HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENT3 A
b r•1
aCIS Home ;Log In i User Registration , Not Topla ( Stibrnit Surcharge Stats.& Facts ; Publications, ( FpC Staff ; BQS Site Map Unks Search
R0f(t�d ,,
t Productt pproval
U. � USER:`Publii User
r
ri.Pr7u4a SS,Pwxie Menu > P•c•Sw- or ksti�lisptlnn Se,�M > At WL� -, Hon'list a Application Detail
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
/ 71(Z-623
ST. LUCIE COUNTY 1BLTLDLgG D:A✓..TSION
Product Manufacturer
Tri-Built Materials Group, LLCREVIER ED FOR COMPL NCE
Address/phone/Emalf
PO Box 70.
REVIEIVVED Y w
Rutherford, NJ; 07070
DATE
davld s!i@tri s
david.ruiz@tribulltmg.coni
T
PLANS AND PERMIT MUST BE PT ON JOB
OR NO INSPECTION WILL BE A - LADE.
Authorized Signature
David Ruiz
david.ruiz@tribu iltmg.com
Technical Representative
David Ruiz
Address/Phone/Email
250 Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david, ruizC6tribuiltmaterialsgroup.colts
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Roofing
Underlayments
THESE PLANS AND ALL PROPOSED WORK
CompiARSSUBJECT TO ANY CORRECTIONS Evaluation Report from a Florida Re istergd Arch' ct q ,�j� n
REQUIRED BY FIELD INSPECTORS THAT Florida Professional Engineer • CA reA(�D h�s I �I�tH� 59ATTACHMENTS
MAY BE NECESSARY IN ORDER TO U Evaluation Report- Hardcopy Receive E THE RES?ONSIBILI IY OF THE
COMPLY WITH ALL APPLICABLE CODES,
Florida Engineer'or Architect Name who developed Robert Nieminen CONTRACTOR 0� RECORD
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance contract Expiration Date 67/18/2020
Validated By John W. Knezevich, PE
LIZ Validation Checklist - Hardcopy Received
Certificate. of Independence
EL-0048 RS ECI 7Q1.7 1 CQI_Nieminen.odf
Referenced Standard and Year (of Standard),
atandard
Year
ASTM D197.0
2009
ASTM G155
2005
FM 4474
2004
FRSA/TRI_April 2012 (04-12)
2612
TAS 103
1995
UL1897
2004
Equivalence of Product Standards
Certified By
He Copy
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved.
Date Revised
Summary of Products
Method 1 Option D
06/12/2017
06/13/2017
06/19/2017
08/08/20i7
09/25/2017
FL #
Model, Number or -Name
Description
16048.1
TRI-BUILT Roof underiayments
:Self -adhering,. modified bitumen roof.underlayments
Limits of Use
Installation Instrcctions
Approved for use in HVHZe No
FL1 ,04�S 11' 201� t1 . FIN F3._LR
Approved for use outside HVHZ: Yes
land i1 DF_RLAYh
Impact Resistant: N/A
Verified By: Robert Nieminen PE=59166
Design Pressure:.+N/A/-1'5()
Created by Independent Third Party: Yes
Other: 1.) The -design pressure noted herein; pertains to use
Evaluation Reports
of foam-on,tlle systems overtop the Self-adherirlg
FL16048 R5 AE.20U 06 F-�LE �R TRT_.
underiaymentfor one particular application.'See ER. Section'
BUILT UNDERLAYMENTS: FL16048-Rs ndf
5.6.4 for details, 2.) Refer to tR Section S: for other Limits of
- Created by Independent.Third Party: Yes.
use:
Aack Next
Contact 11d ;; 2601-Blab 5191e Road Tallahassee FL 32399 Phonat 850-487-1824.
