HomeMy WebLinkAboutPROJECT SPECIFICATIONSOF ROOF BEAT .' COLUMNS, PURLINS Ar e THIS POLY ROOF SHED MEETS THE FLORIDA BUILDING CODE FOR A HEIGHT 8'-6", 150 MPH, EXP. 'C' WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION OF FLORIDA (AAF) "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL VALUES FOR EXTRUDED ALLOY 6005T5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL, 2015 EDITION. TABLE 1 MAIN ROOF MEMBER SCHEDULE. _ MEMBER IMARKIMANFJ WEIGHT ATERIA THICKNESS— LENGTH DESIGN BASIS- # I SKIN 1POLY1 SKIN I FT. FL. PROD. APPR. POLY ROOF PANEL # 1 I PRP1 I ELITE 1 1 ALUM 1 3" 1 0.024 13'-0" FL7561-R3, DWG. IFL-1001, OR = 3-20-15 TABLE 2 MAIN MEMBER SCHEDULE PRODUCT INFORMATION TABLE: NOTE ALL SIZES ARE NOMINAL. TABLE 1 MEMBER I SIZE ILENGTH MATERIAL / NAME MANF'R I DESIGN IN. I IN. I I I BASIS DOOR HEADER (2) 2x4 36 YELLOW PINE, GRADE (#1) NA NA WALL STUD 2x4 VAR. SPRUCE, GRADE (#1) NA NA BASEPLATE 2x4 NA YELLOW PINE,.GRADE (#1) PT NA. NA . HEADER 2x4 NA YELLOW PINE, GRADE (#1) NA NA FLOORS (EXISTING) 4 VAR. CONCRETE SLAB NA NA HURRICANE TIE NA NA HURRICANE TIE A34 SIMPSON SIMPSON CAT. SHEATHING 7116 VAR. 7/16' OSB PLYWOOD NA NA TYVEK HOUSE WRAP NA NA DUPONT NA NA VINYL SIDING NA NA NA NA NA TABLE 3 MAIN COMPONENTS SCHEDULE COMPONENT MANUFACTURERIMODEL #-PRODUCT APPROVAL RATED MAX. PRESSURE SIZE INSTALLATION INSTRUCTIONS HVHZ RATED PRESSURE REQUIRED PGT CABANA DOOR FL331.1-R12 +/- 50 PSF I 36"x80" DWG. # 1093011JR NO +28.0 / -35.6 PSF PGT INDUSTRIES MODEL CD-290 I I DATED 6110115 NOTE: THE DOORS AND WINDOWS IN TABLE 2 CAN BE REPLACED WITH OTHER WINDOWS AND DOORS -PROVIDING THE FLORIDA PRODUCT APPROVAL FOR THE OTHER DOORS AND WINDOWS MEETS THE REQUIRED PRESSURE RATING. ADDITIONAL SITE SPECIFIC INFORMATION THIS POLY ROOF WOOD SHED IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SE WALTON ROAD AND EAST OF U.S. ROUTE 1 IN PORT ST. LUCIE. THE WOOD SHED HAS SOME OPEN AREAS AROUND IT. THE PER THE EXPOSURE CATEGORIES LISTED IN SECTION 1609.4.3 OF THE FLORIDA BUILDING CODE THIS SHED SHALL CONSERVATIVELY BE CALLED AN EXPOSURE'C'. ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF 'APPLIED TECHNOLOGY COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY I ENCLOSURE IN THIS LOCATION IS DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND LOAD, EXPOSURE 'C', RISK CATEGORY I. THIS POLY ROOF WOOD SHED IS BEING INSTALLED NEXT TO A MOBILE HOME. THE SHED SHALL BE A STAND-ALONE STRUCTURE. THE FRONT IS 8'-6" HIGH AND THE BACK HEIGHT IS 9'-6" HIGH; WITH A RUN OF 3.0 FEET GIVES A SLOPE OF ABOUT 41NCHES PER FOOT. THE POLY ROOF WOOD SHED IS BEING BUILT ON AN EXISTING NOMINAL 4" SLAB THAT IS IN GOOD CONDITION. THIS FOUNDATION IS ACCEPTABLE FOR THIS SHED- THE DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF CONNECTION DRAWINGS ARE SHOWN ON SHEETS 3. THE HOST STRUCTURE IS A MODULAR HOME SO 4TH WALL CONSTRUCTION FOR COMPOSITE ROOFS WILL BE USED. THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN THE WOOD SHED AND THE MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL FLASHING TO KEEP THE RAIN OUT. THE CARRIER BEAM (HEADER) WILL BE A DOUBLE WOOD 2x4. THE NEW CABANA DOOR WILL BE INSTALLED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NEW CABANA DOOR IS SHOWN IN TABLE 3 ABOVE. SPECIFICATION NOTES AND DESIGIV rARAMETERS: THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE FLORIDA BUILDING CODE (FBC), 5TH EDITION (2014) BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A. THE AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR TABLE 1 ARE APPLIED. A DESIGN BASICS: THIS POLY ROOF SHED IS A RISK CATEGORY I STRUCTURE. HEIGHT 8-6",150 MPH, EXP. 'C' B THE BUILDING CLASSIFICATION RISK CATEGORIES ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED PER FBC, FIGURE 1609C.. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10. -C DESIGN PRESSURE: FOR SOLID ROOF @ 30.96 PSF PER TABLE 2002.4. D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD. E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC. F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES. 2 MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE. B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS. ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHODS. C. SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN.FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58% OPEN MINIMUM. OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION. D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL FBC AND AAF GUIDELINES. E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBER, RESPECTIVELY. G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT SCREENING OR KICKPLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER. H ALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER. I IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE COLUMNS ARE NOT DISTURBED. 3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS, COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS, ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL CONNECTIONS SHALL MEET THE FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR. 4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING, EAVE RAILS AND CHAIR RAILS,'ALONG WITH ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SITE SPECIFIC DRAWING". 5 ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED TO ASSURE THERE IS SUFFICIENT HOLD DOWN CAPABILITY TO MEET THE REQUIREMENTS OF A THE ENCLOSURE. 6 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST, BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C. 7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS: A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH. B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2". I 8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B 47NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS, C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE, D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE. 9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTERS. 10 ALL NEW PERIMETER FOOTER POURED WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS: A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED, B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE. 11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. 