HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFI'1Product Approval
t.
'fir USER: Public User
Product Aooroval Menu > Product or Aoolication
Search > Aoolication List > Application Detail
FL #
FL19621
Application Type
New
Code Version
2014
Application Status
Approved
Comments
Archived
rr
Product Manufacturer
x T,
Address/Phone/Email
Authorized Signature
r '.#
}-r
s
Technical Representative
N }
Address/Phone/Email
Quality. Assurance Representative
Address/Phone/Email
' Category
�__-'„ ,;:'r: Subcategory
Florida Engineer or Architect Name who developed
the Evaluation Report I
Florida License
Quality Assurance Entity
Quality Assurance. Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Sunlast Metal
2120 SW Poma Drive
Palm City, FL 34990
(772) 223-4055
Oval Idati on@yahoo. com
Terry Kapron
Oval idatlon@yahoo.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Locke Bowden
PE-49704
Keystone Certifications, Inc.
03/02/2026
Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Ft t9621 RO COI Fl, 17701 Sunlast Metal ssrodf
Standard Year
TAS 100 .1995
TAS 125 2000
TAS 125 2003.
https://floridabuilding.org/pripr_app dtl.aspx?param=wGEVXQw...2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXHl7%2bti8c9lg%3d%3d 10/23/16, 6;33 PM
Page 1 of 2
Equivalence of Product Standards
Certified By
,t
K.
s
Sections.from the Code
C t F " i r•)
[
h VI
Product Approval Method
Date Submitted
v
Date Validated
q
Date Pending FBC Approval
_+ t
Date Approved
a
+ I
_
Summarv.of Products
Method 1 Option D
12/18/2015
12/18/2015
12/21/2015
02/10/2016
FL',#
Model; Numtler or -Name
Description
19621.1
"Key West Series" 5-V. Crimp -HVHZ
26 GA. HVHZ 24" Width
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
LF 19621_gQIl FL 17701 Sunlast Metal scrndf
Approved for use.outside HVHZ: Yes
Verified By; Locke:Bowden, P.E. # 49704
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +n/a/-189:25
Evaluation Reports
Other:-78.5psf @ 16" o.c.-189.25psf @ 8" ox, Install per
FL19621 RO AE FL 17701 Sunlart Metal ssr.odf
manufacturer instructions and RAS 133 in compliance with
Created by Independent7hird Party: Yes
FBC 2014 For HVHZ use
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
j ill! The State of Florida. is an AA/EEO employer. Co�r'ght 2007-2013 State of Florida Privacy Statement ;; Accessibility Statement :: Refund Statement
' Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. if you have any questions„ please contact 850.487:1395..•.Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees. licensed under Chapter 455; F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If. you do not wish to
supply a personal address, pleaseprovidethe Department with an email address which can be made, available to the public. To determine If you are a licensee under
f Chapter455, F.S.,.please click -here .
Product Approval Accepts:
Im
PAN ECFEC,
Credit Card
Safe
f
httpst//fioridabuilding-org/pr/pr app_dti.aspx?pararn=WGEVXQ 2fGGFsMxvHNQgk6GRNt8kduX9Ye74PcXH179o2bti8c9lg%3d%3d 10/23/16, 6:33 PM
Page 2 of-2
Locke Bowden, P.E.
9450 Alysbury Place
Montgomery, AL 36117
Manufacturer: Sunlast Metal, lnc..
2120 SW Poma Drive
Palm City, FL 34990
Code Compliance: Florida Building Code 2014
Rule # 61G20-3
Category: Roofing.
Sub -Category Metal Roofing.HVHZ
FL 17701.
"Key West Series"
Product: 5V-Crimp Metal. Roof Panel
Support Substrate: 15/32" APA Wood Deck min. over supports at 24" spacing maximum
Material 26GA steel Yield StrenO'h 55ksi min. Corrosion resistant: Material to comply with FBC
section 1517.6 for HVHZ (Design of support system not included in this -report)
Panel Dimensions: Thickness=266A.steel . Width::24"- Rib Height: 5/8" High rib:12"o.c
Slope: 2/12.min. or greater in compliance with FBC 2014; Section 1515.2
Underlayment: In conformance too FBC 2014.
