HomeMy WebLinkAboutPRIODUCT APPROVAL ROOFING UNDERLAYMENTSFloridauilding:G;ode Online - Page
PC
r -
d♦ � y
BCIS Horne Log In user Registration HotTopks SubinitSutcha*e StatS & Fads Publications ; FBe stafr l BUSSite Map {. Links i Search
Florida
d',
(Yxfi! Product Approval
r
USER: Public User
s r s L
`product Approval Menu.>: Product or Application
Search > Aoolita[ion UR a Appl"ual3oa Detail
1VFl,
#
F 18686-R1
Application Type
Editorial Change
Code Version
2014
Application Status
Approved
*Approved Iby DBPR. Approvals by DBPR shall be reviewedand ratified
by the POC and/or the-Corimission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance. Method
Evaluation Entity
Quality -Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced"Standard-and Year(of standard)'
Equivalence of Product; Standards
Certified By
Sections, from the Code
Product Approval Method
it
GAF
i Campus: Drive
Padsppany, NJ 0,7054
(800) ,766-3411
instieh@gaf.com
—1 C 6
ST. LUCIE C LIN Y ELTEDING DPMION
Michael Stieh
mstieh@gaf.com:
}REVIEWED FOR CO
REVIEWEDY
Beth McSorley
DATE ` Dee- e► 2 . aw-7
136EAlps Road
PLANS AND PEFt. IT MUST BE XZPT ON JOB
Wayne, NJ 07470
OR NO INSPECTION WILL BE MADE.
(800) 365-7353
tirricsoriey@Jauom
Roofing
Underlayments.
Evaluation Reporf:from a Product Evaluation Entity
Miami -Dade BCCo = EVL.
Miami-Dade"BCCO = cER
02/21/2018
Mlami-Dade BCCO - AL
S ndar
ASTM 0226
Method 1 Optlon.t
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO QNYOORRECTIONS
REQUIRED BY FIELD INspg1roff THAT
MAYBE NECESSARY IN 090EW TC
COMPLY WIM ALL APP41CABLE C(
Xopmr
CONCEALED FAaTF:NEggon ATTACHj,,gjNTS
A4E T41ce AE3F0'4SIDi4.i"f 11, THE
CONTRACTOR OF RECORD
�tfp;//www.flbrida File Copyj
building:org/pr/Px_aPP dtI.aspx?P =wGEvX'QwtDgUIGt g S
bCxRsc...
1/19/2017
Florida.$uilding C9de Online:
41- 1 `1 1 Z - 0
Date Submitted 16/30/2015
Date Validated 10/30/2015
Date Pending FBC Approval
Date Approved 11/03/2015
Summarvof. products
Page 2 of
FL #
Model, Number or Name
Description.
18686.1
FeitBuster
High Traction Synthetic Roofing.Felt
Limits of Use
Installation Instructions
Approved foruse in HVHZ: Yes,
FL18686 RI Ti NOA 14=0915.02.0df
Approved for use outside HVHZ.•-Yes
Verified. By; Miami -Dade BCCO 7 EVL
IinpactResistant: No
Created.bySndependentThird Party:
Design Pressure:.N/A
Evaluation Reports
Other:
FL18686 Rl AE NOA' 1409i5:02.odf
Back Nekt
Contact Us :: �60' Blair �+onERoad-TaOaha«ee"FC 32399 Phone: nso-487-1a24
The State of FlaNdais an AA/ffD employer- Coov6aht200i-2013 State of FloNda :i Privacy SlatemenEt: Accessibility Statement'::'.Hefund Statement
Under Florida law, email'addressesare public records: Ifyou do not wantyour e-mail address released4mresponse to -a �pdtilierecords request, do.not send
electronic mall to this entity-. Instead,contact the office by phone or by traditional maitt-If you have any questions, please contact 850:487.1395. -Pursuant to
Section 455.27s(1), FloRda Statutes, effective:Odober. 1, 2012, licensees licensed under Chapter 455, m must provide the Department with.an email address if
they have one. The emalls provided, maybe used foe of0cla(6ommunitatlon with the licensee. However email addresses are public record. If you do.noi Wan to
supply a personal address, please:provide the Deparbrient.with in _email address which can be made ava8atile to the public. To determine if you are a• licensee under
.Product ApprovalAccepts:
iMizi 0
Credit
Safe
securitYNIE•ralcs
http://www.floridabu lding:org/pr/pr_app`tl.asi)x?param=wGEVXQWtI)quIGtg5bCXRsc... 1/19/2017
C�aU1�`i°
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NO
GAF
1 Campus Drive
Parsipanny, NJ 07054
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Leak Barriers and Roof Deck Protection
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-1104.11 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
Rf
NOA No.: 14-0915.02
Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS/Polypropylene/Asphalt
PRODUCTS DESCRIPTION:
Product
WeatherWatch®
Mineral Surfaced Leak
Barrier
Manufacturing
Location #2, 3
Test
Dimensions Specification
Product
Description
36" x 50' rolls ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
36" x 66.7' rolls ' bituminous sheet material for use as a leak barrier
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
WeatherWatch®XT 36" x 50' rolls
ASTM D 1970 Mat surfaced modified, fiberglass reinforced
Mat Surfaced Leak 36" x 66.7' rolls
bituminous sheet material for use as a leak barrier
Barrier
underlayment in sloped roof assemblies.
