HomeMy WebLinkAboutSITE PLAN APPROVED FOR CONSTRUCTION T
SITE PLAN NOTES 0 PENSACOLA RD.
*FINISHED FLOOR ELEVATION TO BE SET BY SAINT LUCIE COUNTY HEALTH DEPARTMENT. FINISHED FLFO@WGimSt. Lucie County I ~
HEREON IS AN AVERAGE OF EXISTING ADJACENT FINISHED FLOOR ELEVATIONS. W -� Z T` rn
PUBLIC UTILITIES ARE NOT AVAILABLE Environmental Health 0 °' 00 z co
Site Plan Approved for Construction :2FORT WALTON AVE. C) 2
Ld
Supersedes All Previous Site Plans for o w a _j W E
— — _ — _0STQ 65 F,01&0 & Ve IL# y o LLi N S o
BENCHMARK Date: 1 Lu z- GRAPHIC SCAz,E SIT ELAND AVE U N-�;
� a
FND MAG/D(LB6018) I 30 0 i5 3D Q CD O O
R viewer: b a _j '7 ¢F
EL:20.36' Cd LV N 3 Q
FND MAG/D O� �� ,pro ( IN �r ) CD U) h H LL
(NO ID) O O O 1. inch = 30 (L ST. LUCIE COUNTY, FLORIDA Q
�� �o �� (BEARING BASIS) n o ar
F O R T W_ L T 0 AVE. o. _ s�_9°47°� w e t� Z VICINITY MAP o
('70.00' PUBLIC RIGHT-0 •-WAY) oo �,� FND PK/ �,y 429.00'(P)� - —�y NO SCALE > o-
d1 O• (NO ID) o. bC1
a (20' WIDE ASPHAL 7N�'8904711
r SYMBOL &ABBREVIATION LEGEND. CD
p� 12"X18" CMP I ASPH ASPHALT FINISHED FLOOR TOPOGRAPHIC DATA
„ FXN ' INV:18.96 . F.F.E. ELEVATION X 0.0SOFT SURFACE)
12%18 CMP �� X BENCHMARK (BM) FND FOUND
_ INV:18.35' YYY X 0.00 TOPOGRAPHIC DATA 0
O 9 0.00 (P)(C) O� (C) CALCULATED SQ FT. SQUARE FEET (HARD SURFACE) W Q
r — — `ti— — — INV INVERT F-
3 FND 5/8" IR �___________ __� FND 5/8" IR Ck CENTERLINE IF IRON PIPE ® MONITORING WELL y J a
PROP CLF CHAIN LINK FENCE WF WOOD FENCE g
z (NO ID) I (NO ID) IR IRON ROD
c.+ 16' 1 Gprlc CONCRETE p z
0.30' S O CONC C4 1 0.22 W CORRUGATED METAL IR/C IRON ROD AND CAP COL) WOOD POWER POLE w O
DRIVE PROPOSED SEPTIC CMP PIPE MAG/D MAC; NAIL MAG p;
BRAND NAIL w
Cn 667 SQ. FT. DRAINI�IELD (D) DEED w z
I NORTH AMERICAN W
Z 21 56' I U ) 1095 SQ. FT. D.B. DEED BOOK NAVD86 VERTICAL DATUM OF
O -_j 10,1 T`DL71 ---- 2 95' UNOBSTRUCTED AREA EL./ELEV. OFF CIAL RECORDS �Uzl
0 � Ca1 . �' , (M) FIELD MEASURED O.R.B. BOOK
SEPTIC `'' W r _J LOT 17
22.17' oX��. U! L�J (OCCUPIED) LEGAL DESCRIPTION z
� / LOT 19 � SEPTIC
C7 �„ FIFE:23.10'
u., � (OCCUPIED) AC CD LOT 18 C LOT 18, BLOCK 62, LAKEWOOD PARK, UNIT NO 6, ACCORDING TO THE PLAT OF THEREOF AS RECORDED IN PLAT BOOK w
co DO 9 " 11, PAGE 7, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
FEE:23.77' PAD cn PROPOSED �0 O U z
o RESIDENCE Iv CONTAINING 0.27 ACRES, MORE OR LESS, Z Q
FFE:23.44* 10,17 12.97' C7 6' VINYL FENCE p
v SURVEYORS NOTES AND REPORT: Z � z N a
7 6' WOOD FENCE , N / CORNER 0.84' E a O
ZO.SO ► 1. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND COti 1.8' W(TYP.) O (� MAPPER. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS, BY OTHER THAN THE SIGNING SURVEYOR IS vJ a E_