The State of Florida is an AA/EEO employer; Co[wrioht 2007-701,1 StatA or Fiorlda 7; Pribacy'Statement :; Accessibility Statement.:; S€f4.Od'$tatemant
Under Florida law, email addresses are.public'records. if you do'notwant your e•maiC address released an response tom public -records request,.. dot not Send electronic
mail to this entity. instead, contact the office by nlioile or by traditional mall. if you have any questions, please contact 830.487, 1395. •Pursudm[ td Section 455.275,
(1), Florida Statutes; effective daoLer 3; 2017, licensees licensed under Chapter 455,, P.S. must provlde the Department with an ernoil address, if they hp6g one. The
emalls provided may used for official communicatlon with thelicensee. However email addresses arc public record. If,you.do not wish to supply a personal address,
Planse'Proyide,the Depantneniwith an ...[Iaddress which Can be made avahlable to: the public; to determine.if you area Licensee under Chapter A55, F.S:, please
click here..
Produ�ct �Approval (A��cceepts:
ft1�2Yt1 W L M
il-11,
EXTERIOR RESEARCH & DESIGN, I.I.C.
t Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13'
ERD OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A'42960.10.12=115
PO Box 70 FL16048-R5
Rutherford, NJ 07070 Date of Issuance:1012512012
(800) 516-1485 Revision 5 06/12/2017
SCOPE:'
This Evaluation Report is issued under Rule 61G203 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the: 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality. Assurance Agency noted
herein.
CONTINUED_ COMPLIANCE: This Evaluation' Report is valid until such time.as the: named product(s) •changes, the: referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the ..named client constitutes agreement, to notify Robert Nieminen, P.E. if 'the product
changes or the referenced Quality Assurance,documentation changes. Trinityl ERD requires'a complete review of this
Evaluation Report relative to updated Code,requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words, "Trinity.1 ERD' Evaluated" may be displayed in
advertising literature, If any portion of the Evaluation Report is displayed, then it shall be done in its entirety:
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6
Prepared by:
^
l�itfilF)t�,.f
Robert I.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE2983
me facsimile sea] appearing was aukhorked by RobeaNieminen,
KE 06/12J2017. This does riot geme'asadeleownically signed
466nient'Signed, sealed haidwp.es hay.: been transmitted to the
Pmduct App—atAdmf.istrappr and tothe named dl.at
CER'nF1c4T10N OF INDEPENDENCE: '
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire; a financial interest in ally company manufacturing or
distributing products it evaluates,
2. Trinity ERD is not owned, operated or controlled by any company, manufacturing or distrib uting. products it.evaluates.
3. Robert Nieminen, P.E. does pot have nor will acquire; a financial interest.in any company manufacturing or distributing'products for
.which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have,..nor will acquire, a financial interest in any other entity ir.4olved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD no`r Robert Nieminen, RE. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, islwas used for permitting or design guidance unless retained
specifically for'that purpose.
r
ROOFING COMPONENT EVALUATION:
1. SCOPE:
t
R ,�t ! ERD
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments; as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections. of the Florida Building Code through testing in accordance
with the following;5tandards. Compliance is subject to the installation Requirements and Limitations./Conditions .of
Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
.2004
1504.3.1
Wind Uplift
UL 1897 a2004
1S07.2.4, 1507.2.8,1507.2.9.2,
Physical Properties
ASTM D1970
2609
1507A.5.1, 1507.5.3, 1507.7.3
1504.6
Accelerated Weathering
ASTM G155
2005
1507.3.3
Installation Practice
FRSA/TRI April 2012 (04-12)
2012
1523.6.5.2:1
Physical Properties
TAS 103
1995
3. REFERENCES:
Enti Examination Reference
Date
ERD (TST6049) Physical Properties S40540.02.13-1
02/19/2013
ERD (TST6049) Physical Properties S40540.11.13
11/19/2013
ERD (TST6049) Physical Properties S40540.03.14
03/26/2014
ERD (T5T6049) Physical Properties S44870.04.14=2
04/02/2014
ERD (TST6049) Physical Properties 544870.04.14-3
04/02/2014
ERD.(TST.6049j Physical Properties S44870.04.14=1
04/10/2014
ERD.(TST6049) Physical Properties S44870.04.14-4
04/10/2014
ERD (TST6049) Physical Properties S43530.02.14-1-111
05/14/2014
ERR(TST6049) Physical Properties 543530.05.14
05/28/2014
ERD (TST6049) Physical Properties S40540A0.14
10/31/2014
ERD. (TST6049) Physical Properties SC7645.02.15
02/13/2015
ERD (TST6049) Accelerated Weathering. SC8520.04:15
05/27/2015
ERD (TST6049) Wind Resistance SC14045.05.17-111
06/07/2017
UL, LLC, (QUA9625) Quality Control Multiple -Listing R16814
09/04/2015
UL, LLC. (QUA9625) QualityrControl Service Confirmation
Exp.10/16/2017
4. PRODUCT DESCRIPTtON:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a.self-adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof' underlayment,. with a 36-inch sheet width.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering; non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.3 Tri=Built Smooth HT S/A Underlayment is .a self -adhering, glass -mat reinforced, .film -surfaced, SBS
modified bitumen roof underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E.