Fire Classification: Not within the scope of this report.
Fastener: Corrosion resistant #10-1-1/2 (3/16 . min. penetration through support; Wood-Zac.
XG Fastener, Hex Head w/Neoprene washer fastener or equivalent In compliance with FBC
Section 1506.6 and 1507.4.4
Insulation: Optional -Rigid insulation board, 3" max thicknesscompliant with: FBC 2014 Section
1508.2
Installation: Install per manufactures details,and RAS 133
w.__!_._ ■ 1.-nA& n- . T..L.1e A
WeSISF1 NIAIIL rl Ca.7Y1 C. I.aY1c r+
Roof Areas
Field
Perimeters and Corners
Max.. Design Pressure
. -,78.5 psf
-189.25 psf
Fastener. Spacing
16" O.C.
Fastener Size
##10 .
#10
*Maximum. Design Pressures include 2:1 Safety Factor
Quality Assurance: in accordance with FBC 2014 and Rule # 61G20=3: Keystone Certification,
Inc. QUA 1824
Code Compliance demonstrated.; Florida Building Code 2014 Section 1523.6.5.2.4.1
This.report is limited to compliance with the structural wind load requirements, of the FBC.2014.
Required wind loads shall be determined: per: project per FBC 2014 and any rational analysis
computation -shall be prepared by a licensed design professional.'
Reference Data:
Architectural Testing Inc (TST 1527) #FO755..01=450-18
Architectural Testing Inc (TST-1527.) #04.12-1017-05
Architectural'Testing Inc. (TST 1527) #SFMS-001-02-01.
PRI Construction Material Techl11. ologies(TST5878) AKZC-001-02-01/05
PRI Construction Material Technologies(TST5878)AKZC-�001-02-01/05
AKZO Nobel Coatings, Inc. Lab Form
TAS 125-2003
TAS-125-2003'
TAS 100-1995
TAS 110-2000
ASTM -B 117-2002
AST M G 153
Locke Bowden, P.E. -�
9450.Alysbury Place
Montgomery, AL 36117
Manufacturer: Sunlast Metal, Inc. FL 17701
2120 SW Poma Drive
Palm City, FL 34990
Certificate of Independence
Locke Bowden, P.E. does not have, not will acquire financial Interest In any company manufacturing or,
distributing products under this evaluation.
Locke Bowden, P.E. is not owned, operated or controlled by any company manufacturing or
distributing products under this report.
Install Detail
TYPICAL ASSEMBLY PROFILE VIEW Fastener: #10-1-1/2" WoodZac XG
Perimeter/Corner fastener spacing 8"o.c Field fastener spacing 16"o.c.
t�
do
a
300 Tam* 'A" s •
�\ s
Ems.
oveluip ®,,tt1i911i►p
tia C.1�Gip p p,bNo. 49704
O
Lofike Bowden,. P.E.
FL — 704 S-fATE OF
1-4AI-
C- �..`
���trieIIIIIItt►��
EXTERIOR RESEARCH & DESIGN, I.I.C.
— Certificate of Authorization #9503
TRINITY ERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R22
150 Lyon Drive FL5259-R26
Fernley, NV 98408 Date of Issuance: 02/24/2009
(570) 384-1230 Revision 22: 03/13/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 03/13/2017. This does not serve as an electronically
signed document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and to the
named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments,
following sections of the Sth Edition (2014) Flor
Compliance is subject to the Installation Require
2. STANDARDS:
�l TRINITY I ERD
produced by Polyglass USA, Inc., have demonstrated compliance with the
Building Code through testing in accordance with the following Standards.
its and Limitations / Conditions of Use set forth herein.