Manufacturing
Designed as an ice & rain shield.
Location #3
StormGuard® Film 36" x 66.7' rolls
ASTM D 1970 Modified, fiberglass reinforced, bituminous sheet
Surfaced Leak Barrier
material for use as a -high temperature leak barrier
Manufacturing
underlayment in sloped roof assemblies.
Location #2
Designed as an ice & rain shield.
LibertyTM SBS Self- 39 3/8" x 66' rolls ASTM D 1970 Self -adhering SBS roof membrane.
Adhering Base/Ply
Sheet
Manufacturing
Location #2
UnderRoofTm 2 393/8" x 67.8' rolls
ASTM D 1970 Self -adhering reinforced membrane of SBS
Polyester -Surfaced
modified asphalt with polyester surfacing for use
Leak Barrier
with asphalt shingle roof assemblies. Roof slopes
Manufacturing
of 2:12 —12:12 are acceptable as indicated by
Location #1, 3
local codes and manufacturer's installation
instructions..
UnderRoof" HT High 393/8" x 61.0' rolls
ASTM D 1970 Self -adhering reinforced membrane of SBS
Temperature Leak
modified asphalt with polyester surfacing for use
Barrier
as a high temperature underlayment in sloped
Manufacturing
metal and asphalt shingle roof assemblies. Roof
Location #3
slopes of 2:12 —12:12 are acceptable as indicated
by local codes and manufacturer's installation
instructions.
NOA No.: 14-0915.02
Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 2 of 8
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Deck-ArmorTM
54" x 222' rolls
ASTM D 226
A UV -stabilized polypropylene breathable
Premium Breathable
48" x 100' rolls
Type II
underlayment. To be used for roof deck
Roof Deck Protection
protection as an underlayment in sloped roof
Manufacturing
assemblies.
Location #4
Tiger PawT' Roof Deck
48" x 250' rolls
ASTM D 226
A UV -stabilized polypropylene non -breathable
Protection
48" x 100' rolls
Type II
underlayment: To be used for roof deck protection
Manufacturing
as an underlayment in sloped roof assemblies.
Location #5, 8, 9
FeltBuster° High-
48" x 250' rolls
ASTM D 226
A UV -stabilized polypropylene non -breathable
Traction Synthetic
Type I
underlayment. To be used for roof deck protection
Roofing Felt
as an underlayment in sloped roof assemblies.
Manufacturing
Location #10
Shingle -Mate® Roof
36" x 144' rolls
ASTM D 226
Fibergass-reinforced asphalt felt underlayment. To
Deck Protection
Type I
be used for roof deck protection as an
Manufacturing
underlayment in sloped roof assemblies.
Location #6, 7
MIAMI•DADE COUNTY
NOA No.: 14-0915.02
• • •. , Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 3 of 8
MANUFACTURING LOCATION:
1. Fresno, CA
2. Mt. Vernon, IN
3. North Branch, NJ
4. North Bay, Ontario
5. Mission, British Columbia
6. Pryor, OK
7. McGregor, TX
8. Qingdao, China
9. Charleston, SC
10. Spartanburg, SC
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Intertek Testing Services NA Ltd.
