HomeMy WebLinkAboutNew Prop Manual J Updated+� wrightsoft° Load Short Form
House
Air Calcs, LLC
Job: 1592
Date: 8/18/2021
By: Chris Bateman
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyrrie@aircalcs.com
For: Key Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
Htg Clg
Outside db (°F)
41
90
Inside db (°F)
70
75
Design TD (°F)
29
15
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/Ib)
2
57
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.9
kW
26975
Btuh
21
°F
1153
cfm
0.045
cfm/Btuh
0.70
in H2O
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
COOLING EQUIPMENT
Make Lennox
Trade LENNOX
Cond ML14XC1S036-230C*"
Coil CBA27UHE-036-230*++TDR
AHRI ref 204289057
Efficiency
13.0 EER, 16 SEER
Sensible cooling
24220
Btuh
Latent cooling
10380
Btuh
Total cooling
34600
Btuh
Actual airflow
1153
cfm
Air flow factor
0.051
cfim/Btuh
Static pressure
0.70
in H2O
Load sensible heat ratio
0.76
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
Laundry
36
423
859
19
44
Bed 2
136
2373
1995
108
103
Bath
42
58
91
3
5
Bath 2
55
811
672
37
35
Hall
30
0
0
0
0
Bed 3
149
3388
3221
154
166
Bed 4
157
2458
1542
112
79
Foyer GR
426
5154
4875
234
251
Kitchen DR
424
4590
5783
208
298
Master Bath
117
2065
884
94
45
WIC
20
401
158
18
8
R A--+—, D— A
Otis)
120-(]!1
012124
4 G7
Or)
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft, 2021-Nov-16 13:33:41
AM— „1,— , nawa.=om — Right-Sute®Urrversa12021 21.0.10 RSU29066 Page l
ACCP....ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
House
1801
25411
22411
1153
1153
Other equip loads
1769
939
Equip. @ 0.95 RSM
22277
Latent cooling
7225
TnTAI C
1 Ant
771 An
11 rI2
11 rI2
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsoft®
k,e—H,nawa.Co —, Right-Srite®Uriversa1202121.0.10RSU29066
ACCP....ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
N1104o►rimM- BAIQUI
Page 2
Building Analysis Job: 1592
+� wrightsoft° gnaDate: 8/18/2021
House By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyrrie@aircalcs.com
For: Key Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
Location:
Indoor:
Heating
Cooling
St Lucie Co Intl, FL, US
Indoor temperature (°F)
70
75
Elevation: 26 ft
Design TD (°F)
29
15
Latitude: 28°N
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (gr/Ib)
2.4
56.9
Dry bulb (T) 41
90
Infiltration:
Daily range (T) -
15 (L )
Method
Simplified
Wet bulb (T) -
77
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Component
Btuh/ft2
Btuh
% of load
Walls
3.1
4601
16.9
Glazing
17.4
4040
14.9
Doors
0
0
0
Ceilings
1.0
1785
6.6
Floors
3.2
5736
21.1
Infiltration
2.2
3186
11.7
Ducts
6062
22.3
Piping
0
0
Humidification
0
0
Ventilation
1769
6.5
Adjustments
0
Total
27180
1 100.0
Component
Btuh/112
Btuh
% of load
Walls
1.9
2835
12.1
Glazing
16.2
3769
16.1
Doors
0
0
0
Ceilings
1.5
2634
11.3
Floors
0
0
0
Infiltration
0.6
891
3.8
Ducts
6782
29.0
Ventilation
939
4.0
Internal gains
5500
23.6
Blower
0
0
Adjustments
0
Total
23351
100.0
Latent Cooling Load = 7225 Btuh
Overall U-value = 0.105 Btuh/ft2--°F
Data entries checked.
Glazi
u:1a•111
Floors
Vantilatinn
NPROM ."