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2004
1504.3.1
Wind Uplift
UL 1897
2004
1504.6
Accelera6d Weathering
ASTM G154
2006
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3,
Physical properties
ASTM D226
2006
1507.8.3, 1507.9.3
1507.2.4, 1507.2.9.2, 1507.5.3, 1507.7.3
Physical Properties
ASTM D1970
2009
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.3.3
Installation Practice
FRSA/TRI April 2012
2012
1523.6.5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRIO1111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Prloperties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical PrQ� perties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Prolperties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Pro erties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD (TST 6049)
Wind Uplift
I
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift I
P1740.01.07
01/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift I
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift I
P30540.11.09-131
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift I
P11030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
Exterior Research and Design, I.I.C. I Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 2 of 14
�TRINrry-'JERD
Entity Examination Reference Date
ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011
ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011
ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012
ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012
ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013
ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013
ERD (TST 6049) Wind Uplift 11757.04.01-1-Ri 04/30/2013
ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013
ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013
ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013
ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014
ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014
ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014
ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014
ERD (TST 6049) Physical Properties P44360.10.14 10/01/2014
ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014
ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015
ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015
ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015
ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016
ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016
ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016
ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014
Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/18/2009
Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008
Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 04/24/2018
4. PRODUCT DESCRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self -Adhering Underlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced,
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate afAuthorization #9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 3 of 14
V
TRINITY ( ERD
4.2.4 Polystick TU Plus is a nominal 80-mil th ck rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D 1 970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and AS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
4.2.8 Polystick Dual ProTM is a nominal 60- it thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.9 Polystick Tile ProTM is a nominal 60-111 thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil (thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film srface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of an sand -surfaced SBS
modified bitumen back -side and granulsurfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofipg" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (04-121) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from RSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternatelto Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanicallyfastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap S eet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are poly)I ster reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened ol(I adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neith' r Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evacuation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in thel HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not Ilisted, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combin d with supporting data for the prepared roof covering.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017 I
Page 4 of 14
C)o
` '\JTRINITY ERD
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
& Shingles
Slate
Elastobase
Yes
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polystick MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystick Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLETILE ADHESIVE, UNDERLAYMENT COMBINATIONS)
Adhesive
Florida Product
Underlayments
Approval
Convenience Products' Touch'n
FL14506
PolystickTU Plus, PolystickTU Max
Seal StormBond Roof Tile Adhesive
Dow TileBondT1
FL717
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® AH-160
FL6332
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap
FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap
FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile
FL17855
Polystick TU Plus or Polystick TU Max
Adhesive
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION, FL5259-11126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 5 of 14
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile I
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41
plywood; New or existing, unprimi
Southern Yellow Pine; ASTM D41
(designed and installed to meet win(
Note: Polyglass does not require primii
OSB sheathing should be cleaned of all i
Elastoflex G TU, Elastoflex S6 G or Elasto
➢ ASTM D41 primed structural concrete
Polyflex G or Polyflex G FR torch -applied
➢ ASTM D41 primed structural concrete
rTRINITY I ERD
Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
)rimed new untreated plywood; Existing plywood; ASTM D41 primed existing
J OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
rimed structural concrete; Huber Engineered Woods "ZIP System" Panels
loads for project).
a of new or existing plywood or OSB sheathing. New or existing plywood or
,rt and debris prior to application of Polystick membranes.
`lex S6 G FR in hot asphalt to:
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanu rate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber IRoof Board.
Polyflex G or Polyflex G FR torch -applied to:
➢ ASTM D41 primed structural concrete;; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
5.6.3
5.6.4
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covell'ing manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in acicordance with FBC Section 1504.3.1.
Polystick (all variations), Polyflex SAP or
Tile Pro self -adhered to:
➢ ASTM D226, Type I or II felt; Elastobase
Elastoflex G TU, Elastoflex S6 G or Elastoff
➢ ASTM D226, Type I or II felt; Elastobase
Polyflex G or Polyflex G FR torch -applied t
➢ Elastobase; Elastobase P, Mule -Hide Ni
For installations under mechanically atta
codified requirements. For installations
requirements of FRSA/TRI April 2012 (04-
accordance with FBC Section 1504.3.1.
address wind uplift resistance of all undo
forms part of the load -path. The follo%
addressed in FRSA/TRI April 2012 (04-12)
result of testing for wind load resistance
divided by 2 (the 2 to 1 margin of safety 1
12), Appendix A, Table 1A or FBC 1609 for
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
FBC
FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Elastobase P or Mule -Hide Nail Base.
