HomeMy WebLinkAboutAMERICAST GENERATOR CONCRETE PADn 0 0 T) AM E RICAST GENERATOR CONCRETE PA GENERATOR_._ � I Lu PAD DIMENSIONS: CONCRETE PAD GENERATOR - GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMERICAST 5vreviemer!•cestinaeom `I L� �`., 1f .•DfADID IN AMIDRIOAI' ,` ti`-: � F® rwx f 20.R53M UcEDM O5➢93DOS0I53 S303 Emma¢. Am Fen PjnM FL 34912 T.I. 771-971-IMBF-- 7724644)dOD. Z I•JNL1: 11Ely .nM-tltN�L�mnr eF..ler.ledHllfilwbnien r� HVHZ OR NON-HVHZ RISK EXPOSURE RISK EXPOSURE BRISK'., (; °EXPOSURE-- a ' COUNTY P. BEACH 150 MPH 32.43 Psf 39.33 Psf 170 MPH 41.65 Psf 50.55 Psf 180 MPH` 4(Ob psf 56:67 Fsf BROWARD 156 MPH 35.08 Psf 42.57 Psf 170 MPH 41.65 Psf 50.55 Psf 180 MPH 46.70 Psf 56.67 Psf MIAMI-DADE 165 MPH 39.24 Psf 47.62 Psf 175 MPH 44.14 Psf 53.57 Psf 186 MPH 49.86 Psf 60.52 Psf BRAND MODELS CAPACITY" f LENGTH : 4 ) % WIDTH ` j, rHFIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS QT02224ANAX --22KW -62.2 in'� ,29:0 in° 33.5 in 843 lb 60.52 Psf RG022 / RG02224ANAX I C-22KW._ 62.2 in t30.6 in, 38.6 in 905 lb 60.52 Psf RG025 / RG02515A ALUM - 25KW � '62.2 in 730.6 in : 38.6 in 777 lb 60.52 Psf RG025 / RG02515S STL 25KW cam_.. 62 2,in j 30.6.in� -38:6 in 865 lb 60.52 Psf RG027 / RG02724ANAX 27KW-_. 62r2-in` '30.6 in 38.6 in 940 lb 60.52 Psf RG030 / RG03015ANAX ALUM 30KW "6ZP 'in 30.6 in 1 38.6 in 807 lb 60.52 Psf RG030 / RG03015ANSX STL v 30KW, [I F,, F62 2 m- 30 61n Fj, 38 6 in, 895 lb 60.52 Psf RG032 / RG3224ANAX g.a ; ??132KW (� `!76.8 in� a 35.Oiin 1' 46A.in 1225 lb 60.52 Psf UP TO EXPOSURE v RG036 / RG03624ANAX ALUM 1__36KW' �-- ' k76.8 in= Is35 Orin` 46.1 in 1202 lb 60.52 Psf D 186 MPH RG036 / RG03624ANSX STL t --36KW !' j 766 in- '-35'0in= 46.1 in 1255 lb 60.52 Psf RG038 / RG3824ANAX 38KW 76.8 in 35.0 in 46.1 in 1235 lb 60.52 Psf RG045 / RG452ANA(C)(X) ALUM 45KW 76.8 in 35.0 in 46.1 in 1260 lb 60.52 Psf RG045 / RG452ANS(C)(X) STL 45KW 76.8 in 35.0 in 46.1 in 1313 lb 60.52'Psf RG048/ QT048 / RG4854ANA(C)(X) 48KW 76.8 in 35.0 in 46.1 in 1555 lb 60.52'Psf RG060 / ALUM 60KW 76.8 in 35.0 in 46.1 in 1422 lb 60.5-2 Psf RG060 / STEEL 60KW 76.8 in 35.0 in 46.1 in 1539 lb 60.52. Psf 24RCL / 30RCL 24KW 1 33.0 in 74.0 in 46.0 in 12601 60.52 Psf L 30RES 30KW 34.0 in 72.8 in 36.8 in 1046 lb 60.52 Psf UP TO EXPOSURE D 186 MPH Y 30REOZJB 30KW 34.0 in 78.7 in 50.2 in 1560 lb 60.52 Psf B8S 076000 30KW 34.0 in 78.7 in 50.2 in 1560 lb 60.52 Psf UP TO EXPOSURE GE 076034 30KW 39.5 in 84.5 in 41.5 in 1800 Ib 60.52 Psf D 186 MPHil CONCRETE PAD 1� ROAD MESH MASTERFIBER MAC100 r r r- n r 4" MIN s ��L[I• n u r wI GROUND /•.: i ; / :- /. _� `2„ MIN • _ _ - -- 45" TYP. 1 41 TYP. GENERATOR MOUNTING CONFIGURATION: GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE GENERATOR W/ (4) #SO SS 316 SELF -DRILLING SCREWS TO GENERATOR (SEE GENERATOR SPECS) WIND DESIGN REOUIREMENTS_ (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE FIFTH EDITION (2014)) AT -GRADE SIGN METHOD ' ULTIMATE DESIGN WIND SPEEDS Vult = 186 mph NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Cf = 1.53 WIND PRESSURE:: P = qh G Cf = 60.52 Ib/ft2 (ASD) GENERAL NOTES ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION (4)-3/8"0 TITEN HD CONCRETE: OR EQUIVALENT, 2" (6000 PSI FULL EMBED TO MIN.) CONCRETE, 3" MIN. EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE /-'"-EXCLUDES FINISHES, IF _APPLICABLE: -- 3 ENSURE MINIMUM EDGE DISTANCE ^ASS NOTED�IN ANCHOR SCHEDULE. .ENSURE MINIMUM SPACING TO _ GENERATOR `ATITACFiMENT BASE VARIES=WITH MODEL 'g-- SEEE'GENERATORSPECS; _ " SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"x3/8' GALV. STEEL WASHER RUBBER VIBRATION PAD 3/8' THICK T GALVANIZED WASHER. I i~ & RUBBER j I` VIBRATION -PAD C _ = GENERATOR Z i .U. .U. (SEE CONCRETE PAD SCHEDULE FOR 1` f 1 'CONCRE'fE PAD' , w W DIMENSIONS & WEIGHT REQUIRED) 000 f r LIGHTWEIGHT .