HomeMy WebLinkAboutINSTALLATION CLEARANCESI DEC 12 2017 PERMITTING St. Lucie County, FL GAS -. HEATER MIN AIR -T FLOW -- IN F 0- MIN AIR FLOW OUT 1T_ MIN I I ST. L Fig. 1: Installation Clearances • Irrigation water should be directed away from the heat pump pool heater -water spray can damage the heat pump pool heater. • Rain water run offs- the heat pump pool heater can withstand normal rain. Install rain gutters to prevent direct steams of rain water to the heat pump pool heater. • It is important to keep the area next to the heat pump pool heater clear of shrubs, bushes and chemicals containers. They could prevent air from circulating fully through the heat pump pool heater, and will affect the operation of the heat pump pool heater or damage the heat pump pool heater. • When installed in areas where freezing tempera- tures can be encountered, drain the water circuit to prevent possible freeze-up damage. See the Freeze Protection Section. • For high wind installation requirements, refer to the diagram on pages 8 and 9. Electrical Connections Refer to the unit rating plate below the control panel for precise power requirements for your unit, and for ampacity and over -current protection requirements. 7 T4 7YAY BIM DIVISION M ED FOR E .`f ED BY 5 AIIQ RMI7 MUQrl BE laPT ON EiSIPECTION WILL BE MADE. All wiring must be in accordance with the National Electrical Code, NFPA No. 70, latest edition, and all applicable state and local codes. Wiring diagrams are located on pages 22 through 26. NOTE: Refer to the National Electrical Code, Article 680, for general requirements for swimming pools and equipment, and to Article 440 for special consid- erations necessary for circuits supplying hermetic refrigeration motor/compressors. • Locate the equipment disconnect means within 3 feet of the heater's electrical enclosure, or as close to the heater as possible. Always satisfy applicable codes and standards. • In sizing power wiring, be especially aware of up - sizing requirements necessary due to wiring distances. Always satisfy applicable codes and standards. • Electrical installation should be done by a licensed electrician only. This unit is pre -wired to work with external control sys- tems, heat -on -demand options and other external time clock overrides. Refer to the external control system's instructions,• and. page 27 of this manual, for installa- tion information. E THIS DRAWING USED AS A GRAPHICAL REPRESENTATION ONLYAND IT MAY NOTAPPEAR EXACTLY LIKE YOUR SPECIFIC UNIT. PAD SPECIFICATION: GREATER THAN OR EQUAL TO 4' THICK SOLID CONCRETE 3000 P. S. I.OR GREATER LOAD RATING PAD LENGTH GREATER THAN OR EQUALTO UNIT LENGTH +6' PAD WIDTH GREATER THAN OR EQUALTO UNIT WIDTH +6' COVERED UNIT HEIGHT BETWEEN 37-1/2'- 49.3/4' NOT INCLUDING ISOLATOR PADS SEE HIGH WIND LOAD RESTRAINT DETAIL 1 186 MPH, 3 SEC. GUST IN ACCORDANCE WITH: ASCE 7.2010 CHAPTER 30 WIND LOADS - COMPONENTS AND CLADDING FLORIDA BUILDING CODE 2D70 - SECTION 1609 WIND LOADS FLORIDA BUILDING CODE 2010-SECTION 1620 HIGH VELOCITY HURRICANE ZONES- WIND LOADS MINIMUM 18 GA. X 5' WIDE GALV. STEEL STRAP (G90) OR EQUIVALENT (MIN. QTY. OF 4 STRAPS) WITH (3) 1/2' LONG #12 SELF DRILLING SCREWS EACH STRAP (MIN. 1000 HR. COATING) 'I000� (PADSTYP.VIBRATIOEA. CORNER NIfY?ifi(i,ar �r':e6�'r'�str,y-rr.�� - ' �OmO�� (SEENPA SPECS.)I MN ETE PAD(2LENGTH TO ENETRA)114' CONCRETE TES ❑• Oo �OQ� RE32- MAX STRAINT HIGH WIND LOAD RESTRAINT DETA27' MIN IL MINIMUM. SPACING II II QD N. �1 SPACING TYP. rn 11 QT MODEL HURRICANE TIE DOWN SPECIFICATIONS Tl49 pu usFnwsArnr»erxaEwaESErrt�nwuaar,urortmnvl�oriavern Exne�nuamlw cum. MINIMUM 10 GA. X 3.75' WIDE STAINLESS STEEL TIE DOWN (MIN. QTY. OF 4 TIE DOWNS) WITH (3) THIS MOWING INTE OED FOR POOL HEATERS ONLYI 1IT LONG #12 SELF DRILLING SCREWS EACH PAD SPECIFICATION, STRAP (MIN. ROW HP, COATING) GREATERTHAN OR EQUTHICK SOLID CONCRETE 2000 P. S. L OR GREATER LOAD RATING PAD LENGTH GREATER THAN OR EQUALT042S PAD LE PAD WIDTH GREATER THAN OR EQUALTO 42.5' SEEHMH WPIDLOAD MSTRNNTDETARi RESTRAINT SETATEACH CORNER 9 CAVE HENW 37-IW WITH 3'0.__ SPACRiGTYP, MIM1 a1 sa /IM ��" -g2)114' CONCRETE SCREWS CONCRETE PAD LENGTH TO PENETRATE (SEE PAD SPECS) 2-W MINIMUM. HIGH WIND LOAD RESTRAINT DETAIL 1