Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutGENERATORSeries
INCLUDES:
• Two Line LCD Multilingual Digital
Evolution TM Controller (English/Spanish/
French/Portuguese) with external
'viewing window for easy indication of
generator status and breaker position.
• True. Power TM Electrical Technology
• isochronous Electronic Governor
• Sound. Attenuated Enclosure
• Closed Coolant Recovery System
Smart Battery Charger
• UV/Ozone Resistant Hoses
• ±1%Voltage Regulation
• Natural Gas or LP Operation
• 5 Year Umited.'Warranty
• UL 2200 Listed
FEATURES
PROTECTORS QS SERIES
Standby Generators
Liquid -Cooled Gaseous Engine
Standby Power Rating
Model RGO22 (Aluminum - Gray) - 22 kW 60 Hz
Model RG027 (Aluminum _ Gray) - 27 kW 60 Hz
Model RG032 (Aluminum - Gray) - 32 kW 60 Hz
Model RG038 (Aluminum - Gray) - 38 kW 60 Hz
Model RG048 (Aluminum - Gray)
4.0ul QUIEHEST--
LISTED ,...�:
°'°'•^' Meets EPA Emission Regulations
22 & 27 kW are CA/MA emissions compliant
48 kW meets CA/MA emissions requirements with optional catalyst
32 & 38 kW not for sale in CAIMA
Q INNOVATIVE DESIGN L PROTOTYPE TESTING are key components of
GENERAL'S success in "IMPROVING POWER BY DESIGN." But it
doesn't stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, atIows.you to
choose .GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
O TEST CRITERIA.,
✓ PROTOTYPE TESTED
V SYSTEM TORSIONAL TESTED
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state -of -the -art -power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load.conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at -*1°k.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
✓ NEMA M01-22 EVALUATION O GE€�EIIAC TRANSFER SWITCHES. Long life and reliability are
MOTOR STARTINO'ASILITY synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes_ its own transfer
systems and controls for total system compatibility.
so
r.n.wuey. 9001:
GENERAC°
22 • 27 • 32 • '38 • 48 kW application & engineering data
GENERATOR SPECIFICATIONS ENGINE SPECIFICATIONS: 22, 27, 32 & 38 Itlh!
Type
Synchronous
Rotor Insulation Class
H (22 & 27 kW) or
F (32, 3B & 48 kW)
Stator Insulation Class
H
Telephone Interference Factor (T1F)
<50
Alternator Output Leads 1-Phase
4 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Sealed Ball
Coupling
Flexible Disc
Excitation System
Direct
VOLTAGE REGULATION
Type
Electronic
Sensing
Single Phase.
Regulation
± 1%
GOVERNOR SPECIFICATIONS
Type
Electronic
Frequency Regulation
isochronous
Steady State Regulation
± 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator
12 Volt 30 Amp
Static Battery Charger
2.5 Amp
Recommended Battery (battery not included)
Group 26 (22, 27, 32& 38 kW)
or Group 24F (48 kW), 525CCA
System Voltage
12 Volts
GENERATOR FEATURE$
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Class H insulation is NEMA rated
Class F insulation is NEMA rated.
All models fully prototyped tested
ENCLOSURE FEATURES
Aluminum weather
Ensures protection against mother nature.
protective enclosure
Electrostatically applied textured epoxy paint for added
durability:
Enclosed critical grade
Quiet, critical grade muffler is mounted inside the unit
muffler
to prevent injuries.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
I Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, IS03046, ISO8528, SAE J1349 and DIN6271)
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
2.4
Bore (in/mm)
3,41/86.5
Stroke (tn/mm)
3.94/100
Compression Ratio
9.5:1
Intake Air System
Naturally Aspirated (22 & 27 kW) or
Turboctrarged/Aftercooled
(32 & 38 kW)
Lifter Type
Hydraulic
ENGINE SPECIFICATIONS: 48 IM
Make
Generac
Model
VType.