12 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL, PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT. NEW WOOD SHED DWG. # RVC-2017-901, REV. 0 December 5, 2017 SHEET 1 OF 3 GENERIC DESIGN DATA HEIGHT 8'-6", 150 MPH, EXP. 'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: DeLUCA RESIDENCE ADDRESS: 3108 8TH HOLE DRIVE CITY/STATE: PORT ST. LUCIE FL 34952 COUNTY: ST. LUCIE DEC I � 2017 PERMITTING St. Lucie Couni . FL THIS DRAWING IS ONLY ACCEPTABLE FOR BUILDING PERMITS & ONLY WHEN IT HAS THE ENGINEER OF RECORDS RAISED SEAL. COPIES ARE NOT DEEMED VALID. THIS DOCUMENT IS THE PROPERTY OF R. A. DUNLEA, P.E. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF R. A. DUNLEA. R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(ab-centurviink.net FLORIDA P.E. Lic, No. 42835 ■ C __T: 1'-1" L 3.5" 3'-0" 6'-0" 3.5 P EXISTING SHED 9'-6" 15/32" PLYWOOD W/ TYVEK & VINYL SIDING (TYP.) CABANA DOOR PLYWOOD W/ TYVEK WRAP & VINYL SIDING (TYP.) 15/32" PLYWOOD W/ TYVEK'& VINYL SIDING (TYP.) 8'-6" LEFT SIDE ELEVATION VIEW NOTES: I. SIMPSON HURRICANE TIES, A34, OR EQUAL, SHALL BE INSTALLED AT TOP AND BOTTOM OF EVERY WALL STUD AND DOOR FRAME. 2. ALL WINDOWS AND DOORS WILL HAVE DOUBLE 2x4 FRAMING ALL AROUND. 3. SUB -SIDING WILL BE 15/32" OSB PLYWOOD AND NAILING DETAIL IS 6" O.C. ON EDGE AND 8" O.C. IN THE FIELD. 4. 3'8" DIA. TAPCONS, WITH 2-1/4" EMBEDMENT, THRU BASEPLATE 4" FROM EDGE AND EVERY 24" O.C. 5. THE CONNECTION FOR THE POLY ROOF ON SHEET 3 CAN BE USED FOR A WOOD STRUCTURE BY CHANGING THE SELF TAPPING SHEET METAL SCREWS TO NORMAL WOOD SCREWS OF THE SAME SIZE. 6. THE BACK WALL OF THE WOOD SHED WILL BE THE SAME AS THE FRONT EXCEPT IT WILL BE 12" HIGHER AND THERE WILL BE NO TYVEK OR VINYL SIDING. 7. THE RIGHT WALL WILL BE FORMED WITH 2x4, 16" O.C., WITH PT BASEPLATE AND TWO (2) 2x4 BRACES, 3'-0" FROM THE FLOOR AND 3"-0" FROM THE ROOF. 8'-6" ... SITE SPECIFIC DRAWING J MOBILE HOME 3.5" 12" 3" - 1 LB. OH POLY ROOF W/ 0.024" SKIN (PRP) 12" OVERHANG PLAN VIEW EXISTING SHED I 9'-6" I 1 2x4 <-2x4 <- OPEN M O 2x4 t B A34 HURRICANE TIE I (TYP.) L E 2x4 <-2x4 OPEN BP-> S <-2x4 6'-0" H O 2x4 M <-2x4-3 FEET �� E OPEN <-BP 2x4 -3 FEET <-2X4 2x4' 8'-6•• RIGHT SIDE ELEVATION VIEW 1 1 3.5" 14.5" 11 14.5" 3'-0" FRONT ELEVATION VIEW NEW WOOD SHED DWG. # RVC-2017-901, REV. 0 December 5, 2017 SHEET 2 OF 3 SITE DESIGN DRAWING HEIGHT 8'-6", 150 MPH, EXP. 'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: DeLUCA RESIDENCE ADDRESS: 3108 8TH HOLE DRIVE CITY/STATE: PORT ST. LUCIE, FL 34952 COUNTY: ST. LUCIE DRAWINGS NOT TO SCALE R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(ab-centurVlink.net FLORIDA P.E. Lic. No. 42835 � SAT V •• O� •'•FCOR40P' . ���o AL {Y i✓Oit4�CTQIV.TQ.:$T1JC'TUAEE. wYM GENE NO+ E "10 rOR dSPdil A i ION LpCTSaLTl�:.iD` Q.C,.Ec ENDS 1Q.2' SOVfVD - {t,.EJVSDREFASCIAiSSfCUREL-Y•FR�FEIVED;iV• '. ''.OZ4' cia. i, r=T�x vJZTft (?