Loading...
HomeMy WebLinkAboutGENERATORSeries INCLUDES: • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) with external 'viewing window for easy indication of generator status and breaker position. • True. Power TM Electrical Technology • isochronous Electronic Governor • Sound. Attenuated Enclosure • Closed Coolant Recovery System Smart Battery Charger • UV/Ozone Resistant Hoses • ±1%Voltage Regulation • Natural Gas or LP Operation • 5 Year Umited.'Warranty • UL 2200 Listed FEATURES PROTECTORS QS SERIES Standby Generators Liquid -Cooled Gaseous Engine Standby Power Rating Model RGO22 (Aluminum - Gray) - 22 kW 60 Hz Model RG027 (Aluminum _ Gray) - 27 kW 60 Hz Model RG032 (Aluminum - Gray) - 32 kW 60 Hz Model RG038 (Aluminum - Gray) - 38 kW 60 Hz Model RG048 (Aluminum - Gray) 4.0ul QUIEHEST-- LISTED ,...�: °'°'•^' Meets EPA Emission Regulations 22 & 27 kW are CA/MA emissions compliant 48 kW meets CA/MA emissions requirements with optional catalyst 32 & 38 kW not for sale in CAIMA Q INNOVATIVE DESIGN L PROTOTYPE TESTING are key components of GENERAL'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, atIows.you to choose .GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. O TEST CRITERIA., ✓ PROTOTYPE TESTED V SYSTEM TORSIONAL TESTED O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state -of -the -art -power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load.conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at -*1°k. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ✓ NEMA M01-22 EVALUATION O GE€�EIIAC TRANSFER SWITCHES. Long life and reliability are MOTOR STARTINO'ASILITY synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes_ its own transfer systems and controls for total system compatibility. so r.n.wuey. 9001: GENERAC° 22 • 27 • 32 • '38 • 48 kW application & engineering data GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 22, 27, 32 & 38 Itlh! Type Synchronous Rotor Insulation Class H (22 & 27 kW) or F (32, 3B & 48 kW) Stator Insulation Class H Telephone Interference Factor (T1F) <50 Alternator Output Leads 1-Phase 4 wire Alternator Output Leads 3-Phase 6 wire Bearings Sealed Ball Coupling Flexible Disc Excitation System Direct VOLTAGE REGULATION Type Electronic Sensing Single Phase. Regulation ± 1% GOVERNOR SPECIFICATIONS Type Electronic Frequency Regulation isochronous Steady State Regulation ± 0.25% ELECTRICAL SYSTEM Battery Charge Alternator 12 Volt 30 Amp Static Battery Charger 2.5 Amp Recommended Battery (battery not included) Group 26 (22, 27, 32& 38 kW) or Group 24F (48 kW), 525CCA System Voltage 12 Volts GENERATOR FEATURE$ Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Class H insulation is NEMA rated Class F insulation is NEMA rated. All models fully prototyped tested ENCLOSURE FEATURES Aluminum weather Ensures protection against mother nature. protective enclosure Electrostatically applied textured epoxy paint for added durability: Enclosed critical grade Quiet, critical grade muffler is mounted inside the unit muffler to prevent injuries. Small, compact, attractive Makes for an easy, eye appealing installation. SAE I Sound attenuated enclosure ensures quiet operation. (All ratings in accordance with BS5514, IS03046, ISO8528, SAE J1349 and DIN6271) Make Generac Model In -line Cylinders 4 Displacement (Liters) 2.4 Bore (in/mm) 3,41/86.5 Stroke (tn/mm) 3.94/100 Compression Ratio 9.5:1 Intake Air System Naturally Aspirated (22 & 27 kW) or Turboctrarged/Aftercooled (32 & 38 kW) Lifter Type Hydraulic ENGINE SPECIFICATIONS: 48 IM Make Generac Model VType. Cylinders 8 Displacement (Liters) 5.4 Bon; (in/mm) 3.55/90.2 Stroke (in/mm) 4.17/105.9 Compression Ratio 9:1 Intake Air System Naturally Aspirated Lifter Type Hydraulic ENGINE LUBRICATION SYSTEM Oil Pump Type Gear Oil Filter Type Full flow spin -on cartridge Crankcase Capacity (qVI) 4/3.8 (22, 27, 32 & 38 