CBUCK Engineering
Specialty Structural Engtneprtnq
Evaluation Report
"5V Crimp"
CBUCK, Inc. Certificate of Authorization #8064
Metal Roof Assembly 1-7 ( Z-o 24V
ST. LUCIE COUNTY BLTLV-%LYG 32 10`'
RvEVIEWEB FOR CO
Manufacturer: nv,, :vEB By
Extreme Metal Fabricator.
2160 SW Poma DrlveOR � T//��� N�cnP��� Jai
r/y ��p�Ta JOB
Palm City, FL 34990
for
Florida Product Approval
# FL 20378.6
Florida Building Code Sth Edition (2014)
Method: 1- D
Category: Roofing
Sub - Category: Metal Roofing
Product: 5V Crimp Roof PanCONCEALED FASTLENERSORATTACK"ai,...
THESE PLANS AND ALL PROPOSED WORK Material: Steel
ARE THE RESPONSIL.'UTY. OF THE
ARE SUBJECT TO ANY CORRECTIONS
f3Y FIELD INSPECTORS THAT Panel Thickness: 26 gauge
CONTRACTOR OF RECORD
REQUIRED
MAY BE NECESSARY IN ORDER TO Panel Width: 24"
,(%IDLY WITH ALL APPLICABLE CODES. Support: Wood Deck
Fastener Placement: Rib Peaks or Rib Valleys
Prepared by:
Digitally signed by James L. Buckner, P.E.
James L. Buckner, P.E., S.E.C.B.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
Florida Professional Engineer # 31242
61G15-2;\\,\+11i1,�,,�,/
Florida Evaluation ANE ID: 1916
��•��r�s ! : BUc'�ti�,
Project Manager: Diana Galloway
;
Report No. 16-124- 5V-S6W-ER
_ No 31242
*
(Replaces 11-219-5V-56W-ER)
-
� `
Date: 4 / 14 / 16
=U'�
T' STATE OFkq
'�is�ONA1
Contents:
Evaluation Report Pages 1- 8 File Copy
;
CBUCK, Inc. • Palm Beach County, Florida
2016.04.19 11:32:32-04'00'
Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net
Mailing Address: 2637 E. Atlantic Blvd, #34069, Pompano, FL 33062
—� FL #: FL 20378.6
Date: 4 / 14 / 16
CBUCK Engineering Pagert No.. 26of8 5v-56w-ER
Specialty Structural Engineering
Manufacturer: Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
Product Name: SV Crimp
Product Category: Roofing
Product Sub -Category Metal Roofing
CBUCK, Inc. Certificate of Authorization #8064
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System "5V Crimp"
Description: 26-gauge Steel exposed fastener roof panel, 24" wide, mechanically attached to
Wood Deck with and screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of
this evaluation.)
Description:
• 15/32 (min.) or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure: Refer to Table A
(Refer to "Table A" attachment details herein)
FL #: FL 20378.6
Date: 4 / 14 / 16
CBUCK Engineering Report No.: 36of 8-5V-56W-ER
Specilalty Structural Engineeri'nq CBUCK, Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• U L580-06 — Test for Uplift Resistance of Roof Assemblies
• U L 1897-04 — Uplift test for roof covering systems
• TAS 125-03 —Standard Requirements for Metal Roofing Systems
Standards Equivalency:
The UL 580-94 & UL 1897-98 standard version used to test the evaluated product
assembly is equivalent with the prescribed standards in UL 580-06 & UL 1897-04
adopted by the Florida Building Code 5th Edition (2014).
Code Compliance:
The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida Building
Code.
Evaluation Report
This product evaluation is limited to compliance with the structural requirements
Scope:
of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 61G20-3.001.
Limitations and
This evaluation report for "Optional Statewide Approval' contains technical
Conditions of Use:
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
Option for application outside "Limitations and Conditions of Use"
• Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation, per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific
or permit design.
• Deck shall be in compliance with applicable building code.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA
1824).
CBUCK Enginsprinq
FL #: FL 20378.6
Date: 4 / 14 / 16
Report No.: 16-124-5V-S6W-ER
Page 4 of 8
Specialty Structural Engineerinq CBUCK, Inc. Certificate of Authorization ##8064
Components/Materials Roof Panel: "5V Crimp"
(by Manufacturer): Material: Steel
Thickness: 26 gauge (min.)
Panel Width: 24" (max.) Coverage
Rib Height: 3/8"
Alloy Type: 40 ksi min.
Corrosion Resistance: In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Fastener:
Type: Hex -Head Wood Screw with WSW
Size : #9 - 15 x 1"
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per FBC 1507.4.4 and ANSI/ASME B18.6.1
Components/Materials Underlayment:
(by Others): Material and application shall be in compliance with FBC Chapter 15 based on the
type of roof covering, applicable codes and in accordance with manufacturer's
recommendations.
Insulation (Optional):
Type:
Thickness:
Properties:
Density:
Or Compressive Strength
Rigid Insulation Board
3" (max.)
2.25 pcf (Ibs/ft3) min.
20 psi min.
