEI-093-02-02
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049)
OCF-213-02-01
ASTM D 1623
2009
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock@ WeatherLock@ Specialty is an ASTM D 1970 self-adhesive underlayment constructed
Specialty Tile & Metal from SBS modified asphalt and surfaced with a non -woven polyester fabric. The product
is supplied in 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft and 2.14 sq. rolls with
OCR14002.1 FL9777-R4_ Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
s
;. GREED
TECHNICAL SERVICES, LLC
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
nominal dimensions of 3-ft x 71.3-ft.
WeatherLock® WeatherLock® Specialty Tile & Metal is permitted to be used with mechanically fastened
Specialty Tile & Metal asphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes or
(continued) shingles, and slate roofing as prescribed in the FBC. WeatherLock® Specialty Tile &
Metal is permitted to be used with adhered clay or concrete tile roofing using either 3MTM
2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BONDTm Roof
Tile Adhesive (The Dow Chemical Company) up to a maximum design pressure of -45
psf and in accordance with the system approval. Exposure on the roof deck shall be
limited to a maximum 90 days.
The maximum roof slope shall be 6:12 when used with clay or concrete tile installations
without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
PRODUCT APPLICATION
Min. Roof Slope: 2:12 or in accordance in with FBC
Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed direct -to -plywood decking with the release backer
removed and pressed firmly into place to ensure complete contact with the deck. The
underlayment shall be installed with the roll length parallel to the eave, starting at the
eave, and with minimum 3" side laps and minimum 6" staggered end laps. End laps for
WeatherLock® Specialty Tile & Metal shall be primed with ASTM D 41 primer or sealed
with asphalt roof cement a minimum of 3-4 inches across the width of the lap.
It is permissible to nail the underlayment 18-inches on -center as needed (nails shall be
installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). WeatherLock® Specialty Tile & Metal shall be back nailed when
installed on roof slopes greater than 3:12.
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection, the underlayment should
extend to a point 24-inches inside the exterior wall.
The underlayment shall be installed over metal drip edge at the eave, and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC product approval documents.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
OCR14002.1 FL9777-R4 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida
Building Code as evidenced in the referenced documents submitted by the named manufacturer.
No 74021
� r
:ir;
��'.•• S TAT E OF , : mowAl
CERTIFICATION OF INDEPENDENCE
2015.02.2
3 14:45:39
-05'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
OCR14002.1 FL9777-R4 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.