kW) or 6/5.7 (48. kW) ENGINE COOLING SYSTEM Type Closed Water Pump Belt driven 1980 - 22 & 27 kW Fan Speed (rpm) 1500 - 32 & 38 kW 1954 - 48 kW Fan Diameter (in/mm) 18.1/459.7 (22 & 27 kW) or 22/558.8 (32, 38 & 48 kW) Fan Mode Pusher (22 & 27 kW) or Puller (32, 38 & 48 kW) FUEL SYSTEM Fuel Type Natural gas, propane vapor Carburetor Down Draft Secondary Fuel Regulator Standard Fuel Shut Off Solenoid Standard Operating Fuel Pressure 5-14" water cdlumn/9-26 mm HG GENERAC° 22 • 27 • 32 • 38 •48 kW operating data GENERATOR OUTPUT UQLTAGE,IlM - 60,11z kW LPG Amo LPG kW NaL Gas Amn Nat- Gas PR si7n /Rnthl 120/240 V,10,1.0 pf 22 92 22 92 100 RG022 120/208 V 30, 0.8 pi 22 76 22 76 80 120/240'V 30, 0.8 pf 22 66 22 66 80 120/240 V 10,1.0 pi 27 113 25 104 125 RG027 120/208 V, 30, 0.8 pf 27 94 25 87 100 120/240 V. 30, 0.8 p1 27 81 25 75 90 120/240 V 10,1.0 pf 32 133 32 133 156 RG032 120/208 V 30, 0.8 pf 32 111 32 111 125 120/240 V, 30, 0.8 pf 32 96 32 96 100 277/486 V 30, 0:8 pf 32 48 32 48 .60 120/240 V.10,1.0.pf 38 158 38 158 175 RGO38 120/208 V 30, 0.8 pf 38 132 38 132 150 120/240 V, 30, 0.8 pf 38 114 38 114 125 277/480 V. 30, 0.8 pf 38 57 38 57 60 120/240 V 10,1.0 pf 48 200 48 200 200 RG048 120/208 V. 30, 0.8 pf 48 167 48 167 175 120/240 V, 30, 0:8 pf 48 144 48 144 150 277/480 V 30, 0.8 pf 48 72 48 72 80 SURGE CAPACITY 114 AMPS Voltage Dip @ < .4 pf 15% 30% 120/240 V 10 55 135 RGO22 120/208 V. 30 40 92 120/240 V 30 35 80 120/240 V, 10 62 170 RG027 120/208 V. 30 70 120 120/240 V 30 61 103 RG032 120/240 V 10 75 180 120/208 V 30 87 210 120/240 V 30 75 182 277/480 V, 30 36 87 120/240 V. 10 75 180 RG038 120/208 V. 30 87 210 120/240 V, 30 75 182 277/480 V 30 36 87 RG04B 120/240 V, 10 85 195 120/208 V, 30 90 '21 B 120/240 V 30 7B 189 277/480 V. 30 36 87 Note: Fuel pipe must be sized for full load. For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAOMD permitting purposes. ENGINE FUEL CONSUMPTION Natural Gas Propane rft3/hr1 fm3/hr) (nal/hr) rl/hr) /ft3/hrl Exercise cycle 42 1.2 0.44 1.7 16 25% of rated load 100 2.8 1.1 4.2 40 RG022 50% of rated load 190 5.4 2.1 7.8 75 75% of rated load 255 7.2 2.8 10.5 101 100% of rated load 316 9 3.4 13 125 Exercise cycle 42 1.2 0.44 1.7 16 25% o1 rated load 108 3.1 1.2 4.5 43 RG027 50% of rated load 197 5:6 2.1 8.1 78 75% of rated load 287 8.2 3.1 11.8 114 100% of rated load 359 ' 10.2 3:9 14.8 143 Exercise cycle 79 '2.2 0.8 3.2 30 RG032 25% of rated load 144 4.1 1.7 6.3 60 50% of rated load 226 6.4 2.7 10.3 97 75% of rated load 298 6.4 3.7 13.9 132 100% of rated load 375 10.6 4.6 17.5 166 Exercise cycle 83 2.3 0.9 3.2 31 25% of rated load 162 4.6 1.7 6.6 62 RG038 50% of rated load 255 7.2 2.9 10:8 103 75% of rated load 345 9.8 4 15 142 100% of rated load 437 12.4 5.2 19 185 Exercise cycle 95 2.7 1 j 3.9 38 . 25% of rated load 204 5.8 2.16 8.5 82 RG048 50% of rated load 392 11.1 4.14 15.7 151 75%of rated load 547 15.5 5.8 22.8 220 100% of rated load 756 21.5 7.96 31.3 302 STANDBY RATING': Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design'and specifications are subject to change without notice. GENERACO 22 • 27 • 32 •38 •48 kW available accessories Model # Product Description Generac's Mobile Link allows you to check the status of your generator from ' } 006463-3 i Mobile LinkTM 1 anywhere that you have access to an Internet connection from a PC or with ; any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. Note: Harness Adapter Kit required. Available in the U.S. only. 006478-0 ;Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with ! Mobile Link—. 