Loading...
HomeMy WebLinkAboutEVALUATION REPORT POLYGLASS ROOF UNDERLAY MENTITPJNITYERD EVALUATION REPORT p— f--\ l :— twr r EXTERIOR RESEARCH & DESIGN, LLC. U2� Certificate of Authorization #9503 @@litGC 1 1 353 CHRISTIAN STREET, UNIT #13 PERMITTING PHONE: CT 06478 St. Lucie County, FL PHONE: (203) 262-9245 FAX: (203) 262-9243 Polyglass USA, Inc. Evaluation Report P12060.02.09-R15 150 Lyon Drive I'1 (Z C �l� FL5259-RZO Fernley, NV 98408 ST. LUCIE COUNTY BUILDENG n—M. SCIOti Date of Issuance: 02/24/2009 REVIEWED FOR COMPLIANCE Revision 15: 08/25/2014 REVIE:VED BY - -git2urJ=�-1� SCOPE: DATE I't r1 OB This Evaluation Report is issued % Tes and regulations governing the use of construction materials in the Sta!ON160naffle I--n^�tktb%ted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the Florida Building Code, 2010 sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation REnL�eROPt THESE consists of ARE SUBJECT TO ANY CORRECTIONS Prepared by: REQUIRED BY FIELD INSPECTORS THAT MAYBE NE ESSARY IN ORDER TO WITH ALL APPLICABLE CODES. Robert I.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4 ANE1983 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 08/25/2014 This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will. acquire, a financial interest in any other entity involved in the approval process of the product. File Copy ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.3, 2507.3.3, 1507.5.3, 1507.7.3, Physical Properties ASTM D226 2006 1507.8.3,1507.9.3 1507.2.4, 1507.2.9.2, 1507.3.3,1507.5.3 Physical Properties ASTM D1970 2001 1507.11.2 Physical Properties ASTM D6164 2005 1507.11.2 Physical Properties ASTM D6222 2002 1504.6 Accelerated Weathering ASTM G154 2005 1504.6 Accelerated Weathering ASTM G155 2005 1504.3.1 Wind Uplift FM 4474 2004 1507.3.3 Installation Practice FRSA/TRI 07320 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Entity r Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/32/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties Physical Properties PUSA-061-02-02 PUSA-076-02-01 02/28/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 02/22/2008 04/14/2008 PRI (TST 5878) Physical Properties PUSA 088-02.01 07/29/2009 MTI (TST 2508) Physical Properties 1X20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.66.02 01/16/2003 ERD (TST 6049) ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift Physical Properties P3740.01.07 P5110.04.07-1 01/04/2007 04/21/2007 ERD (TST 6049) ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 03/21/2008 ERD (TST 6049) Physical Properties Wind Uplift P13450.08.09 ERD (TST 6049) Physical Properties P30540.11.09-111 P11030.11.09-1 12/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 il/30/2009 11/30/2009 ERD (TST 6049) ERD (TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties Physical Properties P33360.06.30 P33370.03.11 06/25/2010 ERD (TST 6049) Physical Properties P33370.04.11 03/02/2011 04/26/2011 ERD (TST 6049) ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 ERD (TST 6049) Physical Properties Physical Properties 040390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 C41420.09.12-3 08/07/2012 09/11/2012 Exterior Research and Design, I.I.C. Evaluation Report P12060.02 09 R15 CertficateofAuthorizatlon 119503 FL5259-R20 Revision 15: 08/25/2014 Page 2 of 12 Y. \ ' ! �I 1 O Y , ERD Enti Examination Reference Date ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6649) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-131 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties P44360SC 05/15/2014 ERD (TST 6049) Physical Properties P46520.08.14 08/22/2014 ICC-ES (EVL 2396) IBC Compliance ESR-1697 09/01/2012 Miami -Dade (CER 1592) HVHZ Compliance NOA 12-0713.02 02/14/2013 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation, R14571, 2Q4 Exp. 08/08/2015 UL, U.C. (QUA9625) Quality Control Service Confirmation, MTS PLUS Exp. 07/01/2017 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlavrr►ents: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.2 _ Self-Adherin Underla ments: 4.2.1 �ip_olyoReflnlc s a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced film surface; meets ASTM D1970 and TAS 103. 4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with poly -film surface; meets TAS 103. 