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508. When insulation is
incorporated, fastener length shall conform to penetrate thru bottom of
support a minimum of 3/16".
FL #: FL 20378.6
Date: 4 / 14 / 16
Page Report No.: 5 of g 5v-56w-ER
CBUCK EnginPPring
Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Installation: Installation Method:
(Refer to Table A and the drawings at the end of this report.)
■ Fastener spacing: Refer to Table "A" Below
(attached to the tops of the V's or in the valleys per Table A for a total of 3
screws across the width of the panel.)
■ Row Spacing: Refer to Table "A" Below
(along the row, across the panel profile)
■ Rib Interlock: Lapped
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE "A"
5V Crimp" (26 ga. Steel), 24" Wide Roof Panel Attached to Wood Deck
ALLOWABLE LOADS
#
Deck
Fastener
Row
Fastener
Fastener
Design
Thickness
Spacing
Spacing
Placement
Pressure
(min.)
(max.)
(max.)
I(ASD)*
1
15/32" min.
12"
12"
#g
Corrugation Peaks
(Refer to Dwgs Pg 7)
_ 85 PSF
2
15/32" min.
12"
12"
#9
Corrugation Valleys
_ 114.25 PSF
(Refer to Dwgs Pg 8)
Allowable design pressures) for allowable stress design (ASD) with a margin of safety of 2 to 1.
Install the "5V Crimp" roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 5th Edition
(2014). The installation method described herein is in accordance with the scope
of this evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. TAS 125-03 Uplift Test
By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527)
Method 1: Report 0223-0307-01; Test Date: 03 / 05 / 01- 03 / 08 / 01
Method 2: Report 0223-0517-06; Test Date: 05 / 19 / 06 - 05 / 22 / 06
2. Quality Assurance
By Keystone Certifications, Inc. (QUA ID: 1824)
Extreme Metal Fabricators, Inc. Licensee #974
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
5. Additional Reference Data
By USBC, #6:15-bk-03351-KSJ Doc 85, Dated 2/29/2016
�l
CBUCK Engineerinq
FL #: FL 20378.6
Date: 4 / 14 / 16
Report No.: 16-124-5V-S6W-ER
Page 6 of 8
Specialty Structural Enginewinca CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
5V Crimp" (26 ga. Steel), 24" Wide Roof Panel Attached to Wood Deck
T
Profile Drawings
24" Maximum Net Coverage
"5V Crimp" Panel
Typical Panel Profile View
TABLE "A"
5V Crimp" (26 ga. Steel), 24" Wide Roof Panel Attached to Wood Deck
ALLOWABLE LOADS
#
Deck
Fastener
Row
Fastener
Fastener
Design
Thickness
Spacing
Spacing
Placement
Pressure
(min.)
(max.)
(max.)
(ASD)*
1
15/32" min.
12"
12"
#9
Corrugation Peaks
_ 85 PSF
(Refer to Dwgs Pg 7)
2
15/32" min.
12"
12"
#g
Corrugation Valleys
_ 114.25 PSF
(Refer to Dwgs Pg 8)
*Allowable design
pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.
�FL #: FL 20378.6
Date: 4 / 14 / 16
CBUCK Engineerinq Page Report No.: �o6f 8-5V-56W-ER
Specialty Structural Engineprinq CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
5V Crimp" (26 ga. Steel), 24" Wide Roof Panel Attached to Wood Deck
12" o.c. Typical
Fastener Spacing
Across Panel Width
#9-15 Hex -Head Screw
with Mather Seal washer
3/16" min. penetration thru deck
Spaced 12" o.c. across the Panel
Typical Assembly Profile View (METHOD 1)
Fasteners -
#9 -15 Hex -Head Screws With W-Crimp" Roof Panel
EPDM Bonded Steel Washers
Optional:
Deck
greater Plywood, or Rigid Insulation
-15/32" or
9 yw Thickness 3" Maximum
- Wood plank
Typical Assembly Isometric View (METHOD 1)
H
FL #: FL 20378.6
Date: 4 / 14 / 16
Page
Report NO.: 8 Of 8-5V-S6W-ER
N I
CBUCK Er1Q1neering Pa
Specialty Structural r=nc21 1@@rinc2 CBUCK, Inc. Certificate of Authorization #8064
Installation Method
Extreme Metal Fabricators, LLC.
5V Crimp" (26 ga. Steel), 24" Wide Roof Panel Attached to Wood Deck
12" o.c. Typical
Fastener Spacing
Across Panel Width
#9-15 Hex -Head Screw
with Weather Seal washer
3/16" min. penetration thru deck
Spaced 12" o.c. across the Panel
Typical Assembly Profile View (METHOD 2)
Fasteners -
#9 -15 Hex -Head Screws With 5V-Crimp" Roof Panel
EPDM Bonded Steel Washers
AL
Fi a
a
Deck:
-15/32" or greater Plywood, or
- Wood plank
YII�YGlaSmlb
Optional:
Rigid Insulation
Thickness 3" Maximum
Typical Assembly Isometric View (METHOD 2)