FLORIDA BUILDING CODE 2010, SWIMMING POOLS AND ALL APPLICABLE COUNTY
AND CITY CODES SHALL GOVERN.
I . FBC 2010 424.2.G. I CONFORMANCE STANDARD.- DESIGN, CONSTRUCTION
AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF
AN5UN5PI 3 AN51/N5PI 4 AN51/N5P1 5 AN51/N51`I G AND AN51/AP5P 7.
2. FBC 424.2.G.3 WATER VELOCITY.- POOL PIPING SHALL BE DESIGNED 50 THE
WATER VELOCITY WILL NOT EXCEED '10 FEET PER SECOND (3048 MM/5) -FOR
PRE55URE PIPING AND 8 FEET PER SECOND (2438 MM/5) FOR SUCTION
PIPING, EXCEPT THAT THE WATER VELOCITY SHALL NOT EXCEED 8 FEET PER
SECOND (2438 MM/5) IN COPPERTUBING. MAIN SUCTION OUTLET VELOCITY
MUST COMPLY WITH AN51/A55P 7.
EXCEPTION: JET INLET FITTINGS SHALL NOT BE DEEMED SUBJECT TO THI5
REQUIREMENT.
3. FBC 424.2.G.5 PIPING INSTALLATION.- ALL PIPING MATERIALS SHALL BE
INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS INSTALLATION
STANDARDS.
EXCEPTION: PRIMER AND GLUE ON EXPOSED ABOVEGROUND PIPING NOT
REQUIRED TO BE COLORED.
4. FBC 424.2.G.G ENTRAPMENT PROTECTION.- FOR SUCTION OUTLETS SHALL BE
INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF AN51/AP5P 7.
5. FBC 424.2.8 VALVES: ALL VALVES ON POOL PIPING SHALL CONFORM WITH
SECTIONS 424.2.8. 1 THROUGH 424.2.8.4.
G. FBC 424.2.9 WATER SUPPLY: UNLESS AN APPROVED TYPE OF FILLING
SYSTEM 15 INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGMENT OF THE
ADMINISTRATIVE AUTHORITHY MAY BE USED TO FILL THE POOL, SHALL BE
EQUIPPED WITH BACKFLOW PROTECTION. NO OVER THE RIM FILL SPOUT
SHALL BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR
PROPERLY GUARDED.
7. FBC 424.2.12. 1 PRE55URE TEST.- ALL POOL PIPING SHALL BE TESTED AND
PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY,
UNDER A STATIC WATER OR AIR PRESSURE TEST OF NOT LE55 THAN 35
POUNDS PER SQUARE INCH (P51) (241 KPA) FOR 15 MINUTES.
EXCEMPTION: CIRCULATING PUMPS NEED NOT BE TESTED AS REQUIRED IN
THI5 SECTION.
8. FBC 424.2.14.4 CONNECTIONS.- ALL WATER HEATING EQUIPMENT SHALL BE
INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT TO THE
HEATER.
9. FBC 424.2.15 GAS PIPING.- GAS PIPING SHALL COMPLY WITH THE FLORIDA
BUILDING CODE, FUEL GAS. SEPARATE PLANS AND PERMIT REQUIRED
10. FBC 424.2.1 G ELECTRICAL.- ELECTRICAL WIRING AND EQUIPMENT SHALL
COMPLY WITH CHAPTER 27 OF THE FLORIDA BUILDING CODE; NFPA 70,
NATIONAL ELECTRICAL CODE, EXCEPT ARTICLE 80; AND NFPA 70. NATIONAL
ELECTRIC CODE, ARTICLE G80.
1 1 . FBC 424.2. 17 RESIDENTIAL SWIMMING BARRIER REQUIREMENT.- RESIDENTIAL
SWIMMING POOLS SHALL COMPLY WITH SECTIONS FBC 424.2.17.1
THROUGH 424.2.17.3 EXCEPTION: A SWIMMING POOL WITH AN APPROVED
SAFETY POOL COVER COMPLYING WITH ASTM F 134G:
12. PIPING- PIPING SHALL BE 5CH. 40 BEARING N.S.F. APPROVAL PER PBC 201 O
R4101
13. STEEL- REINFORCING STEEL WILL CONFORM TO A.S.T.M. G 15 GRADE CO
14. SOILS- THE DE51GN BEARING CAPACITY FOR THI5 POOL SHALL BE A MINIMUM
OF 2,000 P.S.F..
15. CONCRETE- POOL WALLS E FLOOR WILL BE PNEUMATICALLY APPLIED
CONCRETE W. A MIN. 28 DAY COMP. STRENGTH OF 4,000 P.5.1.