}- U a- w o
O' o PORCH PROHIBITED, WITHOUT CONSENT OF THE SIGNING SURVEYOR. N
Xr 24.83' 0 20.50 A
7. THE LAST DATE OF FIELD WORK WAS OCTOBER 11, 2021, z-P p 3. CURRENT DESCRIPTIONS SHOWN HEREON PROVIDED BY THE CLIENT AND/OR THEIR AGENTS. LANDS SHOWN HEREON T- _ �- 0 w O WERE NOT ABSTRACTED BY THIS OFFICE FOR RIGHT-OF-WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS X O
PROP I � OF RECORD. SUCH INFORMATION SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE it Q U
WATER �' VERIFICATION. ¢ _ _J _1
5 O 4. UNDERGROUND UTILITIES, UTILITY SERVICES, FOUNDATIONS AND IMPROVEMENTS WERE NOT LOCATED AS A PART OF Z
LINE THIS SURVEY. r" CL coo a
P 5. BEARINGS SHOWN HERON ARE BASED UPON THE PLAT OF RECORD, AND ARE RELATIVE TO THE LINE LABELED Y_j
40 }� HERON AS (BEARING BASIS), DISTANCES ARE IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF. Q O 1� V
B 0 C K 6 2 I �° ,`G SET 5/8" IRG 6. ELEVATIONS SHOWN HEREON ARE BASED UPON THE NORTH AMERICAN VERTICAL DATUM OF 198E (NAVD'88). THE m 0 OJ 1 j
PROP Le I PRIMARY BENCHMARK IS CITY OF PORT ST. LUCIE BENCHMARK DENOTED AS "TONIC" HAVING A PUBLISHED a m
,o I (LB8098) ELEVATION OF 19.68 FEET NAVD 1988,
0 DWELL 1-- �� 7. THIS SITE WAS SURVEYED UTILIZING TRIMBLE/SPRECTRA HARDWARE TOGETHER WITH SPECTRA SURVEY PRO O �
T FND 1 2" IP ` — XI ' 6' VINYL FENCE — REALTIME PROCESSING AND WAS BASED ON TRIMBLE'S '*VRS NOW" NETWORK AND/OR THE FLORIDA PERMANENT F-
/ 4, ��j' REFERENCE NETWORK (FPRN). THE PROCEDURES AND NETWORK DESIGN MEETS THE GEODETIC ACCURACY JO
_ (NO ID) �O' X 2.38' E — STANDARDS AND SPECIFICATIONS FOR USING CPS RELATED POSITIONING AS SET FORTH BY THE FEDERAL GEODETIC
» CONTROL COMMITTEE IN THE MOST CURRENT PUBLICATION FOij 3RD ORDEER CLASS ONE FOR HORIZONTAL CONTROL
S 9947 11 W(C) 90.00 {P){C) 19•91 SURVEYS. „L',l1= ts�.,, DRAWN BY:FS
0.36' OHW ,OKW �9 8. IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMB LS SH0(�r{' V 1-? EN EXAGGERATED TO MORE CHECKED BY:MTO
N - — CLEARLY ILLUSTRATE THE RELATIONSHIP BETWEEN PHYSIC�1 h1P QVEIMIWNI�� LOT LINES. THE DIMENSIONS CREW:IP
�. .��' �°�' 4 CHAIN SHOWN SMALL CONTROL THE LOCATION, OF THE IMPRO NTS C SCALE[l OSITIONS.
0 4 CHAIN 179 FENCE LOT 10 Ott b' I `� DATE:10/1112D21
�., (4�j 9, THIS PROPERTY IDES IN FLOOR-ZONE "X,° ACCORDINC�Us Fi I I_ D SURgNCE IrYATE MAP 12111C0070J
FENCE LOT 8 LOT 9 g' S (OCCUPIED) EFFECTIVE ON FEBRUARY 16, 2021. u'° �jC` \ PROJECT,21AB8
co 9' S (OCCUPIED) (VACANT) FFE:21.20' 10, REVISIONS SHOWN HER DO NO RES A'"FIE UPDATE" UNLESS4THERWISE NOTED.
