Loading...
HomeMy WebLinkAboutNOA - ASPHALT ROOF SHINGLES NEW I etc. Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT GAF Evaluation Report 01506.01.08-1130 1 Campus Drive FI-10124-1128 Parsippany,NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 30:09/22/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition(2020)Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/11905.2.6.1 CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: "'": 4• 'tip Robert J.M.Nieminen P.E. =��.F,� °s*{,•, The facsimile seal appearing was authorized by Robert ^=»�5c9 •` Nieminen,P.E.on 09122/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 „;�`.�` { electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02018 NEW ETC,LLC MEMO I etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles,as produced by GAF,have demonstrated compliance with the following sections of the 71h Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 1507.2.4,R905.2.3 Material standard ASTM D1970 2015 1507.2.5,R905.2A Material standard ASTM D3462 2010 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2019 1507.2.7.1,R905.2.6.1 Wind Resistance TAS 107 2020 ;t•, PRI(TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI(TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) ASTM D1970(QuickStart) GAF-340-02-01 03/13/2012 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI(TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI(TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI(TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI(TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 OINK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL(TST 1740) ASTM D3462 OINK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 OGCA31611 04/04/2007 NEMO ETC,LLC Evaluation Report 01506.01.08-1130 Certificate ofAothorizotion#32455 7-EDITION(2020)FBC NON-HVH2 EVALUATION FL30124-R28 GAF Asphalt Roof Shingles Revision 30:09/21/2020 Page 2 of 8 (ONEMOletc. Entity `Examination Reference Date UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL,LLC.(TST 9628) ASTM D3161 4788698165 03/24/2008 UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA35554 03/05/2010 UL(TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010 UL(TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 ` 10/22/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,I.I.C.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,I.I.C.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,I.I.C.(TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016 UL,LLC.(TST 9628) ASTM D3161 4788669132 12/13/2018 UL,LLC.(TST 9628) ASTM D3161 4788891098 02/14/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4788932264 08/16/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4789115488 08/16/2019 UL,LLC.(TST 9628) ASTM D3161 4788959558 10/17/2019 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786508528 11/01/2019 UL,LLC.(TST 9628) ASTM D3161 4789132672 11/27/2019 UL,I.I.C.(QUA 9625) Quality Control Service Confirmation 10/18/2018 UL,LLC.(QUA 9625) Quality Control Florida BCIS Current ram' Yve _ fr _ r _w..'T�BLE15jA1T5HlNGLEOlV104VENTS` ' `""-Type ; `" -P'Fodu�"`"�' �bescr)ptwn �fVlal:erial Plant�`sf Pro-Start®Starter Strip Shingles (fka,Pro-Start"Eave/Rake Starter starter strips for asphalt roof shingles ASTM D3462 CA-S,IN-MV,TX-D Accessory Strip Shingles) Starter mineral-surfaced,fiberglass-reinforced,self- Strips QuickStart°Peel&Stick Starter adhering SBS modified bitumen starter strip, Roll nominal 9-inch x 33 ft roll,for use with ASTM D1970 CA-S,IN-MV asphalt shingles with exposure of 6-inch or less NEMO ETC,LLC Evaluation Report 01506.01.08-R30 Certificate of Authorization k32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10124-1128 GAF Asphalt Roof Shingles Revision 30:09/21/2020 Page 3 of 8 NNEMOjetc. `'�' � 4 TgBLE`1 ASPHALT55HINGLE COMP4NENTS�, r " � �„.