3077464-01
ASTM D 1970
08/23/06
3090131
Wind Uplift and Self Sealability
08/23/06
100258583COQ-010A
ASTM D 226 Type II
01/11/11
100673818COQ-003
ASTM D 226 Type II
06/13/13
10157289000Q-005
ASTM D 226 Type II
04/17/14
PRI Construction Materials
RGM-023-02-01
ASTM D 4798
05/16/07
Technologies, LLC.
GAF-112-02-01
ASTM D 226 Type II
03/15/06
GAF-238-02-01
ASTM D 1970
03/03/10
GAF-323-02-01
ASTM D 1970
11/30/11
GAF-324-02-01
ASTM D 1970
11/30/11
GAF-325-02-01
ASTM D 1970
11/30/11
GAF-326-02-01
ASTM D 1970
11/30/11
GAF-275-02-01
ASTM D 1970
11/11/10
GAF-344-02-01
ASTM D 1970
04/23/12
GAF-339-02-01
ASTM D 226 Type 1
03/14/12
ELK-311-02-01
ASTM D 1970
09/11/07
GAF-446-02-01
ASTM D 226 Type I
09/26/13
GAF-518-02-01
ASTM D 226 Type I
06/04/14
N
MIAMI•DADE COUNTY OA No.: 14-0915.02
�LI• • • , , Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 4 of 8
APPROVED ASSEMBLIES:
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
i
System E (1): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-ArmorT' Premium Breathable Roof Deck Protection, FeltBuster®
High -Traction Synthetic Roofing Felt, or Tiger PawTm Roof Deck Protection with a minimum 4"
side lap and a 6" end lap mechanically fastened to the deck with approved nails and tin caps 6"
o.c. at the laps and four staggered rows 12" o.c, in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch®XT Mat
Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, or LibertyTM SBS Self -
Adhering Base/Ply Sheet membrane with a minimum 3" side lap and 6" end lap. Place the first
course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release membrane as the membrane is applied. Vertical strapping of the roof with
WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch®XT Mat Surfaced Leak Barrier,
or StormGuard® Film Surfaced Leak Barrier is acceptable.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood.plank
System E(2): Membrane mechanically fastened to deck.
Separator Sheet: One or more plies of GAF GAFGLAS® Ply 4, GAFGLAS® Flex-P1yTM 6, Rosin Paper, ASTM D
226 Type I or Type II, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium
Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger
PawTM Roof Deck Protection loose laid.
Membrane: One or more plies of WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch®XT Mat
Surfaced Leak Barrier, StormGuard® Film Surfaced Leak Barrier, or LibertyTM SBS Self -
Adhering Base/Ply Sheet membrane mechanically fastened with a minimum 3" side lap and a 6"
end lap to deck through the separator sheet with approved nails and tin caps 6" o.c. at the laps
and two staggered rows 12" o.c. in the field of the roll.
Surfacing: Approved Roofing Assembly.
NOA No.: 14-0915.02
Q-Da�� CouNnr Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 5 of 8
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (3): Anchor sheet mechanically fastened to deck, membrane adhered.
Secondary Water Install a minimum 4" wide WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch®XT
Barrier: Mat Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier membrane over the
(Optional) ' joints of the plywood roof deck prior to installation of the base sheet. Do not overlap end or side
joints. All side and end laps should be butted firmly side by side, flush with each other but not
overlapped. Do not leave the WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch®
XT Mat Surfaced Leak Barrier, or StormGuard® Film Surfaced Leak Barrier membrane exposed
for more than 30 days without a roof deck protection underlayment protecting the secondary
water barrier.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck-Armoi ' Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger Pawl' Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fasteners.
Surfacing: Approved Roofing Assembly.
Deck Type 1: Wood, non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E (4): Anchor sheet mechanically fastened to deck, membrane adhered.
Base Sheet: Two plies of ASTM D 226 Type I or Shingle -Mate® Roof Deck Protection OR one or more plies
of ASTM D 226 Type II, Deck -Armor' Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, or Tiger Paw' Roof Deck Protection with a
minimum 4" side lap and a 6" end lap mechanically fastened to the deck with approved nails and
tin caps 6" o.c. at the laps and four staggered rows 12" o.c. in the field of the roll.