Uucts
on
Gains
wrightsoft" 2021 -Nov-1 6 13:33:41
^^^-k-I-11 1—,1^P1r', Right-Sute®Urrversa1202121.0.10RSU29066 Pagel
ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
Component Constructions Job: 1592
+� wrightsoft CpCi
Date: 8/18/2021
House By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyrrie@aircalcs.com
For: Key Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
Location:
St Lucie Co Intl, FL, US
Elevation: 26 ft
Latitude: 28°N
Outdoor: Heating Cooling
Dry bulb (T) 41 90
Daily range (T) - 15 (L
Wet bulb (T) - 77
Wind speed (mph) 15.0 7.5
)
Indoor:
Indoor temperature (T)
Design TD (T)
Relative humidity (%)
Moisture difference (grAb)
Infiltration:
Method
Construction quality
Fireplaces
Heating
70
29
30
2.4
Simplified
Average
0
Cooling
75
15
50
56.9
Construction descriptions
Or
Area U-value
Insul R
Htg HTM
Loss Clg HTM Gain
ft' Btuh/ftUF
ft2-7/Btuh
Btuh/ft'
Btuh
Btuh/ft' Btuh
Walls
Blk Wall, Stucco Ext, R-4.1 Ext Bd inl, 8"Thk, 1/2" Gyp Bd Int Fnsh
n
251 0.109
5.1
3.15
791
2.02 506
e
371 0.109
5.1
3.15
1169
2.02 748
s
387 0.109
5.1
3.15
1220
2.02 780
w
212 0.109
5.1
3.15
668
2.02 427
all
1221 0.109
5.1
3.15
3848
2.02 2461
Partitions
Fnn Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"A", 16"
257 0.101
11.0
2.94
754
1.46 374
OC Stud
Windows
Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22);
n
47 0.620
0
18.0
841
11.7 550
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
n
40 0.580
0
16.8
676
8.03 323
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 4.7 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
s
5 0,580
0
16.8
79
13.5 63
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (2.17 ft window ht, 1 ft sep.); 6.8 ft head ht
Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24);
s
31 0.580
0
16.8
525
13.6 426
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht
W
47 0.580
0
16.8
787
28.1 1317
all
78 0.580
0
16.8
1312
22.3 1742
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
s
16 0.580
0
16.8
262
13.5 210
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 8 ft overhang (5.2 ft window ht, 1 ft sep.); 6.8 ft head ht
wrightsoft"'
2021-Nov-1613:33:41
--k=de-•,.ea«a-a. ,P=. Right-Sute®Urrversal202121.0.10RSU29066
ACCA
Pagel
ightsoft HVAC\7803 Fort Walton Ave PSL Prop.n p Calc= MJ8 Front Door faces: N
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.21); s
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 8 ft overhang (6.7 ft window ht, 1 ft sep.); 6.8 ft head ht
Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); w
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (2.2 ft window ht, 1 ft sep.); 6.8 ft head ht
Doors
(none)
Ceilings
Attic, Metal Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh
Floors
On Grade Depth, Tile Flr Fnsh
_ wrightsoft-
e
�Ch — = d k,,,.e a«a.a. o „_ . Right-Sritee Uriversal 2021 21.0.10 RSU29066
ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
40 0.650
0
18.8
758
14.0
563
7 0.580
0
16.8
111
28.1
186
1801
0.034
30.0
0.99
1785
1.46
2634
200
0.989
0
28.7
5736
0
0
2021-Nov-16 13:33:41
Page 2
+� wrightsoft° Project Summary
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyrrie@aircalcs.com
For: Keyy Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
Notes:
Weather: St Lucie Co Intl, FL, US
Winter Design Conditions
Outside db 41 °F
Inside db 70 °F
Design TD 29 °F