�`•ti X.. ' 1 G lvdn. C . 3GS TG iFfERS ENSU)xE jai'. hII�i. PE�1cTFfAi ieN t�kE,DFIIt..L.. = TD A'YOM S-LYTTING C4�VCRE TE �F41 F7� ;;•tdj; . k/EELr-lP-23 FILUEED MASONRY* A314 . 56%-XI3/4° EMBED ` ENDS BAL @ IS'-; % \ NAX.O.C.# 2• NOMINAL STRUCTURAL-`ELTTE FACIA MINIMUM EP- 'NOTE' USE %'X13'4 EMBED x14x3/.- SMS @ 7. 0. C. (9) PER 4' PANELTOP>§ ° BOTTOM. ADD (2) SMS 2' R 4° FROM EACH 114" MAXS, O 4O FROM ENDS, ENCLOSURE END TOP&.BOTTOM. HEAVY MAX D.C.C, TO NOLLOW BLOCK "ADHESIVE CAULJCTOP & BOTTOM CONTINUOUS EN"CLOSURE 1 O CONCRETE DECK ►iCHONG DETAIL *SEE GENERAL ND 4 l0 FOR ATION C OLUM.PE R-TABLES OR 3'XVYz -/e' ANGLE WITH (2) 314'z13/4' EMBED, SEALED`SITE-SPEC HC TAPCONS W/%' MIN. WASHER DIAMETER TO WLAW NG6S/i.7ALCULATIONS SLAB, 2%' APAFR & 3- FROM SLAB EDGE & (6) #14 SMS TO COLUMN,'}' MOM ANGLE EDGES, ONE EACH SIDE OF COLUMN Nl 1/E-aS-P.3G.CDNGREiE SLAB & FOOTING. SE15 SITE SPECIFIC DEFA--_13RADI)M N AL FOOTING ENGINEERING SHEET .EAVE SEAM CONFECTION @ WALL SEE GENERAL NOTE FOR LIMIT TIO EPS POLY (USED AS R@QURIED WHEN ROB CONNECTING TO WALL) % THRU8OLTTHROUGH 0 2'13'A' ANGLE TO ROOF, 3":3°:3's' ANGLE FASTENED TO INSIDE & 80TTOKOF CARRY BEAM W/ (Z) YV LJ3-� THRU80Li5 SIDE, (5) #i4 SMS BOTTOM, '124RtRY BEAM PER FASTENED TO CBS WALL W/ (2) 3/J WAN EMBED TAPCONS OR TO WOOD (MIN 2X, Sf'EC_!FIC 1NTEGR1TY BY OTHERS) WITH (9)ii4x1x° r t r y..� ui• ,a:, Top r, I? 3Gi Tom) .G97' SEETABLE_,3151 W ih}F�y1SIO(i,5 W �j tt pE�[GM i tp 1NS7ClNPgIOR TU;Ll SE, L7-f2NA I� :E N. ^fcEA ThfC-"'AJIEL 2;, 3 E;>'E4'CGHETJ::'rZ7R'D• �{ENSiOf45 BOX E3 -3^i!hlr(bEAS 5F?.GIFiEO ,q BEAM o If#r', 4LL EjCi iLg Id*NS T.0 BE Ch it o z x VARIES LAP SE;14 .r." ! 2A° 1 • is 055 TP. 1 g 1X3 BEA.Ml TOP SIDE "SaC nP "i Bc?Id c m 2X4j. l ia'1.045' .Tl)2c i 3 l I Z° d' .a50°I rV JI s•�iO�nfl'-r Lz-s'.� •• j , ., � o ? �; a .zio= .a7a•I . '-3"''SIC(?rc :.t'• �' �a'�-( �' ZX10.35GI.Oa2�I_ RUUU - 61jxiv CL J .UN N L:. i Tory- FRO N T E.LEVA T' O N • ,f iNL'CUS -- MIN ACOF TC.i l-S'.' =E1 '�j° SECTION ,A T BE- A�NG CoL UMN (OPT.).Ci v a v a v . a OPTION 1: USE W LA6 BOLTS W/ 1' MIM -WASHER OLV4ETER,. 1' KrN. LONGER THAN PANEL T`IICKNESS SPACE13 PER LAG SPACING TABLE THIS OETAIL- OF] ION 2: V40 THRUBOLTS TO ROOF, 4• FROM ENDS SL 17- 04- TO 2'Y2'' ANGLES (EITHEFC SIDE IF REQUIRED BY BUILbING O€PT). gl�x%4° SMS 'IV I YP.. TOP a 3GIT OM WL = WAL LOAD RL = ROOF LOAD c v CARRY BEAM PER TABLES OR SEALED •SITE SPECIFIC . ORAWINc9f C 3LO.1LAnawS f BOTH OPTION$: (2) %' THMECILTS, n O CARRY BEAM-10 COLUMN a o NOTCH_COS.UMN IN Cal TER TO FIT IY CURRY BEAM SNUG WT H OPTIONS) 3°Y3="%V? ANGLE, (6) 414 SMS EA LEG, 1=A 413E OF COLUMN , COWMN PER fiASLES OA SEnl�n SITE SPECIFIC DRAWING/CALCULATIONS P 'I LAG' -PACING TABLE It'..O.a3#'f11 ; ,O.123V 1003IP5 ii'O,C1.13' O.0 '?0 3 1.30 5 7 Psr to ,2ER -11I11)I •I' AEL (' PEQ 3 . ANEL YIC 3a PSr B° a.G 1o' O.C. za C 130 C mm PER s4'dAl4tt ° ° PER �ANEL 30 a C ito, PSF 50 C ' SECTION_ AT SIDE OF ROOF PANEL i. W LAGS, 4- FROM ENDS a 24' MAY- a.G, 1° nw 1? /• LONGER THAN PANEL TAIC0MEESTO SECURE ROOF Sh15 la° �TO NomrPiUMPA.Y WALLS ONLY. CALILK ALL ScPAW T(P, TOP A� HEADS' BOTTON . •o a v.