--` . _\ CONCRETE MIX I Y 4" r �4NOTES:I. i >l w-Y DISTANCE=DEPEND�ON=GENERATOR BASE LENGTH, NO LESS THAN 2 OR ANCHOR REQUIREMENT. } 47" WIDTH } 45" LENGTH --�-- 45" LENGTH X DiSTANCE_3";FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS SIDE VIEW FRONT VIEW THAN ANCHOR REQUIREMENTS CONCRETE PAD 6,000 PSI LIGHTWEIGHT CONCRETE MIX MASTERFIBER MAC 100 & ROAD MESH FOAM CORE TO f--Z„--� 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 20 14 FLORIDA BUILDING CODE (5th EDITION). 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN -ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS.THAN=OR EQUAL TO THE DESIGN=PRESSURE"ASD_CAPACITYLUES LISTED HEREIN FOR ANY-ASSEMBL•Y AS SHOWN ; 3. DIMENSIONS AND WEIGHT'OF-UNITS}SHALL CONFORM TO 4. UNITS MUST BE CENTERED ON -PAD WITH•OPPOSITE SIDES HAVING EQUAL CLEARANCE A -MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED -'--_ - 5. THE AREA UNDER CONCERETE' SLAB ON GROUND -SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION=ON COMPACTED SOIL AS VERIFIED BYr�OTHERSa 6. RESISTANCEITO`SLIDING'OFITHE,, AD ON THE GROUNDIIS NO,T PART OF THIS DOCUMENT AS SOIL, CHARACTERISTICS AND PAD PLACEMENT VARIE°�j7 1� = "R' S ft 7. ELECTRICAL GROUND; H9N'REQUIREb TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. B. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 9. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE E COORDINATED BY THE PERMITTING CONTRACTOR _ 11. THIS DOCUMENT IS GENERIC AND -DOES NOT -PERTAIN -TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR=SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL-IVOT BE-HELD'RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS IIDIMENSIONS.ARE SHOWN TO,ILLUSTRATE DESIGN FORCES ANDS OTHERDESIGN CRITERIAITHEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE_L'IMITATIONS SPECIFIED HEREIN. WORK SHkL_ `BE FIELD;VERIFIED BY OTHERS PRIOR TO CONSTRUCfIONJEENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE�OUR WORK UPON DISCOVERY`OF ANY w , INACCURATE-INFORMATIONPRIOR'TO•MODIFICATION"6F'm-- ' EXISTING FIELD CONDITIONS AND'FABRICATION AND :, INSTALLATION OF;MATERIALS. ALTERATIONS OR,A6 TIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. W L. BENNARDO, P.E. 0046549 2 CAEC%EO, CERTIFYING P.E MPEAr3&ROG NK L. BENNARDO, P.E. � N Z O� mUE v m oIn Ln r W� WN W11L wV)LL nxLu4 O Y_ o:x Z C9 F->< WLU< Q LL W �QWow(7-0 O.imoZZ.F W W 1I: N Z LLI LU O_j In r� o U O tWE 'o� _ J ID �=w U) W O W iu F-�/� w V / Q L1- °2In .M O W .�-I N U , U �,4 0 W i O_ N Z o a O LL 9 H r^ Ill awn L9 W ~ d-oj o O v m Q Inw Y 0 ri M I- LL w 0 w w 0O � 0 ^ M O Z U �g(D 2 Ya z r O Co t/9111LL LO 0 ZE .E7 ii ic W®@RT O LLi a a F A w5 •o Q C rn EE a z all V ULL OLYU I-E 3Oo i; 0 5 5 �oz2 wwII a io m co Mix. zoomed o osIu of N WQ 12 F- o w 1-fa=Eg K 2- t='d3aa COPYRIGHT ENGINEERING EXPRESS 17-3961.2 SCALE: NTS UNLESS NOTED OF