Heating Summary
Structure 19348 Btuh
Ducts 6062 Btuh
Central vent (56 cfm) 1769 Btuh
Outside air
Humidification
Piping
Equipment load
Infiltration
Method
Construction quality
Fireplaces
0 Btuh
0 Btuh
27180 Btuh
Simplified
Average
0
Heating Coolingg
Area (ft2)
1801
1801
Volume (ft3)
15786
15786
Air changes/hour
0.38
0.20
Equiv.AVF (cfm)
100
53
Heating Equipment
Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.9 kW
26975 Btuh
21 °F
1153 cfm
0.045 cfm/Btuh
0.70 in H2O
Job: 1592
Date: 8/18/2021
By: Chris Bateman
Summer Design Conditions
Outside db
90
°F
Inside db
75
°F
Design TD
15
°F
Daily range
L
Relative humidity
50
%
Moisture difference
57
gr/Ib
Sensible Cooling Equipment Load Sizing
Structure 15629 Btuh
Ducts 6782 Btuh
Central vent (56 cfm) 939 Btuh
Outside air
Blower 0 Btuh
Use manufacturer's data n
Rate/swin multiplier 0.95
Equipmen� sensible load 22277 Btuh
Latent Cooling Equipment Load Sizing
Structure 3033 Btuh
Ducts 2047 Btuh
Central vent (56 cfm) 2145 Btuh
Outside air
Equipment latent load 7225 Btuh
Equipment Total Load (Sen+Lat) 29502 Btuh
Req. total capacity at 0.70 SHR 2.7 ton
Cooling Equipment Summary
Make Lennox
Trade LENNOX
Cond ML14XC1S036-230C**
Coil CBA27UHE-036-230*++TDR
AHRI ref 204289057
Efficiency 13.0 EER, 16 SEER
Sensible cooling 24220
Btuh
Latent cooling 10380
Btuh
Total cooling 34600
Btuh
Actual airflow 1153
cfm
Air flow factor 0.051
cfim/Btuh
Static pressure 0.70
in H2O
Load sensible heat ratio 0.76
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wriQhtsoft- 2021-Nov-16 13:33:41
Right-Sute®Uriversal 202l 2l.O.10 RSU29066 Page 1
ACCA ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
House
Laundry
2
E)posed wal I
200.0 It
5.5 ft
3
Room height
8.8 ft
8.0 it heat/cool
4
Room dimensions
5.5 x 6.5 it
5
Room area
1800.8 fF
35.8 ft
Ty
Consh'ucton
U-value
Or
HTM
Area (ft)
Load
Area (ft)
Load
number
(Btuh/ft2--°F)
(Btuh/fl)
or perimeter (it)
(Btuh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
338
251
791
506
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
47
0
841
550
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
40
0
676
323
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
371
371
1169
748
0
0
0
0
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
479
387
1220
780
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
5
5
79
63
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
31
26
525
426
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
16
16
262
210
0
0
0
0
Impact, ClearLow-e
0.650
s
18.85
14.02
40
40
758
563
0
0
0
0
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
266
212
668
427
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
7
0
111
186
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
47
0
787
1317
0
0
0
0
P
Fmi Wall, 1/2" Gyp B
0.101
2.94
1.46
257
257
754
374
44
44
129
64
C
Attic, Metal Roof, R
0.034
0.99
1.46
1801
1801
1785
2634
36
36
35
52
F
On Grade Depth, Tile
0.989
28.68
0.00
1801
200
5736
0
36
6
158
0
6
c) AED excursion
131
-17
Envelope loss/gain
16162
9238
322
99
12
a) Infiltration
3186
891
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
5
1150
0
0
Appliances/other
4350
500
Subtotal (lines 6 to 13)
19348
15629
322
599
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
0
0
0
0
14
Subtotal
19348
15629
322
599
15
Dud loads
31%
43%
6062
6782
31%
43%1
101