�, � �. .t ,n.. Matertai Type Product Description I?lant(s) ' andard '.:. color-coordinated starter strips for use with StarterMatch®Starter Strip Grand Canyon®and Grand Sequoia®series Shingles asphalt shingles. StarterMatch are installed ASTM D3462 CA-F Accessory as the second starter for Grand Canyon and Starter Grand Sequoia'series installations Strips WeatherBlocker'"Premium Starter Strip Shingles(fka, starter strips for asphalt roof shingles ASTM D3462 IN-MV WeatherBlocker'"Premium Eave/Rake Starter Strip Shingles) Marquis WeatherMax® IN-MV Royal Sovereign® fiberglass reinforced 3-tab asphalt roof ASTM D3462 AL,CA-F,FL,GA,IN- shingles MV,PA,TX-I) Sentinel® GA,IN-MV,TX-D Camelot®II IN-MV Fortitude'" PA Glenwood' IN-MV Grand Canyon® CA-F,IN-MV Grand Sequoia® CA-F,IN-MV Grand Sequoia°IR CA-F,IN-MV Grand Sequola°ArmorShield° CA-F Grand Sequoia®AS CA-F Timberline®American Harvest° AL,CA-F,IN-MC,PA Timberline®AH AL,CA-F,IN-MC,PA Timberline®ArmorShield®II TX-E Timberline®AS II TX-E Asphalt Timberline®Cool Series CA-F Shingles Timberline®CS fiberglass reinforced,laminated asphalt CA-F roof shingles ASTM D3462 AL,CA-S,FL,IN-MC, Timberline®HD MD,MN,PA,TX-D,TX- E AL,CA-F,CA-S,FL,IN- Timberiine®HDZ'" MC,MD,PA,TX-D,TX- E Timberline®Natural Shadow® AL,CA-S,IN-MC,MD, MN,PA,TX-D,TX-E Timberlinem NS AL,CA-S,IN-MC,MD, M N,PA,TX-D,TX-E Timberline®Ultra HD AL,CA-S,IN-MC,PA, TX-E Timberline®UHD AL,CA-S,IN-MC,PA, TX-E Woodland® IN-MV Slateline" fiberglass reinforced 5-tab asphalt roof ASTM D3462 IN-MV shingle Seal-A-Ridge®ArmorShield® AL Hip& Seal-A-Ridge°AS AL Ridge Seal-A-Ridge®Ridge Cap Shingles fiberglass reinforced,hip and ridge ASTM D3462 AL Shingles Timbertex®Premium Ridge Cap asphalt roof shingles Shingles IN-MV NEMO ETC,LLC Evaluation Report 01506.01.08-1130 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10124-1128 GAF Asphalt Roof Shingles Revision 30:09/21/2020 Page 4 of 8 ONEMOletc. IV 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications ��;� � TAB�E�LA'WIND-CLASSIFICATIONS„ASPHAtiLSHINGLES ,� °���� Marquis WeatherMax" ASTM D3161(F)&ASTM D7158(H) Royal Sovereign" ASTM D3161(F)&ASTM D7158(H) Sentinel® ASTM D3161(F)&ASTM D7158(H) Camelot®II ASTM D3161(F)&ASTM D7158(H) Fortitude— ASTM D3161(F)&ASTM.D7158(H) Glenwood"' ASTM D3161(F)&ASTM D7158(H) Grand Canyon® ASTM D3161(F)&ASTM D7158(H) Grand Sequoia" ASTM D3161(F)&ASTM D7158(H) Grand Sequoia°IR ASTM D3161(F)&ASTM D7158(H) Grand Sequoia"ArmorShield" ASTM D3161(F)&ASTM D7158(H) Grand Sequoia"AS ASTM D3161(F)&ASTM D7158(H) Timberline®American Harvest® ASTM D3161(F)&ASTM D7158(H) Timberline"AH ASTM D3161(F)&ASTM D7158(H) Timberline"ArmorShield®II ASTM D3161(F)&ASTM D7158(H) Timberline®AS II ASTM D3161(F)&ASTM D7158(H) Timberline®Cool Series ASTM D3161(F)&ASTM D7158(H) Timberline"CS ASTM D3161(F)&ASTM D7158(H) Timberline"HD ASTM D3161(F)&ASTM D7158(H) Timberline"HDZ- ASTM D3161(F)&ASTM D7158(H) Timberline"Natural Shadow® ASTM D3161(F)&ASTM D7158(H) Timberline".NS ASTM.D3161(F)&ASTM.D7158(H) Timberline"Ultra HD ASTM D3161(F)&ASTM D7158(H) Timberline"UHD ASTM D3161(F)&ASTM D7158(H) Woodland" ASTM D3161(F)&ASTM D7158(H) Slateline"" ASTM D3161(F)&ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Ca Iculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC,LLC Evaluation Report 01S06.01.08-R30 Certificate of Authorization t132455 71"EDITION(2020)FBC NON-HVHZ EVALUATION FL10124-R28 GAF Asphalt Roof Shingles Revision 30:09/22/2020 Page 5 of 8 - ONEMOletc. ,, K TABLE 2B WfreDinsslFic�►not3s;STARTER 57RfP�5/1Nt)HIP RIDGE Type::r;::; ' ; ::,::.:.:.:::::.";:i?; :::_. `>:::: Qrodud.'.";` : :;':•:.':.`:: '.:.` ;: :'>? FBC Table_1507.2.7.1orR905.2.6:1 Pro-Start"Starter Strip Shingles(fka,Pro-Start®Eave/Rake ASTM D3161,Class F Starter Strips Starter Strip Shingles) WeatherBlockerTM Premium Starter Strip Shingles(fka, ASTM D3161,Class F WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles) Seal-A-Ridge®ArmorShield® ASTM D3161,Class F(sealant required,See Section 6) Hip&Ridge Seal-A-Ridge®AS ASTM D3161,Class F(sealant Shingles required,See Section 6) Seal-A-Ridge®Ridge Cap Shingles ASTM D3161,Class F Timbertex®Premium Ridge Cap Shingles ASTM D3161,Class F(sealant required,See Section 6) 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C.Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. OR N.z'?sms.._ ""s..�a1_,.1r, .`A. »� ..✓+- -r»'.'_ .k- _.sfk_,...�.'�,.e..�i... .yr._-.-, -_ �.. .*�?_., ..? 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 /�R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements,but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof(tear-off)or recover applications,subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 5 2� STA'itTER SRINGLES O_�ST/1RTER STRIP^.,, %-� :„ '"'r•� z ,E-x-'�' � r r' r' � ,+-� }�.� ' �:�-' � {,� 6.2.1 Installation of Pro-Start®Starter Strip Shingles(fka,Pro-Start®Eave/Rake Starter Strip Shingles),WeatherBlocker'"` Premium Starter Strip Shingles(fka,WeatherBlockerT"Premium Eave/Rake Starter Strip Shingles)and QuickStarto Peel&Stick Starter Roll shall comply with the GAF current published instructions. Y6 3 �� P#iA-l:L_SH�NG�,ES'-�s'� 3,;. '� _� r � ��� �} ���.,> �' � �.; Y r�� -•���` s-" - v.� I.. � ,:✓',=„+v�d k„. .n"w"re:,�&�` 1„.� ".`� r.r.. �- Mtn '.,t'-'�... "�"� �� ..f� .s�."_..�`'� ..,r'"`�'^-rr,?.u.� 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: ➢ Camelot® II,._Grand .Canyon®, Grand. Sequoia",.Grand.Sequoia® I.R, Grand Sequo)a®.ArmorShield", and Woodland®require minimum five(5)nails per shingle. ➢ Slatelinelm requires minimum six(6)nails per shingle. NEMO ETC,LLC Evaluation Report 01506.01.08-1130 Certificate of Authorization#32455 71"EDITION(2020)FBC NON-HVHZ EVALUATION FL10124-R28 GAF Asphalt Roof Shingles Revision 30:09/21/2020 Page 6 of B � ONEM10jetc. 6.3.2 FasteningforFnrtkude''Timbedine*AH'TimbedinevCSandTimbedine"HDZ=;slopes2;13uptnZ1:12 1/2--2-117(13MM-UMM) =UZ 113.m-64MM) TARGET NAIL ZONE STANDARD HAILING PATTERN: Nail shingles approximately 6 7/8'(174 mm)from bottom of shingle,in nailing area,as shown.Nails must not he exposed.Not for use on Mansard roofs(21:12 slope and above). 6.33 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the GAF for details. Fastening for Fortitude',Timberline"AH,Timberline"CS and Timberline"HDZm;slopes greater than 21:12 shall127 3 1-) EJ El I I These shingles MUST be nailed a nominal 6'(152 mm)from bottom of shingle,above the cut-outs,as shown.Nails must not be exposed. Ace 6.4.1 Installation of Seal-A-RidgeO Ridge Cap Shingles ^ ~~^'p', with the G°' `"''e"' p"""==" ` instructions with o minimum two (2) nails, minimum 3/O-inch head diameter located G-7/8' inch back from the exposed end and 0.5'inch Nail from the edge. clavo Clouer - ' — 6.4.2 Installation of Seal-A-RidgeO ArmorShleldmand Seal-A-RidgeO AS shall comply with the GAF current published instructions with a minimum two(2)nails,minimum 3/8-inch head diameter,per shingle located 6 to 6.5-inch back from the exposed end and 1to2-inch from the edge,and nominal O.2S'nch diameter beads of Henkel°LoctitePL S3o Roof&Flashing 5ea|am.. mcIVIo ETC,uc Evaluation Report 01506z1.08-1130 c*tift"mofA"th"riz"m=oom55 7-EDITION<aozo pacmom'xxozEVALUATION r1.1012*1128 GAF Asphalt Roof Shingles Revision so.u9/21/zozo Page 7 of DEMO I etc. 11.5' ( 292 min ) Sealant (25 mtn) (25 mm) Nail # �� �w°°y 127 �\ 'CA ��' Nail (305:mm) �.' ��' (152mm-165mm) 12'. • (305 Mini) 6.4.3 Installation of Timbeil Premium Ridge Cap its• Sealant Shingles shall comply with GAF current 292mm) 1'�Sellante (25 mm Enduit d'6tanch6it6 (25 mm) published instructions with a minimum two (2) � nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn"NP1 Gun Grade Polyurethane Sealant" or Henkel "PL Roofing and Flashing Sealant". Neil Clavo 12' JClouer (305 min) g. (229 min) 12' (305 mrn) r • As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. ULLLC—QUA9625;(414)248-6409;karen.buchmann@ul.com . END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.01.08-R30 Certificate ofAuthorizotion#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10124-RZS GAF Asphalt Roof Shingles Revision 30:09/21/2020 Page 9 of 8