4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.4 PofystlekTU Pfs'fs a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103. 4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets ASTM.D1970 and TAS 103. 4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 170 g/m2 polyester fabric surface; meets TAS 103. 4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets. 4.2.8 Dual Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.2.9 Tile Pro' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface. 4.3 Mechanically Fastened and/or Bonded Underlayments• 4.3.1 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets. 4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets. S. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1115 Certificate of Authorization #9503 FL5259-R20 Revision 1S: 08/25/2014 Page 3 of 11 5.3 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.4 Allowable roof covers applied atop the underlayments are as follows: _ .. . ...,_.Wood Shakes &..:. Underlayment Asphaltshingles Nail -On Tile Foam -On Tile Metal Slate Shingles i Elastobase Yes Yes No Yes Yes Yes Elastobase P Yes Yes No Yes Yes Yes Polystick MTS Yes Yes No Yes Yes Yes Polystick MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P Yes Yes Yes No Yes Yes See 5.4.1 PotysUckSUPJus ` ;* Yes Yes Yes See 5.4.1 Yes Yes Polystick TU Max No Yes Yes Yes No No See 5.4.1 Dual Pro Yes Yes No Yes Yes Yes Tile Pro Yes Yes Yes Yes Yes Yes See 5.4.1 Elastoflex S6 G Yes Yes Yes No Yes Yes See 5.4.1 Elastoflex S6 G FR Yes Yes No No Yes Yes Polyflex G Yes Yes Yes No Yes Yes See 5.4.1 Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes No Yes Yes See 5.4.1 Mule -Hide SA-APP Cap Sheet or SA- Yes APP Cap Sheet(FRI Yes Yes See 5.4.1 No Yes Yes 5.4.1 "Foam -On Tile" is limited to use of the following Approved the adhesives unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. ✓ 3M— 2-Component Roof Tile Adhesive AH-160 (formerly Polyfoom PolyPro AH260): Polystick TU P, Polystick TU Plus, Polystick TU'Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro. ✓ 3M— Foam Roof Tile Adhesive RTA-1: Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) or Tile Pro ✓ Dow TileBond: Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro ✓ Convenience Products' Touch 'n Seal StormBond Roof Tile Adhesive: Polystick TU Plus, Polystick TU Max 5.5 Allowable substrates are noted below: Exterior Research and Design, I.I.C. Evaluation Report 1212060.02.09-1115 Certificate oJAuthorization #9503 FL5259-R20 Revision 15; 08/25/2014 Page 4 of 11 TP 5.5.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSS; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex S6 G or S6 G FR in hot asphalt to: D ASTM D41 primed structural concrete. Polyflex G or G FR torch -applied to: ASTM D41 primed structural concrete. 5.5.2 Bond -to -Insulation: Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: Y ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex 56 G or S6 G FR in hot asphalt to: D Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or G FR torch -applied to: D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulatio6/underiayment system in accordance with FM 4470, Appendix K orTAS 114, Appendix J. 5.5.3 Bond to Mechanically Attached Base Laver: Polystick, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual -Pro or Tile Pro self - adhered to: D ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex S6 G or S6 G FR in hot asphalt to: D ASTM D226, Type I or II felt; Elastobase; Elastobase,P or Mule -Hide Nail Base. Polyflex G or G FR torch -applied to: D Elastobase; Elastobase P or Mule -Hide Nail Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, refer to Section 5.5.4 herein and FRSA/TRI 07320/8-05 or RAS 120. 5.5.4 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI 07320 does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI 07320 and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609.1.5 for determination of design wind pressures. 5.5.4.1 Maximum Design Pressure = -90 osf. Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Underlayment: Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1115 Certificate ofAuthorization #9503 FL5259-R20 Revision 15: 08/25/2014 Page 5 of 11