I G. TEMPERATURE- POOL OR 5PA TEMPERATURE SHALL NOT EXCEED 102° F.
17. POWER LINES- OVERHEAD ELECTRICAL POWER LINES SHALL BE LOCATED A
MIN. OF 10 FEET FROM POOL WATER'S EDGE AND UNDERGROUND
ELECTRICAL POWER LINES SHALL BE LOCATED A MIN. OF 5 FEET FROM THE
POOL WATER'5 EDGE OR IN ACCORDANCE WITH NFPA 70, NATIONAL
ELECTRICAL CODE, ARTICLE C80.
18. NATIONAL ELECTRIC CODE- ELECTRICAL AND ALL BONDING SHALL BE IN
COMPLIANCE WITH ARTICLE G80
19. CONTRACTOR MUST APPLY PROPER MEANS AND METHODS OF
CONSTRUCTION TO PROTECT ALL EXISTING STRUCTURES. UNLESS OTHERWISE
NOTED, THE DE51GN ENGINEER HAS NOT BEEN ENGAGED TO CONDUCT, NOR
HAS HE CONDUCTED ANY FIELD TESTS, EVALUATIONS OR 51TE VISITS. WITH
RESPECT TO CONDITIONS AS THEY MAY EXIST AT THE SITE. THEREFORE, THE
DE51GN ENGINEER 15 NOT RESPONSIBLE OF, AND ASSUMES NOT LIABILITY
FOR, EXISTING STRUCTURES, INCLUDING THE CONDITIONS OF EXISTING
SEAWALLS AND APPLICABILITY FOR EXCAVATION IN ITS PROXIMITY. SHOULD
ANY EXISTING STRUCTURE BE ENCOUNTERED, STOP CONSTRUCTION AND
IMMEDIATELY NOTIFY THE DESIGN ENGINEER AND BUILDING OFFICIAL PRIOR
TO PROCEEDING. THIS INCLUDES BUT IS NOT LIMITED TO ENCOUNTERING THE
FOLLOWING:
'WALL ANCHOR RODS
'FOUNDATIONS OF SEAWALLS, BUILDINGS, POWER POLES
'BURIED VAULTS AND DRAINAGE STRUCTURES, AND OTHER
BELOW GROUND STRUCTURES
20. SHOULD THE INTEGRITY OF A SEAWALL BE FOUND TO BE INADEQUATE OR
BECOME COMPROMISED, THE CONTRACTOR SHALL IMMEDIATELY ENGAGE
THE HOME OWNER IN CORRECTIVE MEASURES AS DIRECTED BY A LICENSED
QUALIFIED SEAWALL CONTRACTING SPECIALIST. THESE PROCEDURES SHALL
BE IN FULL COMPLIANCE WITH RECOMMENDATIONS MADE BY THE DE51ON
ENGINEER AND LOCAL BUILDING OFFICIAL. THE CONTRACTOR AND OR
HOMEOWNER SHALL SECURE THE STRUCTURE WITHIN 48 HOURS, BASED ON
SAID RECOMMENDATIONS; TO INCLUDE, BUT NOT LIMITED TO, THE
EMERGENCY INSTALLATION OF HELICAL PILES OR BATTER PILES.
21 . NOTE I - POOL LOCATION -THE DESIGNER AND THE ENGINEER A55UME NO
RESPONSIBILITY TO THE LOCATION OF THE POOL, PATIO AND EQUIPMENT
ENCROACHING INTO EASEMENTS, OR SETBACKS.
22. NOTE 2- PLAN PROPERTY -THE PLANS REMAIN THE PROPERTY OF THE
SPECIFIED DESIGNER, ENGINEER AND CONTRACTOR AND CANNOT BE
TRANSFERRED WITHOUT WRITTEN PERMISSION FROM THEM.
6�IGF
SLOP-0,
GBARE OLID COPPER
5E
,
o a
WIRE,ALLAROU D POOL PERIMETER
EDGE
BU�� �RyINE
AND 4"WITHIN-GBBELOW GRADE.
JUMPER SHALL BE INSTALLED IN AT
LEAST 4 LOCATIONS EQUALLY
SPACED AROUND THE PERIMETER
AP
OF THE POOL OR SPA W/APPROVED
TERMINATION DEVICE
�P�
I
\1ER�O��NO
SNO
2) #3 CONT.
QEEP
AWG BARE SOLID COPPER
BONDING JUMPER
Tt11�K
#3 @ 1 2" O.C.E.W.
MIN. 3° COVER (CENTER)
Rp,��ES
STEELTEX FORM, MASONITE
OR MIN. 1/8" PLYWOOD
#3 @ 12" O.C.E.W.