260
FFTotal
room load
25411
22411
423
859
Airrequired(dm)
1153
1153
19
44
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 2021 21.0.10 RSU29066 Page 1
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Bed 2
Bath
2
E)posed wal I
24.0 It
0 It
3
Room height
8.0 It heat/000l
8.0 ft heat/000l
4
Room dimensions
1.0 x 135.8 It
7.0 x 6.0 It
5
Room area
135.8 fF
42.0 tt
Ty
Consh'ucton
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/R2--°F)
(Btuh/fl)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
0
0
0
0
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
0
0
0
0
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
0
0
0
0
0
0
0
0
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.650
s
18.85
14.02
0
0
0
0
0
0
0
0
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
84
68
216
138
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
16
0
262
439
0
0
0
0
P
Fmi Wall, 1/2" Gyp B
0.101
2.94
1.46
108
108
317
158
0
0
0
0
C
Attic, Metal Roof, R
0.034
0.99
1.46
136
136
135
199
42
42
42
61
F
On Grade Depth, Tile
0.989
28.68
0.00
136
24
688
0
42
0
0
0
6
c) AED excursion
151
-2
Envelope loss/gain
1618
1084
42
60
12
a) Infiltration
184
51
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
250
0
Subtotal (lines 6 to 13)
1802
1385
42
60
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
4
6
2
4
14
Subtotal
1807
1391
44
63
15
Dud loads
31%
43%
5661
604
31%
43%1
14
27
FFTotal
room load
2373
1995
58
91
Airrequired(dm)
108
103
3
5
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 2021 21.0.10 RSU29066 Page 2
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Bath 2
Hall
2
E)posed wal I
6.5 it
O ft
3
Room height
8.0 it heat/cool
8.0 ft heat/cool
4
Room dimensions
8.5 x 6.5 it
3.5 x 8.5 it
5
Room area
55.3 ft'
29.8 tt
Ty
Consh'ucton
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/R2--°F)
(Btuh/fl)
or perimeter (it)
(Btuh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
0
0
0
0
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
0
0
0
0
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
0
0
0
0
0
0
0
0
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.650
s
18.85
14.02
0
0
0
0
0
0
0
0
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
52
45
143
91
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
7
0
111
186
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
P
Fmi Wall, 1/2" Gyp B
0.101
2.94
1.46
0
0
0
0
0
0
0
0
C
Attic, Metal Roof, R
0.034
0.99
1.46
55
55
55
81
30
30
29
44
F
On Grade Depth, Tile
0.989
28.68
0.00
55
7
186
0
30
0
0
0
6
c) AED excursion
68
-1
Envelope loss/gain
495
426
29
42
12
a) Infiltration
114
32
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
609
457
29
42
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
8
11
-29
-42
14
Subtotal
617
469
0
0
15
Dud loads
31%
43%1
1931
203
31%
43%1
0
0
qT.0,
tal room load
811
672
0
0
quired (dm)
37
35
0
0
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 2021 21.0.10 RSU29066 Page 3
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Bed 3
Bed 4
2
E)posed wal I
25.0 ft
21.0 It
3
Room height
8.0 It heat/000l
8.0 ft heat/000l
4
Room dimensions
1.0 x 149.0 It
1.0 x 157.0 It
5
Room area
149.0 fF
157.0 fF
Ty
Consh'ucton
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/R2--°F)
(Btuh/fl)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
0
0
0
0