c S6 G FR in hot asphalt to:
Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
I Base, Polyglass G2 Base or Polyglass APP Base.
hed prepared roof coverings, base layer shall be attached per minimum
under foam -on tile systems, base layer shall be attached per minimum
2), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
is in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
ayment systems beneath foam -on tile systems, where the underlayment
ng wind uplift limitations apply to underlayment systems that are not
id are used in foam -on tile applications. Maximum Design Pressure is the
ased on allowable wind loads, and reflects the ultimate passing pressure
r FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
etermination of design wind loads.
Evaluation Report P12060.02.09-R22
Z EVALUATION FL5259-R26
USA, Inc. Revision 22: 03/13/2017
Page 6 of 14
Q'TRINITYIERD
5.6.4.1 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.2 Maximum Design Pressure = -97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
5.6.4.3 Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure = -135 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.5 Maximum Design Pressure = -315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.6 Maximum Design Pressure = -622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having. Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.8 Maximum Design Pressure = -37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION 171.5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 7 of 14
5.6.4.9
,-,,I TRINITY ERD
Deck: Min.19/32-inch plywood to imeet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTIM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-inFh head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.10 Maximum Design Pressure = -45 psf*:
Deck:
Min. 19/32-inch plywood to r
Base Sheet:
One (1) layer ASTM D226, Tyl
Fasteners:
11 ga. x 1.25-inch x 3/8-inch i
Spacing:
4-inch o.c. at the 2-inch wide'
Base Ply:
(Optional; for use with self-ac
Underlayment: Polystick TU P, Polystick TU P
Mule -Hide SA-APP Cap Sheet
feet project requirements to satisfaction of Authority Having Jurisdiction.
e II felt
ead diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
;ide laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
hering underlayment only) Polystick MTS PLUS, self -adhered
us, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
5.6.4.11 Maximum Design Pressure = -45 psf*,
Deck:
Min. 19/32-inch plywood to m
Base Sheet:
Two (2) layers ASTM D226, Ty
Fasteners:
11 ga. x 1.25-inch long x 3/8-in
Spacing:
9-inch o.c. at the 2-inch wide I
Base Ply:
(Optional; for use with self -ad
Underlayment: Polystick TU P, Polystick TU PI
Mule -Hide SA-APP Cap Sheet
asphalt.
5.6.4.12 Maximum Design Pressure = -45 psf:
Deck:
Min.15/32-inch plywood to mI
Base Sheet:
Elastobase (sanded top surface
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide si
Underlayment: Elastoflex G TU or Elastoflex S6
5.6.4.13 Maximum Design Pressure = -52.5 Dsf:
eet project requirements to satisfaction of Authority Having Jurisdiction.
pe II felt
ch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
ide laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
ering underlayment only) Polystick MTS PLUS, self -adhered
s, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
Deck: Min. 15/32-inch plywood to mE
Base Sheet: Elastobase (sanded top surface
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide si
Underlayment: Elastoflex G TU or Elastoflex S6
5.6.4.14 Maximum Design Pressure = -52.5 DO:
Deck:
Min. 15/32-inch plywood to me
Base Sheet:
Elastobase or Mule -Hide Nail B;
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide si
Base Ply:
(Optional) Polystick MTS PLUS,
Underlayment: Polystick TU P, Polystick TU Plu
Mule -Hide SA-APP Cap Sheet (F
5.6.4.15 Maximum Design
Pressure = -52.5 psf:
Deck:
Min. 15/32-inch plywood to me
Base Sheet:
Elastobase (sanded top surface
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide si
Underlayment: Elastoflex G TU or Elastoflex S6
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
FBC
et project requirements to satisfaction of Authority Having Jurisdiction.
for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap)
le laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
et project requirements to satisfaction of Authority Having Jurisdiction.
for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
(poly -film top surface)
laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
If -adhered
Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
, self -adhered.
project requirements to satisfaction of Authority Having Jurisdiction.
hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Evaluation Report P12060.02.09-R22
EVALUATION F1.5259-1126
USA, Inc. Revision 22: 03/13/2017
Page 8 of 14
C_)o
TRINITY I ERD
5.6.4.16 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torcli-applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.17 Maximum Design Pressure = -60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.18 Maximum Design Pressure = -67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
5.6.4.19 Maximum Design Pressure = -75 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners:
Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing:
10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
5.6.4.20 Maximum Design Pressure = -90 psf:
Deck:
Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment:
Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.21 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: CMG #12 Standard Roofgrip or CMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.22 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP orTrufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1122
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION, FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 9 of 14
5.6.4.23 Maximum Design Pressure = -90 psf:
Deck:
Min. 15/32-inch plywood to
Base Sheet:
Polyglass G2 Base or Polygla
Fasteners:
Dekfast #14 with Dekfast H(
OMG Flat Bottom Plates (.
Fasteners
Spacing:
9-inch o.c. at the 4-inch wid(
Underlayment: Elastoflex G TU or Elastofle
applied.
5.6.4.24 Maximum Design Pressure = -97.5 psf:
Deck:
Min. 19/32-inch plywood to
Base Sheet:
Elastobase or Mule -Hide Nail
Fasteners:
11 ga. x 1.25-inch x 3/8-inch
Spacing:
4-inch o.c. at the 4-inch wide
Base Ply:
(Optional) Polystick MTS PW
Underlayment: Polystick TU P, Polystick TU P
Mule -Hide SA-APP Cap Sheet
5.6.4.25 Maximum Design Pressure = -105 psf:
Deck:
Min. 15/32-inch plywood to r
Base Sheet:
Elastobase (sanded top surfai
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 2-inch wide
Underlayment: Elastoflex G TU or Elastoflex!
5.6.4.26 Maximum Design Pressure = -112.5 psf:
Deck:
Min. 19/32-inch plywood to r
Base Sheet:
Elastobase or Mule -Hide Nail
Fasteners:
11 ga. x 1.25-inch x 3/8-inch I
Spacing:
6-inch o.c. at the 4-inch wide
Primer:
PG100 or ASTM D41 primer a
Base Ply:
Polystick MTS PLUS, self-adhe
Underlayment: Polystick TU P, Polystick TU P
Mule -Hide SA-APP Cap Sheet
5.6.4.27 Maximum Design Pressure = -120 psf:
Deck: Min.15/32-inch plywood to r
Base Sheet: Elastobase (sanded top surfai
Fasteners: OMG #12 Standard Roofgrip
Plates
Spacing: 6-inch o.c. at the 4-inch wide
Underlayment: Elastoflex G TU or Elastoflex
5.6.4.28 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to r
Base Sheet: Elastobase (sanded top surfa(
Fasteners: Trufast #12 DP or Trufast #14
Spacing: 6-inch o.c. at the 4-inch wide
Underlayment: Elastoflex G TU or Elastoflex!
5.6.4.29 All other direct -deck, adhered Polyglas
Design Pressure of -45 psf.
V TRINITY I ERD
eet project requirements to satisfaction of Authority Having Jurisdiction.
APP Base (requires use of torch -applied underlayment)
plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
cuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
feet project requirements to satisfaction of Authority Having Jurisdiction.
Base (poly -film top surface)
lead diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
i, self -adhered
[us, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
(FR), self -adhered.
et project requirements to satisfaction of Authority Having Jurisdiction.
for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
le laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
get project requirements to satisfaction of Authority Having Jurisdiction.
ase (poly -film top surface)
gad diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
ide laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
all tin -caps
Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
. self -adhered.
et project requirements to satisfaction of Authority Having Jurisdiction.
for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
le laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
project requirements to satisfaction of Authority Having Jurisdiction.
D with Trufast 3" Metal Insulation Plates
de laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
G, applied in full mopping of hot asphalt.
underlayment systems beneath foam -on tile systems carry a Maximum
Exterior Research and Design, U.C. I Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 10 of 14
i
QO
TRINITY I ERA.