005630-1- 22, 27, 32 & 38 kW ` f Cold Weather Kit !'If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit i to maintain optimal battery temperature. Kit battery 005632-1 - 48 kW consists of warmer with t thermostat built into the wrap. 005616-0 - 22, 27, 32 & 38 kW i Extreme Cold Recommended where the temperature regularly falls below 32 OF (0 °C) for 006204-0 - 48 kW ' Weather Kit : extended periods of time. For liquid cooled units only. , 005651-0 ; Base Plug Kit I Add base plugs to the base of the generator to keep out debris. If the generator enclosure is scratched or damaged, it is important to touch-up 005704-0 Paint Kit the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 005656-0 - 22 & 27 kW j 005984-0 - 32 & 38 kW Scheduled Maintenance Kit The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware necessary 006205-0 - 48 kW to perform complete maintenance on Generac liquid -cooled generators. 006664-0 Y Local Wireless Completely wireless and battery powered, Generac's wireless remote monitor i Monitor provides you with instant status information without ever leaving the house. 006665-0 'Wireless Remote ! Recommended for use with the Wireless Remote on units up to 60 kW, required Extension Harness i for use on units 70 kW or greater. i Smart Management Modules are used in conjunction with the Automatic 006873-0 ( Smart Management ' Transfer Switch to increase its power management capabilities. It provides I Module (50 Amps) additional power management flexibility not found in any other power management system. 006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency. RADIATORIEXHAUST DISCHARGE AIR AIR INTAKE (BOTH SIDES) BATTERY 12 (BOTH SIDES) NEGATIVE GRP 26 GROUND n Q PIN: D58208 2\/y 508 (20.0) —�I 24D H— (9.4) REMOVE COVET FOR ACCESS TO RADIATOR FILL LAP EXHAUST MUFFLE ENCLOSED WITHIN GENERATOR ENCLOSUR kD[ATORIEXHAUSI DISCHARGE AIR 1 ty s� 72T.4—►) CENTER OF GRAVITY (SEE NOTE 5) TOP VIEW REFERENCE OWNERS MANUAL FOR PERIODIC REPLACEMENT PART LISTINGS. CIRCUIT BREAKE SEE NOTE 3 146.11 OVERALL yy �T ,•-os �' HEIGHT I I BBB {35 Oj- v w 0 NOTES: W D ,, 1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47-).WIDE X 2256(BB.B") LONG. 1 REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES. 2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE O ', •AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA 77 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, v STATE, AND LOCAL CODES. 3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION: - SEE SPECIFICATION SHEET OR OWNERS MANUAL -ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR. 4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS THE STUD -UP AREAS AS FOLLOWS: - HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION NEUTRAL CONNECTION. BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION. - LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES. 5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS. B. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW. 7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS. 6. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE SI&11 GRADE 5 (USE STANDARD SAE TORQUE SPECS) 0. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS. 10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED. 11. EXHAUST MUFFLER AND FAN BEET ENCLOSED WITHIN GENERATOR ENCLOSURE, REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH, ONE PER DOOR, [+— 759 [29.9]—►{[OF DO DOOR TYP ONE LIFT OFF IODOR PER SIDE GENERATOR 4 '-REAR ENCLOSURE COVER PANEL �l SEE NOTE 4 i--CUSTOMER ACCESS ASSEMBLY, CONTROL PANELACCESS, BATTERY CHARGER LOCATED WITHIN 8EE NOTE q ,. ' 670 OVERALL WIDTH 47 FUEL LINE CONNECTIONS 3/4" NPT FEMALE COUPLING LEFT SIDE VIEW REARVIEW WEIGHT DATA WDGHT WEIGHT ENOINMW MA7ER4LLE DENSET W&Y bHIPPING SKID N0(LWE=ff KO L&5 KOsi IM S.IIpeKW AL I 705p2M 44tNI 7501 58 [2.31 TYP !QSSeries GENERACO Mlrr, , 48 kW installation layout Drawing #OK9243-A (2 of 2) Lu J O U ,p O 77 .- Lu F w K N U K W O It w a ZA a? 0 J U 0;z z Nf k Z GENERACA .a o rn D LaI� aw _ o O u> _Cn <�¢ io m z m W CO 0 U Z Z 0 M z ca w y� t Lo N Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin CLO036SUY-C Printed in U.S.A. 07/21/15