Fig. 1: Installation Clearances
• Irrigation water should be directed away from the
heat pump pool heater -water spray can damage
the heat pump pool heater.
• Rain water run offs- the heat pump pool heater
can withstand normal rain. Install rain gutters to
prevent direct steams of rain water to the heat
pump pool heater.
• It is important to keep the area next to the heat
pump pool heater clear of shrubs, bushes and
chemicals containers. They could prevent air from
circulating fully through the heat pump pool heater,
and will affect the operation of the heat pump pool
heater or damage the heat pump pool heater.
• When installed in areas where freezing tempera-
tures can be encountered, drain the water circuit
to prevent possible freeze-up damage. See the
Freeze Protection Section.
• For high wind installation requirements, refer to
the diagram on pages 8 and 9.
Electrical Connections
Refer to the unit rating plate below the control panel for
precise power requirements for your unit, and for
ampacity and over -current protection requirements.
7
T4 7YAY BIM DIVISION
M ED FOR E
.`f ED BY
5 AIIQ RMI7 MUQrl BE laPT ON
EiSIPECTION WILL BE MADE.
All wiring must be in accordance with the National
Electrical Code, NFPA No. 70, latest edition, and all
applicable state and local codes. Wiring diagrams are
located on pages 22 through 26.
NOTE: Refer to the National Electrical Code, Article
680, for general requirements for swimming pools
and equipment, and to Article 440 for special consid-
erations necessary for circuits supplying hermetic
refrigeration motor/compressors.
• Locate the equipment disconnect means within 3
feet of the heater's electrical enclosure, or as
close to the heater as possible. Always satisfy
applicable codes and standards.
• In sizing power wiring, be especially aware of up -
sizing requirements necessary due to wiring
distances. Always satisfy applicable codes and
standards.
• Electrical installation should be done by a licensed
electrician only.
This unit is pre -wired to work with external control sys-
tems, heat -on -demand options and other external time
clock overrides. Refer to the external control system's
instructions,• and. page 27 of this manual, for installa-
tion information.
E
THIS DRAWING USED AS A GRAPHICAL REPRESENTATION ONLYAND IT
MAY NOTAPPEAR EXACTLY LIKE YOUR SPECIFIC UNIT.
PAD SPECIFICATION:
GREATER THAN OR EQUAL TO 4' THICK SOLID CONCRETE 3000 P. S. I.OR GREATER LOAD RATING
PAD LENGTH GREATER THAN OR EQUALTO UNIT LENGTH +6'
PAD WIDTH GREATER THAN OR EQUALTO UNIT WIDTH +6'
COVERED UNIT
HEIGHT BETWEEN
37-1/2'- 49.3/4'
NOT INCLUDING
ISOLATOR PADS
SEE HIGH WIND LOAD
RESTRAINT DETAIL 1
186 MPH, 3 SEC. GUST IN ACCORDANCE WITH:
ASCE 7.2010 CHAPTER 30 WIND LOADS - COMPONENTS AND CLADDING
FLORIDA BUILDING CODE 2D70 - SECTION 1609 WIND LOADS
FLORIDA BUILDING CODE 2010-SECTION 1620 HIGH VELOCITY HURRICANE ZONES- WIND LOADS
MINIMUM 18 GA. X 5' WIDE GALV. STEEL STRAP
(G90) OR EQUIVALENT (MIN. QTY. OF 4 STRAPS)
WITH (3) 1/2' LONG #12 SELF DRILLING SCREWS
EACH STRAP (MIN. 1000 HR. COATING)
'I000� (PADSTYP.VIBRATIOEA. CORNER
NIfY?ifi(i,ar �r':e6�'r'�str,y-rr.�� - '
�OmO�� (SEENPA SPECS.)I MN ETE PAD(2LENGTH TO ENETRA)114' CONCRETE TES
❑• Oo �OQ� RE32- MAX STRAINT HIGH WIND LOAD RESTRAINT DETA27' MIN IL
MINIMUM.
SPACING
II II QD N.
�1 SPACING
TYP.
rn
11
QT MODEL HURRICANE TIE DOWN SPECIFICATIONS
Tl49 pu usFnwsArnr»erxaEwaESErrt�nwuaar,urortmnvl�oriavern Exne�nuamlw cum.
MINIMUM 10 GA. X 3.75' WIDE STAINLESS STEEL
TIE DOWN (MIN. QTY. OF 4 TIE DOWNS) WITH (3)
THIS MOWING INTE OED FOR POOL HEATERS ONLYI
1IT LONG #12 SELF DRILLING SCREWS EACH
PAD SPECIFICATION,
STRAP (MIN. ROW HP, COATING)
GREATERTHAN OR EQUTHICK SOLID CONCRETE 2000 P. S. L OR GREATER LOAD RATING
PAD LENGTH GREATER THAN OR EQUALT042S
PAD LE
PAD WIDTH GREATER THAN OR EQUALTO 42.5'
SEEHMH WPIDLOAD
MSTRNNTDETARi
RESTRAINT
SETATEACH
CORNER
9
CAVE
HENW
37-IW
WITH
3'0.__
SPACRiGTYP,
MIM1 a1 sa /IM
��" -g2)114' CONCRETE SCREWS
CONCRETE PAD LENGTH TO PENETRATE
(SEE PAD SPECS) 2-W MINIMUM.
HIGH WIND LOAD RESTRAINT DETAIL 1