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
0
0
0
0
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
0
0
0
0
64
64
202
129
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
96
80
253
162
104
88
279
178
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
16
13
262
213
16
13
262
213
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.650
s
18.85
14.02
0
0
0
0
0
0
0
0
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
104
73
229
147
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
31
0
525
878
0
0
0
0
P
Fmi Wall, 1/2" Gyp B
0.101
2.94
1.46
0
0
0
0
0
0
0
0
C
Attic, Metal Roof, R
0.034
0.99
1.46
149
149
148
218
157
157
156
230
F
On Grade Depth, Tile
0.989
28.68
0.00
149
25
717
0
157
21
602
0
6
c) AED excursion
247
-31
Envelope loss/gain
2135
1864
1501
719
12
a) Infiltration
439
123
368
103
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
250
250
Subtotal (lines 6 to 13)
2573
2236
1869
1072
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
7
10
2
4
14
Subtotal
2580
2246
1871
1075
15
Dud loads
31%
43%
8081
975
31%
43%1
586
467
FFTotal
room load
3388
3221
2458
1542
Airrequired(dm)
154
166
112
79
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 20212 1.0.10 RSU29066 Page 4
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Foyer GR
Kitchen DR
2
E)posed wal I
34.5 ft
28.0 ft
3
Room height
9.5 ft heat/000l
9.5 ft heat/000l
4
Room dimensions
1.0 x 426.3 ft
1.0 x 424.3 ft
5
Room area
426.3 fF
424.3 ft'
Ty
Conshvcton
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/R2--°F)
(Btuh/fl)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
223
152
478
306
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
31
0
561
366
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
40
0
676
323
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
0
0
0
0
71
71
224
144
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
0
0
0
0
195
139
438
280
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
16
16
262
210
Impact, ClearLow-e
0.650
s
18.85
14.02
0
0
0
0
40
40
758
563
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
P
Fmi Wall, 1/2" Gyp B
0.101
2.94
1.46
105
105
307
152
0
0
0
0
C
Attic, Metal Roof, R
0.034
0.99
1.46
426
426
423
624
424
424
421
621
F
On Grade Depth, Tile
0.989
28.68
0.00
426
35
989
0
424
28
803
0
6
c) AED excursion
-98
-116
Envelope loss/gain
3435
1673
2906
1702
12
a) Infiltration
489
137
583
163
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
3
690
2
460
Appliances/other
900
1700
Subtotal (lines 6 to 13)
3924
3400
3489
4025
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
0
0
6
8
14
Subtotal
3924
3400
3495
4033
15
Dud loads
31%
43%
12301
1475
31%
43%1
1095
1750
FFTotal
room load
5154
4875
4590
5783
Airrequired(dm)
234
251
208
298
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 20212 1.0.10 RSU29066 Page 5
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Master Bath
WIC
2
E)q)osed wall
19.5 it
4.0 ft
3
Room height
8.0 it heat/000l
8.0 it heat/000l
4
Room dimensions
1.0 x 116.5 it
5.0 x 4.0 it
5
Room area
116.5 fF
20.0 ft'
Ty
Consh'ucton
U-value
Or
HTM
Area (ft)
Load
Area (ft)
Load
number
(Btuh/ft2--°F)
(Btuh/fl)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Blk Wall, Stucco Ext
0.109
n
3.15
2.02
0
0
0
0
0
0
0
0
T-jImpact,
Clear Lowe
0.620
n
17.98
11.74
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