BOTTOM CENTERED FOR
DEPTHS UP TO G' DEEP.
G' MINIMUM THICKNESS
TYPICAL WALL SECTION
NOTE: SOLID COPPER WIRE 15 REQUIRED WHEN BURIED IN THE
SANDSOIL UNDER A BRICK OR PAVER DECK TYPE SURFACE.
THE FOLLOWING PARTS MUST BE BONDED TO THE EQUIPOTMAL BONDING GRID:
A) METALLIC PARTS, B) UNDERWATER UGHTING, C) METAL FITT NG5, D) ELECTRICAL
EQUIPMENT (PUMPS, HEATERS, ETC.), E) REBAR IN POOL STRUCTURE, F) METAL
CABLES, G) METAL PIPING, H) FIXED METAL PARTS, 1) METALLIC SURFACES OF
ELECTRICAL EQUIPMENT.
t. j_ r--' WATER LINE
1 _l
2" COND. } z
I ° COND. = 12V VAC LIGHTING
NOTE: NO NICHE OR
THE USE OF WHITE BONDING REQUIRED
PVC IS PROHIBITED
GLO-BRITE LIGHT DETAIL
+ar., ::v�•r !•.:,:f .• 4" THICK REINFORCED
'• '` CONCRETE SLAB PER
F.B.C. 1820.3
FILTERBASE0
HEATER
(IF INDICATED)
PUMP
MOTOR(5)
WATERLINE TILE
NOTE:
• ANCHOR BOLTS THROUGH BASE WITH 1-314" X 3/ 1 G° TAP CON SCREW OR
3/8" ANCHOR BOLT FOR POOL PUMP 4 FILTER
• HEAT PUMP - (4) ANGLE BRACKETS, EA 2-1/2" IN LENGTH. EACH BRACKET
SHALL BE ATTACHED TO THE CONC. WITH (1) 1-3/4" X ,-j" TAP CON SCREW
(OR JANCHOR BOLT) AND ATTACHED TO THE EQUIP WITH (1)' SELF
TAPPING SHEET METAL SCREW.
• POOL HEATER SHALL BE PROVIDED WITH A THERMOSTATIC OR HIGH
PRESSURE CONTROL SWITCH OR OTHER ACCEPTABLE OVER HEATING
PROTECTION DEVICE 50 POOL WATER DOES NOT EXCEED 104 F
• COMPLIANT WITH FLORIDA BUILDING CODE 2010
POOL EQUIPMENT ANCHORING
I
IMPORTANT NOTE: NO DIVING BOARD AND NO DIVING 15 ALLOWED ON ANY POOL LESS
THAN V-0" DEEP AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL
15 NOT DESIGNED FOR DIVING.
31
LINE
1:7 SLOPE
MAXIMUM
MAIN DRAIN PER
R4101.21.3
LONGITUDINAL POOL SECTION
WA
NE
STANDARD PACIFIC HOMES
BRICK "RIVERBEND" - LOT 10"
SCHWYN RESIDENCE
3034 NW RADCLIFF WAY,
DN—T. ST. LUCIE COUNTY, FL
#3 @ 12" O.C.E.W
° (SEE TYPICAL Proiect No: 17-0127
--- • .i. WALL SECTION) Date:12-05-2017
5WIMOUT / BENCH DETAIL
VARIE5
JW I '
C3
WW
ao_
H
5UN5HELF / STEPS DETAIL
HOSE BIBB
NOTE: AUTO FILL LOCATION TO
BE DETERMINED IN FIELD
TEE
I BY PLUMBER I SHUT OFF VALVE
BY PLUMBER
I BY FOUNTAIN BLUE 1 " STUB OUT
POOLS 111
I -
TO
SPA
AUTO FILL
AUTO WATERFILL DETAIL
The concepts, drawings; designs, and logos
represented in these sheets are the property
ofthe respective owners. Any reproduction
of this information is with the express
authorization ofthe owners. This
information can only be used in work the
owners have authorized and any
reproduction is strictlyprohibited without
the express authorization ofthe respective
owners. Written dimensions on these
drawings shall have precedence over scale
dimensions. An construction shall be in
accordance with the accepted Florida
Building, State, and Local Codes.
HOUSE I I MW
ENGINEERING INC
O��Vv W
Q�O e� e•e•��d�n%�
Ro 'ry • m
• ;q®
• �LLI®
•
I g-f F: l OF
�O• O n '��
0
MARK E. WEBER, P.E.
LIGSNSE #53895
68•iVo th State Road 7,
Coconut Creek, FL 33073
Phone:954-617-8143
PAGE: 2 of 4