are, in any Way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained.specifically for -that purpose.
5.2 This Evaluation Report is'not for use in the HVHZ.
Exterior Research and Design, UC. Evaluation Report A42960.10.12-R5
Certificate ofAuthorizotion #9503 FBC NOWHV.HZ FVALUAMN FL1604B-RS
Tri-Built Materials Group, I.I.C. Revision5: 06/12/2017
Page 2 of 6
z<, �I.E i�
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings'of this;product.
5.4 TRI-BUILT Roof Underlayments may" be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. if not listed, a request may be made Co the
Authority Having Jurisdiction "for approval based on this evaluation combined with.supporting data for the
prepared roof covering.
5 5 Allowable roof covers applied atop the.underlayments are as follows:
� � .,. , tF: E
to 1� Root CQu� ri)P ai
3 f ,e�E i
�£ k�; �-r�
E.� y _ Y %'•'3" `i}.
P �
Asphalt
j Nail-Onlile Foam -on Tile
Metal
Wood Shakes
g� Shingles
Slate
Underlayment Shingles
S
iTri-Bul►t Sand-R SA.Shingle Yes
No
No
No
Yes
Yes
Underlayment
-
Tri-Built S/A HTTU� Yes
Yes
i Yes
Yes
Yes
Yes
E
Underlayment i
See 5.5.1
Tri-BuiltSmooth HT S/A yes
No
Na
Yes
Yes
{{{
Yes•
Underlayment
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless. tensile adhesion / long
term aging -data from an accredited testing laboratory is provided.
Y Tri-Built S/A HT TU.Underlayment with iCP Adhesives "Polyset AH-160" (FL6332) or Dow Chemical
"TileBond"I Roof Tile Adhesive" (FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck,
Tri-Built Sand-fi SA Shingle .Underlayment, Tri-Built S/A. HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
r Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete:
.While not required over plywood, OSB or Southern Yellow Pine. substrates, TRi-BUILT.Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within,.24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underiayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Y Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering rnanufacturer's Product Approval. For installations,
under foam -on tile systems {Tri-Built S/A HT TU Underlayment only insulation attachment shall be
designed by a qualified design professional and installed based on testing of'.the insulation/underlayment
system in accordance with FM 4474, Appendix D or T¢S 114, Appendix 1.
Exterior Research and Design, LLC: Evaluation ftepprtA42460.10:12-Fi5
Cerdfrcote of Authorization t19503 FBCNON-HVHZ EVALUATION FLIS048-95
Tri-Sailt Materials Group; LLC. Revision 5: 06/12/2017
Page 3 of 6
. ...... TY [ERD
' I
5.6.3 Bond to Mechanically. Attached Base Laver:,
Tri-Built Sand-R, SA Shingle Underlayment, Tri-Built: S/A HT TU Underlayment or Tri-Built: Smooth HT S/A
Underlayment applied to:
> ASTM D226, Type I or 11 felt.
For installations under mechanically attached prepared roof coverings,, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements' of FRSA/TRI ApM 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all Underlayment systems beneath foam -on tile systems, where
the Underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems.that are not addressed in.FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind. loads, and reflects the ultimate passing. pressure divided by 2 (the 2 to 1 margin :of safety
per, FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2612 (04-12) or FBC 1609 for
determination of design wind pressures.
5.6.4.1 Maximum Design Pressure =-45.0 psf:
Deck:. Min. 15/32-inch. plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-BuiltS/A HTTUUnderlayment,self-adhered.