n
16.82
8.03
0
0
0
0
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
a
3.15
2.02
72
72
227
145
32
32
101
64
11
Blk Wall, Stucco Ext
0.109
s
3.15
2.02
84
79
250
160
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
5
5
79
63
0
0
0
0
G
Impaa Clear Low-e
0.580
s
16.82
13.64
0
0
0
0
0
0
0
0
Impaa Clear Low-e
0.580
s
16.82
13.48
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.650
s
18.85
14.02
0
0
0
0
0
0
0
0
Blk Wall, Stucco Ext
0.109
w
3.15
2.02
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.580
w
16.82
28.13
0
0
0
0
0
0
0
0
P
Frm Wall, 1/2" Gyp B
0.101
2.94
1.46
0
0
0
0
0
0
0
0
C
Attic, Metal Roof, R
0.034
0.99
1.46
117
117
115
170
20
20
20
29
F
On Grade Depth, Tile
0.989
28.68
0.00
117
20
559
0
20
4
115
0
6
c) AED excursion
-18
-3
Envelope loss/gain
1230
521
235
91
12
a) Infiltration
342
96
70
20
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
1573
616
306
110
Less extemalload
0
0
0
0
Less transfer
0
0
0
0
Redishibution
0
0
0
0
14
Subtotal
1573
616
306
110
15
Dud loads
31%
43%
4931
268
31%
43%1
96
48
FFTotal
room load
2065
884
401
158
Airrequired(dm)
94
45
18
8
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 2021 21.0.10 RSU29066 Page 6
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+ wrightsoft" Right-J® Worksheet Job: 1592
House Date: 8/18/2021
By: Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
1
Room name
Master Bed
2
E)posed wall
32.0 it
3
Room height
8.5 it heat/000l
4
Room dimensions
13.5 x 15.5 it
5
Room area
209.3 fF
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area
Load
number
(BtuhV-°F)
(Btuh/fF)
or perimeter (ft)
(Btuh)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
Wall, Stucco Ext
0.109
n
3.15
2.02
115
99
312
200
1�:Blk
G
Impact, Clear Low-e
0.620
n
17.98
11.74
16
0
280
183
G
Impact, Clear Low-e
0.580
n
16.82
8.03
0
0
0
0
W
Blk Wall, Stucco Ext
0.109
e
3.15
2.02
132
132
415
266
11
W
Blk Wall, Stucco Ext
Impact, Clear Low-e
0.109
0.580
s
s
3.15
16.82
2.02
13.48
0
0
0
0
0
0
0
0
G
Impact, Clear Lowe
0.580
s
16.82
13.64
0
0
0
0
G
Impact, Clear Lowe
0.580
s
16.82
13.48
0
0
0
0
Impact, Clear Lowe
0.650
s
18.85
14.02
0
0
0
0
W
Blk Wall, Stucco 6d
0.109
w
3.15
2.02
26
26
80
51
Impact, Clear Lowe
0.580
w
16.82
28.13
0
0
0
0
Impact, Clear Lowe
Frm Wall, 1/2" Gyp B
0.580
0.101
w
16.82
2.94
28.13
1.46
0
0
0
0
0
0
0
0
P
C
Attic, Metal Roof, R
0.034
0.99
1.46
209
209
207
306
F
On Grade Depth, Tile
0.989
28.68
0.00
209
32
918
0
6
c) AED excursion
-47
Envelope loss/gain
2214
959
12
a) Infiltration
596
167
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
0
0
Appliances/other
500
Subtotal (lines 6 to 13)
2810
1626
Less e)demal load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
2810
1626
15
Dud loads
31%
43%
8801
706
FFTotal
room load
3690
2331
Air required (cfm)
167
120
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed
rigl- tsoft- 2021-Nov-1613:33:41
�� ..i htsoft HVAC\78 Right -Suite@ Universal 2021 21.0.10 RSU29066 Page 7
g 03FortWaltonAvePSLProp.rp Calc=MJ8 Front Door faces: N
+� wrightsoft° Duct System Summary
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
For: Key Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.70
in H2O
0
in H2O
0.70
in H2O
0.490 / 0.210
in H2O
0.281
in/100ft
1153
cfm
249
Job: 1592
Date: 8/18/2021
By: Chris Bateman
Cooling
0.70
in H2O