Cylinders
8
Displacement (Liters)
5.4
Bon; (in/mm)
3.55/90.2
Stroke (in/mm)
4.17/105.9
Compression Ratio
9:1
Intake Air System
Naturally Aspirated
Lifter Type
Hydraulic
ENGINE LUBRICATION SYSTEM
Oil Pump Type
Gear
Oil Filter Type
Full flow spin -on cartridge
Crankcase Capacity (qVI)
4/3.8 (22, 27, 32 & 38 kW) or
6/5.7 (48. kW)
ENGINE COOLING SYSTEM
Type
Closed
Water Pump
Belt driven
1980 - 22 & 27 kW
Fan Speed (rpm)
1500 - 32 & 38 kW
1954 - 48 kW
Fan Diameter (in/mm)
18.1/459.7 (22 & 27 kW) or
22/558.8 (32, 38 & 48 kW)
Fan Mode
Pusher (22 & 27 kW) or
Puller (32, 38 & 48 kW)
FUEL SYSTEM
Fuel Type
Natural gas, propane vapor
Carburetor
Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
5-14" water cdlumn/9-26 mm HG
GENERAC°
22 • 27 • 32 • 38 •48 kW operating data
GENERATOR OUTPUT UQLTAGE,IlM - 60,11z
kW LPG Amo LPG kW NaL Gas Amn Nat- Gas PR si7n /Rnthl
120/240 V,10,1.0 pf
22
92
22
92
100
RG022
120/208 V 30, 0.8 pi
22
76
22
76
80
120/240'V 30, 0.8 pf
22
66
22
66
80
120/240 V 10,1.0 pi
27
113
25
104
125
RG027
120/208 V, 30, 0.8 pf
27
94
25
87
100
120/240 V. 30, 0.8 p1
27
81
25
75
90
120/240 V 10,1.0 pf
32
133
32
133
156
RG032
120/208 V 30, 0.8 pf
32
111
32
111
125
120/240 V, 30, 0.8 pf
32
96
32
96
100
277/486 V 30, 0:8 pf
32
48
32
48
.60
120/240 V.10,1.0.pf
38
158
38
158
175
RGO38
120/208 V 30, 0.8 pf
38
132
38
132
150
120/240 V, 30, 0.8 pf
38
114
38
114
125
277/480 V. 30, 0.8 pf
38
57
38
57
60
120/240 V 10,1.0 pf
48
200
48
200
200
RG048
120/208 V. 30, 0.8 pf
48
167
48
167
175
120/240 V, 30, 0:8 pf
48
144
48
144
150
277/480 V 30, 0.8 pf
48
72
48
72
80
SURGE CAPACITY 114 AMPS
Voltage Dip @ < .4 pf
15% 30%
120/240 V 10
55
135
RGO22
120/208 V. 30
40
92
120/240 V 30
35
80
120/240 V, 10
62
170
RG027
120/208 V. 30
70
120
120/240 V 30
61
103
RG032
120/240 V 10
75
180
120/208 V 30
87
210
120/240 V 30
75
182
277/480 V, 30
36
87
120/240 V. 10
75
180
RG038
120/208 V. 30
87
210
120/240 V, 30
75
182
277/480 V 30
36
87
RG04B
120/240 V, 10
85
195
120/208 V, 30
90
'21 B
120/240 V 30
7B
189
277/480 V. 30
36
87
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG)
For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and
SCAOMD permitting purposes.
ENGINE FUEL CONSUMPTION
Natural Gas Propane
rft3/hr1 fm3/hr) (nal/hr) rl/hr) /ft3/hrl
Exercise cycle
42
1.2
0.44
1.7
16
25% of rated load
100
2.8
1.1
4.2
40
RG022
50% of rated load
190
5.4
2.1
7.8
75
75% of rated load
255
7.2
2.8
10.5
101
100% of rated load
316
9
3.4
13
125
Exercise cycle
42
1.2
0.44
1.7
16
25% o1 rated load
108
3.1
1.2
4.5
43
RG027
50% of rated load
197
5:6
2.1
8.1
78
75% of rated load
287
8.2
3.1
11.8
114
100% of rated load
359 '
10.2
3:9
14.8
143
Exercise cycle
79
'2.2
0.8
3.2
30
RG032
25% of rated load
144
4.1
1.7
6.3
60
50% of rated load
226
6.4
2.7
10.3
97
75% of rated load
298
6.4
3.7
13.9
132
100% of rated load
375
10.6
4.6
17.5
166
Exercise cycle
83
2.3
0.9
3.2
31
25% of rated load
162
4.6
1.7
6.6
62
RG038
50% of rated load
255
7.2
2.9
10:8
103
75% of rated load
345
9.8
4
15
142
100% of rated load
437
12.4
5.2
19
185
Exercise cycle
95
2.7
1 j
3.9
38 .
25% of rated load
204
5.8
2.16
8.5
82
RG048
50% of rated load
392
11.1
4.14
15.7
151
75%of rated load
547
15.5
5.8
22.8
220
100% of rated load
756
21.5
7.96
31.3
302
STANDBY RATING': Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There
is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design'and specifications are subject to change without notice.
GENERACO
22 • 27 • 32 •38 •48 kW
available accessories
Model # Product
Description
Generac's Mobile Link allows you to check the status of your generator from
'
} 006463-3 i Mobile LinkTM
1 anywhere that you have access to an Internet connection from a PC or with
; any smart device. You will even be notified when a change in the generator's
status occurs via e-mail or text message. Note: Harness Adapter Kit required.
