Loading...
HomeMy WebLinkAboutPLAN & PROPOSED WORK#16 Hermosa Lane Port St. Lucie, FL The scope of work for this project consists of replacing damaged columns, beams and roof as a result of storm damage. This repair has been designed in accordance with the requirements of the 2014 Florida Building Code, Fifth Edition - Residential, Chapter 3, Section R301.2.1. The following wind load requirements, in accordance with 2014 Florida Building Code, Fifth Edition - Building, Chapter 16, Structural Design, Section 1609 and ASCE 7-10 were employed in the design of the structure: Ultimate Design Wind Speed (Vuit): 150 MPH 3-Second Gust Wind Speed (V.a): 116 MPH Risk Category: I Wind Exposure Category: B Applicable Internal Pressure Coefficient: +/- 0.00 Design Pressure for Exterior Components & Cladding: • Walls = Existing • Roof = +/-15.0 PSF 137-9 c DEC 0 8 2017 BY................ ... Davis & Cleaton Engineering, Inc. 260 Wekiva Springs Road Suite # 1060 Longwood, FL 32779 FL P.E. License # 35816 171LE cup 4th M11 Detail 54' of 3 x V Rhino Steel Pons > 2"wU 10.w Cv 10.00' TV!, VIP 12.00' 9.w 11. ii 10.00' 10.00' 64' S V 21 x 41MB Existing Screen 9.w Room 9.0(y &J ST LUCIE p N BUILDING DIV Sl REVIEW-, FOR REVIEWED 8 COMP A DATE t e PLANS AND P IT 6JS i BE I4EPT Otd JOSOR NO INSPECTIOIN Aj 1Y W11 L BE -4 'PLANS 3 x 3 Past will be cull in rem scmn wall and attached to THESE AND ALL PROPOSED WORK new 3 X 3 trim misting framing. lCdWW� vAl d= up Woe that ARE SULIJECT TO ANY C RRE 6 0 CTION 9.09 ee, �� 7 10-Wisfimhmmlo4diwallposton REQUIRED-DY HELD INSPECTft'i THAT 1 rear wall. CONCEALED FASTENERS OR ATTACHMENTS MAYBE NECESSARY IN ORDER. d COMPLY WITH AU. APPLICABLE CODES. 12' ARE THE RESPONSIBIR OF THE LA C\t*mn I twa 4,,3A CONTRACTOR OF RECORD SCALE: N.T.S. Existing Factory Site Beam Attach Roof Panel to Header (4) #12 x 3/4" S.D.S. w/ 314" Pan Washer Per 12" Panel Caulk All Exposed Screws Attach Channel to Wood Using (1) #12 Wood Screws w/ 1.5" (MIN.) Thread Penetration @ 6" O.C. qv=.) Staggered CM-) ......\\\\`,�\\l: Ffflml- 'E —Y x 0.050" Aluminum Channel Pan Roof to Factory Site Beam Aluminum Framing Member (TYP.) Knee Brace to Beam Using "U" Channel w/ (3) #10 x 1/2" S.M.S. Into Alum. Post & (3) 910 x 1/2" S.M.S. into Knee Brace on Both Sides (MIN)(TYP) — 2" x 3" Hollow @ 2'-0" (MIN.(TYP.) Knee Brace to Column Using "U" Channel w/ (3) #10 x 1/2" S.M.S. Into Alum. Post & (3) #10 x 1/2" S.M.S. into . Knee Brace on Both Sides (MINXTYP) 3" x 3" Column (TYP.) Knee Brace to PostBeam (2) 3/8" x 4" Corrosive Resistive Thtu-Bolts w/ Nuts & Washers (TYP = 3" x 3" Aluminum Post (M.) Aluminum Base Plate .125"' (MIN.) Thickness Existing Reinforced Concrete Foundation (TYP.) (To Be Field Verified) Post to Base Connection (2) 3/8" L.D.T. w/ 3.5" (MIN.) Embedment into Solid Concrete w/ 3" (MIN.) Edge Distance (TYP.) x 12" Rhino Pan Roof(TYP.) NOTE: Provide AddirionalFlashin AsNe 3" Pan Roof (TYP.) Attach Roof Panel to Framing Memo-- (4) #12 x 3/4" S.D.S. w/ 3/4" Alumi Pan Washer Per 12" Panel Caulk All F-,q)o ¢d Screws Side Notch Is Acceptable (4) 3/8" x- 4" Corrosive Resistive Thru-Bolts w/ Nuts & Washers (TYP.) 3" x 3" Aluminum Post (TYP.) 2" x 6" S.M.B. Stitched Together Using (1) #12 x 3/4" S.D.S. Q 18" O.C. (MAX.) Top & Bottom (TYP.) Post to Beam Connection - Center Notch Pan Roof to Framing Member Material List: 6005A-T61 Alloy 2" x 6" x 0.050" x 0.120" S.M.B. 3" x 3" x 0.092' Post 3" x 0.018' Rhino Pan Roof 3" Rhino Pan Roof Panel (TYP.) Uuminum Framing Member (TYP.) U 'O O a 00 ' N M c �O N P, a CO � W a to C n C-x try N en •� C� ON to O in W) t- W bA� O .¢4on Cd ►� FQ U > o e Old3�M ANaa a� 1w a Date: 10/27/17 PAGE- 2 of 2