0
in H2O
0.70
in H2O
0.490 / 0.210
in H2O
0.281
in/100ft
1153
cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bat,
c 91
3
6
0.453
4.0
Ox0
VIFx
13.1
95.0
st1
Bath
h 811
44
42
0.336
4.0
Ox0
VIFx
25.7
120.0
st3
Bed 2
h 2373
129
123
0.452
6.0
Ox 0
VI Fx
13.3
95.0
st1
Bed 3
c 3221
185
199
0.328
7.0
Ox 0
VI Fx
29.2
120.0
st3
Bed 4
h 2458
134
95
0.339
6.0
Ox 0
VI Fx
24.2
120.0
st3
FoyerGR
c 2438
140
151
0.382
6.0
Ox0
VIFx
33.2
95.0
st2
Foyer GR-A
c 2438
140
151
0.382
6.0
Ox0
VIFx
33.1
95.0
st2
Kitchen DR -A
c 2891
125
179
0.382
7.0
Ox 0
VI Fx
33.0
95.0
st2
Kitchen DR-B
c 2891
125
179
0.383
7.0
Ox 0
VI Fx
32.7
95.0
st2
Laundry
c 859
23
53
0.455
4.0
Ox0
VIFx
12.6
95.0
st1
Master Bath
h 2065
112
55
0.284
6.0
Ox 0
VI Fx
52.2
120.0
st4
Master Bed
h 1845
100
72
0.288
6.0
Ox 0
VI Fx
50.2
120.0
st4
Master Bed -A
h 1845
100
72
0.297
6.0
Ox 0
VI Fx
44.8
120.0
St4
WIC
h 401
22
10
0.281
4.0
Ox 0
VI Fx
49.0
125.0
St4
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st3
PeakAVF
363
336
0.328
821
9.0
0 x 0
VinlFlx
st1
st1
PeakAVF
518
518
0.328
660
12.0
0 x 0
VinlFlx
st2
PeakAVF
866
866
0.281
811
14.0
0 x 0
VinlFlx
st4
PeakAVF
335
208
0.281
759
9.0
0 x 0
VinIFIX
st2
wrightsoft®
A� k,I,-1_,.-yI-p-, Right-Sute®Urrversa1202121.0.10RSU29066
ACCP....ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N
2021-Nov-16 13:33:41
Page 1
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FIR
(fpm)
(in)
(in)
Opening (in)
Matl
Trunk
rb5
Ox0
134
95
74.8
0.281
501
7.0
Ox 0
VIFx
rt1
rb6
Ox0
185
199
66.7
0.315
570
8.0
Ox 0
VIFx
rt1
rb7
Ox0
129
123
62.8
0.335
484
7.0
Ox 0
VIFx
rt1
rb1
Ox0
714
813
58.0
0.363
582
16.0
Ox 0
VIFx
rt1
rb8
Ox0
223
154
0
0
0
0
Ox 0
VIFx
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
rt1
PeakAVF
1161
1230
0.281
696
1&0
0 x 0
VInIFIX
Bolditalic values have been manually overridden
wrightsoft®
A k,1,- _ -.-p,, Right-Sute®Urrversa1202121.0.10RSU29066
ACCP....ightsoft HVAC\7803 Fort Walton Ave PSL Prop.n p Calc= MJ8 Front Door faces: N
2021-Nov-16 13:33:41
Page 2
+� wrightsoft° Manual S Compliance Report
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vickilyme@aircalcs.com
For: Key Largo Spec Home, NisAirAir Conditioning
7803 Fort Walton Ave, Fort Pierce, FL 34951
Design Conditions
Job: 1592
Date: 8/18/2021
By: Chris Bateman
Outdoor design DB:
90.4°F
Sensible gain:
23351
Btuh Entering coil DB: 76.9°F
Outdoor design WB:
77.4°F
Latent gain:
7225
Btuh Entering coil WB: 64.0°F
Indoor design DB:
75.0°F
Total gain:
30576
Btuh
Indoor RH:
50%
Estimated airflow:
1153
cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype:
SplitAC
Manufacturer:
Lennox
Model: ML14XC1S036-230C**+CBA27UHE-036-230*++TDR
Actual airflow:
1153
cfm
Sensible capacity:
24220
Btuh
104% of load
Latent capacity:
10380
Btuh
144% of load
Total capacity:
34600
Btuh
113% of load SHR:
70%
Heating Equipment
Design Conditions
Outdoor design DB:
41.0°F
Heat loss:
27180
Btuh Entering coil DB: 68.1°F
Indoor design DB:
70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Elecstrip
Manufacturer: Model:
Actual airflow: 1153 ch
Output capacity: 7.9 kW 99% of load
Meets all requirements ofACCA Manual S.
Temp. rise: 50 °F
wrightsoft, 2021-Nov-16 13:33:41
IIT—Io-„1,,, ,,,.,—,�, Right-Sute®Urrversa1202121.0.10RSU29066 Pagel
ACCk ightsoft HVAC\7803 Fort Walton Ave PSL Prop.rup Calc= MJ8 Front Door faces: N