If roof is exposed to rain/snow, tape all end and side laps with approved butyl adhesive based
seam/cover tape or an approved waterproof cloth duct tape (follow the tape's manufacturer's
installation instructions). Always apply tape over all fasteners at the center of the roll or the end
laps to help prevent rain or snow from entering at the fastneners.
Membrane: One or more plies of StormGuard® Film Surfaced Leak Barrier, UnderRoof, 2 Polyester -
Surfaced Leak Barrier or UnderRoofr" HT High Temperature Leak Barrier membrane with a
minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave,
rolling the membrane to obtain maximum contact. Remove the release membrane as the
membrane is applied.
Surfacing: Approved for Metal roofing (StormGuard® Film Surfaced Leak Barrier, or UnderRoof" `' HT
High Temperature Leak Barrier), Slate, and Asphalt Shingle assemblies.
NOA No.: 14-0915.02
Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 6 of 8
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard®
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoof' HT High Temperature
Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-ArmorTm Premium Breathable Roof Deck Protection,
FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger Pawl Roof Deck Protection shall not be used as roof
tile underlayment.
3. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak
Barrier, StormGuard® Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoof'M 2
Polyester -Surfaced Leak Barrier, UnderRoof m HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck
Protection, Deck-ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic
Roofing Felt, and Tiger PawTM Roof Deck Protection shall be installed in strict compliance with applicable
Building Code.
4. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard®
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoof1m 2 Polyester -Surfaced
Leak Barrier, UnderRoof' HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-
ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger
Pawl Roof Deck Protection membranes shall be applied to a smooth, clean and dry surface with deck free of
irregularities.
5. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuardo
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoofTM 2 Polyester -Surfaced
Leak Barrier, UnderRoof' HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-
ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger
Paw' Roof Deck Protection membranes shall not be applied over an existing roof membrane.
6. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard®
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoofTM 2 Polyester -Surfaced
Leak Barrier, UnderRoof' HT High Temperature Leak Barrier, Shingle -Mateo Roof Deck Protection, Deck-
ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger
PawTM Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.
7. WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuardo
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester -Surfaced
Leak Barrier, UnderRoofrm HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-
ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger
PawTM Roof Deck Protection may be used with any approved roof covering Notice of Acceptance listing
WeatherWatch® Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard®
Film Surfaced Leak Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoofrM 2 Polyester -Surfaced
Leak Barrier, UnderRoofl HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-
ArmorTM Premium Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt, and Tiger
Pawl Roof Deck Protection as a component part of an assembly in the Notice of Acceptance. If WeatherWatch®
Mineral Surfaced Leak Barrier, WeatherWatch® XT Mat Surfaced Leak Barrier, StormGuard® Film Surfaced Leak
Barrier, LibertyTM SBS Self -Adhering Base/Ply Sheet, UnderRoof'M 2 Polyester -Surfaced Leak Barrier,
UnderRoof' HT High Temperature Leak Barrier, Shingle -Mate® Roof Deck Protection, Deck-ArmorTM Premium
Breathable Roof Deck Protection, FeltBuster® High -Traction Synthetic Roofing Felt and Tiger PawTM Roof Deck
Protection are not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade
County Product Control Department for approval provided that appropriate documentation is provided to detail
MIAMI•DADE COUNTY
NOA No.: 14-0915.02
Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 7 of 8
LIMITATIONS:
compatibility of the products, wind uplift resistance, and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application. Install when temperatures are 45° F and
rising.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. Wherever the adhesive back of UnderRoof" 2 Polyester -Surfaced Leak Barrier, or UnderRoof HT High
Temperature Leak Barrier comes in contact with polyester surfacing such as end laps, penetrations, and flashing
material, it must be set in a 1/8" troweling of an approved ASTM D 4586 Type I roofing cement.
13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
,2.,6
11411
END OF THIS ACCEPTANCE
DADE COUNTY NOA No.: 14-0915.02
MIAMti
Expiration Date: 02/21/18
Approval Date: 09/10/15
Page 8 of 8