co FFE:22.25' I
SEPTIC SEPTIC �F A
N BEYOND 75' BEYOND 75' �� � 10� a y
O
N5 MI A T. 0 PROFESSIONALUR SVI~Y0 . 'A u MAPPER C ATURE D E:
- , //� 51 SHEET
FLORIDA REGISTRATION #5556 'Ot) �t41 IQ�``tiq 4F 2
CROSS SECTION Al
SITE PLAN NOTES r
GRAPHIC SCALE N
*FINISHED FLOOR ELEVATION TO BE SET BY SAINT LUCIE COUNTY HEALTH DEPARTMENT, FINISHED FLOOR DEPICTED 30 0 15 30 1_"
HEREON IS AN AVERAGE OF EXISTING ADJACENT FINISHED FLOOR ELEVATIONS. Z h
PROPERTY LINE 00 z m
( m FEED ) 20.2' (EXISTING)
19.8' (EXISTING) cn O z
1 inch = 90 it 19.00' (PROPOSED) 22.94 (PROPOSED) FINISHED d' F O
� M
O ELEV. 23.44' LL 'V' 8 = o
BENCHMARK y o m - PROPOSED SLAB Y W N
FIND MAG/D(LB6018) Tl L - Q ° F°w o
EL: 20.36' ro W J N 6 Q
FIND MAG/D O° Nb ^6 ��y o SEPTIC DRAINFlELD 0 to ti LL
O Om O' N z 19.8' (EXISTING) J F, U w
(BEARING BASIS) ('� 21,14' (PROPOSED) J ww
FORT W_ L T 0 °�° A V E . °° S89 t7' 11 " w C J� , t� 0 am
( 70 . 0W PUBLIC RIGHT- 0 -WAY) moo °^ FNDNOK D) °ryy 429 . 00' ( P) ( C) V y CROSS SECT/ON B'td N a m J
( 20 ' WIDE ASPHAL 1, t-( o C4 LL
(wTx cn C r
12"x18" CMP I
12"x18" CMP II�� 0 0- �� x �� - �� 0� INV: 18, 9�6' 20.9' (EXISTING) m
F X^ NATURAL GRADE 22.94 (PROPOSED) FINISHED p
INV: 18. 35' N89 *47 11 " E ( ) 90 . 00 ' ( P ) ( C) r' FLOOR
O' PROPERTY EIEV= 23.44' w
L — _ LINE Z
v PROP — � _ _I PROPOSED SLAB N W
Z w 163 j - �i ° ez
0) K
a o CONC rn � ' K -
I DRIVE w II w >
Z o i l (n z w
z 21 ,56' _____ _ j O CENTERLINE SWALE Z
O p 20,9' (EXISTING) W
LE 12. 95' LOT 17 21.34' (PROPOSED)
x (OCCUPIED) p
LOT 19 a� I FFE: 23. 10' CROSS SECTION 'C' �'
° (OCCUPIED) AC LOT 18 O W F
FIFE: PAD PROPOSED 20• m � U Z
RESIDENCE ? Yo
T FFE: 23. 44* 12. 9 n zos' (EXISTING) Z Z W
m C I 22.94' (PROPOSED) FINISHEDQ (n W p, 0
NATURAL GRADE FLOOR ~ o LL
a CPO I � PROPERTY ELEV.= 23.4AV C) LLI Or
3 _ h x LINE PROPOSED SLAB 11.1 �' � 'Z
LU
21 . 51 ' do Ip _ �- co
710ENTERLINE
o j r� � 0E— ntO �
r
m aQ O O Y
B L 0 C KI B 2\ ak O CENTERLINE SWALE O O rPROP Le ` I 20.0' (EXISTING) LL m® \ 21,34' (PROPOSED)WELL5� O
LL °43 ^�N _ _ ® CROSS SECTION D' ~ o
- - - - _ S88904711 C) 90SOKW00 ' ( F ) ( C )% �9' 9 ' DRAWN CHECKED BY:
o ^O' 20.4' (EXISTING) CREW: IF
�q 22.94' (PROPOSED) DATE: 10/11/2021
LOT 10 ® FLOORED PROJECT; 21-488
LOT 8 O LOT 9 (OCCUPIED) PROPERTY ELEV. 23.44'
o. (OCCUPIED) (VACANT) FFE: 21 , 20' UNE
FFE: 22. 25' NATURAL GRADE 10.89 PROPOSED SLAB
n- -
N
CENTERLINE SWALE SHEET
J 20.1 ' (EXISTING) ^ O F ^
w_ 21.5' (PROPOSED) L L
rJ