5.6.4.2 Maximum Design Pressure--67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction. .
Primer: Soprema Elastocol 600c
Underlayment: Tri-BuiltS/A.HTTUI Jnderlayment,.seif-adhered.
5.6.4.3 Maximum Design Pressure = -150,0 psf;
Deck; Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project.
requirements to satisfaction of�Authority Having Jurisdiction.
Deck. Preparation: Plywood shall :be.. thoroughly cleaned. to remove dust and debris that may inhibit
adhesion. All sheathing' fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIORPRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roil using hand
roller and/or weighted roller to. ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
5.6.4.4 Maximum Design Pressure = -60.0 psfi
Desk: Min. 19/32=inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction,
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c.'at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built•S/A HT TU Underlayment, self -adhered.
5.7 Exposure Limitations:
5.7.1 Tri-Built Sand-R SA Shingle Underlayment. or Tri=Built Smooth 14T S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built S/A HT-TU Underlayment shall not.be.left'exposed for longer than 180-days after installation.
Exterior Researckand Design; MC. FBC
Report A42960.10.1?.rRS
Certificate of Authorization #9503 FBC PdO�1 Nyii2 EVALt3A flOtd FLT 604&RS
Revision 5:06o
Tri-Built Materials:Group, iLPage 4, C., ge 4 f 6
. of 6
6. INSTALLATION:
6.1. TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject, to the Limitations set forth in Section. 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels; and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Trt Built Sand R SA Shingle Underlayment Tri Built S/A HT TU Underlayment or Tri-Built Smooth HT S A
Underiaynient:
6.3.1 Shall be installed in compliance with the. requirements. for ASTM D19.70 underlayment in .FBC Sections'
1507 for the=type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While, priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours,
Apply sheet parallel to the roof edge.. Roll out approximately
ft of membrane and''peel back ttie,first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
once the entire length of membrane.is in place, peel -off the release ;film diagonally while holding the
membraiie'tight. Firmly roll, broom or hand -press the membrane into place to achieve;a bond.
Horizontal seams. should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and•staggered not less than'2-ft from vertical�seams in the course below; sealed in accordance. with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above•8:12, TRI-BUILT Materials Group, LLC •recommends back -nailing. in the
overlap area at the top of the•sheet at 12-inch p.c.
For Valleys and Ridges: Cut.underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and 'press sheet into place, working -from the:center of the.valley or ridge in
each direction. For valleys, apply the sheet.starting°at the.lowest point and worlkupward.
6.3.3. Tile Applications (Tri-Built S A HT TU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) installation k4anual and Table 1 herein, using the
instructions noted ;above as a guideline.
For -foam on the applications, reference:is made to Section 5.6.4 herein for wind resistance limitations.that
fall outside the scope of FRSA/TRI Apri12012 (04-12).
Tile • shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
Tri-Built S/A HT TUUnderlayment has met the tile slippage test requirements specified in.FRSA/TRI April
2012 (04-12) up to a 10-tile stack to a maximum roof pitch of 6:12 for flat tiles and 5:12 for lugged tiles.
Lugged tiles staged at pitch > 5:12 may use alternate staging method (bottom •2-tile stack shall be inverted,
followed by 8 tiles high on slope; as shown below).
Evaluation Report A42960.10.12-115
Exterior Research; and`Design, L!C_
EBC NoN-HVHZ.EVALUATi4N Ft16048-R5:
Certificate ajAuthorization!19503 Revision 5:06112/2017
Tri-Built Materials Group; LLC. page 5 of 6
VA
8.
9.
9.
i
INM ER
Figure 1: Alternate Staging Method
Alternatively, at roof slopes.greater than these limitations, all tiles shall be loaded onto a nominal V" x r
horizontal batten to prevent slippage or damage to the underiayment..
BUILDINGPERMIT REQUIREMENTS:
As required by the. Building Official or Authprity Having Jurisdiction in order to properly evaluate the installation of
this product.
MANUFACTURING PLANTS:
contact the noted QA agency for information on product locations covered for O.A.C. Rule 91V-3 QA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report A42960.10.127R5
certificate of Authorization #9503 FBC KoN-HVHZ EVALUATION FL16048-R$
Tri-Built Materials Group, LLC. Revision 5: 06/12/7017
Page '6:of 6