5.6.4.30 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 5.3, Note 1 of ASTM D1970-09, should be established as to slip resistance.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase, Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex G TU,
Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied.
6.3.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION. FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 11 of 14
TRINITY ERD
6.4 Polystick MTS, MTS PLUS, IR-Xe, TU P, +T+U Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR):
6.4.1 Shall be installed in compliance with tfie codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Note: Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM
D226 roofing felt in a dry condition, t Isted at standard laboratory conditions. Agreement between purchaser and
seller, as set forth in Section 5.3, Note 1 of ASTM D1970-09, should be established as to slip resistance.
6.4.2 Direct -to -Deck with Mechanically Faste ', ed Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using the above noted fasteners and splacing, in area marked "nail area, area para clavar" on the face of membrane.
The head lap membrane is to cover the area being back -nailed.
6.4.3
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the
the top sheet to the end of the glue
(the sheet will overlap the fabric).
All over -fabric and over -granule end-lar
Wet/Dry Cement or Polyglass PG500 M,
Polystick TU Plus, Dual Pro and Tile Pro
or exposed roof to wall details
Repair of Polystick membranes is to be a
Polyglass PG500 Modified Cement to
Polystick material of like kind, set and
installed in a water shedding manner.
All Polystick membranes shall be insta
minimum of 40-lb weighted -roller or, .or
for the field membrane. Hand rollers are
roof that are not accessible to a large rol
Reference is made to FRSA/TRI April 2C
above as a guideline.
For mechanically fastened the roofing c
Sheet fastening shall be not less than FI
For adhesive -set tile applications, refer
For nail -on tile systems over Polystick F
For nail -on tile systems over Polystick P
➢ Battens are required for loading/st
➢ Battens are required for loading/st
of
View of Ovelap Seam of Dual Pro and Tile Pro
shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
ified Cement applied in between the application of the.lap.
ay not be used in any exposed application such as crickets, exposed valleys,
:complished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
he area in need of repair, followed by a minimum 6 x 6 inch patch of the
hand rolled in place over the repair area. Patch laps, if needed, shall be
ed to ensure full contact with approved substrates. Polyglass requires a
steep slopes, use of a stiff broom with approximately 40-lbs of load applied
acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
�r or broom.
(04-12) Installation Manual and Table 1 herein, using the instructions noted
r 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
►/TRI April 2012 (04-12), Table 1.
Section 5.6.4 herein.
5, battens are required for loading / staging of the tile.
5 PLUS:
ng of lugged the regardless of slope.
ng of flat tile at slopes in excess of 5:12.
Exterior Research and Design, I.I.C. I Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVH2 EVALUATION FL5259-R26
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 12 of 14
TRINITY JEkD
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR:
6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D638O, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D638O, Class M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FIR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6 Polyflex G or Polyflex G FIR:
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in the applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FIR is for use as an alternate to the Heat Applied applied "Cap Sheet" in the "Two Ply System" from
FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.6.2 Polyflex G or Polyflex G FIR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R22
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 13 of 14
6_7
6.7.1
6.7.2
6.7.3
6.7.4
6.7.5
,I I RINITi I ERD
Tile Staging:
Tile shall be loaded and staged in a m?nner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for He staging.
Battens and/or Counter -battens, as.rZired by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. I Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or dlamage to the underlayment during the loading process.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
For nail -on tile systems over Polystick I( TS PLUS:
➢ Battens are required for loading/s�aging of lugged tile regardless of slope.
➢ Battens are required for loading/s aging of flat tile at slopes in excess of 5:12.
The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight
(48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority 1
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancelloi
Jurisdiction in order to properly evaluate the installation of this product.
uct locations covered for F.A.C. Rule 61G20-3 OA requirements.
Isom
OF EVALUATION REPORT -
Exterior Research and Design, U.C. IEvaluation Report P12060.02.09-R22
Certificate of Authorization #9503 Fi3 1,1014-HVH2 EVALUATION FL5259-1126
Polyglass USA, Inc. Revision 22: 03/13/2017
Page 14 of 14