° c ° SITE ROOF PANEL v rAL 2 X 2 BOX M. 2 X2'x%e' ANGLE, (3) -,14 SMS EA O LEG, E4 20E OF BEAM 4- 310 S.M.S. FROM INSIDE FACE OF POST INTO SCREW SPLINES SIDE OF HOLLOW GIRT (1-112" MEE EMBEDMENT MIN.) TABU eELovu} I ___----__ •'.1 4 SMS GIRT OR CHAIR RAIL n =NOS a MAX TOP ?• 6O—i I'DM 'SELF MATING POST-� INTERNAL SCREWSYSTEM MAY BE SUBSTITUTED EXTERNAL ANGLE CLIPS CONNECTION w/ CONCEALED FASTENERS PARTIAL ELEVATIONS / GIRT TO POST CONNECTIONS SECTION AT BEARING ' COLUMN *12x3/4" SMS @ 16" TYP. TOP & BOTTOM o 0 0 0 0 0 EPS POLY 0 ROOF 0 0 ELITE TYPE 'E' °o ° o GUTTER OPTIONAL. i4 / 12 SLOPE ADAPTOR SHOWN USE Y" LAG BOLTS W/ 1" MIN. WASHER DIAMETER, 1" MIN. LONGER CARRY BEAM PER TABLE_2 . THAN PANEL THICKNESS'• :YN11t1V.tfi511=NIiG TO `ALUMINQR ttSE -TP IFAST HII-x (1 : 3/4) AT r O.E. FOR UP. FOR •COMPOSF- E-ROOFS: ► O 130'MPH-!n/IND SPEEl) ' #10 x (t + Al2°y 6,XS. W/ E,`{POSURE °D"; 1-1/4'0ENR;AS8., HERS ABOVE' 130 MPH ADD UP I O .1.5a MPH 1MND-SPEED PANEL THICKAtNSS'+ 1"} E;POSURi= °D° @ ROOF BEARING ELEMEW4 • • - • -(s�tavvNj •,�ID.z4�o:c. CAU.UK ALL 0C-OSED:SCREW NO"EARING ELEfi Efff (51nE :HEADS: � WASHERS • y{. "y FOP. PAN ROOFS: (3 EACH #S x 1/2",LONG S_M - - P-ER:1Z'.PkIiE L 1'3 `::-- :: - _ -AL�JivIF�tE1�PPP�t1RIASF[ER ROOFPANEL o SCIPPORT FNG• BEAM ROOF" -PANEL REAM F STENIF G-DETAI:. m c x Z• x 1/S-ANGLE EACH SIDE J3;-014 SMS EACH SIDE311P CODIA.CONCRETE ANCHOR -O.C. MIN. (TAPCON OR EQUAL) w! ' 2- EMBEDMENT IN. r MIN- ■. 1) THIS DETAIL MAY NOT BE USED 1I- XZ- UAS, BASE PLATE 1 FOR COLUMNS LARGER THAN r x 3-, r MI- ` ` '�, c 4) CONCRETE FASTENER SPECIFICATIONS: 2) TWO (2) ED ORIA. BOLTS MAY M N CONCRETE FASTENERS MUST HAVE A OUTS EPLA FOR THE 3 - S14 BE (2 r . BOLTS REPLACE 6 SCREWS) � (MIN.) ULTIMATE TENSION CAPACITY OF 3) THIS CONNECTION CAN BE USED IN �... 2,S68 8 OR A WORKING (MINIMUM) TENSION CAPACITY OF 848#, AHD, A (MIINIMUM) WOOD BY USING SIMILAR SIZE - • 1"`°'� - WORKING SHEAR CAPACITY OF 3TIOtl. (DO SCREWS W 71iE HEADER. 'S, NOT SUBSTITUTE Mir DUL CONCRETE ANCHORS FOR LARGER SIZE ANCHORS.) COLUMN / FOUNDATION FASTENER FOR 2x2 AND 2x3 LOAD CONDITIONS: CONNECTION UPLIFT CAPACITY = 1,100#, SHEAR CAPACITY = 228#. 73" NEW WOOD SHED DWG. # RVC-2017-901, REV. 0 December 5, 2017 SHEET 3 OF 3 POLY ROOF CONNECTIONS HEIGHT 8'-6", 150 MPH, EXP. 'C' R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772).380-8253 LICENSE # CRC 1330965 LOCATION: NAME: DeLUCA RESIDENCE ADDRESS: 3108 8TH HOLE DRIVE CITY/STATE: PORT ST. LUCIE, FL 34952 COUNTY: ST. LUCIE THIS "CIRCLED" CONNECTIONS ON THIS SHEET ARE BEING. USED FOR THIS PROJECT. 1 2 3 4 5 6 7 8 9 10 11 NOTE: DRAWINGS ARE NOT TO SCALE R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunleaCM-centurviink.net FLORIDA P.E. Lic. No. 42835