Available in the U.S. only.
006478-0 ;Harness Adapter Kit The Harness Adapter Kit is required to make liquid -cooled units compatible with
!
Mobile Link—.
005630-1- 22, 27, 32 & 38 kW `
f Cold Weather Kit
!'If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit
i to maintain optimal battery temperature. Kit battery
005632-1 - 48 kW
consists of warmer with
t thermostat built into the wrap.
005616-0 - 22, 27, 32 & 38 kW i Extreme Cold
Recommended where the temperature regularly falls below 32 OF (0 °C) for
006204-0 - 48 kW ' Weather Kit
: extended periods of time. For liquid cooled units only.
,
005651-0 ; Base Plug Kit I Add base plugs to the base of the generator to keep out debris.
If the generator enclosure is scratched or damaged, it is important to touch-up
005704-0
Paint Kit
the paint to protect from future corrosion. The paint kit includes the necessary
paint to properly maintain or touch-up a generator enclosure.
005656-0 - 22 & 27 kW
j 005984-0 - 32 & 38 kW
Scheduled
Maintenance Kit
The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware necessary
006205-0 - 48 kW
to perform complete maintenance on Generac liquid -cooled generators.
006664-0
Y Local Wireless
Completely wireless and battery powered, Generac's wireless remote monitor
i Monitor
provides you with instant status information without ever leaving the house.
006665-0
'Wireless Remote
! Recommended for use with the Wireless Remote on units up to 60 kW, required
Extension Harness
i
for use on units 70 kW or greater.
i Smart Management Modules are used in conjunction with the Automatic
006873-0
( Smart Management
' Transfer Switch to increase its power management capabilities. It provides
I Module (50 Amps)
additional power management flexibility not found in any other power
management system.
006510-0
E-Stop
E-stop allows for immediate fuel shutoff and generator shutdown in the event of
an emergency.
RADIATORIEXHAUST
DISCHARGE AIR
AIR INTAKE
(BOTH SIDES)
BATTERY 12
(BOTH SIDES)
NEGATIVE
GRP 26
GROUND
n
Q
PIN: D58208
2\/y
508
(20.0)
—�I 24D H—
(9.4)
REMOVE COVET
FOR ACCESS TO
RADIATOR FILL LAP
EXHAUST MUFFLE
ENCLOSED WITHIN
GENERATOR ENCLOSUR
kD[ATORIEXHAUSI
DISCHARGE AIR
1 ty
s�
72T.4—►)
CENTER OF GRAVITY
(SEE NOTE 5)
TOP VIEW
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
CIRCUIT BREAKE
SEE NOTE 3
146.11
OVERALL yy
�T ,•-os �' HEIGHT
I I
BBB {35 Oj-
v
w
0
NOTES:
W
D ,,
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47-).WIDE X 2256(BB.B") LONG.
1
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
O ',
•AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 77 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
v
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
-ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUD -UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION. BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
B. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
6. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE SI&11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
0. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BEET ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS. VICE ACTION LATCH,
ONE PER DOOR,
[+— 759 [29.9]—►{[OF
DO
DOOR TYP
ONE LIFT OFF
IODOR PER SIDE
GENERATOR
4 '-REAR ENCLOSURE
COVER PANEL
�l
SEE NOTE 4
i--CUSTOMER
ACCESS
ASSEMBLY, CONTROL
PANELACCESS,
BATTERY CHARGER
LOCATED WITHIN
8EE NOTE q
,. '
670 OVERALL WIDTH 47
FUEL LINE CONNECTIONS
3/4" NPT FEMALE COUPLING LEFT SIDE VIEW REARVIEW
WEIGHT DATA
WDGHT WEIGHT
ENOINMW MA7ER4LLE DENSET W&Y bHIPPING SKID N0(LWE=ff
KO L&5 KOsi
IM
S.IIpeKW AL I 705p2M 44tNI 7501
58
[2.31
TYP
!QSSeries
GENERACO
Mlrr, ,
48 kW installation layout
Drawing #OK9243-A (2 of 2)
Lu
J O
U ,p
O 77 .-
Lu F w
K N
U
K
W
O It
w
a
ZA
a?
0
J
U 0;z z
Nf
k Z
GENERACA
.a o
rn D
LaI�
aw _
o O u>
_Cn <�¢
io m z m W
CO
0
U
Z
Z
0
M
z
ca w
y� t
Lo
N
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
©2015 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Bulletin CLO036SUY-C Printed in U.S.A. 07/21/15